Agilent n1912a инструкция на русском

  1. Manuals
  2. Brands
  3. Agilent Technologies Manuals
  4. Measuring Instruments
  5. N1912A

Manuals and User Guides for Agilent Technologies N1912A. We have 3 Agilent Technologies N1912A manuals available for free PDF download: Programming Manual, User Manual, Configuration Manual

Agilent Technologies N1912A Programming Manual

Agilent Technologies N1912A Programming Manual (803 pages)

P-Series Power Meters

Brand: Agilent Technologies
|
Category: Measuring Instruments
|
Size: 5.3 MB

Table of Contents
  • Table of Contents

    14

    • General Safety Considerations

      5

      • Table of Contents

        14

  • Table of Contents

    18

    • List of Figures

      23

  • List of Tables

    25

    • Power Meter Remote Operation

      29

    • Introduction

      33

    • Configuring the Remote Interface

      34

    • GPIB Address

      34

    • Interface Selection

      34

    • LAN Configuration

      35

    • USB Configuration

      36

    • Calibration

      37

    • Zeroing

      37

    • Zeroing and Calibrating the P-Series Power Sensor

      37

    • Making Measurement

      39

    • Table 1-1 Measure? and Configure Preset States

      39

    • Using Measure

      40

    • Table 1-2 Possibilities of the Defaulted Source List Parameter

      44

    • Using the Configure Command

      45

    • Using the Lower Level Commands

      54

    • Overview

      55

    • Using Frequency Dependent Offset Tables

      55

    • Editing Frequency Dependent Offset Tables

      57

    • Enabling a Frequency Dependent Offset Table

      60

    • Making the Measurement

      60

    • Selecting a Frequency Dependent Offset Table

      60

    • Averaging

      62

    • Resolution

      62

    • Setting the Range, Resolution and Averaging

      62

    • Auto Averaging Mode

      63

    • Filter Length

      64

    • Range

      65

    • Channel Offsets

      66

    • Display Offsets

      66

    • Setting Offsets

      66

    • Setting Limits

      68

    • Setting Measurement Limits

      68

    • Checking for Limit Failures

      70

    • Table 1-3 Range of Values for Window Limits

      70

    • Using Status

      71

    • Getting the Best Speed Performance

      72

    • Measurement Rate

      72

    • Sensor

      73

    • Table 1-4 Model of Sensor and Measurement Rates

      73

    • Trigger Mode

      73

    • Command Used

      75

    • Output Format

      75

    • Units

      75

    • Fast Mode

      76

    • How Measurements Are Calculated

      77

    • Status Reporting

      78

    • The General Status Register Model

      78

    • How to Use Register

      81

    • The Condition Polling Method

      81

    • The SRQ Method

      82

    • Table 1-5 Bit Definitions — Status Byte Register

      87

    • Table 1-6 Bit Definitions — Standard Event Register

      88

    • Table 1-7 Bit Definitions — Questionable Status Registers

      90

    • Table 1-8 Bit Change Conditions for Questionable Status Register

      90

    • Table 1-9 Bit Definitions — Operation Status

      91

    • Table 1-10 Bit Change Conditions for Operation Status

      92

    • Device Status Register

      93

    • Table 1-11 Bit Definitions — Device Status Register

      93

    • Table 1-12 Bit Change Conditions for Device Status Register

      94

    • Using the Operation Complete Commands

      95

    • How to Save and Recall a Configuration

      97

    • Saving and Recalling Power Meter Configurations

      97

    • Using Device Clear to Halt Measurements

      98

    • An Introduction to the SCPI Language

      99

    • Mnemonic Forms

      99

    • Using a Colon (:)

      99

    • Using «?» Commands

      100

    • Using a Comma (,)

      100

    • Using a Semicolon (;)

      100

    • Using Whitespace

      100

    • Syntax Conventions

      101

    • Syntax Diagram Conventions

      101

    • Using «*» Commands

      101

    • SCPI Data Types

      102

    • Input Message Terminators

      107

    • SCPI Compliance Information

      109

    • Summary of Commands

      111

    • Making Measurements on Wireless Communication Standards

      112

      • Starting a Preset Example

        113

  • 2 Measurement Commands

    115

    • Measurement Commands

      117

    • Configure[1] |2|3|4

      122

    • Configure [1] |2|3|4 Commands

      125

    • Configure[1]|2|3|4[:Scalar][:Power:ac] [<Expected_Value>[,<Resolution>[,<Source List>]]]

      126

    • Configure[1]|2|3|4[:Scalar][:Power:ac]:Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]

      128

    • Configure[1]|2|3|4[:Scalar][:Power:ac]:Difference [<Expected_Value>[,<Resolution>[,<Source List>]]]

      130

    • Configure[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]

      132

    • Configure[1]|2|3|4[:Scalar][:Power:ac]:Ratio [<Expected_Value>[,<Resolution>[,<Source List>]]]

      134

    • Configure[1]|2|3|4[:Scalar][:Power:ac]:Ratio: Relative[<Expected_Value>[,<Resolution>[,<Source List>]]]

      136

    • Fetch[1]|2|3|4 Queries

      138

    • Fetch[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      139

      • Error Messages

        140

    • Fetch[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      141

    • Fetch[1]|2|3|4[:Scalar][:Power:ac]:Difference? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      144

    • Fetch[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      147

    • Fetch[1]|2|3|4[:Scalar][:Power:ac]:Ratio? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      150

    • Fetch[1]|2|3|4[:Scalar][:Power:ac]:Ratio:relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      153

    • READ[1]|2|3|4 Commands

      156

    • Read[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      157

    • Read[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      160

    • Read[1]|2|3|4[:Scalar][:Power:ac]:Difference? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      163

    • Read[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      166

    • Read[1]|2|3|4[:Scalar][:Power:ac]:Ratio? [<Expected_Value>[,<Resolution>[,<Source List>]]]

      169

      • Read[1]|2|3|4[:Scalar][:Power:ac]:Ratio:relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

        172

      • Measure[1]|2|3|4 Commands

        175

        • Measure[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]

          176

        • Measure[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

          178

        • Measure[1]|2|3|4[:Scalar][:Power:ac]:Difference? [<Expected_Value>[,<Resolution>[,<Source List>]]]

          180

        • Measure[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative Expected_Value>[,<Resolution>[,<Source List>]]]

          182

        • Measure[1]|2|3|4[:Scalar][:Power:ac]:Ratio? [<Expected_Value>[,<Resolution>[,<Source List>]]]

          184

        • Measure[1]|2|3|4[:Scalar][:Power:ac]:Ratio:relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]

          186

  • 3 Calculate Subsystem

    189

    • Calculate Subsystem

      190

    • Calculate[1]|2|3|4:Feed[1]|2 <String

      193

    • Error Message

      195

    • Calculate[1]|2|3|4:Gain Commands

      196

    • Calculate[1]|2|3|4:Gain[:Magnitude] <Numeric_Value

      197

    • Calculate[1]|2|3|4:Gain:state <Boolean

      199

    • Calculate[1]|2|3|4:Limit Commands

      201

    • Calculate[1]|2|3|4:Limit:clear:auto <Boolean>|Once

      202

    • Calculate[1]|2|3|4:Limit:clear[:Immediate]

      204

    • Calculate[1]|2|3|4:Limit:fail

      205

    • Calculate[1]|2|3|4:Limit:fcount

      206

    • Calculate[1]|2|3|4:Limit:lower[:Data] <Numeric_Value

      208

    • Table 3-13 Measurement Units

      208

    • Calculate[1]|2|3|4:Limit:upper[:Data] <Numeric_Value

      211

    • Table 3-14 Measurement Units

      211

    • Calculate[1]|2|3|4:Limit:state <Boolean

      214

    • Calculate[1]|2|3|4:Math Commands

      216

    • Calculate[1]|2|3|4:Math[:Expression] <String

      217

    • Calculate[1]|2|3|4:Math[:Expression]:Catalog

      220

    • Calculate[1]|2|3|4:Phold:clear

      221

    • Calculate[1]|2|3|4:Relative Commands

      222

    • Calculate[1]|2|3|4:Relative[:Magnitude]:Auto <Boolean>|Once

      223

    • Calculate[1]|2|3|4:Relative:state <Boolean

      225

  • 4 Calibration Subsystem

    227

    • Calibration Subsystem

      228

    • Calibration[1]|2[:All]

      230

    • Calibration[1]|2[:All]

      232

    • Calibration[1]|2:Auto [ONCE|ON|OFF|0|1]

      234

    • Calibration[1]|2:Rcalibration <Boolean

      237

    • Calibration[1]|2:Rcfactor <Numeric_Value

      239

    • Calibration[1]|2:Zero:auto [ONCE|ON|OFF|0|1]

      241

    • Calibration[1]|2:Zero:normal:auto <Boolean

      243

  • 5 Display Subsystem

    245

    • Display Subsystem

      246

    • Display:enable <Boolean

      247

    • Display:screen:format <Character_Data

      249

    • Display[:Window[1]|2] Commands

      251

    • Display[:Window[1]|2]:Analog Commands

      252

    • Display[:Window[1]|2]:Analog:lower <Numeric_Value

      253

    • Table 5-15 Measurement Units

      253

    • Display[:Window[1]|2]:Analog:upper <Numeric_Value

      256

    • Table 5-16 Measurement Units

      256

    • Display[:Window[1]|2]:Format <Character_Data

      259

    • Display[:Window[1]|2]:Meter Commands

      262

    • Display[:Window[1]|2]:Meter:lower <Numeric_Value

      263

    • Table 5-17 Measurement Units

      263

    • Display[:Window[1]|2]:Meter:upper <Numeric_Value

      266

    • Table 5-18 Measurement Units

      266

    • Display[:Window[1]|2][:Numeric[1]|2]:Resolution <Numeric_Value

      269

    • Display[:Window[1]|2]:Select[1]|2

      271

    • Display[:Window[1]|2][:State] <Boolean

      273

    • Display[:Window[1]|2]:Trace:feed <Character_Data

      275

    • Format Subsystem

      277

    • Format Subsystem

      278

      • Format[:Readings]:Border <Character_Data

        279

      • Format[:Readings][:Data] <Character_Data

        281

  • 7 Memory Subsystem

    283

    • Memory Subsystem

      284

    • Memory:catalog Commands

      286

    • Memory:catalog[:All]

      287

    • Table 7-19 8480 Series Power Sensor Tables

      288

    • Memory:catalog:state

      289

    • Memory:catalog:table

      290

    • Table 7-20 8480 Series Power Sensor Tables

      291

    • Memory:clear Commands

      293

    • Memory:clear[:Name] <Character_Data

      294

    • Memory:clear:table

      296

    • Memory:free Commands

      297

    • Memory:free[:All]

      298

    • Memory:free:state

      299

    • Memory:free:table

      300

    • Memory:nstates

      301

    • Memory:state Commands

      302

    • Memory:state:catalog

      303

    • Memory:state:define <Character_Data>,<Numeric_Value

      304

    • Memory:table Commands

      306

    • Memory:table:frequency <Numeric_Value>{,<Numeric_Value

      307

    • Table 7-21 Frequency and Calibration/Offset Factor List

      308

    • Memory:table:frequency:points

      311

    • Memory:table:gain[:Magnitude] <Numeric_Value>{,<Numeric_Value

      312

    • Table 7-22 Frequency and Calibration/Offset Factor List

      312

    • Memory:table:gain[:Magnitude]:Points

      315

    • Memory:table:move <Character_Data>,<Character_Data

      316

    • Memory:table:select <Character_Data

      318

  • 8 Output Subsystem

    319

    • Output Subsystem

      320

    • Output:recorder[1]|2:Feed <Data_Handle

      321

    • Output:recorder[1]|2:Limit:lower <Numeric_Value

      323

    • Output:recorder[1]|2:Limit:upper <Numeric_Value

      325

    • Output:recorder[1]|2:State <Boolean

      327

    • Output:roscillator[:State] <Boolean

      329

    • Output:trigger[:State] <Boolean

      331

  • 9 Pstatistic Subsystem

    333

    • Pstatistic Subsystem

      335

    • Pstatistic:ccdf:gaussian[:State] <Boolean

      337

    • Pstatistic:ccdf:gaussian:marker[1]|2[:Set]

      339

    • Pstatistic:ccdf:marker:delta

      341

    • Pstatistic:ccdf:marker[1]|2:Data

      343

    • Pstatistic:ccdf:marker[1]|2:X <Numeric_Value

      345

    • Pstatistic:ccdf:marker[1]|2:Y <Numeric_Value

      347

    • Pstatistic:ccdf:reference:data

      349

    • Pstatistic:ccdf:reference[:State] <Boolean

      351

    • Pstatistic:ccdf:reference:marker[1]|2[:Set]

      353

    • Pstatistic:ccdf:reference:power:average

      355

    • Pstatistic:ccdf:reference:power:peak

      356

    • Pstatistic:ccdf:reference:power:ptaverage

      357

    • Pstatistic[1]|2:Ccdf:continuous <Boolean

      358

    • Pstatistic[1]|2:Ccdf:count <Numeric_Value

      360

    • Pstatistic[1]|2:Ccdf:data

      362

    • Pstatistic[1]|2:Ccdf:data:max <Numeric_Value

      364

    • Pstatistic[1]|2:Ccdf:power? <Numeric_Value

      366

    • Pstatistic[1]|2:Ccdf:probability? <Numeric_Value

      368

    • Pstatistic[1]|2:Ccdf:store:reference

      370

    • Pstatistic[1]|2:Ccdf:table

      372

    • Pstatistic[1]|2:Ccdf:trace[:State] <Boolean

      375

    • Pstatistic[1]|2:Ccdf:trace:marker[1]|2[:Set]

      377

    • Pstatistic[1]|2:Ccdf:trace:power:average

      379

    • Pstatistic[1]|2:Ccdf:trace:power:peak

      381

    • Pstatistic[1]|2:Ccdf:trace:power:ptaverage

      383

  • 10 Sense Subsystem

    385

    • [Sense] Subsystem

      387

    • [Sense[1]]|Sense2:Average Commands

      390

    • [Sense[1]]|Sense2:Average:count <Numeric_Value

      391

    • [Sense[1]]|Sense2:Average:count:auto <Boolean

      394

    • [Sense[1]]|Sense2:Average:sdetect <Boolean

      397

    • [Sense[1]]|Sense2:Average[:State] <Boolean

      399

    • [Sense[1]]|Sense2:Average2 Commands

      401

    • [Sense[1]]|Sense2:Average2:Count <Numeric_Value

      402

    • [Sense[1]]|Sense2:Average2[:State] <Boolean

      404

    • [Sense[1]]|Sense2:Bandwidth|Bwidth:video <Character_Data

      406

    • [Sense[1]]|Sense2:Buffer:count <Numeric_Value

      409

    • [Sense[1]]|Sense2:Buffer:mtype <String

      412

    • [Sense[1]]|Sense2:Correction Commands

      415

    • [Sense[1]]|Sense2:Correction:cfactor|Gain[1][:Input][:Magnitude] <Numeric_Value

      416

    • [Sense[1]]|Sense2:Correction:cset[1]|Cset2 Commands

      419

    • [Sense[1]]|Sense2:Correction:cset[1]|Cset2[:Select] <String

      420

    • [Sense[1]]|Sense2:Correction:cset[1]|Cset2:State <Boolean

      423

    • [Sense[1]]|Sense2:Correction:dcycle|Gain3 Commands

      425

    • [Sense[1]]|Sense2:Correction:dcycle|Gain3[:Input] [:Magnitude] <Numeric_Value

      426

    • [Sense[1]]|Sense2:Correction:dcycle|Gain3:State <Boolean

      429

    • [Sense[1]]|Sense2:Correction:fdoffset|Gain4[:Input][:Magnitude]

      431

    • [Sense[1]]|Sense2:Correction:gain2 Commands

      432

    • [Sense[1]]|Sense2:Correction:gain2:State <Boolean

      433

    • [Sense[1]]|Sense2:Correction:gain2[:Input] [:Magnitude] <Numeric_Value

      435

    • [Sense[1]]|Sense2:Detector:function <Character_Data

      438

    • [Sense[1]]|Sense2:Frequency[:Cw|:Fixed] <Numeric_Value

      440

    • [Sense[1]]|Sense2:Frequency[:Cw|:Fixed]:Start <Numeric_Value

      443

    • [Sense[1]]|Sense2:Frequency[:Cw|:Fixed]:Step <Numeric_Value

      446

    • [Sense[1]]|Sense2:Frequency[:Cw|:Fixed]:Stop <Numeric_Value

      450

    • [Sense[1]]|Sense2:Mrate <Character_Data

      453

    • [Sense[1]]|Sense2:Power:ac:range <Numeric_Value

      456

    • [Sense[1]]|Sense2:Power:ac:range:auto <Boolean

      458

    • [Sense[1]]|Sense2:Sweep[1]|2|3|4 Commands

      460

    • [Sense[1]]|Sense2:Sweep[1]|2|3|4:Auto <Character_Data

      461

    • Numeric_Value

      464

    • [Sense[1]]|Sense2:Sweep[1]|2|3|4:Auto:ref1|Ref2

      464

    • [Sense[1]]|Sense2:Sweep[1]|2|3|4:Offset:time <Numeric_Value

      466

    • [Sense[1]]|Sense2:Sweep[1]|2|3|4:Time <Numeric_Value

      468

    • [Sense[1]]|Sense2:Temperature

      470

    • [Sense[1]]|Sense2:Trace Commands

      472

    • [Sense[1]]|Sense2:Trace:offset:time <Numeric_Value

      473

    • [Sense[1]]|Sense2:Trace:time <Numeric_Value

      475

    • [Sense[1]]|Sense2:Trace:unit <Character_Data

      477

    • [Sense[1]]|Sense2:V2P Atype|Dtype

      479

    • Sense[1]|2:Trace:autoscale

      481

    • Sense[1]|2:Trace:limit:lower <Numeric_Value

      483

    • Table 10-23Measurement Units

      483

    • Sense[1]|2:Trace:limit:upper <Numeric_Value

      486

    • Table 10-24Measurement Units

      486

    • Sense[1]|2:Trace:X:scale:pdiv <Numeric_Value

      489

    • Sense[1]|2:Trace:y:scale:pdiv <Numeric_Value

      491

  • 11 Status Subsystem

    493

    • Status Subsystem

      494

    • Table 11-25Commands and Events Affecting Status Register

      494

    • Status Register Set Commands

      496

    • Device Status Register Sets

      501

    • Operation Register Sets

      503

    • Status:operation

      504

    • Status:operation:calibrating[:Summary]

      505

    • Status:operation:llfail[:Summary]

      506

    • Status:operation:measuring[:Summary]

      507

    • Status:operation:sense[:Summary]

      508

    • Status:operation:trigger[:Summary]

      509

    • Status:operation:ulfail[:Summary]

      510

    • Status:preset

      511

    • Questionable Register Sets

      512

    • Status:questionable

      513

    • Status:questionable:calibration[:Summary]

      514

    • Status:questionable:power[:Summary]

      515

  • 12 System Subsystem

    519

    • System Subsystem

      520

    • System:communicate:gpib[:Self]:Address <Numeric_Value

      522

    • System:communicate:lan:aip[:State] <Boolean

      524

    • System:communicate:lan:current:address

      525

    • System:communicate:lan:current:dgateway

      526

    • System:communicate:lan:current:dname

      527

    • System:communicate:lan:current:smask

      528

    • System:communicate:lan:address <Character_Data

      529

    • System:communicate:lan:dgateway <Character_Data

      531

    • System:communicate:lan:dhcp[:State] <Boolean

      533

    • System:communicate:lan:dname <Character_Data

      534

    • System:communicate:lan:hname <Character_Data

      536

    • System:communicate:lan:mac

      538

    • System:communicate:lan:restart

      539

    • System:communicate:lan:smask <Character_Data

      540

    • System:display:bmp

      542

    • System:error

      543

    • System:help:headers

      551

    • System:local

      553

    • System:preset <Character_Data

      554

    • Table 12-26Default: Power Meter Presets

      557

    • Table 12-27GSM900: Power Meter Presets

      561

    • Table 12-28GSM900: Power Meter Presets: Window/Measurement Settings

      562

    • Table 12-29GSM900: Power Meter Presets for Secondary Channel Sensors

      563

    • Table 12-30EDGE: Power Meter Presets

      564

    • Table 12-31EDGE: Power Meter Presets: Window/Measurement Settings

      566

    • Table 12-32EDGE: Power Meter Presets for Secondary Channel Sensors

      566

    • Table 12-33Cdmaone: Power Meter Presets

      568

    • Table 12-34Cdmaone: Power Meter Presets: Window/Measurement Settings

      569

    • Table 12-35 Cdmaone: Power Meter Presets for Secondary Channel Sensors

      570

    • Table 12-36 Cdma2000: Power Meter Presets

      572

    • Table 12-37 Cdma2000: Power Meter Presets: Window/Measurement Settings

      573

    • Table 12-38 Cdma2000: Power Meter Presets for Secondary Channel Sensors

      574

    • Table 12-39 W-CDMA: Power Meter Presets

      576

    • Table 12-40 W-CDMA: Power Meter Presets: Window/Measurement Settings

      577

    • Table 12-41 W-CDMA: Power Meter Presets for Secondary Channel Sensors

      578

    • Table 12-42 Bluetooth: Power Meter Presets

      580

    • Table 12-43 Bluetooth: Power Meter Presets: Window/Measurement Settings

      581

    • Table 12-44 Bluetooth: Power Meter Presets for Secondary Channel Sensors

      582

    • Table 12-45 MPCA: Power Meter Presets

      583

    • Table 12-46 MPCA: Power Meter Presets: Window/Measurement Settings

      584

    • Table 12-47 MCPA: Power Meter Presets for Secondary Channel Sensors

      585

    • Table 12-48 RADAR: Power Meter Presets

      586

    • Table 12-49 RADAR: Power Meter Presets: Window/Measurement Settings

      587

    • Table 12-50 RADAR: Power Meter Presets for Secondary Channel Sensors

      588

    • Table 12-51 802.11A and Hiperlan2: Power Meter Presets

      590

    • Table 12-52 802.11A and Hiperlan2: Power Meter Presets: Window/Measurement Settings

      591

    • Table 12-53 802.11A and Hiperlan2: Power Meter Presets for Secondary Channel Sensors

      592

    • Table 12-54 802.11B/G: Power Meter Presets

      593

    • Table 12-55 802.11B/G: Power Meter Presets: Window/Measurement Settings

      594

    • Table 12-56 802.11B/G: Power Meter Presets for Secondary Channel Sensors

      595

    • Table 12-57 1Xev-DO: Power Meter Presets

      596

    • Table 12-58 1Exv-DO: Power Meter Presets: Window/Measurement Settings

      597

    • Table 12-59 1Exv-DO: Power Meter Presets for Secondary Channel Sensors

      598

    • Table 12-60 1Exv-DV: Power Meter Presets

      599

    • Table 12-61 1Xev-DV: Power Meter Presets: Window/Measurement Settings

      600

    • Table 12-62 1Xev-DV: Power Meter Presets for Secondary Channel Sensors

      601

    • Table 12-63 TD-SCDMA: Power Meter Presets

      602

    • Table 12-64 TD-SCDMA: Power Meter Presets: Window/Measurement Settings

      603

    • Table 12-65 TD-SCDMA: Power Meter Presets: Window/Measurement Settings

      604

    • Table 12-66 NADC: Power Meter Presets

      605

    • Table 12-67 NADC: Power Meter Presets: Window/Measurement Settings

      607

    • Table 12-68 NADC: Power Meter Presets for Secondary Channel Sensors

      607

    • Table 12-69 Iden: Power Meter Presets

      609

    • Table 12-70 Iden: Power Meter Presets: Window/Measurement Settings

      611

    • Table 12-71 Iden: Power Meter Presets for Secondary Channel Sensors

      611

    • Table 12-72 DVB: Power Meter Presets

      613

    • Table 12-73 DVB: Power Meter Presets: Window/Measurement Settings

      614

    • Table 12-74 DVB: Power Meter Presets for Secondary Channel Sensors

      615

    • Table 12-75 Wimax: Power Meter Presets

      616

    • Table 12-76 Wimax: Power Meter Presets: Window/Measurement Settings

      617

    • Table 12-77 Wimax: Power Meter Presets for Secondary Channel Sensors

      618

    • Table 12-78 DME: Power Meter Presets

      619

    • Table 12-79 DME: Power Meter Presets: Window/Measurement Settings

      620

    • Table 12-80 DME: Power Meter Presets for Secondary Channel Sensors

      621

    • Table 12-81 DME-PRT: Power Meter Presets

      623

    • Table 12-82 DME-PRT: Power Meter Presets: Window/Measurement Settings

      624

    • Table 12-83 DME-PRT: Power Meter Presets for Secondary Channel Sensors

      625

    • Table 12-84 HSPDA: Power Meter Presets

      627

    • Table 12-85 HSPDA: Power Meter Presets: Window/Measurement Settings

      628

    • Table 12-86 HSDPA: Power Meter Presets for Secondary Channel Sensors

      629

    • Table 12-87LTE: Power Meter Presets

      630

    • Table 12-88 LTE: Power Meter Presets: Window/Measurement Settings

      631

    • Table 12-89 LTE: Power Meter Presets for Secondary Channel Sensors

      632

    • System:remote

      633

    • System:rwlock

      634

    • System:version

      635

    • Trace Subsystem

      638

      • Trace[1]|2[:Data]? <Character_Data

        640

      • Trace[1]|2:Define:duration:reference<Numeric_Value

        642

      • Trace[1]|2:Define:transition:reference <Numeric_Value>, <Numeric_Value

        644

      • Trace[1]|2:Measurement:instant:reference? <Numeric_Value

        646

      • Trace[1]|2:Measurement:pulse[1]|…|10:Dcycle

        648

      • Trace[1]|2:Measurement:pulse[1]|…|10:Duration

        650

      • Trace[1]|2:Measurement:pulse[1]|…|10:Period

        652

      • Trace[1]|2:Measurement:pulse[1]|…|10:Separation

        654

      • Trace[1]|2:Measurement:transition[1]|…|10:Negative:duration

        656

      • Trace[1]|2:Measurement:transition[1]|…|10:Negative:occurrence

        658

      • Trace[1]|2:Measurement:transition[1]|…|10:Positive:duration

        660

      • Trace[1]|2:Measurement:transition[1]|…|10:Positive:occurrence

        662

      • Trace[1]|2:Measurement:reference? <Numeric_Value

        664

      • Trace[1]|2:State <Boolean

        666

      • Trace[1]|2:Unit <Character_Data

        668

    • Trigger Subsystem

      672

      • Abort[1]|2]

        674

      • Initiate Commands

        675

      • Initiate[1]|2:Continuous <Boolean

        676

      • Initiate[1]|2[:Immediate]

        679

      • Initiate:continuous:all <Boolean

        680

      • Initiate:continuous:sequence[1]|2 <Boolean

        682

      • Initiate[:Immediate]:All

        684

      • Initiate[:Immediate]:Sequence[1]|2

        685

      • Trigger Commands

        686

      • Trigger[1]|2:Delay:auto <Boolean

        687

      • Trigger[1]|2[:Immediate]

        689

      • Trigger[1]|2:Source Bus|External|Hold|Immediate|Internal[[1]|2]

        690

      • Trigger[:Sequence]:Delay <Numeric_Value

        693

      • Trigger[:Sequence]:Holdoff <Numeric_Value

        695

      • Trigger[:Sequence]:Hysteresis <Numeric_Value

        697

      • Trigger[:Sequence]:Level <Numeric_Value

        699

      • Trigger[:Sequence]:Level:auto <Boolean

        701

      • Trigger[:Sequence]:Slope <Character_Data

        703

      • Trigger[:Sequence[1]|2]:Count <Numeric_Value

        705

      • Trigger[:Sequence[1]|2]:Delay:auto <Boolean

        708

      • Trigger[:Sequence[1]|2]:Immediate

        710

      • Trigger[:Sequence[1]|2]:Source Bus|External|Hold|Immediate|Internal[[1]|2]

        711

    • Service Subsystem

      717

      • Service:bist:calibrator <Boolean

        719

      • Service:bist:cw[1]|2:Linearity

        721

      • Service:bist:cw[1]|2:Linearity:perror

        722

      • Service:bist:cw[1]|2:Zset:number

        723

      • Service:bist:peak[1]|2:Linearity <Numeric_Value

        724

      • Service:bist:peak[1]|2:Linearity:perror

        725

      • Service:bist:peak[1]|2:Zset

        726

      • Service:bist:peak[1]|2:Zset:number

        727

      • Service:bist:tbase:state

        728

      • Service:bist:tbase:state <Boolean

        729

      • Service:bist:trigger:test

        731

      • Service:calibrator:adj:cour <Numeric_Value

        732

      • Service:calibrator:adj:fine <Numeric_Value

        733

      • Service:lan:phostname

        734

      • Service:option <Character_Data

        735

      • Service:secure:erase

        737

      • Service:sensor[1]|2:Calfactor <Cal_Factor_Data

        738

      • Service:sensor[1]|2:Cdate

        740

      • Service:sensor[1]|2:Corrections:state <Boolean

        741

      • Service:sensor[1]|2:Cplace

        743

      • Service:sensor[1]|2:Frequency:maximum

        744

      • Service:sensor[1]|2:Frequency:minimum

        745

      • Service:sensor[1]|2:Pcalfactor <Cal_Factor_Data

        746

      • Service:sensor[1]|2:Power:average:maximum

        748

      • Service:sensor[1]|2:Power:peak:maximum

        749

      • Service:sensor[1]|2:Power:usable:maximum

        750

      • Service:sensor[1]|2:Power:usable:minimum

        751

      • Service:sensor[1]|2:Radc

        752

      • Service:sensor[1]|2:Snumber

        753

      • Service:sensor[1]|2:Tnumber

        754

      • Service:sensor[1]|2:Type

        755

      • Service:snumber <Character_Data

        756

      • Service:version:processor <Character_Data

        757

      • Service:version:system <Character_Data

        758

      • Unit Subsystem

        759

    • UNIT Subsystem

      760

      • Unit[1]|2|3|4:Power <Amplitude_Unit

        761

      • Unit[1]|2|3|4:Power:ratio <Ratio_Unit

        763

      • SCPI Compliance Information

        766

      • DDT <Arbitrary Block Program Data>|<String Program Data

        768

      • Table 17-90*ESE Mapping

        770

        • ESE <Nrf

          770

        • Table 17-91*ESR? Mapping

          772

      • RCL <Nrf

        776

      • SAV <Nrf

        778

      • Table 17-92*SRE Mapping

        779

        • SRE <Nrf

          779

        • Table 17-93 *STB? Mapping

          781

      • GPIB Universal Commands

        786

      • Table 17-94PPD Mapping

        787

      • Table 17-95PPE Mapping

        788

      • Table A-96 Calibration Factor Block Layout: E4410 Series Sensors

        792

      • Table A-97 Calibration Factor Block Layout: E9300 Series Sensors

        793

      • Table A-98 Calibration Factor Block Layout: E9320 Series Sensors

        794

Advertisement

Agilent Technologies N1912A User Manual

Agilent Technologies N1912A User Manual (297 pages)

P-Series Power Meters

Brand: Agilent Technologies
|
Category: Measuring Instruments
|
Size: 4.12 MB

Table of Contents
  • Certification

    3

  • General Warranty

    3

  • Warranty Service

    3

  • Limitation of Warranty

    4

  • Exclusive Remedies

    4

  • Restricted Rights Legend

    5

  • Technology Licenses

    5

  • Safety Summary

    6

  • Recommended Calibration Interval

    6

  • Safety Symbols

    7

  • General Safety Information

    10

  • Environmental Conditions

    11

  • Regulatory Information

    11

  • Regulatory Markings

    12

  • Declaration of Conformity (Doc)

    13

  • In this Guide

    14

  • Table of Contents

    15

  • 1 Introduction

    28

    • LXI Class-C Compliant Power Meter

      28

    • Rack Mounting

      28

    • Power Meter and Sensor Capability

      29

    • Conventions Used in this Guide

      30

    • Front Panel Keys and Connections

      31

    • The Display Layout

      36

    • Figure 1-1 Dual Numeric Display

      36

    • Figure 1-2 Single Numeric and Analog Display

      38

    • Figure 1-3 Full Screen Numeric Display

      39

    • Figure 1-4 Trace Display in both Windows

      40

    • Figure 1-5 Trace Display in Single Enlarged Window in Markers Mode

      41

    • Figure 1-6 Trace Display in Single Enlarged Window in Trigger Delay Mode

      42

    • Figure 1-7 Trace Display in Single Enlarged Window in Trace Control Mode

      43

    • Window Symbols and Pop-Ups

      44

    • Using the Instrument Web Browser

      48

    • Figure 1-8 Opening the Instrument Web Interface

      48

    • Figure 1-9 N1912A P-Series Power Meter Web Browser (Welcome Page)

      49

    • Figure 1-10 Status Message before Toggle ID Is Selected

      50

    • Figure 1-11 Status Message When Toggle ID Is Selected

      50

    • Figure 1-12 Example of Lan Status Message

      51

    • Table 1-1 Type of Lan Status Message

      51

    • Figure 1-13 Viewing LAN Configuration Settings from the Web Interface

      52

    • Figure 1-14 Password Security Dialog Box

      53

    • Figure 1-15 Changing the Instrument LAN Interface Configuration

      54

  • 2 General Power Meter Functions

    56

    • Setting the Units of Measurement

      56

    • Table 2-2 Measurement Units — Single Channel Meters

      56

    • Table 2-3 Measurement Units — Dual Channel Meters

      56

    • Setting the Measurement Frequency

      58

    • Figure 2-16 Frequency Pop-Up

      58

    • Setting the Resolution

      59

    • Making Relative Measurements

      60

    • Figure 2-17 Typical Relative Measurement Display

      60

    • Figure 2-18 Numeric Display

      61

    • Setting the Pulse Reference Levels

      62

    • Figure 2-19 Measurement Configuration Screen

      62

    • Figure 2-20 Pulse Duration Measurement between Two Reference Levels

      63

    • Figure 2-21 Trace Ref Lvl 1 Pop-Up

      63

    • Figure 2-22 Trace Ref Lvl 2 Pop-Up

      64

    • Figure 2-23 Pulse Duration Ref Lvl Pop-Up

      64

    • Setting Offsets

      65

    • Figure 2-24 Simplified Measurement Path

      65

    • Figure 2-25 Typical Channel Offset Display

      66

    • Figure 2-26 Channel Offset Indicator

      67

    • Figure 2-27 Typical Display Offset Display

      68

    • Figure 2-28 Frequency Dependent Offset Tables Display

      70

    • Figure 2-29 Frequency Dependent Offset Indicator

      71

    • Figure 2-30 «Edit Offset» Display with Data Added

      72

    • Figure 2-31 Edit Table Title Pop-Up

      73

    • Setting Measurement Averaging

      75

    • Figure 2-32 Typical Averaged Readings

      75

    • Figure 2-33 Meas Avg Count Pop-Up

      76

    • Step Detection

      77

    • Setting the Video Averaging

      78

    • Figure 2-34 Video Avg Count Pop-Up

      79

    • Setting the Video Bandwidth

      80

    • Table 2-4 P-Series Sensor Video Bandwidth Setting

      80

    • Figure 2-35 Bandwidth Filter Shapes

      81

    • Figure 2-36 Video Bandwidth Pop-Up

      82

    • Setting Measurement Channel Gates

      83

    • Figure 2-37 Example of Measurement Gates

      83

    • Figure 2-38 Gate Setup Screen

      84

    • Figure 2-39 Time Gating Start Pop-Up

      85

    • Figure 2-40 Time Gating Length Pop-Up

      85

    • Figure 2-41 Auto Gate Settings Display

      86

    • Figure 2-42 Marker 1 Ref Percentage Pop-Up

      86

    • Figure 2-43 Marker 2 Ref Percentage Pop-Up

      87

    • Figure 2-44 the Placement of Gates (Markers) in Auto Gating Mode

      87

    • Setting up the Channel Trace

      88

    • Figure 2-45 Trace Setup Display

      88

    • Figure 2-46 Trace Start Time Pop-Up

      89

    • Figure 2-47 X Scale/Division Pop-Up

      89

    • Figure 2-48 Trace Units Pop-Up

      90

    • Figure 2-49 y Scale Maximum Value Pop-Up

      90

    • Figure 2-50 y Scale/Division Pop-Up

      91

    • Setting the Trigger

      92

    • Figure 2-51 Trigger Menu — Free Run Mode

      92

    • Figure 2-52 Trigger Setting Menu 1

      93

    • Figure 2-53 Trigger Level Pop-Up

      94

    • Figure 2-54 Trigger Delay Pop-Up

      95

    • Figure 2-55 Trigger Setting Menu 2

      95

    • Figure 2-56 Trigger Holdoff Pop-Up

      96

    • Figure 2-57 Trigger Hysteresis Pop-Up

      97

    • Setting External Trigger for Normal and Average Power Measurement

      98

    • Table 2-5 Power and Frequency Sweep Mode Compatibility Table

      98

    • Table 2-6 Power and Frequency Sweep Measurement Functions Table

      99

    • Figure 2-58 TRIG in and TRIG out Connection Diagram between Power Meter and

      100

    • Power Source

      100

      • Figure 2-59 Channel Setup Display

        100

      • Figure 2-60 Sensor Mode Pop-Up

        101

      • Figure 2-61 Trigger Setting Menu 1

        102

      • Figure 2-62 Trigger Setting Menu 2

        102

      • Figure 2-63 Limits Checking Applications

        112

      • Figure 2-64 Limits Checking Results

        112

      • Setting Measurement Limits

        112

      • Table 2-7 Range of Values for Window Limits

        113

      • Figure 2-65 Minimum Limit Pop-Up

        114

      • Figure 2-66 Limit Failures

        115

      • Figure 2-67 Sixteen Measurements Per Channel

        116

      • Setting the Measurement Display

        116

      • Figure 2-68 Measurement Feed Example

        117

      • Figure 2-69 Measurement Setup Showing Single Configuration

        118

      • Figure 2-70 Function Pop-Up

        119

      • Figure 2-71 Measurement Type Pop-Up

        119

      • Figure 2-72 Gating Number Pop-Up

        120

      • Figure 2-73 Measurement Setup Showing Combined Configuration

        121

      • Figure 2-74 Measurement Example Display

        122

      • Figure 2-75 Maximum Limit Pop-Up

        123

      • Figure 2-76 Minimum Limit Pop-Up

        123

      • Scaling the Analog Display

        123

      • Figure 2-77 Increment and Decrement Multiplier

        124

      • Recorder Output

        125

      • Figure 2-78 Recorder Minimum Pop-Up

        126

      • Figure 2-79 Recorder Maximum Pop-Up

        126

      • Table 2-8 Ranges of Recorder Output Setting

        127

      • Figure 2-80 Increment and Decrement Multiplier

        128

      • Figure 2-83 Save/Recall Screen

        130

      • Saving and Recalling Power Meter States

        130

      • Figure 2-84 Save Confirm Pop-Up

        131

      • Figure 2-85 File Name Pop-Up

        131

      • Figure 2-86 Recall Pop-Up

        132

      • Figure 2-87 Zeroing Pop-Up

        133

      • Zeroing and Calibrating the P-Series Sensor

        133

      • Figure 2-88 Calibration Wait Pop-Up

        134

      • Figure 2-89 Please Zero and Calibrate Window

        136

      • Figure 2-90 Preset Display Options

        137

      • Presetting the Power Meter

        137

      • Table 2-9 Preset Compatibility Matrix for E-Series E9320 Power Sensor

        138

      • Setting the Cable Short/Long

        139

  • 3 Using P-Series Power Sensor

    141

    • Introduction

      142

    • Configuring a Power Measurement

      143

    • Setting the Trace Display

      144

    • Figure 3-92 P-Series Sensor Default Channel Setup

      145

    • Figure 3-93 Trace Display in Dual Channel Power Meter

      146

    • Figure 3-94 Trace Display in Single Enlarged Window

      147

    • Figure 3-95 Trace Display with Gate Control Menu

      148

    • Figure 3-96 Trace Display with Trigger Delay Menu

      149

    • Figure 3-97 Trace Display with Trace Control Menu

      151

    • Figure 3-98 Trace Display in Full Screen

      152

    • Figure 3-99 P-Series Power Sensor Default Channel Setup

      153

    • Figure 3-100Channel Offset Display

      154

  • 4 Using E9320 E-Series Power Sensors

    158

    • Introduction

      158

    • Table 4-10 Sensor Bandwidth

      158

    • Figure 4-101 Bandwidth Filter Shapes

      159

    • Power Meter Configuration

      160

    • Figure 4-102 E-Series E9320 Power Sensor Default Channel Setup

      160

    • Configuring a Peak Power Measurement

      161

    • Measurement Accuracy

      162

    • Setting the Trace Display

      164

    • Figure 4-104 E-Series E9320 Power Sensor Channel Setup When Trigger Is Selected

      166

    • Figure 4-105Trace Display in Dual Channel Power Meter

      166

    • Figure 4-106Trace Display in Single Enlarged Window

      167

    • Figure 4-107Trace Display with Gate Control Menu

      168

    • Figure 4-108Trace Display with Trigger Delay Menu

      169

    • Figure 4-109Trace Display with Trace Control Menu

      171

    • Figure 4-110Trace Display in Full Screen

      172

    • Figure 4-111E-Series E9320 Power Sensor Dafault Channel Setup

      173

    • Figure 4-112Channel Offset Display

      174

    • Introduction

      178

  • 5 Using E9300 E-Series Power Sensors

    179

    • Power Meter Configuration

      179

    • Figure 5-113E9300 E-Series Auto-Averaging Settings

      179

    • Figure 5-114 E9300 E-Series Sensor Default Channel Setup

      180

    • Measurement Accuracy

      181

    • Table 5-11 Power Sensor Connection Requirements

      181

    • Figure 5-115Frequency Pop-Up

      182

    • Measuring Spread Spectrum and Multitone Signals

      183

    • Figure 5-116Spread Spectrum Signal

      183

    • Figure 5-117 Wideband CDMA Error of E-Series E9300 Power Sensor Versus Corrected

      184

    • Figure 5-118CDMA (IS-95A): 9Ch Fwd

      184

    • Figure 5-119Calibration Factors Versus Frequency

      185

    • Measuring TDMA Signals

      186

    • Electromagnetic Compatibility (EMC) Measurements

      188

    • Measurement Accuracy and Speed

      189

  • 6 Using E4410 E-Series Power Sensors

    194

    • Introduction

      194

    • Power Meter Configuration

      195

    • Figure 6-120E-Series CW Sensor Auto-Averaging Settings

      195

    • Figure 6-121E-Series E4410 Sensor Default Channel Setup

      196

    • Measurement Accuracy

      197

    • Figure 6-122Frequency Pop-Up

      198

  • 7 Using 8480 Series Power Sensors

    200

    • Introduction

      200

    • Power Meter Configuration

      201

    • Figure 7-1238480 Series Auto-Averaging Settings

      201

    • Figure 7-1248480 Series Sensor Default Channel Setup

      202

    • Table 7-12 8480 Series Connection Requirements

      203

    • Measurement Accuracy

      205

    • Frequency Specific Calibration Factors

      206

    • Figure 7-125Reference Calibration Factor Pop-Up Window

      207

    • Figure 7-126Calibration Factor Pop-Up Window

      208

    • Figure 7-127Calibration Factor Display

      208

    • Sensor Calibration Tables

      210

    • Figure 7-128Sensor Table Selected

      211

    • Figure 7-129Frequency Dependent Offset Indicator

      211

    • Figure 7-130Frequency/Calibration Table Display

      212

    • Table 7-13 Installed Power Sensor Models

      213

    • Figure 7-131″Sensor Tbls» Screen

      214

    • Figure 7-132″Edit Cal» Display

      215

    • Figure 7-133Edit Table Title Pop-Up

      215

  • 8 Using N8480 Series Power Sensors

    222

    • Introduction

      222

    • Table 8-14 Power Range in the Range Setting

      222

    • Power Meter Configuration Changes

      224

    • Figure 8-134Auto-Averaging Settings

      224

    • Default Channel Setup

      225

    • Figure 8-135N8480 Series Sensor (Excluding Option CFT) Default Channel Setup

      225

    • N8480 Series Sensors Connection Requirements

      226

    • Table 8-15 N8480 Series Connection Requirements

      226

    • N8480 Series Power Sensors (Excluding Option CFT)

      227

    • Figure 8-137Frequency Pop-Up

      228

    • N8480 Series Power Sensors with Option CFT

      229

    • Figure 8-138Reference Calibration Factor Pop-Up Window

      230

    • Figure 8-139Calibration Factor Pop-Up Window

      231

    • Figure 8-140Calibration Factor Displayed

      232

    • Figure 8-141Sensor Table Selected

      235

    • Figure 8-142Frequency Dependent Offset Indicator

      236

    • Figure 8-143Frequency/Calibration Table Display

      237

    • Table 8-16 Installed Power Sensor Models

      238

    • Figure 8-144″Sensor Tbls» Screen

      239

    • Figure 8-145″Edit Cal» Display

      240

    • Figure 8-146Edit Table Title Pop-Up

      240

  • 9 Complementary Cumulative Distribution Function (CCDF)

    243

    • Introduction

      244

    • Setting the CCDF Table

      245

    • Figure 9-147CCDF Table in Windowed Display

      245

    • Figure 9-148CCDF Table in Expanded Display

      246

    • Figure 9-149CCDF Table in Full-Screen Display

      247

    • Setting the CCDF Trace

      248

    • Figure 9-150Trace Display Select Control Menu

      248

    • Figure 9-151CCDF Trace Display with Marker Trace Menu

      249

    • Figure 9-152Scale/DIV Pop-Up

      251

    • Figure 9-153Selection of CCDF Trace to be Stored as a Reference Trace

      252

  • 10 Maintenance

    253

    • Self Test

      254

    • Figure 10-154Self Test Complete

      255

    • Test Descriptions

      256

    • Error Messages

      258

    • Figure 10-155Error Indicator Position

      258

    • Error Message List

      260

    • Operator Maintenance

      269

    • Figure 10-156Replacing the Fuse

      270

    • Contacting Agilent Technologies

      271

    • Erasing Memory Data

      274

    • Figure 10-157Secure Erase Status Pop-Up

      274

    • Returning Your Power Meter for Service

      275

    • Agilent Sales and Service Offices

      277

  • 11 Specifications and Characteristics

    280

    • Introduction

      280

    • Power Meter Specifications

      282

    • Remote Programming

      284

    • Measurement Characteristics

      285

    • Figure 11-158Measured Rise Time Percentage Error Versus Signal under Test Rise Time

      287

    • Rear Panel Inputs and Output Connections

      288

    • Mw Power Reference

      289

    • Environmental Conditions

      290

    • Physical Characteristics

      291

    • Regulatory Information

      292

    • System Specifications and Characteristics

      293

    • Figure 11-159P-Series Sensor Error in Peak-To-Average Measurements for a Two-Tone Input

      294

Agilent Technologies N1912A Configuration Manual

Agilent Technologies N1912A Configuration Manual (5 pages)

P-Series Power Meters and Wideband Power Sensors

Brand: Agilent Technologies
|
Category: Measuring Instruments
|
Size: 0.12 MB

Table of Contents
  • Calibration Option

    3

  • Cable Accessories

    3

  • Software Accessories

    3

  • Literature References

    4

Advertisement

Advertisement

Related Products

  • Agilent Technologies N1911A

  • Agilent Technologies N1913a

  • Agilent Technologies N1914a

  • Agilent Technologies N1996A-503

  • Agilent Technologies N1996A-506

  • Agilent Technologies N5230A

  • Agilent Technologies N5242A

  • Agilent Technologies N3383A

  • Agilent Technologies N9000A

  • Agilent Technologies N9010AK-REA

Agilent Technologies Categories

Measuring Instruments

Laboratory Equipment

Test Equipment

Water Pump

Power Supply
Power Supply

More Agilent Technologies Manuals

Производителю ВЧ аппаратуры необходима уверенность, что выпускаемые им изделия имеют характеристики, которые удовлетворяют потребности заказчика. Сегодня разработка и производство ВЧ и микроволновых систем выдвигает требования к испытанию все более широкополосных сигналов и точным измерениям мощности в импульсе, чего не могут обеспечить измерители средней мощности. Одноканальные и двухканальные измерители мощности серий Agilent P, EPM и EPM.P с абсолютной погрешностью измерения ±0,2 дБ (±0,5 %) обеспечивают достоверные результаты при испытании современных радиоэлектронных систем, в том числе использующих широкополосные сигналы.

Серия P: измерение пиковой и средней мощности широкополосных сигналов
Измерители мощности серии P (N1911A и N1912A) совместно с семейством первичных преобразователей мощности (в дальнейшем — преобразователи) компании Agilent обеспечивают быстрые, точные и повторяющиеся измерения, необходимые в процессе НИОКР и производства аппаратуры аэрокосмической и оборонной техники, систем радиосвязи и сетей стандарта 802.11a/b/g, обеспечивая потребности радиолокации и испытания компонентов импульсной техники и усилителей многочастотных систем. Измерители мощности серии P совместно с преобразователями обеспечивают всеобъемлющие измерения мощности, временные и статистические измерения, включая измерения пиковой, средней и отношения пиковой к средней мощности, максимальной и минимальной мощности, в том числе с временным стробированием и с автономным запуском, измерение длительности фронта и среза и дополняющей интегральной функции распределения (CCDF). Непрерывная дискретизация с частотой до 100 МГц и самая широкая среди приборов этого класса полоса видеотракта 30 МГц позволяют захватывать повторяющиеся и однократные широкополосные сигналы. Совместимость со всеми преобразователями компании Agilent серии 8480 и серии E обеспечивает дополнительный выбор для измерения средней мощности в широком динамическом диапазоне и диапазоне частот от 9 кГц до 110 ГГц.

Серия EPM-P: многоцелевое назначение и высокая производительность
Измерители мощности серии EPM-P (E4416A и E4417A) совместно с семейством первичных преобразователей мощности Agilent E9320 имеют моноблочную конструкцию и обеспечивают измерение пиковой, отношения пиковой к средней и средней мощности, в том числе с использованием временного стробирования. Широкие возможности запуска упрощают просмотр интересующих фрагментов сигнала.

Серия EPM: достоверные измерения средней мощности
Если у пользователя возникает необходимость измерения средней мощности, недорогие измерители серии EPM (E4418B и E4419B) обеспечат получение точных и повторяющихся результатов.

Особенности измерителя мощности N1912A

  • Интуитивно-понятные операции для быстрой установки режима и получения достоверных результатов
  • Восемь встроенных конфигураций для испытания систем радиосвязи, включая Bluetooth
  • Графический дисплей плюс экран анализа с возможностью реальновременных измерений дельта»маркером интервалов времени, пикового, среднего значений мощности и отношения пикового к среднему
  • Программное обеспечение для анализа параметров импульсов и статистического анализа

  1. Manuals
  2. Brands
  3. Agilent Technologies Manuals
  4. Measuring Instruments
  5. 1912A

Manuals and User Guides for Agilent Technologies 1912A. We have 2 Agilent Technologies 1912A manuals available for free PDF download: Programming Manual, User Manual

AGILENT TEСHNOLOGIES N1912A – Измеритель мощности

Назначение и особенности измерителя мощности N 1912 A

Двухканальный измеритель мощности N 1912A с преобразователями мощности N192xA обеспечивает широкополосные высококачественные измерения, которые необходимы при проверки соответствия продукции требованиям по мощности.

Особенности измерителя мощности N1912 A

  • Полоса пропускания видеосигнала 30 МГц;
  • Дискретизация в реальном масштабе времени однократных процессов со скоростью 100 миллионов выборок в секунду;
  • Установка нуля и калибровка при подключенном к контролируемому устройству приборе;
  • Измерения максимальной, средней мощности и отношения максимальной мощности к средней мощности, временные измерения длительности фронта, длительности спада, длительности импульса, периода повторения импульсов, коэффициента заполнения, времени появления положительного и отрицательного значения и статистический анализ при помощи дополняющей интегральной функции распределения (CCDF);
  • Простая организация измерений с 22 предварительными установками, включающими WiMAX и WLAN;
  • Возможность подключения к USB, локальной сети и GPIB;
  • Измерения максимальной, средней мощности и отношения максимальной мощности к средней мощности;
  • Режимы свободных и стробированных во времени измерений;
  • Автоматическое измерение длительности фронта, длительности спада, времени до появления положительного значения и времени до появления отрицательного значения.

Технические характеристики измерителя мощности N1912A

Общие данные

Число каналов

2

Диапазон частот

от 50 МГц до 40 ГГц

Максимальная частота дискретизации

100 миллионов выборок в секунду, непрерывная дискретизация

Полоса пропускания видеосигнала

Не менее 30 МГц

Полоса пропускания одиночного перепада

Не менее 30 МГц

Длительность фронта

Не более 13 нс (для частот > 500 МГц)

Длительность спада

Не более 13 нс (для частот > 500 МГц)

Минимальная длительность импульса

50 нс

Динамический диапазон

от −35 до +20 дБм (> 500 МГц); от −30 до +20 дБм (50 −500 МГц)

Максимальная длительность захваченного сигнала

1 секунда

Максимальная частота повторения импульсов

10 МГц ( при 10 выборках на периоде)

Погрешность

10х10-6

Джиттер

Не более 1 нс

Габаритные размеры

88,5 мм В х 212,6 мм Ш х 348,3 мм Г

Масса нетто

не более 3,7 кг

Масса в упаковке

не более 8 кг

Комплектация измерителя мощности N1912A

  • Измеритель N1912A;
  • Транспортный ящик основного прибора;
  • Сумка для принадлежностей;
  • Руководство по эксплуатации.

Технические параметры (спецификация) и комплект поставки товара могут быть изменены производителем без предварительного уведомления.

Информация носит справочный характер и не является публичной офертой, определяемой положениями Статьи 437 Гражданского кодекса Российской Федерации.

Документы, файлы, паспорт, инструкция N1912A

N1912A Измеритель мощности серии P, два канала от 3мкВт до 100 мВт

Измерители мощности Agilent Technologies серий EPM и EPM-P и P

  • Интуитивно»понятные операции для быстрой установки режима и получения достоверных результатов
  • Восемь встроенных конфигураций для испытания систем радиосвязи, включая Bluetooth
  • Графический дисплей плюс экран анализа с возможностью реальновременных измерений дельта»маркером интервалов времени, пикового, среднего значений мощности и отношения пикового к среднему
  • Программное обеспечение для анализа параметров импульсов и статистического анализа

Производителю ВЧ аппаратуры необходима уверенность, что выпускаемые им изделия имеют характеристики, которые удовлетворяют потребности заказчика. Сегодня разработка и производство ВЧ и микроволновых систем выдвигает требования к испытанию все более широкополосных сигналов и точным измерениям мощности в импульсе, чего не могут обеспечить измерители средней мощности. Одноканальные и двухканальные измерители мощности серий Agilent P, EPM и EPM.P с абсолютной погрешностью измерения ±0,2 дБ (±0,5 %) обеспечивают достоверные результаты при испытании современных радиоэлектронных систем, в том числе использующих широкополосные сигналы.

Серия P: измерение пиковой и средней мощности широкополосных сигналов

Измерители мощности серии P (N1911A и N1912A) совместно с семейством первичных преобразователей мощности (в дальнейшем — преобразователи) компании Agilent обеспечивают быстрые, точные и повторяющиеся измерения, необходимые в процессе НИОКР и производства аппаратуры аэрокосмической и оборонной техники, систем радиосвязи и сетей стандарта 802.11a/b/g, обеспечивая потребности радиолокации и испытания компонентов импульсной техники и усилителей многочастотных систем. Измерители мощности серии P совместно с преобразователями обеспечивают всеобъемлющие измерения мощности, временные и статистические измерения, включая измерения пиковой, средней и отношения пиковой к средней мощности, максимальной и минимальной мощности, в том числе с временным стробированием и с автономным запуском, измерение длительности фронта и среза и дополняющей интегральной функции распределения (CCDF). Непрерывная дискретизация с частотой до 100 МГц и самая широкая среди приборов этого класса полоса видеотракта 30 МГц позволяют захватывать повторяющиеся и однократные широкополосные сигналы. Совместимость со всеми преобразователями компании Agilent серии 8480 и серии E обеспечивает дополнительный выбор для измерения средней мощности в широком динамическом диапазоне и диапазоне частот от 9 кГц до 110 ГГц.

Технические характеристики измерителя мощности N1912A:

Общие данные
Число каналов 2
Диапазон частот от 50 МГц до 40 ГГц
Максимальная частота дискретизации 100 миллионов выборок в секунду, непрерывная дискретизация
Полоса пропускания видеосигнала Не менее 30 МГц
Полоса пропускания одиночного перепада Не менее 30 МГц
Длительность фронта Не более 13 нс (для частот > 500 МГц)
Длительность спада Не более 13 нс (для частот > 500 МГц)
Минимальная длительность импульса 50 нс
Динамический диапазон от −35 до +20 дБм (> 500 МГц); от −30 до +20 дБм (50 −500 МГц)
Максимальная длительность захваченного сигнала 1 секунда
Максимальная частота повторения импульсов 10 МГц ( при 10 выборках на периоде)
Погрешность 10х10-6
Джиттер Не более 1 нс
Габаритные размеры 88,5 мм В х 212,6 мм Ш х 348,3 мм Г
Масса нетто не более 3,7 кг
Масса в упаковке не более 8 кг

Комплектация измерителя мощности N1912A:

  • Измеритель N1912A;
  • Транспортный ящик основного прибора;
  • Сумка для принадлежностей;
  • Руководство по эксплуатации.
Agilent N1911A 1 канал, пиковая и средняя мощность, от 3мкВт до 100 мВт По запросу

На любые вопросы о приборе Измеритель мощности Agilent N1912A, его цене и наличию вам всегда ответят наши специалисты по телефонам +7 (495) 504-37-31 и +7 (812) 309-05-16

Понравилась статья? Поделить с друзьями:
  • Agilent 34401a инструкция на русском
  • Agilent 1260 infinity ii инструкция на русском
  • Agi max ботокс инструкция по применению
  • Agfa cr 10 x инструкция
  • Agestar 3ubt8 инструкция по клонированию