Page 2
Type 8692, 8693 Positioner Electropneumatic positioner Operating Instructions Bedienungsanleitung Manuel d‘ utilisation… -
Page 3
We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous resérve de modification techniques. © 2008 Bürkert Werke GmbH & Co. KG Operating Instructions 0804/00_EU-ML_00806169… -
Page 4
Electrical Connection — Multipole Plug Model ……………………….42 Electrical Connection — Terminal Model for Cable Gland ………………….45 Initial Start-up ………………………………….48 START-UP AND OPERATION OF THE POSITION CONTROLLER TYPE 8692 ……………….51 Safety instructions ………………………………..53 Starting up and installing the position controller Type 8692 …………………54 Operation of the position controllerS …………………………60… -
Page 5
Configuration of the Process Data…………………………..148 Bus Status Display ………………………………..151 Configuration Example 1 ………………………………152 Configuration Example 2 ………………………………155 SERVICING AND TROUBLESHOOTING THE POSITION CONTROLLER TYPE 8692 …………..157 Maintenance ………………………………….158 Error Messages and Malfunctions……………………………158 SERVICING AND TROUBLESHOOTING THE PROCESS CONTROLLER TYPE 8693 …………..161 Maintenance ………………………………….162… -
Page 6
Adjustment rules for PID Controllers …………………………175 OPERATING STRUCTURE OF THE POSITIONER (APPENDIX) ………………….179 Operating Structure of the Positioner …………………………180 POSITION CONTROLLER TABLE TYPE 8692 (APPENDIX) ……………………187 Table for Your Settings on the Position Controller ……………………188 PROCESS CONTROLLER TABLE TYPE 8693 (APPENDIX) ……………………189 Table for Your Settings on the Process Controller ……………………190… -
Page 7
Type 8692, 8693 Table of Contents english… -
Page 8
Type 8692, 8693 General Information Safety Instructions General Information and Safety Instructions ABLE OF ONTENTS THE OPERATING INSTRUCTIONS …………………………….. 8 Symbols …………………………………….. 8 INTENDED USE ……………………………………9 Restrictions ……………………………………9 Foreseeable Misuse ………………………………..9 GENERAL SAFETY INSTRUCTIONS …………………………….10 GENERAL INFORMATION ………………………………..11 Scope of supply …………………………………..11… -
Page 9
Type 8692, 8693 General Information Safety Instructions 1 THE OPERATING INSTRUCTIONS The operating instructions describe the entire life cycle of the device. Keep these instructions in a location which is easily acces- sible to every user and make these instructions available to every new owner of the device. -
Page 10
If exporting the system/device, observe any existing restrictions. 2.2 Foreseeable Misuse • The positioner Type 8692 and Type 8693 must not be used in areas where there is a risk of explosion. • Do not introduce any aggressive or flammable media into the system’s media connections. -
Page 11
Also ensure that you do not touch electronic components when the power supply voltage is present! The positioners Type 8692 and Type 8693 were developed with due consideration given to the accepted safety rules and are state-of-the-art. However, dangers can still arise. -
Page 12
This document does not offer any form of warranty. Please refer to our general terms of sales and business. The warranty is only valid if the positioner Type 8692 and Type 8693 is used as intended in accordance with the specified application conditions. -
Page 13
Type 8692, 8693 General Information Safety Instructions english… -
Page 14
Features ……………………………………17 Function diagram of the positioner with single-acting actuator ……………….18 TYPE 8692 POSITIONER WITH POSITION CONTROLLER ……………………19 Schematic representation of the positioner Type 8692 ………………….20 Properties of the position controller software ……………………..21 TYPE 8693 POSITIONER WITH PROCESS CONTROLLER ……………………22 Schematic representation of the process control ……………………23… -
Page 15
1 FUNCTION OF THE POSITIONER AND COMBINATION WITH VALVE TYPES Positioners Type 8692 and Type 8693 are electropneumatic positioner for pneumatically actuated control valves with single- acting or double-acting actuators. Together with the pneumatic actuator the positioner forms an optical and functional unit. -
Page 16
Type 8692, 8693 Description of System Pneumatically actuated piston actuators and rotary actuators can be used as a actuator. Both single-acting and double-acting actuators are offered in combination with the positioner. For single-acting actuators, only one chamber is aerated and deaerated during actuation. The generated pressure works against a spring. -
Page 17
Description of System 2 STRUCTURE OF THE POSITIONER The positioners Type 8692 and Type 8693 consist of the micro-processor controlled electronics, the position measuring system and the control system. The appliance is designed using three-wire technology. Operation of the positioner is controlled by four keys and a 128×64 dot matrix graphic display. -
Page 18
Type 8692, 8693 Description of System 2.2 Features • Models for single-acting or double-acting valve actuators. • Position measuring system Non-contact and therefore non-wearing position measuring system. • Microprocessor-controlled electronics for signal processing, control and valve control. • Control module Operation of the device is controlled by four keys. -
Page 19
Description of System 2.3 Function diagram of the positioner with single-acting actuator The black lines describe the function of the position controller (Type 8692). The process controller (Type 8693) includes the position controller and the functions which are illustrated in grey. -
Page 20
Type 8692, 8693 Description of System 3 TYPE 8692 POSITIONER WITH POSITION CONTROLLER The position measuring system records the current position (POS) of the pneumatic actuator. The position controller compares this actual position value with the set-point value (CMD), which is definable as norm signal. In case of a control deviation (Xd1), a pulse-width modulated voltage signal is sent to the control system as a manipulated variable. -
Page 21
Type 8692, 8693 Description of System 3.1 Schematic representation of the positioner Type 8692 Fig. 5: Schematic representation of position control english… -
Page 22
Type 8692, 8693 Description of System 3.2 Properties of the position controller software Additional function Action Position controller with additional function Sealing function Valve closes tight outside the control range. Specification of the value (in %), from which the actuator is completely de- CUTOFF aerated (when 0%) or aerated (when 100%). -
Page 23
Type 8692, 8693 Description of System 4 TYPE 8693 POSITIONER WITH PROCESS CONTROLLER If the positioner is operated with process controller Type 8693, the aforementioned position control becomes the subordinate auxiliary control circuit; this results in a cascade control. The process controller in the main control circuit of the positioner has a PID function. -
Page 24
Type 8692, 8693 Description of System 4.1 Schematic representation of the process control Fig. 7: Schematic representation of process control english… -
Page 25
Type 8692, 8693 Description of System 4.2 Properties of the process controller software Additional function Action Position controller with additional function Sealing function Valve closes tight outside the control range. Specification of the value (in %), from which the actuator is completely deaerated CUTOFF (when 0%) or aerated (when 100%). -
Page 26
Frequency Pt100 Binary input 24 V DC Operation Fig. 10: Interfaces for the multipole model The positioners Type 8692 and Type 8693 are 3-wire devices, i.e. the power (24 V DC) is supplied separately from the set-point value signal. english… -
Page 27
Operation Fig. 11: Interfaces for the model with cable gland The positioners Type 8692 and Type 8693 are 3-wire devices, i.e. the power (24 V DC) is supplied separately from the set-point value signal. *Type 8693: The switch can be used to supply power to a connected sensor… -
Page 28
Type 8692, 8693 Description of System 7 TECHNICAL DATA Safety positions after failure of the electrical or pneumatic auxiliary power Safety positions after failure of the auxiliary power Actuator system Designation electrical pneumatic single-acting down down control function A down… -
Page 29
Type 8692, 8693 Description of System 7.2 Factory settings of the positioner Function Factory setting Function Factory setting ACTUATOR SINGLE or DOUBLE* X.CONTROL DBND 1.0 % INPUT 4-20 mA KXopn (1) Values of X.TUNE determined KXcls (1) Values of X.TUNE determined… -
Page 30
Type 8692, 8693 Description of System 7.3 Specifications of the Positioner 7.3.1 Operating Conditions CAUTION! If used outside, the device may be exposed to direct sunlight and temperature fluctuations which may cause mal- functions or leaks! • The device must not be used outside. -
Page 31
Type 8692, 8693 Description of System 7.3.5 Pneumatic Data Control medium Quality classes in accordance with DIN ISO 8573-1 Dust content Class 5 max. particle size 40 µm, max. particle density 10 mg/m³ Water content Class 3 max. pressure dew point — 20 °C or min. -
Page 32: Table Of Contents
Configuration of the keys ………………………………33 Information on the Display ……………………………..34 OPERATING MODES ………………………………….35 Operating state ………………………………….35 AUTOMATIC Operating State for Type 8692 ……………………….35 AUTOMATIC Operating State for Type 8693 ……………………….36 MANUAL Operating State ……………………………….37 OPERATING LEVELS ………………………………….38 Switching between the Operating Levels ……………………….38…
-
Page 33: Control And Display Elements
Further information on the control of the positioner can be found in the chapters entitled “Installation”, “Start-up and operation of the position controller Type 8692” and “Start-up and operation of the process controller Type 8693”. 1.1 Control and display elements of the positioner…
-
Page 34: Configuration Of The Keys
Type 8692, 8693 Control and display elements, operating modes 1.2 Configuration of the keys The assignment of the 4 keys on the control panel differs depending on the operating status (AUTOMATIC / MANUAL) or operating level (Operate process / Parameterization and Configuration) of the positioner.
-
Page 35: Information On The Display
Type 8692, 8693 Control and display elements, operating modes 1.3 Information on the Display The following representation describes the information on the display: Description of the Display for AUTOMATIC mode: value Bar running from left to right Value Unit or percent-…
-
Page 36: Operating Modes
Type 8693. On the SP display only for external process set-point value (see also Configuration of the keys). 2.2 AUTOMATIC Operating State for Type 8692 (Bar runs along the upper edge of the display from left to right) Normal controller mode is implemented and monitored in AUTOMATIC operating state.
-
Page 37: Automatic Operating State For Type 8693
MENU POS INPUT* If the P.CONTROL additional function is not active, the displays are represented as under Type 8692. * INPUT is indicated here if the internal nominal value default has been selected (P.CONTROL — SP-INPUT — internal). MANU is indicated here if the external nominal value default has been selected (P.CONTROL — SP-INPUT — external).
-
Page 38: Manual Operating State
Type 8692, 8693 Control and display elements, operating modes 2.4 MANUAL Operating State (no bar running along upper edge of display) In MANUAL operating state the valve can be opened and closed manually via the arrow keys. Meaning of the arrow keys in MANUAL operating state:…
-
Page 39: Operating Levels
Type 8692, 8693 Control and display elements, operating modes 3 OPERATING LEVELS The menu structure in the control module of the positioner contains 2 operating levels: • Level 1: Operate process → Operating mode AUTOMATIC Process / input data displayed →…
-
Page 40
FLUID CONNECTION OF THE POSITIONER …………………………41 ELECTRICAL CONNECTION — MULTIPOLE PLUG MODEL ……………………42 Type 8692 — Designation of the multipole plugs and the contacts ………………42 Connection of the Position Controller Type 8692 ……………………..43 4.2.1 Input signals of the control centre (e.g. PLC) — circular plug M 12 — 8-pole …………43 4.2.2 Output signals to the control centre (e.g. -
Page 41: Installing The Valve
Type 8692, 8693 Installation 1 INSTALLING THE VALVE 1.1 Safety Instructions DANGER! Danger – high pressure in the equipment! There is a serious risk of injury when reaching into the equipment. • Before loosening the lines and valves, turn off the pressure and vent the lines.
-
Page 42: Fluid Connection Of The Positioner
Type 8682, 8693 Installation 3 FLUID CONNECTION OF THE POSITIONER DANGER! Danger – high pressure in the equipment! There is a serious risk of injury when reaching into the equipment. • Before loosening the lines and valves, turn off the pressure and vent the lines. WARNING! Danger — improper installation! Improper installation may result in injuries as well as damage to the device and the area around it.
-
Page 43: Electrical Connection — Multipole Plug Model
If PROFIBUS DP or DeviceNet:The designation of the multipole plugs and sockets and the contacts can be found in the respective chapters. 4.1 Type 8692 — Designation of the multipole plugs and the contacts Output signals to PLC Operating voltage…
-
Page 44: Connection Of The Position Controller Type 8692
When the power supply voltage is applied, the positioner is operating. → Now implement the required basic settings and activate automatic adjustment of the positioner as described in the chapter entitled “Initial Start-up” or “Starting and Setting Up the Position Controller Type 8692”. english…
-
Page 45: Type 8693 — Designation Of The Multipole Plugs And The Contacts
Fig. 3: Designation of the multipole plugs and contacts 8693 4.4 Connection of the Process Controller Type 8693 → First connect the process controller as described in the chapter entitled “4.2 Connecting the Position Controller Type 8692”. 4.4.1 Process Actual Value (circular plug M Input type*…
-
Page 46: Electrical Connection — Terminal Model For Cable Gland
The connection terminals can be accessed by removing the cover from the cable glands. To do this, unscrew the 4 screws. → Connect the positioner accordingly: Type 8692: see chapter entitled “Terminal Assignment for Cable Gland — Position Controller Type 8692” Type 8693: see chapter entitled “Terminal Assignment for Cable Gland — Process Controller Type 8693” english…
-
Page 47: Terminal Assignment For Cable Gland — Position Controller Type 8692
When the power supply voltage is applied, the positioner is operating. → Now implement the required basic settings and activate automatic adjustment of the positioner as described in the chapter entitled “Initial Start-up” or “Starting and Setting Up the Position Controller Type 8692”. english…
-
Page 48: Terminal Assignment For Cable Gland — Process Controller Type 8693
5.3 Terminal Assignment for Cable Gland — Process Controller Type 8693 → First connect the process controller as described in the chapter entitled “ 5.2 Terminal Assignment for Cable Gland — Posi- tion Controller Type 8692”. 5.3.1 Terminal Assignment when Selecting the Process Actual Value Input Input type* Switch**…
-
Page 49: Initial Start-Up
Type 8692, 8693 Installation 6 INITIAL START-UP This section enables you to start up the positioner quickly in order to perform a function check. Additional functions which are not required are not dealt with in this context. 6.1 Safety Instructions DANGER! Danger –…
-
Page 50: Setting The Input Signal (Standard Signal)
6.3.2 Running the Automatic Adjustment X.TUNE: An exact description of the X.TUNE function can be found in the chapters entitled «Start-up and Operating the Position Controller Type 8692» WARNING! While the X.TUNE function is running, the valve automatically moves from its current position! •…
-
Page 51: Overview Of Operating Structure Initial Start-Up
Type 8692, 8693 Installation 6.3.3 Overview of Operating Structure Initial Start-up Operate process Configuration Selection menu Main menu (ACTUATOR, INPUT, …) MAIN Operating state approx. 3s MENU AUTOMATIC ACTUATOR Operating mode of the actua- tor preset at the factory MANUAL…
-
Page 52
Start-up and operation of the position controller Type 8692 ABLE OF ONTENTS SAFETY INSTRUCTIONS ………………………………..53 STARTING UP AND INSTALLING THE POSITION CONTROLLER TYPE 8692 …………….54 Description of the procedure …………………………….54 Factory settings of the position controller ……………………….55 Specifying the Basic Settings…………………………….55 Description of the basic functions in the main menu ……………………56… -
Page 53
CHARACT Select the transfer characteristic between input signal (position set-point value) and stroke . 4.3.2 CUTOFF Sealing function for the position controller Type 8692 …………..71 4.3.3 DIR.CMD Effective sense of direction of the position controller set-point value ……… 72 4.3.4… -
Page 54: Safety Instructions
Type 8692, 8693 Start-up, operation position controller Type 8692 1 SAFETY INSTRUCTIONS DANGER! Danger – high pressure in the equipment! There is a serious risk of injury when reaching into the equipment. • Before loosening the lines and valves, turn off the pressure and vent the lines.
-
Page 55: Starting Up And Installing The Position Controller Type 8692
Type 8692, 8693 Start-up, operation position controller Type 8692 2 STARTING UP AND INSTALLING THE POSITION CONTROLLER TYPE 8692 → Before starting up the device, carry out the fluid and electrical installations as described in the chapter entitled “Installation”. 2.1 Description of the procedure When the operating voltage has been switched on, the positioner is at the process operating level in the AUTOMATIC operat- ing state.
-
Page 56: Factory Settings Of The Position Controller
Type 8692, 8693 Start-up, operation position controller Type 8692 2.2 Factory settings of the position controller Function Factory setting Function Factory setting ACTUATOR SINGLE or DOUBLE* X.CONTROL DBND 1.0 % INPUT 4-20 mA KXopn (1) Values of X.TUNE determined KXcls (1) Values of X.TUNE determined…
-
Page 57: Description Of The Basic Functions In The Main Menu
Type 8692, 8693 Start-up, operation position controller Type 8692 2.4 Description of the basic functions in the main menu 2.4.1 Main menu of the positioner Operate process Configuration Main menu Selection menu (ACTUATOR, INPUT, …) MAIN Operating state approx. 3s…
-
Page 58: Inputting The Operating Mode Of The Pneumatic Actuator
Type 8692, 8693 Start-up, operation position controller Type 8692 2.4.2 Inputting the operating mode of the pneumatic actuator ACTUATOR — Operating mode of the actuator The operating mode of the pneumatic valve actuator used in combination with the positioner can be input in this menu option.
-
Page 59: Automatic Adjustment (Autotune) Of The Position Controller
Type 8692, 8693 Start-up, operation position controller Type 8692 2.4.4 Automatic adjustment (autotune) of the position controller X.TUNE — Autotune for position controller WARNING! While the X.TUNE function is running, the valve automatically moves from its current position! • Never run X.TUNE while a process is running!
-
Page 60: Adding Auxiliary Functions
Type 8692, 8693 Start-up, operation position controller Type 8692 2.4.5 Adding auxiliary functions ADD.FUNCTION With ADD.FUNCTION auxiliary functions can be included in the main menu. See chapter entitled «Configuration of auxiliary functions». → Skip this menu option during the initial start-up.
-
Page 61: Operation Of The Position Controllers
Type 8692, 8693 Start-up, operation position controller Type 8692 3 OPERATION OF THE POSITION CONTROLLERS A precise description of the control and display elements, as well as the configuration of the keys can be found in the chapter entitled «Control and display elements».
-
Page 62: Automatic Operating State
Type 8692, 8693 Start-up, operation position controller Type 8692 3.3 AUTOMATIC operating state Bar running from left to right along the upper edge of the display. Normal control mode is implemented and monitored in AUTOMATIC operating state. 3.3.1 Meaning of the keys…
-
Page 63: Manual Operating State
Type 8692, 8693 Start-up, operation position controller Type 8692 3.4 MANUAL operating state Without bar running from left to right along the upper edge of the display. In MANUAL operating state the valve can be opened or closed manually. 3.4.1 Meaning of the keys…
-
Page 64: Configuring The Auxiliary Functions
Type 8692, 8693 Start-up, operation position controller Type 8692 4 CONFIGURING THE AUXILIARY FUNCTIONS The operating concept for the positioner is based on a strict division between basic and auxiliary functions. When the device is delivered, only the basic functions are activated. They are used during the initial start-up to implement basic settings specific to the device.
-
Page 65: Configuration Menu
Type 8692, 8693 Start-up, operation position controller Type 8692 4.2 Configuration menu 4.2.1 Switching between Process operating level and Configuration level left selection key >3s MENU Process operating level Configuration level MANUAL AUTOMATIC Basic Auxiliary functions functions left selection key EXIT Fig.
-
Page 66: Principle Of Including Auxiliary Functions In The Main Menu
Type 8692, 8693 Start-up, operation position controller Type 8692 SET VALUE y 0 -> : Previously set value Changeable value Accept the set value Reduce value Increase value Return without change SET VALUE Access Code: 0000 Changeable number <- Accept the set value…
-
Page 67: Spltrng Signal Split Range
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3 Auxiliary functions Overview of auxiliary functions for the position controller Type 8692 ENTER Selection of the transfer characteristic between input CHARACT ADD.FUNCTION signal and stroke (correction characteristic) Sealing function for position controller…
-
Page 68
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.1 CHARACT Select the transfer characteristic between input signal (position set-point value) and stroke Characteristic (customer-specific characteristic) Use this auxiliary function to select a transfer characteristic with reference to set-point value (nominal position, CMD) and valve stroke (POS) for correction of the flow or operating characteristic. -
Page 69
Type 8692, 8693 Start-up, operation position controller Type 8692 Standardised valve stroke [%] (POS) In the case of control tasks for closed-loop control systems it is usually particular demands which are placed on the course of the operating characteristic, e.g. linearity. For this reason it is occasionally necessary to correct the course of the operating characteristic in a suitable way. -
Page 70
Type 8692, 8693 Start-up, operation position controller Type 8692 Procedure: → To input the characteristic points (function values), select the FREE sub-menu option using the arrow keys and confirm by pressing the selection key on the right (SELEC). Another sub-menu (FREE) opens in which the individual nodes are listed (as %). -
Page 71
Type 8692, 8693 Start-up, operation position controller Type 8692 Example of a programmed characteristic Valve stroke [&] (POS) Unit signal [%] (CMD) 90 100 4 … 20 mA 0 … 20 mA 0 … 10 V 0 … 5 V Fig. -
Page 72
4.3.2 CUTOFF Sealing function for the position controller Type 8692 The sealing function for the process controller Type 8693 can be found in the chapter entitled «Start-up, operation of the process controller Type 8693» — «Auxiliary functions for the process controller». -
Page 73
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.3 DIR.CMD Effective sense of direction of the position controller set-point value Use this auxiliary function to set the effective sense of direction between the input signal (INPUT) and the nominal position (CMD) of the actuator. -
Page 74
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.4 DIR.ACT Effective sense of direction of the actuator Use this auxiliary function to set the effective sense of direction between the aeration state of the actuator and the actual posi- tion (POS). -
Page 75
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.5 SPLTRNG Signal split range Min. and max. values of the input signal as % for which the valve runs through the entire stroke range. Factory setting: Min = 0 %;… -
Page 76
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.6 X.LIMIT Lmits the mechanical stroke range This auxiliary function limits the (physicali) stroke to specified % values (minimum and maximum). In doing so, the stroke range of the limited stroke is set equal to 100 %. If the limited stroke range is left during operation, negative POS values or POS values are indicated greater than 100 %. -
Page 77
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.7 X.TIME Limiting the control speed Use this auxiliary function to specify the opening and closing times for the entire stroke and limit the control speeds. When the X.TUNE function is running, the minimum opening and closing time for the entire stroke is automatically entered for Open and Close. -
Page 78
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.8 X.CONTROL Parameterisation of the position controller Use this function to set the parameters for the position controller (dead band and amplification factors). ENTER INPUT X.CONTROL DBND DBND INPUT KXopn KXopn… -
Page 79
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.9 SECURITY Code protection for the settings Use the SECURITY function to prevent the positioner or individual functions from being accessed unintentionally. Factory setting: Access Code: 0000 If the code protection is activated, the code (set access code or master code) must be input whenever operator action is disabled. -
Page 80: Safepos Input The Safety Position
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.10 SAFEPOS Input the safety position This function specifies the actuator safety position which is started at defined signals. The set safety position is not started unless there is a corresponding signal at the binary input (for configuration see BINARY-IN) or if a signal error occurs (for configuration see SIG-ERROR).
-
Page 81: Sig-Error Configuration Of Signal Level Fault Detection
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.11 SIG-ERROR Configuration of signal level fault detection The SIG-ERROR function is used to detect a fault on the input signal. Fault detection Fault detection can be selected at 4 – 20 mA signal only: Fault with input signal ≤…
-
Page 82: Binary-In Activation Of The Binary Input
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.12 BINARY-IN Activation of the binary input This function activates the binary input. The following settings can be implemented for this: • Approaching the safety position • Switching over the MANUAL/AUTOMATIC operating mode…
-
Page 83: Output (Option) Configuring The Outputs
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.13 OUTPUT (option) Configuring the outputs The OUTPUT menu option is only indicated in the selection menu of ADD.FUNCTION if the positioner has outputs (option). The outputs can be used for the following feedback signals: Analogue output: Feedback signal of the current position (POS) or of the set-point value (CMD) to the control centre.
-
Page 84
Type 8692, 8693 Start-up, operation position controller Type 8692 OUT ANALOG — Configuration of the analogue output Only for the versions: • one analogue output • one analogue and two binary outputs The feedback signal of the current position (POS) or of the set-point value (CMD) can be transmitted to the control centre via the analogue output. -
Page 85
Type 8692, 8693 Start-up, operation position controller Type 8692 OUT BIN1 — Configuration of the binary output 1 OUT BIN2 — Configuration of the binary output 2 The following description is valid for both binary outputs OUT BIN 1 and OUT BIN 2, as the operation in the menu is identical. -
Page 86
Type 8692, 8693 Start-up, operation position controller Type 8692 Alarm output for excessively large control deviation of the position controller: OUT DEV.X → Press the arrow keys to mark the OUT DEV.X menu option and confirm with the selection key on the right (SELEC). -
Page 87
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.14 CAL.USER Calibrating the actual value display and the inputs for the position set-point value The following points can be manually calibrated with this function: • Position display ( POS) 0 – 100% •… -
Page 88: Set.factory Resetting To The Factory Settings
Type 8692, 8693 Start-up, operation position controller Type 8692 Procedure: Calibrating the actual value display POS (0 — 100 %): calibr. POS → In the CAL. USER menu press the arrow keys to select the calibr. POS menu option and confirm with the selection key on the right (ENTER).
-
Page 89: Ser. IO Settings Of The Serial Interface
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.16 SER. IO Settings of the serial interface This function can be used to set the type of the serial interface and the baud rate. ENTER SELEC ENTER SER. IO BAUD-RATE…
-
Page 90: Extras
Type 8692, 8693 Start-up, operation position controller Type 8692 4.3.17 EXTRAS This function can be used to set the representation on the display. SELEC ENTER ENTER Black font on light EXTRAS normal DISPLAY background EXIT White font on dark invers background Fig.
-
Page 91
Type 8692, 8693 Start-up, operation position controller Type 8692 english… -
Page 92
Type 8692, 8693 Start-up, operation process controller Type 8693 Start-up and operation of the position controller Type 8693 ABLE OF ONTENTS SAFETY INSTRUCTIONS ………………………………..93 STARTING UP AND SETTING UP THE PROCESS CONTROLLER TYPE 8693 …………….93 Description of the procedure …………………………….93 Factory settings of the process controller ……………………….94… -
Page 93
Type 8692, 8693 Start-up, operation process controller Type 8693 MANUAL operating state ………………………………111 3.4.1 Meaning of the keys …………………………..111 3.4.2 Information on the Display ………………………….111 3.4.3 Operating structure …………………………..111 AUXILIARY FUNCTIONS FOR THE PROCESS CONTROLLER ………………….112 Overview of the auxiliary functions………………………….112 4.1.1 Including auxiliary functions in the main menu ………………….113… -
Page 94: Safety Instructions
Type 8692, 8693 Start-up, operation process controller Type 8693 1 SAFETY INSTRUCTIONS DANGER! Danger – high pressure in the equipment! There is a serious risk of injury when reaching into the equipment. • Before loosening the lines and valves, turn off the pressure and vent the lines.
-
Page 95: Factory Settings Of The Process Controller
FILTER The factory settings of the position controller can be found in the chapter entitled «Start-up and operation of the posi- tion controller Type 8692» — «Factory settings of the position controller». 2.3 Procedure for setting up a process control CAUTION! The process control cannot be implemented until the position controller has been automatically adjusted (X.TUNE)!
-
Page 96: Setting Up The Position Controller
The exact description of the functions INPUT and X.TUNE can be found in the chapter entitled «Start-up and opera- tion of the position controller Type 8692“ -«Description of the functions of the main menu”. The basic settings for the positioner are implemented at the factory. During start-up, however, it is essential to input the unit signal (INPUT) and run X.TUNE .
-
Page 97: Basic Settings For The P.control Function
Type 8692, 8693 Start-up, operation process controller Type 8693 2.5.2 Basic settings for the P.CONTROL function ENTER ENTER INPUT P.CONTROL PARAMETER DBND 1.00 999.9 0.0% EXIT FILTER ENTER ENTER EXIT SETUP PV INPUT PV SCALE INPUT SP SCALE* P.CO INIT EXIT Fig.
-
Page 98: Parameter Setting Of The Process Controller — Parameter
Type 8692, 8693 Start-up, operation process controller Type 8693 2.5.3 Parameter setting of the process controller — PARAMETER These positioner functions are used to specify the control parameters of the process controller. The basic principles of setting a controller can be found in the chapter entitled «General rules» — «Properties of PID controllers».
-
Page 99: Kp — Amplification Factor Of The Process Controller
Type 8692, 8693 Start-up, operation process controller Type 8693 KP — Amplification factor of the process controller The amplification factor specifies the P-contribution of the PID controller. Factory setting: 1.00 INPUT 1.00 Adjustment range: 1.00 0 – 99.99 ← (% / set unit) Fig.
-
Page 100: X0 — Working Point Of The Process Controller
Type 8692, 8693 Start-up, operation process controller Type 8693 X0 — Working point of the process controller Operating point in rest state. Factory setting: 0.0 % INPUT 0.0% Adjustment range: 0.0% 0 – 100 % Fig. 7: Operating structure P.CONTROL — X0 The «Process controller tables»…
-
Page 101: Setting Up The Process Controller — Setup
Type 8692, 8693 Start-up, operation process controller Type 8693 2.5.4 Setting up the process controller — SETUP These functions specify the type of control. PV INPUT — Indication of the signal type for the process actual value The PV INPUT function specifies the signal type of the process actual value: •…
-
Page 102: Pv-Scale — 1 — Scaling Of The Process Controller For Signal Type 4 — 20 Ma (Pv-Input 4 — 20 Ma)
Type 8692, 8693 Start-up, operation process controller Type 8693 PV-SCALE — 1 — Scaling of the process controller for signal type 4 – 20 mA (PV-INPUT 4 — 20 mA) With the PV-SCALE function for signal type 4 – 20 mA the following settings are specified: •…
-
Page 103: Pv-Scale — 2 — Scaling Of The Process Controller For Frequency Input Signal Type (Pv Input Frequency)
Type 8692, 8693 Start-up, operation process controller Type 8693 PV-SCALE — 2 — Scaling of the process controller for frequency input signal type (PV INPUT frequency) The PV-SCALE function specifies the following settings for frequency input signal type: • The unit of the process actual value.
-
Page 104
Type 8692, 8693 Start-up, operation process controller Type 8693 Upper scaling value for the process actual value PVmax X x/x Settings: The unit for flow and the position for the decimal point is transferred from the inputs of the lower scaling value. -
Page 105: Pv-Scale — 3 — Scaling Of The Process Controller For Selection Of The Pt 100 Input (Pv Input Pt 100)
Type 8692, 8693 Start-up, operation process controller Type 8693 PV-SCALE — 3 — Scaling of the process controller for selection of the Pt 100 input (PV INPUT PT 100) The PV-SCALE function specifies the following settings for the PT 100 signal type: •…
-
Page 106: Sp Input — Type Of Set-Point Value Default (Internal / External)
Type 8692, 8693 Start-up, operation process controller Type 8693 Upper scaling value for the process actual value PVmax X *X Settings: The unit for the temperature and the position for the decimal point is transferred from the inputs of the lower scaling value.
-
Page 107: Sp — Scale — Scaling Of The Position Controller
Type 8692, 8693 Start-up, operation process controller Type 8693 SP — SCALE — Scaling of the position controller This function is indicated in the selection menu only if the external set-point value default (external) has been selected in the SP INPUT menu option.
-
Page 108: Linearisation Of The Process Characteristic P.q’lin
Type 8692, 8693 Start-up, operation process controller Type 8693 2.5.5 Linearisation of the process characteristic P.Q’LIN This function automatically linearises the process characteristic of a flow control. This function is only meaningful if a flow control is to be implemented.
-
Page 109: Operation Of The Process Controller
A precise description of the individual functions can be found in the chapters entitled «Start-up, operation of the posi- tion controller Type 8692» — «Specifying the basic settings» and in «Configuring the auxiliary functions». Configuration level -> Process operating level Press the left selection key (EXIT) to switch from the Configuration level to the Process operating level.
-
Page 110: Automatic Operating State
Type 8692, 8693 Start-up, operation process controller Type 8693 3.3 AUTOMATIC operating state Bar running from left to right along the upper edge of the display. Normal control mode is implemented and monitored in AUTOMATIC operating state. 3.3.1 Meaning of the keys…
-
Page 111: Operating Structure
Type 8692, 8693 Start-up, operation process controller Type 8693 3.3.3 Operating Structure AUTOMATIC operating state Configuration Switch between the MENU Display displays* Menu option (no operator action) EXIT EXIT TEMP INPUT active** Set process set- point value MANU AUTO MANUAL operating state Fig.
-
Page 112: Manual Operating State
Type 8692, 8693 Start-up, operation process controller Type 8693 3.4 MANUAL operating state Without bar running from left to right along the upper edge of the display. In MANUAL operating state the valve can be opened or closed manually. 3.4.1 Meaning of the keys…
-
Page 113: Auxiliary Functions For The Process Controller
4 AUXILIARY FUNCTIONS FOR THE PROCESS CONTROLLER In this chapter only those auxiliary functions are described which differ from the position controller Type 8692. All other auxil- iary functions and their settings can be found in the chapters entitled «Start-up, operation of the position controller Type 8692″…
-
Page 114: Including Auxiliary Functions In The Main Menu
After pressing the selection key on the left (EXIT), the auxiliary function is deactivated and removed from the main menu. A precise description on the operation of the auxiliary functions can be found in the chapters entitled «Start-up, operation of the position controller Type 8692» — «Specifying the basic settings» and in «Configuring the auxiliary functions».
-
Page 115: Cutoff Sealing Function For The Position Controller Type 8693
Type 8692, 8693 Start-up, operation process controller Type 8693 4.2 CUTOFF Sealing function for the position controller Type 8693 This function causes the valve to be sealed outside the control area. This is where you input the limits for the position set-point value (CMD) as a percentage or for the process set-point value (SP) as a percentage of the scaling range, from which the actuator is fully deaerated or aerated.
-
Page 116: Security Code Protection For The Settings
Type 8692, 8693 Start-up, operation process controller Type 8693 4.3 SECURITY Code protection for the settings Use the SECURITY function to prevent the positioner or individual functions from being accessed unintentionally. Factory setting: Access Code: 0000 If the code protection is activated, the code (set access code or master code) must be input whenever operator action is disabled.
-
Page 117: Sig-Error Configuration Of Signal Level Fault Detection
Type 8692, 8693 Start-up, operation process controller Type 8693 4.4 SIG-ERROR Configuration of signal level fault detection The SIG-ERROR function is used to detect a fault on the input signal. ENTER ENTER Signal fault detection SP/CMD Input SIG.ERROR Process set-point value / nominal position…
-
Page 118: Output (Option) Configuring The Outputs
Type 8692, 8693 Start-up, operation process controller Type 8693 Fault detection Fault detection can be selected at 4 – 20 mA and with a PT100 signal. 4 – 20 mA Fault with input signal ≤ 3.5 mA (± 0.5 % of end value, hysteresis 0.5 % of end value) PT100 Fault with input signal 225 °C (±…
-
Page 119
Type 8692, 8693 Start-up, operation process controller Type 8693 OUT ANALOG — Configuration of the analogue output Only for the versions: • one analogue output • one analogue output and two binary outputs The feedback of the current position (POS), the position set-point value (CMD), the process actual value (PV) or the process set-point value (SP) can be transmitted to the control centre via the analogue output. -
Page 120
Type 8692, 8693 Start-up, operation process controller Type 8693 OUT BIN1 — Configuration of the binary output 1 OUT BIN2 — Configuration of the binary output 2 Only for the versions: • one analogue output and two binary outputs •… -
Page 121
Type 8692, 8693 Start-up, operation process controller Type 8693 Alarm output for excessively large control deviation of the position controller: OUT DEV.X → Press the arrow keys to mark the OUT DEV.X menu option and confirm with the selection key on the right (SELEC). -
Page 122: Cal.user Calibrating The Actual Value Display And The Inputs For The Process Values
Type 8692, 8693 Start-up, operation process controller Type 8693 4.6 CAL.USER Calibrating the actual value display and the inputs for the process values The following points can be manually calibrated with this function: • Position display ( POS) 0 – 100% •…
-
Page 123
Type 8692, 8693 Start-up, operation process controller Type 8693 Procedure: Calibrating the actual value display POS (0 — 100 %): calibr. POS → In the CAL. USER menu press the arrow keys to select the calibr. POS menu option and confirm with the selection key on the right (ENTER). -
Page 124
Type 8692, 8693 Start-up, operation process controller Type 8693 Accept the maximum input signal (20 mA): → Press the arrow keys to select the PV 20 mA menu option and confirm with the selection key on the right (INPUT). →… -
Page 125
Type 8692, 8693 Start-up, operation process controller Type 8693 english… -
Page 126
BUS STATUS DISPLAY………………………………..136 10 CONFIGURATION WITH SIEMENS STEP7 …………………………137 10.1 Example 1 for a Position controller (Type 8692): Transfer of nominal and actual values……..137 10.2 Example 2 for a Position controller (Type 8693): Transfer of several process values……….138 english… -
Page 127: General Information
Type 8692, 8693 PROFIBUS-DP 1 GENERAL INFORMATION The following sections of the general operating instructions do not apply to the positioner with PROFIBUS-DP: • Variants of the positioner • Initial start-up • Electrical connection • Specifying the standard settings Function INPUT…
-
Page 128: Safety Settings If The Bus Fails
Type 8692, 8693 PROFIBUS-DP 3 SAFETY SETTINGS IF THE BUS FAILS The position is approached which corresponds to the set-point value last transferred (default setting). Other setting optioins (see chapter entitled Settings on the positioner). 4 INTERFACES Positioner Inputs for…
-
Page 129: Electrical Connections
For operation of the device always connect the 5-pole, inversely coded M12 round socket and the 4-pole M12 round plug (power supply). The connection module of Type 8692 and 8693 features a setscrew with nut which is used to connect the Technical Earth (see diagram).
-
Page 130: Connection Diagram Type 8693
Type 8692, 8693 PROFIBUS-DP 5.2 Connection Diagram Type 8693 Plug M8 Plug M12 4-pole 4-pole (process actual value) (operating voltage) Technical Earth Socket M12 (TE) 5-pole (inversly-coded) Switch (PROFIBUS-DP) (behind the screw) Fig. 3: Connection Profibus 8693 5.3 Operating Voltage (Round Plug M12, 4-pole)
-
Page 131: Process Actual Value (Round Plug M — Only Type 8693
Type 8692, 8693 PROFIBUS-DP 5.5 Process Actual Value (Round Plug M — only Type 8693 Input type* Configuration Switch** External circuit 4 – 20 mA + 24 V transmitter supply — internally supplied Output from transmitter Transmitter Switch on…
-
Page 132: Settings On The Positioner
The specification of the basic settings on the positioner can be found in the following chapters: • Type 8692: «Starting up and operating the position controller Type 8692» / «Starting up and setting up the position controller Type 8692» •…
-
Page 133: Explanations Of The Menu Options In The Bus.comm Menu
Type 8692, 8693 PROFIBUS-DP 6.1 Explanations of the Menu Options in the BUS.COMM Menu 6.1.1 BUS.COMM Menu for Type 8692 ENTER INPUT BUS.COMM Address Address: ENTER SafePos off SELEC BUS FAIL EXIT SafePos on ENTER BUS PDI Position ENTER Temperature…
-
Page 134: Bus.comm Menu For Type 8693
Type 8692, 8693 PROFIBUS-DP 6.1.2 BUS.COMM Menu for Type 8693 ENTER INPUT BUS.COMM Address Address: ENTER SafePos off SELEC BUS FAIL EXIT SafePos on ENTER BUS PDI Position ENTER Process value * Setpoint * Temperature Operation mode Errors EXIT P.CONTRL active…
-
Page 135: Functional Deviations From The Standard Model
Type 8692, 8693 PROFIBUS-DP Address XXX Input the device address Press the arrow keys (+/-) to set values from 0 – 126; Confirm by pressing the selection key on the right (OK). BUS FAIL Activate to approach the safety position if the bus communication fails SafePos off The position is approached which corresponds to the set-point value last transferred.
-
Page 136: Configuration In The Profibus-Dp Master
The value is retained until it is deleted with PDO:ERR. 14 PDO:CMD / SP 16 PDO:MODE Identifier (HEX): 41, 00, 06 PDI: 0: Position controller (8692) GSD file: PDI:PCONact PCONact 1: Process controller (8693) Identifier (HEX): 41, 00, 0A PDI:PV and PDI:SP can be selected for Type 8693 (process controller) only and are beneficial only when process controller activated.
-
Page 137: Bus Status Display
(From the controller to the positioner) Name Description Identifier PDO:CMD / For position controller Type 8692: GSD file: PDO:CMD/SP Nominal position (input) Set-point value of position controller as ‰. Value range 0 – 1000 Identifier (HEX): 81, 40, 14 If the value is too small or too large, the last valid value is used and is indicated in ERR with HEX 14.
-
Page 138: Configuration With Siemens Step7
Type 8692 / 8693 by Drag & Drop to the bus line. Fig. 8: Screenshot of position controller Fig. 2 → pull the modules PDI:POS and PDO:CMD/SP into the slave Type 8692 / 8693 by Drag & Drop. english…
-
Page 139: Example 2 For A Position Controller (Type 8693): Transfer Of Several Process Values
Transfer of several process values. Procedure as in example 1. → pull the slave Type 8692 / 8693 by Drag & Drop to the bus line. Fig. 9: Screenshot of position controller Fig. 3 → pull the modules into the slave Type 8692 / 8693 by Drag & Drop.
-
Page 140
TECHNICAL DATA ………………………………….140 SAFETY SETTINGS IF THE BUS FAILS …………………………..141 INTERFACES …………………………………….141 ELECTRICAL CONNECTIONS ………………………………142 Connection Diagram Type 8692 …………………………..142 Connection Diagram Type 8693 …………………………..143 Operating Voltage (M12 Round Plug, 4-pole) ……………………..143 Bus Connection (M12 Round Plug, 5-pole) ……………………….143 Process Actual Value (M 8 Round Plug) ……………………….144 Terminating Circuit for DeviceNet Systems ………………………..144… -
Page 141: General Information
Type 8692, 8693 DeviceNet 1 GENERAL INFORMATION The following sections of the general operating instructions do not apply to the DeviceNet variant of the positioner 8692 / 8693: • Variants of the positioner • Initial start-up • Electrical connection •…
-
Page 142: Safety Settings If The Bus Fails
Type 8692, 8693 DeviceNet Total line length according to DeviceNet Specification (Total line length = total of all trunk and drop lines) Maximum total line length Baudrate Thick cable Thin cable 125 kbaud 500 m 100 m for all baudrates…
-
Page 143: Electrical Connections
For operation of the device always connect the 5-pole (bus) and the 4-pole M12 round plug (power supply). The connection module of Type 8692 and 8693 features a setscrew with nut which is used to connect the Technical Earth (see diagram).
-
Page 144: Connection Diagram Type 8693
Type 8692, 8693 DeviceNet 6.2 Connection Diagram Type 8693 Socket M8 Socket M12 4-pole 4-pole (process actual value) (operating voltage) Technical Earth (TE) Switch Buchse M12 (behind the screw) 5-polig (DeviceNet) Fig. 3: Connection of DeviceNet-8693 The power supply to the device is not supplied via the DeviceNet voltage V+ und V-, but via the operating voltage galvanically isolated from the DeviceNet.
-
Page 145: Process Actual Value (M 8 Round Plug)
Type 8692, 8693 DeviceNet 6.5 Process Actual Value (M 8 Round Plug) Input type* Configuration Switch** External circuit 4 – 20 mA + 24 V transmitter supply — internally supplied Output from transmitter Transmitter Switch on Bridge after GND (GND from…
-
Page 146: Network Topology Of A Devicenet System
Type 8692, 8693 DeviceNet 6.7 Network Topology of a DeviceNet System Line with one trunk line and several drop lines. Trunk lines and drop lines consist of identical material (see diagram). Trunk line DeviceNet cable V + * V –*…
-
Page 147: Settings On The Positioner In The Main Menu
The specification of the basic settings on the positioner can be found in the following chapters: • Type 8692: «Starting up and operating the position controller Type 8692» / «Starting up and setting up the position controller Type 8692» •…
-
Page 148: Explanations Of The Menu Options In The Bus.comm Menu
Type 8692, 8693 DeviceNet 7.1 Explanations of the Menu Options in the BUS.COMM Menu ENTER INPUT BUS.COMM Address Address: ENTER BAUDRATE 125 kBd SELEC 250 kBd EXIT 500 kBd ENTER SafePos off BUS FAIL SELEC EXIT EXIT SafePos on Fig. 6: Operating structure — BUS-COMM — DeviceNet…
-
Page 149: Functional Deviations From The Standard Model
Type 8692, 8693 DeviceNet 8 FUNCTIONAL DEVIATIONS FROM THE STANDARD MODEL It is possible to switch between the MANUAL and AUTOMATIC operating states on the process operating level either via the keyboard on the positioner or via the bus. It is no longer possible to switch between MANUAL / AUTOMATIC on the keyboard if an operating mode (under PDO MODE) is transferred to the positioner via the bus.
-
Page 150
Type 8692, 8693 DeviceNet Name Description of the input data attributes Attribute Address Class, Instance, Attribute; Data type, Length Actual position 111, 1, 59; Actual value of position controller as ‰. Value range 0–1000. However, values <0 or >1000 also possible if e.g. Autotune has not run through INT, 2 byte correctly. -
Page 151: Static Output Assemblies
Type 8692, 8693 DeviceNet 9.2 Static Output Assemblies Name Address of data attribute of the assemblies Format of the for read access. Class, Instance, Attribute data attribute INP (factory setting) 4, 21, 3 Byte 0: INP low Byte 1: INP high…
-
Page 152: Bus Status Display
Type 8692, 8693 DeviceNet 10 BUS STATUS DISPLAY The bus status is indicated on the display on the device. Display Device status Explanation/Troubleshooting BUS offline offline Device is not connected to the bus, the network access procedure (duplicate MAC-ID test, duration approx. 2 s) has still not ended or…
-
Page 153: Configuration Example 1
Type 8692, 8693 DeviceNet 11 CONFIGURATION EXAMPLE 1 The example describes the principle procedure when configuring the device using the software RSNetWorx for DeviceNet (Rev. 4.12.00). 11.1 Installation of the EDS File The EDS file supplied on the CD is installed with the aid of the EDS Installation Wizard Tool associated with RSNetWorx.
-
Page 154: Offline Parameterisation Of The Device
Type 8692, 8693 DeviceNet 11.3 Offline Parameterisation of the Device When a device has been inserted into the DeviceNet configuration of RSNetWorx, the device can be parameterised offline. Fig. 8 indicates how, for example, an input assembly which deviates from the factory setting (input process data can be transferred via I/O connection) can be selected.
-
Page 155: Offline Parameterisation Of The Device
Type 8692, 8693 DeviceNet 10.4 Offline Parameterisation of the Device Devices can also be parameterised online. In doing so, you can also select whether only individual parameters (single) or all parameters (all) of a group are read from the device (upload) or are loaded into the device (download).
-
Page 156: Configuration Example 2
Type 8692, 8693 DeviceNet 12 CONFIGURATION EXAMPLE 2 This example describes the principle procedure for setting up the process image of a DeviceNet master/scanner using the soft- ware RSNetWorx for DeviceNet (Rev. 4.12.00). Setting up the scan list and setting the I/O parameters First of all the scan list of the DeviceNet master/scanner is set up.
-
Page 157: Setting Up The Process Image (Mapping)
Type 8692, 8693 DeviceNet 12.1 Setting up the Process Image (Mapping) The AUTOMAP function is used to assign the input data of the devices specified in the scan list to the process image of the DeviceNet master/scanner. Our example of the assignment is indicated in Fig. 11.
-
Page 158
Type 8692, 8693 Servicing and Troubleshoot- ing the Position Controller Servicing and Troubleshooting the Position Controller Type 8692 ABLE OF ONTENTS MAINTENANCE ……………………………………158 ERROR MESSAGES AND MALFUNCTIONS …………………………158 Error Messages on the Display …………………………..158 2.1.1 General Error Messages …………………………158 2.1.2 Error Messages while the X.TUNE Function is Running ………………158 Other Malfunctions ………………………………..159… -
Page 159
Servicing and Troubleshoot- ing the Position Controller 1 MAINTENANCE The positioner Type 8692 is maintenance-free when operated according to the instructions indicated in this manual. 2 ERROR MESSAGES AND MALFUNCTIONS 2.1 Error Messages on the Display 2.1.1 General Error Messages… -
Page 160
Type 8692, 8693 Servicing and Troubleshoot- ing the Position Controller 2.2 Other Malfunctions Problem Possible causes Remedial action POS = 0 (when CMD > 0 %) or Sealing function (CUTOFF) has been Deactivate sealing function POS = 100 %, (when CMD < 100 %) -
Page 161
Type 8692, 8693 Servicing and Troubleshoot- ing the Position Controller english… -
Page 162
Type 8692, 8693 Servicing and Troubleshoot- ing the Process Controller Servicing and Troubleshooting the Process Controller Type 8693 ABLE OF ONTENTS MAINTENANCE ……………………………………162 ERROR MESSAGES AND MALFUNCTIONS …………………………162 Error Messages on the LC Display ………………………….162 2.1.1 General Error Messages …………………………162 2.1.2 Error Messages while the X.TUNE Function is Running ………………163… -
Page 163: Maintenance
Type 8692, 8693 Servicing and Troubleshoot- ing the Process Controller 1 MAINTENANCE The positioner type 8693 is maintenance-free when operated according to the instructions indicated in this manual. 2 ERROR MESSAGES AND MALFUNCTIONS 2.1 Error Messages on the LC Display 2.1.1 General Error Messages…
-
Page 164: Error Messages While The X.tune Function Is Running
Type 8692, 8693 Servicing and Troubleshoot- ing the Process Controller 2.1.2 Error Messages while the X.TUNE Function is Running Display Causes of error Remedial action X.TUNE locked The X.TUNE function is blocked Input access code X.TUNE No compressed air connected…
-
Page 165: Error Messages On Field Bus Devices
Type 8692, 8693 Servicing and Troubleshoot- ing the Process Controller 2.1.4 Error Messages on Field Bus Devices Display Device status Explanation/Troubleshooting BUS offline offline Device is not connected to the bus, the network access procedure (duplicate MAC-ID test, duration approx. 2 s) has still not ended or…
-
Page 166
Type 8692, 8693 Packaging, Storage and Disposal Packaging, Storage and Disposal ABLE OF ONTENTS PACKAGING AND TRANSPORT ……………………………..166 STORAGE ……………………………………..166 DISPOSAL ……………………………………..166 english… -
Page 167
Type 8692, 8693 Packaging, Storage and Disposal 1 PACKAGING AND TRANSPORT NOTICE! Transport damages! Inadequately protected equipment may be damaged during transport. • Protect the unit against wet and dirt during transport and pack safely in shock-resistant packaging. • Avoid the effects of heat and cold which could result in temperatures above or below the permitted storage temperature. -
Page 168
Type 8692, 8693 General Rules — Appendix General Rules (Appendix) ABLE OF ONTENTS SELECTION CRITERIA FOR CONTINUOUS VALVES ……………………..168 PROPERTIES OF PID CONTROLLERS …………………………..170 P Portion ……………………………………170 I Portion ……………………………………171 D Portion ……………………………………172 Superposition of P, I and D Portions …………………………173 Implemented PID Controller …………………………….174… -
Page 169: Selection Criteria For Continuous Valves
Type 8692, 8693 General Rules — Appendix 1 SELECTION CRITERIA FOR CONTINUOUS VALVES The following criteria are crucial for optimum control behaviour and to ensure that the required maximum flow is reached: • the correct selection of the flow coefficient which is defined primarily by the nominal width of the valve;…
-
Page 170
Type 8692, 8693 General Rules — Appendix The k value of the continuous valve should have at least the value which is calculated according to equation (1) or (2) which is appropriate to the application, however it should never be far above the calculated value. -
Page 171: Properties Of Pid Controllers
Type 8692, 8693 General Rules — Appendix 2 PROPERTIES OF PID CONTROLLERS A PID controller has a proportional, an integral and a differential portion (P, I and D portion). 2.1 P Portion Function: ⋅ Kp is the proportional coefficient (amplification factor). It is the ratio of the adjusting range ΔY to the proportional range ΔXd.
-
Page 172: I Portion
Type 8692, 8693 General Rules — Appendix 2.2 I Portion Function: ∫ Ti is the integral action time or actuating time. It is the time which passes until the actuating variable has run through the whole adjustment range. Characteristic and step response of the I portion of a PID controller…
-
Page 173: D Portion
Type 8692, 8693 General Rules — Appendix 2.3 D Portion Function: ⋅ Kd is the derivative action coeffficient. The larger Kd is, the greater the D-effect is. Characteristic and step response of the I portion of a PID controller Step response Ramp response Fig.
-
Page 174: Superposition Of P, I And D Portions
Type 8692, 8693 General Rules — Appendix 2.4 Superposition of P, I and D Portions Function: ∫ ⋅ Where Kp · Ti = Tn and Kd/Kp = Tv the function of the PID controller is calculated according to the following equation: ∫…
-
Page 175: Implemented Pid Controller
Type 8692, 8693 General Rules — Appendix 2.5 Implemented PID Controller 2.5.1 D Portion with Delay In the process controller of the positioner the D portion is implemented with a delay T. Function: ⋅ ⋅ Superposition of P, I and DT Portions Fig.
-
Page 176: Adjustment Rules For Pid Controllers
Type 8692, 8693 General Rules — Appendix 3 ADJUSTMENT RULES FOR PID CONTROLLERS The regulatory literature includes a series of adjustment rules which can be used in experimental ways to determine a favour- able setting for the controller parameters. To avoid incorrect settings, always observe the conditions under which the particular adjustment rules have been drawn up.
-
Page 177: Adjustment Rules According To Chien, Hrones And Reswick (Actuating Variable Jump Method)
Type 8692, 8693 General Rules — Appendix 3.2 Adjustment Rules according to Chien, Hrones and Reswick (Actuating Variable Jump Method) With this method the controller parameters are adjusted on the basis of the transient behaviour of the controlled system. An actuating variable jump of 100 % is output.
-
Page 178
Type 8692, 8693 General Rules — Appendix Adjustment of the parameters according to Chien, Hrones and Reswick Adjustment of the parameters Controller type for aperiodic control process for control process (0 % overshoot) with 20 % overshoot Reference Malfunction Reference Malfunction ⋅… -
Page 179
Type 8692, 8693 General Rules — Appendix english… -
Page 180
Type 8692, 8693 Operating structure — Appendix Operating structure of the positioner (Appendix) ABLE OF ONTENTS OPERATING STRUCTURE OF THE POSITIONER ……………………….180 english… -
Page 181
Type 8692, 8693 Operating structure — Appendix 1 OPERATING STRUCTURE OF THE POSITIONER ACTUATOR SINGLE DOUBLE INPUT 4-20 mA 0-20 mA 0-10 V 0- 5 V BUS.COMM * Address Address: BAUDRATE * 125 kBd 250 kBd 500 kBd BUS FAIL… -
Page 182
100 % CUT type* Type PCO Type XCO DIR.CMD Rise Fall DIR.ACT Rise Fall SPLTRNG* 100 % 100 % X.LIMIT 100 % 100 % Fig. 2: Operating structure — 2 *1 only process controller 8693 *2 only position controller 8692 english… -
Page 183
Type 8692, 8693 Operating structure — Appendix X.TIME Open Open Close Close DBND X.CONTROL DBND KXopn 0001 KXopn KXcls KXcls 0001 P.CONTROL* PARAMETER DBND DBND 1.00 1.00 999.9 999.9 0.0% 0.0% FILTER FILTER SETUP PV INPUT 4-20 mA Frequency PT 100… -
Page 184
Type 8692, 8693 Operating structure — Appendix SP SCALE* SPmin 0.0 bar SPmin SPmax 100.0 bar SPmax 100.0 P.CO INIT bumpless standard SECURITY Access Code CODE CODE MAIN MANU/AUTO ADDFUNCT X.TUNE P.Q‘LIN * Safepos Safepos 0% Safepos SIG.ERROR SP/CMD Input… -
Page 185
Type 8692, 8693 Operating structure — Appendix BINARY-IN SAFEPOS MANU/AUTO BIN.IN TYPE normally opened normally closed OUTPUT OUT ANALOG Out POS Out CMD Out PV Out SP OUT type 4 — 20 mA 0 — 20 mA 0 — 10 V… -
Page 186
Fig. 6: Operating structure — 6 *1 only process controller 8693 *2 only position controller 8692 *3 The signal type is displayed which is selected in the INPUT menu *4 only 8693, only for external set-point value default (P.CONTROL / SETUP / SP-INPUT / external) *5 only 8693, only for signal type 4 –… -
Page 187
Type 8692, 8693 Operating structure — Appendix SER. IO BAUD-RATE 1200 2400 4800 9600 19200 38400 I / O — MODE RS232-HART NONE par.,1Stop EVEN par.,1Stop ODD par.,1Stop NONE par.,2Stop EVEN par.,2Stop ODD par.,2Stop Burst EXTRAS DISPLAY normal invers SERVICE Fig. -
Page 188
Type 8692, 8693 Position Controller Table Type 8692 — Appendix Position Controller Table Type 8692 (Appendix) ABLE OF ONTENTS TABLE FOR YOUR SETTINGS ON THE POSITION CONTROLLER ………………..188 Settings of the Freely Programmable Characteristic……………………188 english… -
Page 189
Type 8692, 8693 Position Controller Table Type 8692 — Appendix 1 TABLE FOR YOUR SETTINGS ON THE POSITION CONTROLLER 1.1 Settings of the Freely Programmable Characteristic Node Valve stroke [%] (position set-point Date: Date: Date: Date: value as %) english… -
Page 190
Type 8692, 8693 Process Controller Table Type 8693 — Appendix Process Controller Table Type 8693 (Appendix) ABLE OF ONTENTS TABLE FOR YOUR SETTINGS ON THE PROCESS CONTROLLER ………………..190 Settings of the Freely Programmable Characteristic……………………190 Set Parameters of the Process Controller ……………………….190… -
Page 191
Type 8692, 8693 Process Controller Table Type 8693 — Appendix 1 TABLE FOR YOUR SETTINGS ON THE PROCESS CONTROLLER 1.1 Settings of the Freely Programmable Characteristic Node Valve stroke [%] (position set-point Date: Date: Date: Date: value as %) 1.2 Set Parameters of the Process Controller… -
Page 192
Type 8692, 8693 Master code (Appendix) Master code (Appendix) ABLE OF ONTENTS MASTER CODE ……………………………………192 english… -
Page 193
Type 8692, 8693 Master code (Appendix) 1 MASTER CODE Mastercode 3108 english… -
Page 195
www.burkert.com…
This manual is also suitable for:
8693
-
Parker
MX80L series
Manual No. 100-5326- 01Rev. 8 MX80L Precision Grade MX80L Standard Grade Product Manual Effective: July 11, 2011 Supersedes: March 1, 201 Electromechanical Positioning Systems Daedal www.comoso.com …
MX80L series Valve Positioners, 43
-
Schubert & Salzer
8047
Betriebsanleitung Operating Instructions Manuel d’utilisation Typ 8047 i/p positioner p/p positioner Version: 10/2019 M8047-def.doc Art.-Nr: 110 8047 Bunsenstrasse Tel: (0841) 9654-0 www.schubert-salzer.com D-85053 Ingolstadt Fax: (0841) 9654-590 …
8047 Valve Positioners, 40
-
halstrup-walcher
PS*3**IO series
Document 7100.005374 10/2017 Instruction Manual PSx3xxIO halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Tel.: +49 (0) 76 61/39 63-0 Fax: +49 (0) 76 61/39 63-99 Email: [email protected] Website: www.halstrup-walcher.de …
PS*3**IO series Valve Positioners, 37
-
Ytc
YT-1000R
Electro-Pneumatic Positioner YT-1000R Trouble Shooting Manual Young Tech Co. #662-8 PumgMu Dong, Kimpo City, (415-809) Korea (031) 986-4935 www.ytc.co.kr Troubleshooting ▶ Positioner does not respond to the input signal. (1) Check supply pressure level. The lever must be at least 1.4 kgf/cm2. …
YT-1000R Valve Positioners, 2
-
halstrup-walcher
PS*3**PL series
Instruction Manual PSx3xxPL 1 Instruction Manual PSx3xxPL halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Tel.: +49 (0) 76 61/39 63-0 Fax: +49 (0) 76 61/39 63-99 E-Mail: [email protected] Internet: www.halstrup-walcher.com Document 7100.005424 07/2017 …
PS*3**PL series Valve Positioners, 33
-
Siemens
SIPART Series
SIPART Elektropneumatische Stellungsregler SIPART PS2 Non Contacting Sensor (NCS) Kompaktbetriebsanleitung Rechtliche Hinweise Warnhinweiskonzept Dieses Handbuch enthält Hinweise, die Sie zu Ihrer persönlichen Sicherheit sowie zur Vermeidung von Sachschäden beachten müssen. Die Hinweise zu Ihrer persönlichen Sic …
SIPART Series Kitchen Appliances, 34
Recommended Documentation:
Цифровой электропневматический позиционер Burkert 8692 разработан специально для регулирующих пневмоклапанов Burkert 23XX/2103. Позиционер изготовлен из нержавеющей стали и полисульфона, что позволяет использовать его в CIP-процессах.
Позиционер оснащен ЖК-дисплеем с подсветкой и 4 клавишами управления.
Технические данные
производитель
Burkert
Если вы хотите купить цифровой электропневматический позиционер burkert 8692 , вы можете:
Ещё из раздела Позиционеры для регулирующих клапанов Burkert
Электропневматический позиционер/ПИД-регулятор Burkert 1067 применяется совместно с регулирующими пневмоклапанами Burkert . Позиционер 1067 может устанавливаться как на регулирующие клапаны Burkert серии 2702/2712, так и на линейные пневмоприводы и …
Электропневматический позиционер/ПИД-регулятор Burkert 8630 Top Control применяется для регулирующих пневмоклапанов. Позиционер 8630 Top Control устанавливается на регулирующие клапаны Burkert серии 2702/2712. Технические данные Инструкция по …
Электропневматический позиционер/ПИД-регулятор Burkert 8635 SideControl применяется совместно с регулирующими пневмоклапанами Burkert . Позиционер 8635 может устанавливаться как на регулирующие клапаны Burkert серии 2702/2712, так и на линейные …
Цифровой электропневматический позиционер Burkert 8696 разработан специально для регулирующих пневмоклапанов Burkert 23XX/2103 с приводом Ø 50 мм. Позиционер 8696 изготовлен из нержавеющей стали и полисульфона, что позволяет использовать его в …
Электропневматический позиционер (регулятор положения) Burkert 8792 используется для регулирующих пневмоклапанов как простого, так и двойного действия. Позиционер 8792 является усовершенствованной моделью 1067. Позиционер 8792 выгодно отличается от …
Электропневматический позиционер (ПИД-регулятор) Burkert 8793 используется для регулирующих пневмоклапанов как простого, так и двойного действия. Позиционер 8793 является усовершенствованной моделью 1067. Отличие от позиционера 8792 заключается в …
Описание типаКомпактный датчик фактического положения типа 8692 разработан для интегрированной установки на пневматические приводы серий регулирующих прямоточных клапанов типа 23XX/2103 и специально для технологических условий гигиенических процессов. Подвод воздуха системы управления в привод происходит интегрированно, без использования внешних гибких трубопроводов. Легкое обслуживание и широкий выбор дополнительных программных функций осуществляются на большом графическом дисплее с фоновой подсветкой и через сенсорную клавиатуру или интерфейс ПК. Датчик фактического положения определяет положение клапана, не подвергаясь износу, через бесконтактный аналоговый сенсор. Благодаря наличию диагностических функций можно контролировать условия эксплуатации регулирующего клапана. Диагностические сообщения о клапане через сигналы о состоянии направляются согласно NE107 (NAMUR) и сохраняются в форме хронологических записей. Корпус из материалов, устойчивых к воздействию химии, легко подвергается чистке и предлагает зарекомендовавшую себя на практике защиту оболочки для эксплуатации в гигиеническом технологическом оборудовании продовольственной и фармацевтической отраслей. В комбинации с приводами Bürkert серии ELEMENT пневматическая система управления позволяет осуществлять вентиляцию полости установки пружины, препятствуя при этом загрязнению пневматических камер исполнительного механизма со стороны окружающей среды. |
||
Type 8692 data sheet | digital electropneumatic positioner | описание | |
Type KK01 data sheet | adapterkits for hygienic process valves | описание | |
burkert | руководство |
Почему вы выбрали именно этот товар?
Для каких целей планируете использовать?
Устраивает ли вас соотношение цены и качества?
Не терпим нечестные отзывы, а также:
Мат, ругательства, оскорбления и угрозы
Контактную информацию, рекламу и прочее, не относящиеся к теме
Обсуждение цены товара и ее изменение
Отзывы по обслуживанию и сервису следует оставлять через раздел Гарантийное обслуживание, там они будут рассмотрены в обязательном порядке