NA 10.139 B

06 — 2011

Module électronique de

régulation et de signalisation

à microprocesseurs pour

refroidisseurs de liquide

et pompe à chaleur

Microchip and LCD display

electronic regulation and

signaling electronic module

for liquid coolers

and heat pumps

Elektronisches Regel- und

Anzeigemodul mit

Mikroprozessor und LCD-

Anzeige für

Flüssigkeitskühler

und Wärmepumpe

Módulo electrónico de

regulación y señalización a

microprocesador y visualizador

LCD para enfriadores de líquido

y bomba de calor

loading

Summary of Contents for CIAT XtraConnect 2

Поиск торговой марки

Расширенный поиск

Вам требуется помощь по использованию изделия?

Просмотрите мнения об изделиях CIAT

Где моя инструкция?

Помогите нам найти наиболее востребованные инструкции
Добавить инструкцию
Регистрация
Вход

Все инструкции по категориям

Вы можете скачать с сайта Diplodocs инструкцию CIAT в формате PDF.



Введите модель изделия CIAT…

Новые инструкции для CIAT

CIAT: 7 документов — Ваша инструкция доступна прямо сейчас!

Популярные инструкции:

7 часто скачиваемых инструкций

MICRO-CONNECT — MICROCIAT MRS 5-1 B — ILZHE 22 30 — ILZH 15 22 30 — AQUACIAT — AQUACIAT ILZHE 130 — AQUACIAT ILZHE 15

Контактный телефон: (495) 664-23-70

E-mail: , пожалуйста, укажите свой контактный телефон

© 2011 — 2023 splitoff
Цены на сайте не являются публичной офертой и указаны без НДС.
Публикация данных статей, фото, видео материалов на других сайтах, форумах, чатах, блогах, без письменного разрешения авторов сайта запрещена.
Регистрируясь на сайте или ставляя отзыв (комментарий), вы соглашаетесь с политикой конфиденциальности.

Manual, Installation, Operation, Commissioning, Maintenance for CIAT XtraConnect 2 Control Unit (62 pages)

Specifications:

1823/1823397-xtraconnect_2.pdf file (09 Mar 2023)

Accompanying Data:

CIAT XtraConnect 2 Control Unit PDF Installation, Operation, Commissioning, Maintenance (Updated: Thursday 9th of March 2023 08:54:19 AM)

Rating: 4.4 (rated by 60 users)

Compatible devices: AeroCONNECT 1B, V3000 KNX, Qseven Q7-974, Magister 2 Series, CIATControl OPC Server, ConSig 8040 Series, by-me 01483, M-Ventil Pulse.

Recommended Documentation:

Text Version of Manual, Installation, Operation, Commissioning, Maintenance

(Ocr-Read Summary of Contents of some pages of the CIAT XtraConnect 2 Document (Main Content), UPD: 09 March 2023)

  • 10, EN — 9 2.6 Connection via RS485 serial port for BMS or control console and Multiconnect with 500 kW module For connection to a CMS, refer to document 399…

  • 22, EN — 21 5.5 Unit parameters menu To enter the UNIT PARAMETERS menu, press + or – to position the cursor on 4 then press OK. The display shows the list of configuration parameters. Use the + and – buttons to scroll through the tables at a rate of two rows at a time. To modify a parameter the configuration mu…

  • 24, EN — 23 P273.2 Supply voltage (module 2). P274.1 Machine current input. P274.2 Current input (module 1). P274.3 Current input (module 2). P275.1 Machine power input. P275.2 Power input (module 1). P275.3 Power input (module 2). P276.1 Electricity consumption. P276.2 Electricity consumption …

  • 47, CIAT XtraConnect 2 EN — 46 21.510.50-0.5 Stage 2 intake Stage 3 intake Stage 3 deadband Stage 2 on Stage 2 off Stage 3 on Stage 3 off Stage 1 on Stage 1 off Calculated error — setpoint Stage 1 intake Stage 2 deadband Stage 1 deadband Stage 1 exhaust Stage 3 exhaust Stage 2 exhaust Stage 2 intake Stage 3 …

  • 37, EN — 36 ● If a fault occurs — Compressors turned off. — Fans turned off. — Contact closes (board output 3) and turns on the evaporator heater (option). — Machine fault relay on optional board in On position. — General fault LED on console lit steadily. — Display: ● To acknowledge the fault — …

  • 9, CIAT XtraConnect 2 EN — 8 J1 RC1 J6J5 J2 J4 J3 0 1 2 3 4 5 6 7 8 2 4 6 8 10 12 14 16 13579111315 54321321 54321 432 1432 1 TERMINAL BLOCK J5 (on/off inputs) 1: 230 V phase input common to the terminal outputs (24 V for inverter compressor). 2: 230 V neutral input, common for redistribution on the terminal bloc…

  • CIAT XtraConnect 2 User Manual

  • CIAT XtraConnect 2 User Guide

  • CIAT XtraConnect 2 PDF Manual

  • CIAT XtraConnect 2 Owner’s Manuals

Recommended: Climate RC5000, 82140, imageCLASS MF8170c

  • Asco 551 Series

    32530552-001530552-001Installation and Maintenance Instructions5/2 GBSeries 551-553 solenoid valves, metal-to-metal, stainless steel body, 1/4“, 1/2″ threadDESCRIPTION OF THE APPROVALVersions concerned by the approval:Stainless steel body (series 551, 553), monostable (spring return) or bistable, 5/2 version is …

    551 Series 18

  • Texas Instruments ADS1x7xEVM-PDK

    1SBAU197A–February 2012–Revised January 2016Submit Documentation FeedbackCopyright © 2012–2016, Texas Instruments IncorporatedADS1x7xEVM-PDKUser’s GuideSBAU197A–February 2012–Revised January 2016ADS1x7xEVM-PDKADS1x7xEVM-PDKThis user’s guide describes the characteristics, operation, and use …

    ADS1x7xEVM-PDK 27

  • Moeller LE 4-505-BS1

    Hardware and EngineeringLE 4-505-BS1AS-I Network Module02/98 AWB 27-1314 GB1st published 1998, edition 02/98© Moeller GmbH, BonnAuthor: Peter RoerschEditor: Klaus Krüger, Thomas KrachtTranslators: Baker & Harrison, Terence Osborn1314U1g.fm Seite 1 Freitag, 2. Juli 1999 9:29 09 …

    LE 4-505-BS1 94

  • Bosch GCC30-4

    IMPORTANT: Read Before UsingIMPORTANT : Lire avant usageIMPORTANTE: Leer antes de usarFor English Version See page 2Version française Voir page 19Versión en español Ver la página 37Call Toll Free for Consumer Information and Service LocationsPour obtenir des informations et les adresses de nos centres de service a …

    GCC30-4 56

Additional Information:
Popular Right Now:

Operating Impressions, Questions and Answers:

The Xtraconnect 2 control module consists of:

● Machines with 2 and 3 circuits on module 1:

— 1 common control and display console with C

on unit.

— 1 motherboard with hardware common with the tropicalised

C

2 board with the Xtraconnect 2 software.

ONNECT

— 1 tropicalised expansion board (ADD 3) with its rotary switch

set to 1.

● Machines with 3 circuits on module 2:

— 1 tropicalised expansion board (ADD 3) with its rotary switch

set to 2.

— 1 tropicalised expansion board (ADD 1) with its rotary switch

set to 3.

● Analogue inputs:

— Acquire signals measured by temperature sensors.

— Acquire signals measured by pressure by sensors.

— Acquire

faults from the

components.

● Actions:

— Compares the setpoint and the water temperature to calculate

which stages are to be turned on or off.

● Outputs:

— Control stage control.

— Pump control.

— General fault.

 Consoles

● Local console:

 Front panel

Setpoint 1/ Setpoint 2

selection

Cooling/Heating

mode selection

 Mounting dimensions (in mm) of remote control console

2 fitted

ONNECT

surrounding electromechanical

General fault

Red circuit fault

LED

35

Ø 5

Ø 10

— The controls on the local console are enabled regardless of

the value of P103.

— All faults can be reset from the FAULT MEMORY menu.

● Remote control console:

— Reading of values.

— The controls are enabled if P103 is set to ‘remote’.

In this case, the following parameters are modifiable:

• On/Off.

• Cooling/Heating.

• All the adjustment parameters accessible via the authorised

access level.

• All locked parameters accessible via the authorised access

level (except the first nine).

• Faults cannot be reset.

• Test mode inaccessible.

● BMS, control console, etc:

— All are available in read mode.

— All are available in write mode, except for P1 to P99 and

(P100; P103; P104; P105).

— Parameters P1 to P99 are editable.

— If P99 is unlocked on the machine console.

— Faults cannot be reset remotely.

NOTE: All the registers are viewable regardless of the value of

P103 (see communication protocol).

— To be able to write parameters, P103 must be set to ‘remote’.

— To be able to switch between heating and cooling, P199 must

be set to ‘cooling/heating’ via the console.

— To be able to switch between setpoints 1 and 2, P120 must be

set to ‘2’ via the console.

LCD

Acknowledge

(possible in fault

LEDs

memory menu only)

235

153