10275_CPI1575_PH3 8/14/07 8:37 AM Page 1 Main Icons Our Thanks to You Introduction Intro Operation Customer Warranty Thank you for purchasing Assistance the Cobra CPI 1575 inverter. Properly used, this Cobra product will give you many years of reliable service. Operating Instructions Main Icons How Your Cobra Power Inverter Works Installation Notes The Cobra power inverter is an electronic product that has been Secondary designed and built to take low voltage DC (Direct Icons Current) power from your automobile or other low voltage power supplies and convert it to standard 115 volt AC (Alternating Current) power like the current you have in your home. This conversion process thereby allows you to use many of your household appliances Warning and electronic Caution Notice products in automobiles, RVs, boats, tractors, trucks and virtually anywhere else. The Cobra line of quality products includes: Customer Assistance Intro CB Radios microTALK® Radios Radar/Laser Detectors Safety Alert® Traffic Warning Systems Secondary Icons Mobile GPS Navigation Systems HighGear® Accessories CobraMarine® VHF Radios CobraMarine® Chartplotters Power Inverters Accessories For more information or to order any of our products, please visit our website: www.cobra.com ® Nothing Comes Close to a Cobra Nothing Comes Close To A Cobra™ Customer Warranty Customer Assistance Assistance Should you encounter any problems with this product, or not understand its many features, please refer to this owner’s manual. If you require further assistance after reading this manual,Notes Cobra Electronics offers the Installation following customer assistance services: For Assistance in the U.S.A. Automated Help Desk English only. 24 hours a day, 7 days a week 773-889-3087 (phone). Customer Assistance Operators English and Spanish. Notice Caution Warning 8:00 a.m. to 6:00 p.m. CT, Monday through Friday (except holidays) 773-889-3087 (phone). Questions English and Spanish. Faxes can be received at 773-622-2269 (fax). Technical Assistance English only. www.cobra.com (on-line: Frequently Asked Questions). English and Spanish. [email protected] (e-mail). For Assistance Outside the U.S.A. Contact Your Local Dealer 1500 WATT POWER INVERTER CPI 1575 Operation Printed in China Part No. 480-400-P Version A A1 © 2008 Cobra Electronics Corporation 6500 West Cortland Street Chicago, Illinois 60707 USA www.cobra.com 10275_CPI1575_PH3 8/14/07 8:37 AM Page 4 Main Icons Main Icons Product Features Introduction Intro Operation Customer Introduction USB Outlet Notice On/Off Caution Power Warning Switch Intro Remote On/Off Switch Jack Secondary Icons Installation Main IconsIcons Secondary Notice Intro Operation Remote On/Off Power Main Icons Output End Installation Notes Installation Installation Requirements . . . . . . . . . . . . . . 6 Caution Warning Notice Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Notes Connecting Cables ...................8 Power Consumption . . . . . . . . . . . . . . . . . 12 Ground Wiring . . . . . . . . . . . . . . . . . . . . . 13 Intro Operation Customer Assistance Warranty Installation Notes Secondary Icons Operation Caution Warning Warning Notes Warranty Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Secondary Icons Customer Assistance Warranty Operation Customer Assistance Notice Intro Caution Notice Operation Turning CautionYour Inverter Warning On or Off . . . . . . . . 14 Remote On/Off Warranty Switch . . . . . . . . . . . . . . . 15 Customer Assistance Indicators . . . . . . . . . . . . . . . . . 16 Operating Operating Limits . . . . . . . . . . . . . . . . . . . . 19 Troubleshooting Guide . . . . . . . . . . . . . . . 20 Specifications . . . . . . . . . . . . . . . . . . . . . . 21 Installation Positive Battery Main Icons Cable Terminal (Red) Cooling Fans Intro Warranty Assistance USB Chassis Ground Terminal Customer Assistance Introduction Our Thanks to You . . . . . . . . . . . . . . . . . . A1 Customer Assistance . . .Warranty . . . . . . . . . . . . . A1 Operation Customer Intro Assistance Product Installation Features . . . . . . . . . . Notes . . . . . . . . . A2 Important Safety Information . ..........1 Secondary Icons Evaluation Before Installation . . . . . . .4 Operation Quick Customer Warranty Notice Negative Battery Cable Terminal (Black) Notes Notes Main Icons Voltage Input & Power Output Indicators AC Outlets Operation Intro Features Assistance • Three AC Receptacles • Reverse Polarity Protection • Voltage & Power Meter • Remote On/Off Capable • Low Battery Alarm • Low Battery Shutdown • Automatic Thermal Installation Notes Protection/Shutdown Secondary Icons Contents Main Icons Warranty Main Icons Installation Customer Assistance Maintenance . . Warning . . . . . . . . . . . . . . . . . . . . . .23 Caution Product Service . . . . . . . . . . . . . . . . . . . . 23 Warranty Accessories and Order Form . . . . . . . . . . 24 Notes Secondary Icons Installation Notes Input End Secondary Icons Notice Caution A2 Warning Nothing Comes Close to a Cobra™ A3 Notice Caution Warning 25 on o 10275_CPI1575_PH3 Intro Operation Customer Assistance Important Safety Information Warranty • Before installing and using your Cobra power inverter, please read these general precautions and warnings. Customer Assistance Operation Warranty Caution and Warning Statements Installation Notes To make the most of this inverter, it must be installed Secondary Icons and used properly. Please read the installation and Customer Warranty Assistance operating instructions carefully before installing and Notes using it. Special attention must be paid to the CAUTION and WARNING statements in the manual. Caution Warning Notice Notes CAUTION Statements specify conditions which could cause damage to the unit or other equipment. Installation Caution Main Icons Warning WARNING Statements identify conditions that could result in personal injury or loss of life. Notice Caution Intro Secondary Icons Customer Assistance on e Page 1 Important Safety Information Introduction ons on 8:37 AM Main Icons on e 8/14/07 Warning General Precautions 1. Operation Never install the inverter in a boat’s engine compartment Customer Warranty where gasAssistance and battery fumes are present. 2. Do not operate the inverter if it has been dropped or damaged in any way. 3. Installation Do not open the inverter; it contains no userNotes serviceable parts. Attempting to service unit could cause electrical shock. NOTE Internal components remain Warranty charged after all power is disconnected. Notice Caution the inverter Warning 4. Do not expose to rain, snow, bilge water or spray. 5. Do not obstruct the ventilation openings. Notes 6. Do not install the inverter in zero-clearance compartment. CAUTION This inverter should be used in negative ground applications only. Caution Warning Nothing Comes Close to a Cobra™ 1 o 10275_CPI1575_PH3 Operation Installation Notes Introduction ons Intro Notice 8/14/07 8:37 AM Page 2 Warranty Customer Assistance Main Icons Caution Main Icons Important Safety Information Operation Customer Warranty Assistance WARNING Power inverters contain components that tend to produce arcs or sparks. To prevent fire Warning or explosion, do not install the inverter in areas or compartments containing batteries or Installation flammable materials or in locationsNotes that require ignition-protected equipment. Secondary Icons WARNING To reduce the risk of fire, do not cover or obstruct the ventilation openings. Do not install inverter in zero-clearance compartment. Caution Notice Caution: Rechargeable Appliances Warning Important Safety Information Introduction Intro Operation Customer Warranty Caution Warning Assistance Cobra 1500 Watt Output Waveform Some very sensitive electronic equipment may not operate satisfactory on “square wave” or “modified sine wave.” The output waveform is referred to as “square wave” or Installation Notes “modified sine wave.” It is a stepped waveform designed to have characteristics similar to the sine wave shape of Secondary Icons utility power. A waveform of this nature is suitable for most AC loads (including linear and switching power suppliers used in electronic equipment, transformers and motors). Notice Certain chargers for small nickel cadmium batteries can be damaged if connected to the Cobra 1500 watt inverter. Two particular types of equipment are prone to this problem: 1. Small battery-operated appliances Plug In Directly such as flashlights, razors, and night lights that can be plugged directly into an AC receptacle to recharge. 2. Certain battery chargers for Dangerous Voltages battery packs used in hand power tools. These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals. This problem does not occur with the vast majority of battery operated equipment. Most use a separate charger or transformer that is plugged into the AC receptacle and produces a low voltage output. If the label on the AC adapter or charger states that it produces a low voltage AC or DC output (less than 30 volts), the inverter will have no problem powering the adapter safely. 2 Nothing Comes Close to a Cobra™ 3 10275_CPI1575_PH3 8/14/07 8:38 AM Page 4 Main Icons Main Icons Quick Evaluation Before Installation Introduction Intro Operation Customer Assistance Warranty Quick Evaluation Before Installation • This section provides you with basic information about the inverter and how to check its performance before installation. Be sure to have on hand: Installation Notes £ A 12 volt DC power source (such as a vehicle battery). Secondary Icons The power source must provide Power Source between 11 and 15 volts DC and be able to supply enough current to run the test load. As a rough guide, divide the wattage ofWarning the test load by Caution Notice 10 to get the current (in amperes) the power source must deliver. £ Cables to connect the power source to the inverter (not included). The cables must be as short and thick as possible in order to reduce the voltage drop between the power source and the inverter when it is drawing current from the power source. If the cable suffers an excessive voltage drop, the inverter may shut down when drawing higher currents because the voltage at the inverter dropped below 10 volts. #4 AWG stranded copper cable is recommended. It should be no longer than four feet (one and one-half meters). The end of the cable that connects to the inverter must have its insulation stripped off for about one-half inch (one and one-half cm) back from the end, exposing the bare copper. The other end of the cable, which connects to the power source, must be terminated with a lug or other connector that provides a secure, low resistance connection. For example, if the power source is a battery, the cable must be terminated with a battery terminal that clamps to the post on the battery. Quick Evaluation Before Installation Introduction Main Icons Assistance £ A test load that can be plugged into the AC receptacle on the inverter for short term testing at a low power level. The following cables are recommended for testing low power level test loads only. Installation Test Load Minimum Notes Test Load Intro Operation Power Customer Warranty Cable Size Assistance Secondary Icons 100W # 16 AWG copper 250W # 12 AWG copper 500W # 8 AWG copper Operation Intro Installation Warranty Notes To check your inverter’s performance installation: Caution before Warning Notice Secondary Icons Power Button 1. Turn the inverter off (see page 14 for details). If the power source is a DC power supply, switch it off Main Icons as well. Notice Caution Warning 2. Connect cables to power input Connect Terminals terminals (see page 8 for details). 3. Connect cables to power source (see page 8 for details). Main Icons Intro Operation Customer Warranty Assistance 4. Check to make sure all connections are secure. Connect Power Source Main Icons 5. Turn the inverter on. If the power source is a DC power supply, Installation Notes switch it Warranty on first. Intro Operation Customer Assistance Main Icons Secondary Icons Power Button 6. Plug in the test load. Intro Operation Customer Warranty The inverterAssistance should supply power to the load. If the inverter is not Installation Notes working properly, refer to the Caution Warning Notice troubleshooting guide on page 20 Secondary Icons Intro Operation Customer Installation Notesindicators Connect Test Load or power andWarranty protection Assistance section on page 16. Secondary Icons Notice Installation Caution Notice USB Outlet Secondary Icons 4 Customer Notice Warning NOTE A USB device can be usedNotes to check the output Caution Warning of the USB Outlet. Caution Warning Nothing Comes Close to a Cobra™ 5 on 10275_CPI1575_PH3 8:38 AM Page 6 Intro Intro Operation Installation Customer Assistance Operation Warranty Installation Requirements Notes Installation The inverter must be installed in an area that meets all of the following requirements: A. Dry Do not place in an area where water can drip or splash on the inverter. Caution Warning Notice B. Cool Ambient air temperature should be between 30°F and 105°F (0°C and 40°C). The cooler the better. C. Ventilate Allow at least one inch (three cm) of clearance around the inverter for proper airflow. Make sure that ventilation openings on the ends of the unit are not obstructed. D. Safe Do not install the inverter in the same compartment as a battery or in any compartment that contains flammable liquids such as gasoline. Warranty E. Close to Battery Install unit as close to battery as possible (without being in the same compartment) to minimize the length of cable required to connect the inverter to Notesthe battery. It is better and cheaper to run longer AC wires than longer DC wires (cables). Warning CAUTION To avoid fire, do not cover or obstruct ventilation openings. Do not install inverter in a zero-clearance compartment. Overheating may result. CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with a 6 volt battery, and will be damaged if it is connected to a 16 volt battery. 6 Customer Assistance Secondary Icons Notice Caution Warranty Mounting Installation • Secondary Icons Caution Operation Installation Secondary Icons Installation Customer Assistance Warranty Customer Assistance Intro Notes Installation Requirements on e 8/14/07 Notes WARNING This unit contains components which can produce arcs or sparks. To prevent fire Warning or explosion, do not install in compartments containing a battery or flammable materials, or in a location which requires ignition protected equipment. Notice Caution Warning WARNING This unit is suitable for installation in negative ground applications only. Do not attempt to install to a positive ground application. Mounting • To mount your inverter: 1. Place the inverter on a flat surface with the mounting bracket CPI 1575 against the mounting surface. DC TO AC INVERTER Mounting Brackets • 1500 watts continuous • 3000 watts peak • 5V usb output 2. Mount to secure surface using mounting hardware that is corrosion resistant (not included). Mounting Hardware The inverter can be mounted horizontally or vertically. If mounted vertically, neither end of the unit should be at the top (to avoid foreign material from falling or settling into the unit). Nothing Comes Close to a Cobra™ 7 10275_CPI1575_PH3 Intro Operation Installation 8/14/07 Customer Assistance 8:38 AM Page 8 Warranty Intro Connecting Cables Operation Warranty Connecting Cables Installation Installation Customer Assistance Installation Connecting Cables (not Notes included) • Power wire and wiring are very important to the performance of the inverter. Because the inverter has a low voltage, high current input, low resistance wiring is essential between the battery and inverter. This is so it can deliverNotice the maximum amount of energy to the load. Caution Warning Use only copper wire. Aluminum wire has about one-third more resistance than copper wire of the same size, plus it is difficult to make good, low-resistance connections to aluminum wire. We recommend #4 AWG copper cable (90°C insulation rating) as the minimum size for connections between the battery and inverter. Keep the cable length as short as possible, no more than four feet (one and a half meters). This will keep the voltage drop to a minimum. If the cable has too much voltage drop, the inverter may shut down when drawing higher currents because voltage at the inverter Main may Iconsdrop below 10 volts. If you must use longer cables, choose thicker cables, such as #2 AWG, and trim the ends of the cable to fit the terminals. Secondary Icons 2. On the end of the cable that Notes connects to the inverter, strip back the insulation about one-half inch (one and Secondary Icons one-half cm), exposing the bare copper conductor. Strip the Insulation Notice Caution Warning 3. Connect cable to the Power Input Terminals on input end of the inverter. The red terminal is positive (+) and the black terminal is negative (-). Insert the bare ends of the cables into the terminals and tighten the screws to clamp the wires securely. It is a good idea to check and tighten these screws from time to time. They can become loose by vibrations or thermal cycling. Insert Bare Cables To connect the cables between the inverter and the battery: Warranty Intro Operation Customer Assistance to the off 1. Press the Power Button on the inverter position. If the power source is a DC power supply, switch it off as well. Power Button Installation Notes Secondary Icons Notice 8 Caution 4. Connect cables to the power source: a. Connect the cable from the Negative (Black) Terminal of inverter to the Negative Terminal of the power source. Make a secure connection. Warning Nothing Comes Close to a Cobra™ 9 on 10275_CPI1575_PH3 8:38 AM Intro Intro Operation Customer Assistance Page 10 Operation Customer Assistance Warranty Warranty Intro Installation Installation Secondary Icons Installation Notes Icons b. Connect the cable from the Positive (Red) Main Terminal of the inverter to the Positive Terminal of the power Secondary Icons source (the battery’s main fuse or the battery selector Notice switch, if you are using one). Make a secure connection. Installation Secondary Icons Caution Warning Operation Customer Assistance Connect Cables Intro Notice Customer Assistance Caution Warning Secondary Icons Warning CAUTION Electrical installations must meet local and national wiring codes, and should be performed by a qualified electrician. CAUTION Do not connect the inverter and another AC source (such as a generator or utility power) to the AC wiring at the same time. The inverter will be damaged if its output is connected to AC voltage from another source. Damage can even occur if the inverter is switched off. CAUTION Do not connect the inverter to an AC branch circuit that has high-power consumption loads. It will not operate electric heaters, air conditioners, stoves, and other electrical appliances that consume more than 1500 watts. CAUTION Loose connectors result in excessive voltage drop and may cause over heated wires and melted insulation. Notice Customer Assistance Warranty Connecting Cables Notes CAUTION We recommend a main fuse in the battery’s positive cable to protect against DC wiring short circuits (external to the inverter). The fuse should be as close to the battery as possible. We recommend a Buss Fuse ANL-250 Warranty or equivalent. The specific fuse ampere rating Caution Warning Notice should be sized to allow operation of all your DC powered equipment. CAUTION Remove any jewelry (watch, ring, etc.). Be Notes careful not to short circuit the battery with any metallic object (wrench, etc.). Installation Warranty You might observe a spark when you make this connection since current can flow to charge capacitors in the inverter. Notes All power connections to your Cobra inverter must be Positive to Positive and Negative to Negative. Caution Operation Notes Connecting Cables Installation on e 8/14/07 Caution WARNING If you are making a permanent AC connection to the inverter, make sure that the AC wiring steps are performed before any DC wiring is Warning done. (DC hook-up energizes internal components, regardless of the position of the On/Off Switch). Working on AC connections in such a circumstance may result in an electric shock. WARNING 115 volt AC power is potentially lethal. Do not work on AC wiring when it is connected to the inverter (even if it is switched off) unless the DC power source is physically disconnected from the inverter. Also, do not work on AC wiring if it is connected to another AC power source such as a generator or the utility line. WARNING You may observe a spark when making the connection because current can flow to charge the capacitors in the inverter. Do not make this connection in the presence of flammable fumes. Explosion or fire may result. Thoroughly ventilate the battery compartment before making this connection. CAUTION Reverse polarity connections (positive to negative) will blow internal fuses in the inverter and may permanently damage the unit. Such damage is not covered by the warranty. 10 Nothing Comes Close to a Cobra™ 11 Warranty Intro Power Consumption Installation Notes In a vehicle: Connect the Chassis Ground to the chassis of the vehicle. In a boat: Connect to the Boat Grounding System. In a fixed location: Connect the Chassis Ground Screw to earth ground by connecting to a ground rod (a metal rod pounded into the earth) or other proper service entrance ground. Main Icons Operation Customer Assistance Warranty 115 watts x 3 hours = 345 watt-hours Chassis Ground Intro 100 watts x 2 hours = 200 watt-hours TV/VCR (up to 25") • There is a screw on the rear panel for Chassis Ground. This is to connect the chassis of the inverter to ground. The Chassis Ground Screw must be connected to a grounding point, which will vary depending on where the unit is Notice installed. Use copper wire Cautiona #8 AWG Warning (preferably with green/yellow insulation) to connect the chassis ground screw to the grounding point. Secondary Icons Notes For each piece of equipment you will be operating from the inverter, you must determine the battery’s reserve capacity (how long the battery can deliver a specific amount of current – in automotive batteries, usually 25 ampere) or ampere-hour capacityCaution (a measure of how many amperes a Warning Notice battery can deliver for a specified length of time). Example – Reserve capacity: a battery with a reserve capacity of 180 minutes can deliver 25 ampere for 180 minutes before it is completely discharged. Example – Ampere-hour capacity: a battery with an ampere-hour capacity of 100 ampere-hours can deliver 5 ampere for 20 hours before it is completely discharged. To determine the battery ampere-hour capacity you require: 1. Determine how many watts each piece of equipment consumes. This can normally be found on the product label. If only the current draw is given, multiply the current draw by 115 to get the watt consumption. 2. Estimate the time (in hours) that each piece of equipment will be running between battery charging cycles. 3. Calculate the total watt-hours of energy consumption (power x operating time) using the average power consumption and the total estimated running time (in hours). Power x Operating Time = Watt-Hours. Notes Ground Wiring • Warranty Ground Wiring Installation Secondary Icons Laptop Customer Assistance Installation Installation Power Consumption Operation Secondary Icons Installation Customer Assistance Page 12 Warning Operation 8:38 AM Caution Intro 8/14/07 Notice 10275_CPI1575_PH3 Blender 300 watts x 15 minutes = 75 watt-hours 4. Divide the watt-hours by 10 to determine how many battery (12 volt) ampere-hours will be consumed. 12 Nothing Comes Close to a Cobra™ 13 10275_CPI1575_PH3 8/14/07 8:38 AM Page 14 Main Icons Main Icons Power On and Off Operation Intro Operation Customer Warranty Intro Assistance Turning Your Inverter On or Off • Main Icons Be sure to have your power inverter properly installed before attempting to turn the unit on (see installation page 6). Installation To turn the power inverter on: Notes Secondary Intro is being Operationused Customer Warranty 1.IconsIf a DC power supply as the power Assistance source, switch it on. 2. On the Output End, press the Power Button to on. Power Button Notice Caution Installation Remote On/Off Switch Operation Operation Warranty • An optional Remote On/Off Switch (see page 24 to order accessories) can be connected to the Remote Jack allowing you to turn the Cobra power inverter on or off Installation from a convenient location whenNotes the inverter is installed Main Icons in an out of reach location. Secondary Icons Remote Switch Notes Warning Customer Remote On/Off Assistance Switch Notice Caution Intro Warning Operation Customer Assistance Warranty Secondary Icons Main Icons Installation Notes Remote Jack Notice Intro Operation Customer Caution Warning Secondary Icons Warranty Assistance The inverter is now ready to deliver AC power to your loads. If several loads are to be operated by the inverter, turn them on separately, after the inverter has been turned on. This will ensure that the inverter does not have to deliver Installation Notes the starting currents required for all the loads at once. Notice Caution Warning Secondary Icons Notice 14 NOTE The Power Button turns the control circuit in the inverter on and off. It does not disconnect power inverter. Cautionfrom the Warning When the button is in the off position, the inverter draws no current from the battery. When it’s in the on position, but no power is being supplied to a load, the inverter draws less than 600 milliamperes from the battery. This is low current draw. It would take more than a week to discharge a 100 amperehour battery at this rate depending on the age of the battery. Nothing Comes Close to a Cobra™ 15 10275_CPI1575_PH3 8/14/07 8:38 AM Page 16 Main Icons Main Icons Operating Indicators Operation Intro Operation Customer Assistance Operating Indicators Operating Indicators Operation Warranty Intro • Operation Low Voltage Indicators at the Output End of the unit show the unit’s power status and alarms for conditions that could cause it to shut down. Installation Installation Notes Secondary Icons Secondary Icons Output Watts Notice Over Current Short Circuit 16 Caution Warning Power on – The Voltage Input and Power Output indicators automatically toggle between input and output values at three-second intervals. The three LEDs indicate the mode the meter is in and the three digits indicate the voltage or power value. Current Overload Protection – If the inverter is overloaded, it will shut down to protect itself. The meter will flash as shown to indicate Overload Protect. To restore normal operation, disconnect the excessive load and turn the unit Off and On again using the Power Button. Short Circuit Protection – If the AC output of the inverter is shortcircuited for one second or more, it will shut down to protect itself. The meter will flash as shown to indicate Short Circuit Protect and an alarm will sound. To restore normal operation, disconnect the short circuit and turn the unit Off and On again using the Power Button. Notice High Voltage Customer Assistance Warranty Low Voltage Protection – If the DC input voltage drops below the alarm threshold of 10.5V the meter will flash as shown to indicate Notes Low Voltage Protection, but the unit will continue to operate. If the input voltage drops to 10.0V or less, the inverter will shut down to protect itself, the meter will continue to flash as shown, and an alarm will sound. Caution Warning To restore normal operation, return the DC input voltage to at least 12V. The inverter will automatically return to normal operation. High Voltage Protection – If the DC input voltage rises above 15.0V, the inverter will shut down to protect itself, the meter will flash as shown to indicate Over Voltage Protection, and an alarm will sound. To restore normal operation, return the DC input voltage to less than 15V. The inverter will automatically return to normal operation. Nothing Comes Close to a Cobra™ 17 10275_CPI1575_PH3 8/14/07 8:38 AM Page 18 Main Icons Main Icons Operating Indicators Operation Operation Intro Customer Assistance Warranty Over Temperature Protection – If the internal inverter temperature rises above the alarm threshold, the meter will flash as shown, an alarm will sound to indicate Over Installation Notes Temperature Protect, and the unit Intro Operation Customer willAssistance continueWarranty to operate. If the internal temperature rises to 40ºC (104ºF), the inverter will shut down to protect itself, the meter will and the alarm will Installation flash as shown Notes Caution Notice continueWarning to sound. High Temperature Operating Limits Operation Intro Operation Customer Assistance Operating Limits Warranty • Main Icons Secondary Icons Secondary Icons Notice 18 NOTE Internal inverter temperature can rise due to being operated in a high heat environment or due to the Caution Warning fan or vents being blocked during operation (even in relatively cool outside air). To restore normal operation, turn the unit Off and allow it to cool. The inverter will automatically return to normal operation after it has cooled. Power Output The inverter can deliver 1500 watts for about 60 minutes. The inverter must cool for 15 minutes before it can Installation resume operation at 1500 watts.Notes Note: The wattage rating applies to resistive loads. Secondary Icons The inverter will operate most AC loads within its power rating. Some induction motors used in freezers, pumps, and other motor-operated equipment require very high surge currents to start. The inverter may not be able Caution Warning Notice to start some of these motors even though their rated current draw is within the inverter’s limits. The inverter will normally start single phase induction motors rated at one-half HP or less. Input Voltage The inverter will operate from input voltage ranging from 10 volts to 15 volts. Optimum performance will occur when the voltage is between 12 volts and 14 volts. If the voltage drops below 10.5V+/- 0.3V, an audible low battery warning will sound. The inverter will shut down if the input voltage drops below 9.5V+/- 0.3V. This protects the battery from being over-discharged. It will restart when the input voltage exceeds 12V+/- 0.3V. The inverter will also shut down if the input voltage exceeds 15.5V +/- 0.5V. This protects the inverter against excessive input voltage. Although the inverter has protection against over-voltage, it may still be damaged if the input voltage were to exceed 16 volts. Nothing Comes Close to a Cobra™ 19 10275_CPI1575_PH3 8/14/07 8:38 AM Page 20 Main Icons Main Icons Troubleshooting Guide Operation Intro Operation Customer TroubleshootingAssistance Guide Warranty Secondary Icons No output voltage Thermal after prolonged use shutdown Notice Caution Warning No output voltage, High input “Protect” indicator voltage lighted No output voltage Short circuit No output voltage Inverter switched off No power to inverter Reverse DC polarity Low battery alarm Poor DC wiring on all the time Poor battery condition 20 Intro • Problem/Symptom Possible Causes Low output voltage Overload No outputInstallation voltage Low input Notes voltage Specifications Operation Solution Reduce the load. Recharge battery. Check connections and cable. Allow inverter to cool off. Reduce load, continuous operation input current required. Improve ventilation; Make sure ventilation openings in the inverter are not obstructed. Reduce ambient temperature. Make sure the inverter is connected to 12V battery. Check regulation of charging system. Check load for proper operation. Turn inverter on. Operation Specifications Customer Assistance Warranty • Continuous output power (1 hour) . . . . . . . . . . . 1500W Surge rating (0.1 second) . . . . . . . . . . . . . . . . . . 3000W Peak efficiency (12V – 1⁄2 load) . . . . . . . . . . . . . . > 88% Installation Notes Efficiency (full load, 12V) . . . . . . . . . . . . . . . . . . . > 83% Secondary Icons No load current draw . . . . . . . . . . . . . . . . < 0.6A (12.6V) Output waveform (resistive load) . . . Modified sine wave Output frequency . . . . . . . . . . . . . . . . . . . . 58HZ – 62HZ Output voltage . . . . . . . . . . . . . . . . . . . . . . 109V – 120V USB outputNotice . . . . . . . Caution . . . . . . . . . Warning . . . . . . . . . . . . . . . . . 5V Input voltage . . . . . . . . . . . . . . . . . . 10.4VDC – 14.4VDC Alarm voltage (unload) . . . . . . . . . . . . . . .10.2V – 10.8V Shutdown voltage (unload) . . . . . . . . . . . . . 9.2V – 9.8V Operating temperature range . . . . . . . . . . . . 0°C – 40°C (32°F – 104°F) Storage temperature range . . . . . . . . . . . . -40°C – 85°C (-40°F – 185°F) Protection . . . . . . . . . .Overload, short-circuit, overtemp, reverse polarity, under/over voltage Notes All protection is automatically recovered. To protect the battery, if the unit needs to be restarted after low voltage protection, the voltage of DC input should be above 12V. To extend the life of the fan, it will stop when there is no load. The speed of the fan increases as the load increases. The unit is completely insulated in input and output for added safety. Check wiring to inverter. Observe correct polarity. Check connections. Make sure battery is fully charged. Nothing Comes Close to a Cobra® 21 10275_CPI1575_PH3 8/14/07 8:38 AM Page 22 Main Icons Warranty and Trademark Acknowledgement Warranty Operation Customer Assistance Customer Assistance Warranty Limited Two-Year Warranty Intro • For Products Purchased in the U.S.A. Installation Notice Cobra Electronics Corporation warrants that its Cobra power inverter, and the component parts thereof, will be free of defects in workmanship Notes and materials for a period of two years from the date of first consumer purchase. This warranty may be enforced by the first consumer purchaser, provided that the product is utilizedSecondary Icons within the U.S.A. Cobra will, without charge, repair or replace, at its option, defective power inverters, products or component parts upon delivery to the Cobra Factory Service department, accompanied by proof of the Caution date of firstWarning consumer purchase, such as a duplicated copy of a sales receipt. You must pay any initial shipping charges required to ship the product for warranty service, but the return charges will be at Cobra’s expense, if the product is repaired or replaced under warranty. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. Operation Maintenance and Product Service Customer Maintenance Assistance Warranty • Very little maintenance is required to keep the inverter operating properly. The exterior of the unit should be cleaned periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals. Be sure Installation vents and fans are freeNotes of dust or debris. Product Service • For any questions about operating or installing this new Cobra product, or if parts are missing…PLEASE CALL COBRA FIRST…do not return this product to the store. See customer assistance on page A1. Notice Caution Warning If your product should require factory service, please call Cobra first before sending your power inverter. This will ensure the fastest turn-around time on your repair. You may be asked to send your power inverter to the Cobra factory. It will be necessary to furnish the following to have the product serviced and returned. 1. For warranty repair include some form of proof-of-purchase, such as a mechanical reproduction or carbon copy of a sales receipt. If you send the original receipt, it cannot be returned. Exclusions: This limited warranty does not apply: 1. To any product damaged by accident. 2. In the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. 2. Send the entire product. 3. If the serial number has been altered, defaced, or removed. 3. Enclose a description of what is happening with the power inverter. Include a typed or clearly printed name and address of where the power inverter is to be returned. 4. If the owner of the product resides outside the U.S.A. All implied warranties, including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty. Cobra shall not be liable for any incidental, consequential or other damages; including, without limitation, to damages resulting from loss of use or cost of installation. Some states do not allow limitations on how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you. For Products Purchased Outside the U.S.A. Please contact your local dealer for warranty information. Trademark Acknowledgement Cobra®, Nothing Comes Close to a Cobra® and the snake design are registered trademarks of Cobra Electronics Corporation, USA. Cobra Electronics Corporation™ is a trademark of Cobra Electronics Corporation, USA. 22 • 4. Pack power inverter securely to prevent damage in transit. If possible, use the original packing material. 5. Ship prepaid and insured by way of a traceable carrier such as United Parcel Service (UPS) or Priority Mail to avoid loss in transit to: Cobra Factory Service Cobra Electronics Corporation 6500 West Cortland Street Chicago, Illinois 60707 USA. 6. If the power inverter is in warranty, upon receipt of your power inverter, it will either be repaired or exchanged depending on the model. Please allow approximately three to four weeks before contacting Cobra for status. If the power inverter is out of warranty, a letter will automatically be sent informing you of the repair charge or replacement charge. If you have any questions, please call 773-889-3087 for assistance. Nothing Comes Close to a Cobra™ 23 10275_CPI1575_PH3 8/14/07 8:38 AM Page 24 n Icons Customer Assistance Intro ondary Icons Accessories and Order Form Operation Customer Remote On/Off Assistance Switch (CPI A20) Installation AnWarranty optional Remote On/Off Switch can be connected to the Remote Jack allowing you to turn the Cobra CPI 1575 inverter on or off from a convenient location when the inverter is installed in an out of reach location. Notes Name Address (No P.O. Boxes) City Notice State/Province Caution Zip Country Warning Telephone Credit Card Number Type: ❒ Visa ❒ Mastercard ❒ Discover Exp. Date Customer Signature Optional Accessories You can find quality Cobra products and accessories at your local Cobra dealer, or in the U.S.A., you can order directly from Cobra. Ordering from U.S.A. Call 773-889-3087 for pricing or visit www.cobra.com. For credit card orders, complete and return this order form to fax number 773-622-2269. Or call 773-889-3087 (Press 1 from the main menu) 8:00 a.m. to 6:00 p.m. CT, Monday through Friday. Make check or money order payable to: Cobra Electronics, Attn: Accessories Dept. 6500 West Cortland Street, Chicago, IL 60707 USA To order online, please visit our website: www.cobra.com 24 •
Устройство:
Cobra Electronics CPI 1575
Размер: 1,19 MB
Добавлено: 2014-02-25 17:36:32
Количество страниц: 15
Печатать инструкцию
Скачать
Как пользоваться?
Наша цель — обеспечить Вам самый быстрый доступ к руководству по эксплуатации устройства Cobra Electronics CPI 1575. Пользуясь просмотром онлайн Вы можете быстро просмотреть содержание и перейти на страницу, на которой найдете решение своей проблемы с Cobra Electronics CPI 1575.
Для Вашего удобства
Если просмотр руководства Cobra Electronics CPI 1575 непосредственно на этой странице для Вас неудобен, Вы можете воспользоваться двумя возможными решениями:
- Полноэкранный просмотр -, Чтобы удобно просматривать инструкцию (без скачивания на компьютер) Вы можете использовать режим полноэкранного просмотра. Чтобы запустить просмотр инструкции Cobra Electronics CPI 1575 на полном экране, используйте кнопку Полный экран.
- Скачивание на компьютер — Вы можете также скачать инструкцию Cobra Electronics CPI 1575 на свой компьютер и сохранить ее в своем архиве. Если ты все же не хотите занимать место на своем устройстве, Вы всегда можете скачать ее из ManualsBase.
Cobra Electronics CPI 1575 Руководство по эксплуатации
Печатная версия
Многие предпочитают читать документы не на экране, а в печатной версии. Опция распечатки инструкции также предусмотрена и Вы можете воспользоваться ею нажав на ссылку, находящуюся выше — Печатать инструкцию. Вам не обязательно печатать всю инструкцию Cobra Electronics CPI 1575 а только некоторые страницы. Берегите бумагу.
Резюме
Ниже Вы найдете заявки которые находятся на очередных страницах инструкции для Cobra Electronics CPI 1575. Если Вы хотите быстро просмотреть содержимое страниц, которые находятся на очередных страницах инструкции, Вы воспользоваться ими.
Смотреть руководство для Cobra PRO 1500W ниже. Все руководства на ManualsCat.com могут просматриваться абсолютно бесплатно. Нажав кнопку «Выбор языка» вы можете изменить язык руководства, которое хотите просмотреть.
MANUALSCAT | RU
Вопросы и ответы
У вас есть вопрос о Cobra PRO 1500W, но вы не можете найти ответ в пользовательском руководстве? Возможно, пользователи ManualsCat.com смогут помочь вам и ответят на ваш вопрос. Заполните форму ниже — и ваш вопрос будет отображаться под руководством для Cobra PRO 1500W. Пожалуйста, убедитесь, что вы опишите свои трудности с Cobra PRO 1500W как можно более детально. Чем более детальным является ваш вопрос, тем более высоки шансы, что другой пользователь быстро ответит на него. Вам будет автоматически отправлено электронное письмо, чтобы проинформировать вас, когда кто-то из пользователей ответит на ваш вопрос.
Задать вопрос о Cobra PRO 1500W
- Бренд:
- Cobra
- Продукт:
- батареи
- Модель/название:
- PRO 1500W
- Тип файла:
- Доступные языки:
- английский
Сопутствующие товары Cobra PRO 1500W
Перед началом работы со сварочным оборудованием для полипропиленовых труб, следует тщательно проверить исправность аппарата, наличие всех необходимых инструментов (рулетки, метра, уровня, ножа или ножниц и т.д.), и принять меры по собственной защите.
При настройке самого аппарата очень важно внимательно следовать инструкции, подготовить инструмент перед началом работ (очистить покрытие нагревательных элементов, установить и закрепить насадки, выставить нужную температуру). Когда предварительная подготовка выполнена, можно включать сварочный аппарат и ждать пока он нагреется. Обычно, сварочное оборудование (например, такое как аппарат GM COBRA) нагревается быстро, поэтому еще до включения прибора в сеть должен быть подготовлен непосредственно свариваемый материал, тоесть трубы. Трубу, с которой вы будете работать, нужно разметить, отрезать нужный кусок, очистить от загрязнений, следов окисления и жира. При работе с фитингами, наружный конец трубы рекомендуется слегка «стесать» ножом, примерно на 30-40 градусов.
Необходимо периодически выключать аппарат, чтоб он не вышел из строя!!!
Если вы работаете с трубами небольших диаметров, тут можно воспользоваться обычной ручным креплением трубы (другими словами, трубу можно держать в руках). При больших диаметрах специалисты рекомендуют использовать дополнительные крепежные приспособления.
Также крайне важно соблюдать время сварки, которое значительно отличается в зависимости от диаметра трубы. По окончании работ обязательно нужно отключить аппарат и отсоединить все инструменты.
Каталог товаров
Предназначен для сварки труб и фитингов из полипропилена диаметром от 16 до 90 мм. Нагревательный блок с термостатом состоит из двух элементов из нержавеющей стали с индивидуальной индикацией на корпусе.
Мощность — 1500 Вт, двухступенчатый (2х75Вт) 50Гц.
Диапозон регулирования температуры — 50оС-300оС
Кабель- термостойкий в силиконовой изоляции
Комплектация:
- Ящик металлический — 1шт
- Сварочный аппарат — 1шт
- Струбцина для крепления аппарата — 1шт
- Парные сменные нагреватели с тефлоновым покрытием — ? 20, 25, 32, 40 по 1 шт
- Рулетка 3м — 1шт
- Ножницы до ? 40мм — 1шт
- Ключ шестигранный — 1шт
- Отвертка — 1шт
- Паспорт изделия — 1шт
Материал корпуса: алюминий
Документация
Способы получения заказов в Москве и Химках
Доставка: Москва — 500 руб., + 50 руб/км за МКАД. Вся Россия — по тарифам транспортных компаний подробнее »
Режим работы службы доставки:
пн-пт: 14:00 — 22:00;
сб: 10:00 — 17:00
вс: выходной
Самовывоз: бесплатно
Адрес магазина в Москве:
Москва, Ленинский пр-т, дом 110 корпус 1
• м. Проспект Вернадского • м. Октябрьская
пн-пт: 9:00 до 19:00
сб: 10:00 до 15:00
вс: — выходной
Адрес пункта самовывоза в Химках:
Московская область, г. Химки, мкр. Подрезково, кв-л Кирилловка, вл.2, стр 1, офис №6.
пн-пт: 9:00 до 18:00
сб, вс: — выходной
Без предварительного заказа на сайте или по телефону наличие товара не гарантируется
Похожие товары
С данным товаром также покупают:
* Производитель оставляет за собой право без уведомления продавца менять характеристики, внешний вид, комплектацию товара и место его производства
Указанная информация не является публичной офертой
Обратная связь
Если Вам понравилось обслуживание в нашем магазине, оставьте, пожалуйста, отзыв о нашем
магазине на
Яндекс Маркете! Это не займет много времени, а нашей компании поможет повысить качество
обслуживания.