COOLMAY EX3G PLC/HMI All in one Programming manual

COOLMAY

EX3G PLC/HMI All in one

Programming manual

(plc part: Difference comparing with Mitsubishi FX3G)

All right belongs to Shenzhen Coolmay Technology Co.,Ltd

V8.112

loading

Related Manuals for Coolmay EX3G-43HB-24M

Summary of Contents for Coolmay EX3G-43HB-24M

  • Page 1
    COOLMAY EX3G PLC/HMI All in one Programming manual COOLMAY EX3G PLC/HMI All in one Programming manual (plc part: Difference comparing with Mitsubishi FX3G) All right belongs to Shenzhen Coolmay Technology Co.,Ltd V8.112…
  • Page 2: Table Of Contents

    COOLMAY EX3G PLC/HMI All in one Programming manual Content 1. Overview …………………………… 1 1.1 EX3G PLC/HMI Allin one Main Advantage: ………………1 1.2 Specification ……………………….2 1.3 Hardware description ……………………..3 1.3.1 EX3G-43HA/HB structure description and dimension ………….. 3 1.3.2 EX3G-43(50)KH structure description and dimension ………….. 4 1.3.3 EX3G-70KH structure description and dimension …………..

  • Page 3
    COOLMAY EX3G PLC/HMI All in one Programming manual 3.3 Introduction when HMI is with com port for MODBUS RTU protocol ……….66 3.3.1 HMI as master …………………….. 66 3.3.2 HMI as slave ……………………..68 3.4 Other HMI usage……………………..69…
  • Page 4: Overview

    COOLMAY EX3G PLC/HMI All in one Programming manual 1. Overview 1.1 EX3G PLC/HMI Allin one Main Advantage: ◆Powerful, compatible with FX3G/FX3U/FX3S PLC, high processing speed. ◆Upper computer programming software compatible with Works 2/GX Developer8.86 ◆Military level 32 bit CPU adopted, which is faster and more adapted to industrial environment of high electromagnetic interference.

  • Page 5: Specification

    Regular models:EX3G-43HB/43KH/50KH-16MR/24MR/24MT(-4AD2DA-485P/232H) EX3G-70KH100HA-16MR/24MR/44MT/44MRT(-16AD8DA-485P/232H) *EX3G-70HA/100HA: If with 30DI/30DO,the maximum analogs are 5AD/2DA;If with 24DI/20DO,the maximum analogs are 16AD/8DA; Detailed info.refer to:《Coolmay HMI/PLC All-in-on Programming Manual》 《HMI/PLC All-in-one User Manual》 《CoolMay HMI User Manual》 《EX3G PLC/HMI Programming Manual》 《EX3G PLC/HMI User Manual》…

  • Page 6: Hardware Description

    COOLMAY EX3G PLC/HMI All in one Programming manual 1.3 Hardware description 1.3.1 EX3G-43HA/HB structure description and dimension PLC Run light Com port of plc and hmi Power light * Dimension(mm):134*102*30 * Cutout size(mm): 119*93 * Installation: Clip installation * Display size(mm): 97*56…

  • Page 7: Ex3G-43(50)Kh Structure Description And Dimension

    COOLMAY EX3G PLC/HMI All in one Programming manual 1.3.2 EX3G-43(50)KH structure description and dimension PLC Run light Com port of plc and hmi Power light * Dimension(mm):150*93*32 * Cutout size(mm):143*86 * Installation: Clip installation * Display size(mm): EX3G-43KH:97*56 EX3G-50KH:108*65…

  • Page 8: Ex3G-70Kh Structure Description And Dimension

    COOLMAY EX3G PLC/HMI All in one Programming manual 1.3.3 EX3G-70KH structure description and dimension PLC Run light Com port of plc and hmi Power light * Dimension(mm):226*163*35.6 * Cutout size(mm): 218*153 * Installation: Clip installation * Display size(mm): 154*87…

  • Page 9: Ex3G-100Ha Structure Description And Dimension

    COOLMAY EX3G PLC/HMI All in one Programming manual 1.3.4 EX3G-100HA structure description and dimension PLC Run light Com port of plc and hmi Power light * Dimension(mm):275*194*36 * Cutout size(mm): 261*180 * Installation: Clip installation * Display size(mm): 222*133…

  • Page 10: Introduction Of Each Interface And Indicator

    COOLMAY EX3G PLC/HMI All in one Programming manual 1.3.5 Introduction of each interface and indicator POWER: Power indicator, connected to the power light RUN: PLC running status indicator. This light is on when the PLC is running. COM: touch screen and PLC communication status indicator, when the two communicate, the light is on Power terminal: The positive and negative terminals of the DC24V switching power supply are respectively connected to the DC24V and 0V of the power supply terminal.

  • Page 11: Plc

    COOLMAY EX3G PLC/HMI All in one Programming manual 2. PLC 2.1 PLC Programming notice The PLC is compatible with GX 8.86/Works 2 and below. If you use other versions of the software, incompatibility may occur. When the PLC program is downloaded, there is a prompt error: Cannot specify the com port, GX 8.86 software: Online — Transfer settings change com port;…

  • Page 12
    COOLMAY EX3G PLC/HMI All in one Programming manual EEPROM hold S10~S899 890 points Signal Alert (EEPROM hold) S900~S999 100 points General*1 S1000~S4095 3096 points Timer (ON delay timer) 100ms 200 points T0~T191 0.1~3,276.7s ※1 T200~T245 46 points 0.01~327.67s 10ms 1ms accumulative 4 points T246~T249…
  • Page 13: Special Relay Number And Content

    COOLMAY EX3G PLC/HMI All in one Programming manual Constant 16 bit -32,768~+32,767 Decimal (K) 32 bit -2,147,483,648~+2,147,483,647 16 bit 0~FFFF Hexadecimal (H) 32 bit 0~FFFFFFFF Real number(E)*3 -1.0×2128~-1.0×2-126,0,1.0×2-126~1.0×2128 32 bit Can be in the form of a decimal point and index *1: The 10ms timer will be affected by the scan cycle.

  • Page 14
    COOLMAY EX3G PLC/HMI All in one Programming manual Content Remarks Content Remarks M8052 Input interrupt (I20 is prohibited) M8252 C252 Increase/decrease counting action M8053 Input interrupt (I30 is prohibited) M8253 C253 Increase/decrease counting action M8054 Input interrupt (I40 is prohibited)
  • Page 15
    COOLMAY EX3G PLC/HMI All in one Programming manual Content Remarks Content Remarks M8152 6 pulse operation monitoring M8364 Y002 reverse limit Y002 near-point DOG signal logic M8153 7 pulse operation monitoring M8365 inversion M8154 8 pulse operation monitoring M8366 Y002 zero signal logic inversion…
  • Page 16: Special Register Number And Content

    COOLMAY EX3G PLC/HMI All in one Programming manual Content Remarks Content Remarks action 2.11.4 C209 Increase/decrease counting M8209 M8423 RS2 command reception end action C210 Increase/decrease counting M8210 M8424 RS2 command data in reception action C211 Increase/decrease counting M8211 M8425…

  • Page 17
    COOLMAY EX3G PLC/HMI All in one Programming manual Content Remarks Content Remarks 8…8K steps; When 16K steps and above, D8002=8,D8102 is corresponded to 16,32,64 10H:Programmable D8003 Memory type controller built-in D8169 Restrict access status memory D8010 Scan current value D8182 Z1 Register contents…
  • Page 18
    COOLMAY EX3G PLC/HMI All in one Programming manual Content Remarks Content Remarks D8051 DA1 analog output value D8354 High Y1 crawling speed D8052 DA2 analog output value D8355 Initial value: 1000 D8053 DA3 analog output value D8356 Y1 Origin return speed…
  • Page 19
    COOLMAY EX3G PLC/HMI All in one Programming manual Content Remarks Content Remarks number D8102 PLC memory capacity 16…16K steps D8410 RS2 header 1, 2 <initial value: STX> D8108 Number of special modules connected D8411 RS2 header 3, 4 D8109 Y number of output refresh error D8412 RS2 trailer 1, 2 <initial value: ETX>…
  • Page 20: Applied Instructions【Sequence Is According To Instruct Variety

    COOLMAY EX3G PLC/HMI All in one Programming manual M8084~M8119, M8130~M8159, M8161~M8169, M8178~M8191, M8256~M8339, M8370~M8395, M8430~M8511. ※ special register not supported D8004~D8009, D8042~D8067, D8069~D8073, D8105~D8119, D8150~D8168, D8200~D8329, D8468~D8511. Specific functions please refer to 《Mitsubishi FX3G programming manual》 2.5 Applied instructions【Sequence is according to instruct variety】…

  • Page 21
    COOLMAY EX3G PLC/HMI All in one Programming manual 1. Data move instructions Mnemonic FNC No. Function Support Move ★ SMOV Shift Move ★ Compliment ★ BMOV Block Move ★ FMOV Fill Move ★ PRUN Parallel Run (Octal Mode) ★ Exchange ★…
  • Page 22
    COOLMAY EX3G PLC/HMI All in one Programming manual AND>= Contact compare AND (S1)≧(S2) ★ Contact compare OR (S1)=(S2) ★ OR> Contact compare OR (S1)>(S2) ★ OR< Contact compare OR (S1)<(S2) ★ OR<> Contact compare OR (S1)≠(S2) ★ OR<= Contact compare OR (S1)≦(S2) ★…
  • Page 23
    COOLMAY EX3G PLC/HMI All in one Programming manual 6. Special function instructions Mnemonic FNC No. Function Support Square Root ★ ESQR Floating Point Square Root ★ Floating Point Exponent ★ Floating Point Natural Logarithm LOGE ★ LOG10 Floating Point Common Logarithm ★…
  • Page 24
    COOLMAY EX3G PLC/HMI All in one Programming manual Negation ★ ENEG Floating Point Negation ★ WTOB WORD to BYTE ★ BTOW BYTE to WORD ★ 4-bit Linking of Word Data ★ 4-bit Grouping of Word Data ★ Check Code ★…
  • Page 25
    COOLMAY EX3G PLC/HMI All in one Programming manual SRET Subroutine Return ★ IRET Interrupt Return ★ Enable Interrupt ★ Disable Interrupt ★ FEND Main Routine Program End ★ Start a FOR/NEXT Loop ★ NEXT End a FOR/NEXT Loop ★ 12. I/O refresh instructions Mnemonic FNC No.
  • Page 26
    COOLMAY EX3G PLC/HMI All in one Programming manual IVRD Inverter Parameter Read IVWR Inverter Parameter Write IVBWR Inverter Parameter Block Write IVMC Inverter multiple command ADPRW MODBUS read and write ★ 16. Special block/unit control instructions Mnemonic FNC No. Function…
  • Page 27: Analog Input

    D8001, D8101, if necessary, please query the value of D8001. Input precision of coolmay CX3G/FX3GC PLC and EX3G plc hmi all-in-one is 12-bit, directly read the corresponded register value of each analog while using. Environment temperature is only used in thermocouple.

  • Page 28
    COOLMAY EX3G PLC/HMI All in one Programming manual (Negative temp) PT100/PT1000 -200~350℃ -2000~3500 0.1℃ -48~210℃ -480~2100 0.1℃ Voltage 0~10V/0-5V 0~4000 2.5mV Current Type1 0~20mA 0~4000 Current Type2 4~20mA 0~4000 Below table for software version 26230 and above Accuracy Input signal…
  • Page 29: Analog Input Reading 1 (For Software Version 26210 And 26220)

    COOLMAY EX3G PLC/HMI All in one Programming manual 2.6.2 Analog input reading 1 (for software version 26210 and 26220) Support FROM instruction or register directly read. Such as: FROM K0 K0 D400 K16, read out 16 analog input, 0-10V. K type thermocouple (1~4 channel) are in the 4 registers from R23680, the 5 is temperature compensation, R23684 reveals the environment temperature.

  • Page 30: Analog Input Reading 2 (For Main Software Version 26220)

    COOLMAY EX3G PLC/HMI All in one Programming manual AD13 R23653 R23673 D8043 R23633 AD14 R23654 R23674 D8044 R23634 AD15 R23655 R23675 D8045 R23635 When 4~20mA,<3.8mA,value is 32760,which is the disconnection value. 2.6.3 Analog input reading 2 (for Main software version 26220)

  • Page 31: Analog Input Sampling

    COOLMAY EX3G PLC/HMI All in one Programming manual D8037 D8038 D8039 AD10 D8040 AD11 D8041 AD12 D8042 AD13 D8043 AD14 D8044 D8045 AD15 When the analog input has a thermocouple type, it can only do up to 15 channels, of which AD4 is the ambient temperature of the thermocouple.

  • Page 32: Demo Example

    COOLMAY EX3G PLC/HMI All in one Programming manual 2.6.6 Demo example Below is an example of EX3G 1 channel temperature analog AD0 acquisition. The program reads the values as follows: Connect the signal terminal of the temperature sensor to the AD0 input of the PLC and the other end to the GND of the analog input port.

  • Page 33: Analog Output

    COOLMAY EX3G PLC/HMI All in one Programming manual In the above figure, when M0 is closed, the value -100 is transmitted to the correction register R23960, and now you can see that the value of the actual measured temperature D20 is close to the actual temperature which is 37.9 °C.

  • Page 34: Application Of High Speed Pulse

    2.10.Application of high speed pulse 2.10.1 high speed pulse output Coolmay CX3G default has 8 channels high speed pulse, Y0-Y3 each 100KHz, Y4-Y7 each 10KHz,variable speed supported, the initial/final speed of start/stop is 0, diagram as below: (take accelerate and decelerate time D8148 as an example).

  • Page 35: Circular Interpolation

    COOLMAY EX3G PLC/HMI All in one Programming manual Acceleration/deceleration time T calculation= (target speed-current speed) * acceleration/deceleration time÷maximum speed. For example, target speed = 50000, current speed = 20000, acceleration time 100 (ms), maximum speed = 100,000, T = 30 ms.

  • Page 36
    M8344=0,relative position; M8344=1,absolute position. D8340 shows the current address of X axis,D8350 shows the current address of Y axis. In CoolMay 3G PLC,interpolation motion still adopts DPLSR for pulse output. Description of the Operand: represents the pulse frequency, that is, the speed of the interpolation motion.
  • Page 37: Continuous Interpolation Function

    2.10.3 Continuous interpolation function M8436 is the flag for the normal interpolation mode and continuous interpolation mode. M8436=0: regular interpolation mode; M8436=1: continuous interpolation mode; In CoolMay 3G PLC 26236 and higher version, continuous interpolation motion uses DPLSR for pulse output.

  • Page 38
    COOLMAY EX3G PLC/HMI All in one Programming manual Operand Description: All use 32-bit registers. S1. indicates the pulse frequency, that is, the speed of the interpolation motion. S2. indicates the X-axis target address. S2.+2 indicates the Y-axis target address. In the center mode: S2.+4 and S2.+6 indicates the Center coordinates.
  • Page 39
    COOLMAY EX3G PLC/HMI All in one Programming manual Program as below :…
  • Page 40: Plc Communication Port User Manual

    COOLMAY EX3G PLC/HMI All in one Programming manual 2.11 PLC Communication port User Manual PLC defaulted has a RS232 programming port, and two communication ports ( Rs232 or Rs485) can be added. Meanwhile, CANbus is also optional. 2.11.1 Serial port 2: RS485(A B)/RS232 Support MITSUBISHI programming port protocol,Mitsubishi BD board protocol,RS protocol and MODBUS protocol;…

  • Page 41
    COOLMAY EX3G PLC/HMI All in one Programming manual Main version 26232 or higher RD3A/WR3A interval period D8126 D8406 D8426 version RD3AWR3A end operation -1 Main version 26232 or higher ADPRW command settings D8126=0 D8126=1 D8126=2 version Main version 26232 or higher…
  • Page 42
    COOLMAY EX3G PLC/HMI All in one Programming manual Data length 0:7 bit 1:8 bit Parity 00:None 01:Odd 11:Even Stop bit 0:1 bit 1:2 bit Baud rate (b7b6b5b4) 0100:600bps 0101:1200bps 0110:2400bps 0111:4800bps 1000:9600bps 1001:19200bps 1010:38400bps 1011:57600bps 1100:115200bps Demo Program: Use the serial port tool by serial port 2 to monitor the data obtained: [2017:11:01:10:49:16][receive]31 32 33 2.11.1.3 Modbus RTU Protocol…
  • Page 43
    1011:57600bps 1100:115200bps Set 0 Set 0 Set 1 Set 1 Set 1 Read slave data instruction function and action description: RD3A originally referred to the analog module readout. For CoolMay PLC, the RD3A instruction corresponds to Modbus’s No. 03 function.
  • Page 44
    COOLMAY EX3G PLC/HMI All in one Programming manual In the instruction, m1 represents the station number of the read slave device,range:1-247; m2 represents the first address number of the read data in the slave device; D represents the number of registers read, range: 1-32, and the read data is sequentially stored in the host D.+1, D.+2.
  • Page 45
    COOLMAY EX3G PLC/HMI All in one Programming manual WR3A originally referred to the analog modules write. For CoolMay PLC, the WR3A instruction corresponds to Modbus’s 06 and 10 functions. In the instruction, m1 represents the station number of the slave device to be written, range :1-247.
  • Page 46
    COOLMAY EX3G PLC/HMI All in one Programming manual Program explanation: This program represents that 1 data of the register D301 in the master PLC is written to the PLC in Slave 1, and is stored in the register D100 of the slave PLC.
  • Page 47: Serial Port 3:Rs485 (A1 B1)/Rs232

    COOLMAY EX3G PLC/HMI All in one Programming manual Slave program: Use the serial port tool to monitor serial port 2 for below data: [2017:11:01:17:48:54][receive]01 03 00 00 00 06 C5 C8 [2017:11:01:17:48:54][receive]01 03 0C 00 0C 00 17 00 22 00 38 00 4E 00 63 C4 29 2.11.2 Serial port 3:RS485 (A1 B1)/RS232…

  • Page 48
    COOLMAY EX3G PLC/HMI All in one Programming manual M8196=1 RS port protocol M8192=1 M8125=0 RS sending mark M8122=1 M8402=1 M8422=1 Need manual reset RS sending completion mark M8425 Need manual reset RS receiving completion mark M8123 M8403 M8423 Need manual reset…
  • Page 49
    COOLMAY EX3G PLC/HMI All in one Programming manual M8029:Communication completion flag (communication completion flag when using ADPRW instruction, needs to be reset by hand). M8161:8-bit/16-bit mode distinguishing flag for RS/RS2 instruction (used in version 26230 and above, always in 8-bit mode in versions 26210 and 26220) D8400:Save the communication parameters of the Modbus RTU protocol…
  • Page 50
    COOLMAY EX3G PLC/HMI All in one Programming manual D8401 Parameter set Select protocol 0: Other communication protocol 1: MODBUS protocol b1~b3 Unavailable, Set 0 Master/Slave setting 0: MODBUS Master 1: MODBUS Slave b5~b15 Unavailable, Set 0 2.11.2.1 Mitsubishi programming protocol When using as mitsubishi programming port protocol: set M8192=0.
  • Page 51
    Read slave data instruction function and action description: RD3A originally referred to the analog module readout. For CoolMay PLC, the RD3A instruction corresponds to Modbus’s No. 03 function. In the instruction, m1 represents the station number of the read slave device,range:1-247;…
  • Page 52
    Write data to the slave instruction function and action description: WR3A originally referred to the analog modules write. For CoolMay PLC, the WR3A instruction corresponds to Modbus’s 06 and 10 functions. In the instruction, m1 represents the station number of the slave device to be written, range :1-247.
  • Page 53
    COOLMAY EX3G PLC/HMI All in one Programming manual Use the serial port tool to monitor serial port 3 for below data: [2017:11:01:09:25:20][receive]01 10 00 64 00 08 10 00 0B 00 16 00 21 00 2C 00 37 00 42 00 4D 00 58 D1 6C [2017:11:01:09:25:20][receive]01 10 00 64 00 08 10 00 0B 00 16 00 21 00 2C 00 37 00 42 00 4D 00 58 D1 6C 2.11.2.4 MODBUS RTU ADPRW Command…
  • Page 54: Modbus Communication Address Number

    COOLMAY EX3G PLC/HMI All in one Programming manual Use the serial port tool to monitor serial port 3 for below data: [2017:11:01:17:38:34][receive]01 04 00 00 00 06 70 08 [2017:11:01:17:38:34][receive]01 04 0C 00 15 00 20 00 2B 00 41 00 57 00 00 5F A7 2.11.3 Modbus Communication address number…

  • Page 55
    COOLMAY EX3G PLC/HMI All in one Programming manual 0x7F00~0xA13F 0x7F00~0xA13F Unused address 0xA140~0xA27F 0xA140~0xA27F TN0~TN319 0xA280~0xA33F 0xA280~0xA33F Unused address 0xA340~0xA407 0xA340~0xA407 CN0~CN199 0xA408~0xA477 0xA408~0xA477 CN200~CN255 0xA478~0xA657 0xA478~0xA657 M0~M7679 0xA658~0xA677 0xA658~0xA677 M8000~M8511 0xA678~0xA777 0xA678~0xA777 S0~S4095 0xA778~0xA78B 0xA778~0xA78B TS0~TS319 0xA78C~0xA797 0xA78C~0xA797 Unused address 0xA798~0xA7A7…
  • Page 56
    COOLMAY EX3G PLC/HMI All in one Programming manual Serial port Serial port Functions CAN(H/L) Remark 2(A/B) 3(A1/B1) 26232 or higher version: power Programming port M8196=0 M8192=0 lost can not be retentive M8196=1 RS2 functions M8192=1 M8125=0 RS2 sending mark M8122=1…
  • Page 57
    COOLMAY EX3G PLC/HMI All in one Programming manual M8424: Data is under receiving. M8425: The transmission is completed and needs manual reset. M8426: Switch between multi-machine mode and master-slave mode M8426=1: CAN is in multi-machine mode, there is no master-slave division, and it can transmit up to 8 bytes of data.
  • Page 58: Network Communication

    16-bit S0~S15 of the slave PLC to the M100~M115 of the master PLC. The default state is compatible with Mitsubishi original programs. The Mitsubishi PLC only has one port to support the ADPRW instruction, depends on D8401 (in prior) and D8421. All three ports of Coolmay PLC support the ADPRW instruction.

  • Page 59
    COOLMAY EX3G PLC/HMI All in one Programming manual the above parameters and then restart). M8062:=1 Represents MODBUS timeout, MODBUS_TCP is used. M8063:=1 Represents IP address is conflict. D8395:Switch between Mitsubishi function and MODBUS_TCP D8395=0:Mitsubishi function D8395=1:MODBUS_UPD Slave D8395=2:MODBUS_UPD Master D8395=3:MODBUS_TCP Slave D8395=4:MODBUS_TCP Master…
  • Page 60: Difference Between Ex3G And Ex2N Plc/Hmi All In One

    COOLMAY EX3G PLC/HMI All in one Programming manual 2.13 Difference between EX3G and EX2N PLC/HMI All in one Series EX2N series HMI/PLC all in one EX3G series HMI/PLC all in one Difference Size difference EX2N-43H series is the same as the EX3G-43HB series ,Dimension:134*102*30mm,Cutout:…

  • Page 61
    COOLMAY EX3G PLC/HMI All in one Programming manual The optional communication port supports the Optional communication port supports the Mitsubishi programming port Mitsubishi programming port protocol/MODBUS protocol/MODBUS protocol/RS protocol. protocol/RS protocol. EX2N-43H/43KH/50KH EX3G-43HB/43(50)KH can be equipped with Optional 1 RS232, optional audio, no optional 1 RS232.
  • Page 62
    COOLMAY EX3G PLC/HMI All in one Programming manual [M0~M383] 384 points General; [M0~M499] 500 points General; Auxiliary [M384~M1535] 1152 points to keep in; [M500~M1535] 1036 points Keep in; register range [M1536~M7679] 6144 points General; [M8000~M8255] 256 points Special. [M8000~M8511] 512 points Special.
  • Page 63
    COOLMAY EX3G PLC/HMI All in one Programming manual mixed output MRT. Support multiple channels of various types of analog single or mixed input and output, a single device up to 16 in 8 out, analog input and output accuracy 12 bits. The CX3G…
  • Page 64: Hmi

    3.1 HMI program software user introduction 3.1.1HMI Program software installation Coolmay HMI program software, compatible with XP/WIN7/WIN8/WIN10 system. If it can not be installed for use, pls try by replacing another computer, re-installing the system, and higher user rights. Among them, The WIN7 system must change the user account control settings to never notify, WIN8 system, WIN10 system must turn off the digital signature to reduce trouble.

  • Page 65: Hmi Display Download

    COOLMAY EX3G PLC/HMI All in one Programming manual EX3G-50KH/50KHA/70KHAS select MT6070H(800*480); EX3G-70KHA/100HA select MT6100HA(1024*600); 3.2 HMI Display download 3.2.1 Online download step (USB download line download) 1. After saving the program, click “application” — ”compile” in the software (shortcut F5)

  • Page 66
    COOLMAY EX3G PLC/HMI All in one Programming manual After compiling, it will prompt to create the target file successfully; 2. Under the target file path (view the default disk in the software application—target file path, the default is on the C drive) Confirm that the C drive has generated a file with the same file name and the same name as .hw6, as shown…
  • Page 67
    COOLMAY EX3G PLC/HMI All in one Programming manual 3. Click “Application”—”Download”. 4.The download window pops up, the HMI connection is OK, the IP setting is OK, wait for the download command prompt, and then click download; 5.The download will complete and the update will be successful.
  • Page 68: U Disk Download Step (43Hb Series Don’t Support)

    COOLMAY EX3G PLC/HMI All in one Programming manual 3.2.2 U disk download step (43HB series don’t support) 1. After saving the program, compile the program (shortcut F5); 2. Under the target file path (view the default disk in the software application—target file path, the default is on the C drive) Find the file generated in C disk, which name is “.hw6”…

  • Page 69: Introduction When Hmi Is With Com Port For Modbus Rtu Protocol

    COOLMAY EX3G PLC/HMI All in one Programming manual 5. Click “Update *.hw6 file”, enter the corresponding level password , the default super password is 12345678, the default normal password is empty (direct confirmation); if you changed the password, you need to enter the corresponding correct password;…

  • Page 70
    COOLMAY EX3G PLC/HMI All in one Programming manual 2) Communication Parameter setting: Open «Application — Setting OP — Network Settings» Controller ID Address Mode: Select the default standard mode 2.HMI as mater and connect to multi-slaves setting: Note: When the HMI is used as the Master with multiple slaves, the communication port must be set to COM2 in the Link1 setting (HMI optional RS485).
  • Page 71: Hmi As Slave

    COOLMAY EX3G PLC/HMI All in one Programming manual Extended communication ID switching interval: The default is 35ms, which can be adjusted according to actual communication. Extended Mode Start ID: The default is 1, which is the first slave station number of the connected slave.

  • Page 72: Other Hmi Usage

    COOLMAY EX3G PLC/HMI All in one Programming manual 2. station number setting 1) Put a function key on the HMI program and jump to the 255 system menu page, and then compile and download the program to the HMI. As shown below: 3.4 Other HMI usage.

Программируемый логический контроллер Cool may MX3G

Программируемый логический контроллер (ПЛК) MX3G

Благодарим вас за приобретение ПЛК Coolmay серии MX3G. В этом руководстве в основном объясняются функции продукта, технические характеристики и способы подключения. Подробное программирование см. в «Руководстве по программированию ПЛК Coolmay MX3G». Дополнительные спецификации могут быть настроены партиями.

ПЛК MX3G имеет следующие особенности:

  1. Высокая степень интеграции. Цифровое количество не более 16Dll6DO, цифровой выход может выбрать транзисторный выход или смешанный выход; Аналог MX3G-32M фиксируется на 2 канала 0-0V vol.tagе ввод.
  2. Поставляется с двумя портами программирования ПЛК: USB-порт Mini B (более высокая скорость загрузки и чтения) и RS232 (гнездо для головки мыши с 8 отверстиями);
    Как правило, 2 порта RS485 или массовая настройка их как 232 порт связи RS1+485 RSXNUMX.
  3. Поддержка нескольких высокоскоростных подсчетов и высокоскоростных импульсов. Высокоскоростной подсчет, как правило, 2 канала, одна фаза 60 кГц + 4 канала, 0 кГц или 30 канал AB (Z), фаза 00 кГц + 0 канал, AB (Z), фаза SKHz; Высокоскоростные импульсы обычно составляют 0 кГц для Y2~Y3 и SXNUMX кГц для YXNUMX~YXNUMX с независимым ускорением и замедлением.
    Общая частота высокоскоростного счета + высокоскоростной импульс не может превышать 300 кГц.
  4. Специальное шифрование, установка пароля 12345678 может полностью предотвратить чтение программы. [Примечание: поддерживается только 8-битное шифрование пароля]
  5. Используйте вставные клеммы с шагом 5.0 мм для упрощения подключения; Для установки можно использовать DIN-рейку (шириной 35 мм) и фиксированные отверстия.
  6. Суперфункция. Совместимость с ПЛК FX3S, высокая скорость работы.

информация о продукте

  1. Серии     MX3G: ПЛК MX3G
  2. Цифровой вход и выход (DI/DO) 16: (8Dl/8DO) 32: (16Dl/16DO)
  3. Тип модуля  M: Основной модуль универсального контроллера
  4. Цифровой выход (DO) типа R: Релейный; Т: транзистор; RT: Транзисторно-релейный смешанный выход
  5. Аналоговый вход (AD)  MX3G-32M: 2АД; MX3G-16M не имеет аналога
  6. Аналоговый выход (DA) MX3G-32M: вход 0-lOV для 2AD
  7. Кл: Однофазный высокоскоростной счет, C2: счет фаз AB, C3: счет фаз ABZ. Как правило, 2 однофазных 60 кГц + 4 0 кГц или 1 фаза AB (Z) 30 кГц + 1 фаза AB (Z) 5 кГц.
  8. ПО: высокоскоростной импульс 00кГц; Pl: высокоскоростной импульс l00 кГц. Как правило, YO-Y2 составляет 3 кГц для каждого канала, а YXNUMX-YXNUMX составляет XNUMX кГц для каждого канала.
    Общая частота высокоскоростного счета + высокоскоростной импульс не может превышать 300 кГц.
  9. Дополнительный COM-порт   См. [Таблица 1: основной параметр]
Основной параметр
MX3G ПЛК Цифровые точки Аналоговые точки (опционально) COM-порт Высокоскоростной счет High
скорость
импульс
Размер
DI DO AD DA 485/232 Отдельная фаза Фаза АВ фаза АБЗ Результат Размеры (мм) Размер выреза (мм)
М Х3Г-16М  

8

 

8

 

0

 

0

По умолчанию 2РС48С;
Или можно настроить

л RS485,1 RS232

Ge11€ралли однофазный 260KHz+4 канала 0KHz; Обычно фаза AB канал 30КХ>+XNUMX канал СКГц; Обычно фаза ABZ 1 канал 30KHz•1 канал SKHz; Обычно 4 канала; YO-Ylis I OOKH>, Y2-Y3is СОГц; Высокоскоростной считая+ высокоскоростной импульс не может превышать 300 кГц 65″90’66 57 ″ 99
МХ3Г-32М 16 16 2 0 130 • 90 • 66 122’99
МТ — транзисторный выход: Y0-Y3 закреплены как транзисторы; MR – релейный выход; MRT выпускаются смешанные, опционально в соответствии с требованиями заказчика.

Диаграмма 1: Электрические параметры

Электрический параметр
Входная громкостьtage   AC 220V
Индексы цифровых входов
Режим изоляции   Фото муфта
Входное сопротивление   Скоростной ввод 3.4KO I Общий ввод 4.3KO
Вход включен Высокоскоростной вход: ток > 5.8 мА/24 В I Общий вход: ток > 9.9 мА/24 В
Вход ВЫКЛ. Высокоскоростной вход: ток <4.Sm/A19В I Общий вход: ток>4мА/17В
Функция фильтра С функцией фильтра время фильтрации может быть установлено в пределах 0-60 мс, по умолчанию 0 мс.
Высокоскоростной счет Обычно 2 однофазных 60 кГц + 4 кГц или 0 фаза AB (Z) 1 кГц + фаза 30 AB (Z) SKHz
Входной уровень Пассивный NPN, общая изоляция клемм, S/S подключен к 24 В+
Индекс цифрового релейного выхода
Макс. Ток 2A/точка, 4A/4точка COM, 5A/8точка COM, 5A/12точка COM
Мощность цепи об.tage DC/AC24В~220В
Изоляция цепи Реле механическое Калибровка изоляции
О времени отклика прибл. 0 мс
Механическая долговечность (без нагрузки) 10 миллионов раз
Электрическая долговечность (номинальная нагрузка) 300,000 раз
уровень выходного сигнала Нормально разомкнутый выход с сухим контактом, COM можно подключить к положительному или отрицательному
Индекс цифрового транзисторного выхода
Макс. Ток Y0-Y3 фиксируется как МТ, 0 А/точка; MT: 0.SA/точка, 0.SA/4точка COM, l. 6A/8 точек COM;
Мощность цепи об.tage 24В
Изоляция цепи Изоляция оптопары
Изолированный томtagе (силовой треминал) л S00VAC
О времени отклика Высокоскоростной выход: 0 мкс; другой 0.Sms
Высокоскоростная выходная частота Обычно 4 канала, Y0-Yl — 0 кГц, Y2-Y3 — S0 кГц.

Высокоскоростной счет + высокоскоростной импульс не может превышать 300 кГц

уровень выходного сигнала Y0-Y3isDC24Vактивный выход NPN, другие, как правило, низкоуровневые l PN, COM отрицательный
Индекс аналогового входа
входной сигнал 0-0В
Время реакции 1 цикл сканирования
Индексы аналогового выхода 2 каналов
Точность 12 биты
Внешний порт
Порт программирования USB-порт Mini B (более высокая скорость загрузки) и RS232 (гнездо для мыши с 8 отверстиями)
COM-порт См. «Таблица 1: основной параметр».
  Окружающая среда
Рабочая Температура 0°С~50°С
Относительная влажность 5% ∼ 950‰RH
Температура хранения -20°С-70°С
частота колебаний 10-57Hz, ampвысота 0.035 мм; 57 Гц-150 Гц, ускорение 4.9 м/с2 (Прямые ионы X, Y и Z по 10 раз, всего 80 минут каждый)

Механический дизайн


Электрический дизайн

  1. Монтажные отверстия
  2. Клеммная колодка источника питания
  3. Клеммная колодка цифрового выхода
  4. Светодиодный дисплей цифрового входа
  5. Светодиодный дисплей цифрового выхода
  6. PWR: индикатор питания RUN: индикатор работы ПЛК ERR: загорается при возникновении ошибки программы
  7. RS485 / RS232 / CAN
  8. RS485
  9. Переключатель работы ПЛК RUN/STOP
  10. Аналоговый вход
  11. Аналоговый вывод
  12. RS232
  13. Слот для установки на DIN-рейку (ширина 35 мм)
  14. Клеммная колодка цифрового входа
  15. USB-порт для программирования ПЛК

Аппаратный интерфейс

ОВ 24В С/С XOO- X07
Y24V YOO~Y03 КОМО Y04~Y07
MX3G-16MT/МРТ
OV 24V S/S XOO~X17 GNDl ADO GNDl ADl Y24V YOO~Y03 COMO Y04~Y07 COMl YlO~Yl3 COM2 Yl4 ~Y17 MX3G-32MT/ MRT-2AD

Определение контактов ПЛК MX3G

Номер контакта сигнал Описание
4 RXD Получить данные
5 TXD Передача данных
8 GND земля


График 4 Порт программирования ПЛК
Стандарт проводки клемм: провод 22-14AWG. Клеммы этой серии являются съемными клеммами.

Определение COM-интерфейса:
Поставляется с двумя портами для программирования: USB-порт Mini B-типа (более высокая скорость загрузки) и RS232 (гнездо для мыши с 8 отверстиями). По умолчанию 2 RS485 или могут быть настроены как 1 RS485, 1 RS232.

Описание COM-порта:

  • Последовательный порт 1: RS232 (порт программирования ПЛК): поддерживает протокол порта программирования Mitsubishi, который можно использовать для загрузки программ ПЛК или связи с устройствами, поддерживающими протокол порта программирования Mitsubishi.
  • Последовательный порт 2: RS485 (порт AB)/дополнительно RS232: поддержка протокола порта программирования Mitsubishi, протокола RS и протокола Modbus RTU/ASCII
    * Поддержка инструкций RS, WR3A, RD3A, ADPRW
  • Последовательный порт 3: RS485 (порт Al, Bl): поддержка протокола порта программирования Mitsubishi, протокола RS2 и протокола Modbus RTU/ASCII, c Поддержка инструкций RS2, WR3A, RD3A, ADPRW
    Внимание: Подробные настройки см. в «Руководстве по программированию ПЛК Coolmay MX3G».

Эквивалентная схема

Проводка цифрового входа

Вход ПЛК (X) представляет собой внешний источник питания DC24V стокового типа (пассивный NPN), а входной сигнал изолирован от источника питания. При использовании вам необходимо подключить 5/5 к плюсу 24 В источника питания.

Проводка цифрового входа ПЛК:
Короткое соединение порта: S / S входной клеммы ПЛК подключен к 24 В, а клемма X подключена к источнику питания OV, то есть на входе есть сигнал;
Двухпроводная система (магнитный переключатель): цифровой вход ПЛК подключен к двухпроводному магнитному переключателю, положительный полюс магнитного переключателя подключен к клемме X, а отрицательный полюс подключен к OV; Трехпроводная система (фотоэлектрический датчик или энкодер): переключатель ПЛК подключен к трехпроводному фотоэлектрическому датчику или энкодеру, источник питания датчика или энкодера подключен к положительному полюсу источника питания, а сигнальный кабель подключен к Ксенду. Энкодеры и фотоэлектрические датчики должны быть типа NPN (для PNP требуется специальная настройка).

Проводка цифрового выхода ПЛК:
Транзистор: YO-Y3 фиксируются как импульсные выходные порты, нагрузка проводки составляет всего 24 А, а метод проводки — активный выход NPN XNUMX В постоянного тока;
Другой общий выход — NPN, COM подключен к отрицательному полюсу, а Y подключен к положительному полюсу источника питания после нагрузки. Реле: выход с сухим контактом, COM можно подключить к плюсу или минусу.

Проводка цифрового выхода

На рис. 7 показана эквивалентная принципиальная схема модуля релейных выходов. Выходные клеммы объединены в несколько групп, каждая группа электрически изолирована, а выходные контакты разных групп подключены к разным силовым цепям.

Эквивалентная схема выходной части ПЛК транзисторного выхода показана на рисунке 8. Из рисунка также видно, что выходные клеммы находятся в нескольких группах, и каждая группа электрически изолирована. Выходы разных групп могут быть подключены к разным силовым цепям; транзисторный выход можно использовать только для цепей нагрузки 24 В постоянного тока. Режим выходной проводки: общий катод NPN, COM.
Среди них YO-Y3 фиксируются как импульсные выходные порты, нагрузка проводки составляет всего 24 А, а метод проводки — активный выход NPN постоянного тока XNUMX В.

Для индуктивной нагрузки, подключенной к петле переменного тока, внешняя цепь должна учитывать мгновенную нагрузку RC.tagсхема поглощения; для нагрузки контура постоянного тока рассмотрите возможность добавления обратного диода, как показано на рис. 9.

Схема подключения шагового двигателя или серводвигателя показана на рис. 10. ПЛК серии MX3G по умолчанию использует YO-Y3 в качестве точек импульса, направление можно настроить. Как показано на рисунке 10.
Внимание: привод 5 В должен подключить резистор 2 кОм последовательно с 24 В постоянного тока.

* Внимание: Все внутренние схемы на схемах приведены только для справки.

Аналоговая проводка

Аналоговая проводка ПЛК

Двухпроводная система: положительный полюс источника питания подключен к положительному полюсу передатчика, отрицательный полюс передатчика подключен к порту AD, а отрицательный полюс источника питания подключен к порту GND. Как правило, это метод подключения преобразователя 0~20 мН4~20 мА; Трехпроводная система: положительный полюс источника питания подключен к положительному полюсу передатчика, отрицательный полюс источника питания и отрицательный полюс выходного сигнала являются одной и той же клеммой, а выходной сигнал передатчика подключен к порту AD; Четырехпроводная система: положительный и отрицательный полюсы источника питания подключены к положительному и отрицательному полюсам передатчика соответственно, а положительные и отрицательные полюса выхода сигнала передатчика подключены к порту AD и GND соответственно.

Противоинтерференционная обработка ПЛК

  1. Сильные и слабые токи следует разделять и соединять, а не заземлять; при наличии сильных электрических помех следует добавить магнитные кольца со стороны источника питания; и должным образом и эффективно заземлены в соответствии с типом шасси.
  2. Когда аналоговая величина нарушена, можно добавить 104 керамических конденсатора для фильтрации и выполнить правильное и эффективное заземление.
    *Внимание: Для получения более подробной информации см. «Метод обработки PLC Anti-Interference Processing» на официальном сайте Coolmay. webсайт

Справочник по программированию

Распределение устройств и заявление о сохранении питания

Максимальное количество цифровых баллов MX3G1-6M МХ3Г-32М
Цифровой вход Х X00 ∼ X078пони т XOO∼ Xl7 16 баллов
Цифровой выход Y Y00 ∼ Y 07 8 точек Y00 ∼ Yl7 16 точек
Вспомогательное реле M [MO-M383] 384 точки GeneralV [M384-M511] 128 точек Retentive/ [MS12-ML535] 6144 точек General
fM8000-M81511 512oint Снедаль
Штаты S [SO-S9]10pointInitial slate/[SIO-S127]118point Retentive/[S128-525]5128pointGeneral
Таймер Т [TO-HI] 32 точки OOmsGenrael / [ [T32-T62] 31 точка 100 мс, M802=80N omeslOms
[Tl28-Tl3]14 точек ламы слепой кишки позднее задержание /[Tl32-Tl37] 6pointl 00 msaccumulaivtereteniotn
Счетчик С 16-битный прямой счетчик[CO-CIS)16точечный общий/iC16-0 l 16точечный сохраняющий
32b- счетчик вверх/вниз(C200-C234]35pointGeneral
Высокоскоростные счетчики[C235-C245Snigle Phase silage count] [C246-C250SSSinglephasedouble count]

{Двухфазный двойной счет C251-C525]

Данные зарегистрированы [OO-D127] [D256-02999] 2872 пункта Общий/[ D128·0255] [D1000-D3999] 3128 пунктов Сохраняемый

/[D8000-08511]Особый 512 баллов

Регистр данных V, Z [VO-V7] [ZO-Z7] 16-точечный индекс
Указатель JUMP, филиал ЦАИ.Л [PO-P255] 256 точек / [PO~ Pl280] 1281 точка (версия 26232 или выше)
Вложенный указатель INO-N7]8point Мастер управления
перебой [10::JO~ ISOO ] 6-точечное прерывание ввода/ [160 0 ~ 180 0 ] 3-точечное прерывание таймера
постоянная K 16 бит-3,2768-32,767 32 бита -2,147,483,648 2,147,48,3647 XNUMX XNUMX-XNUMX XNUMX XNUMX XNUMX
H 16 бит 0-FFFFH 32 бита 0-FFFFFFFFH

Обслуживание устройств ПЛК MX3G при отключении питания поддерживается постоянно, т. е. все устройства в зоне ожидания не теряются после отключения питания модуля. Часы реального времени используют перезаряжаемую батарею, чтобы часы отображали текущее время. Все функции удержания при отключении питания должны обеспечиватьtagЭлектропитание источника постоянного тока 24 В превышает 23 В с нагрузкой, а время включения ПК превышает 2 минуты, в противном случае функция отключения питания будет ненормальной.

Программное обеспечение для программирования, совместимое с программным обеспечением для программирования GX Developer 8.86Q и GX Works2 Подробную информацию см. в: «Руководство по программированию ПЛК Coolmay MX3G», «Руководство пользователя программируемого логического контроллера (ПЛК) MX3G», «Руководство по программированию ПЛК Cool may».

Программируемый логический контроллер (ПЛК) MX3G. Руководство пользователя.
– Перед использованием данного продукта прочтите соответствующее руководство. Осторожно используйте продукт в условиях окружающей среды, указанных в руководстве.

  1. Пожалуйста, подтвердите объем источника питанияtagдиапазон этого продукта (обычный источник питания продукта AC220V!) и исправьте проводку перед включением питания, чтобы избежать повреждения.
  2. При установке этого продукта обязательно затяните винты или скобы.amp направляющие, чтобы не упасть.
  3. Пожалуйста, не подсоединяйте, не подключайте и не отключайте штекер кабеля при включенном питании, в противном случае можно легко вызвать поражение электрическим током или повреждение цепи. Немедленно выключите питание, если продукт издает специфический запах или необычный звук. Не бросайте металлическую стружку и концы проводов в вентиляционные отверстия контроллера во время обработки отверстий под винты и проводки; в противном случае это может привести к сбою продукта и неправильной работе.
  4. Не связывайте шнур питания и кабель связи вместе и не кладите их слишком близко друг к другу, держите их на расстоянии более 10 см; сильные и слабые токи должны быть разделены и должным образом и эффективно заземлены. В ситуациях с сильными помехами следует использовать экранированные кабели для связи, а также кабели ввода и вывода высокочастотных сигналов для улучшения защиты от помех. Клемма заземления FG на машине должна быть правильно заземлена, чтобы улучшить помехоустойчивость.
  5. Вход переключателя представляет собой внешний источник питания постоянного тока 24 В стокового типа (пассивный NPN), а входной сигнал изолирован от источника питания. При использовании S/S должен быть подключен к плюсу 24 В внешнего источника питания.
  6. Активно выводится Y24V общей клеммы цифрового выхода.
  7. Пожалуйста, не разбирайте изделие и не изменяйте проводку по своему усмотрению. В противном случае это может привести к поломке, неправильной работе, потере или возгоранию.
  8. Пожалуйста, отключите все питание при установке и разборке продукта, в противном случае это приведет к сбоям в работе оборудования и ошибкам.

Поддержка клиентов

Шэньчжэнь Coolmay Technology Co., Ltd.
Тел: 0755-86950416
86960332
26051858
26400661
Факс: 0755-26400661-808
QQ: 1687435500
Эл. почта: m3@coolmay.com
Веб-сайт: www.coolmayplc.com

Документы / Ресурсы

  • Introduction
  • Culture
  • History
  • Honor


Shenzhen Coolmay Technology Co., Ltd,the developer 


Coolmay HMI/PLC ALL-IN-ONE series, the original an

  • Power supply Module L02-60P

    Input: 100-240VAC, 50/60Hz AC power input.
    Output (for L02 series products): 24VDC/1.5A, 36W
    Output (for other products): 24VDC/0.5A, 12W

  • Digital input Module L02-8EX

    DC24V, 6mA, 8 points input, push-type terminal

  • Digital input Module L02-16EX

    DC24V, 6mA, 16 points input, push-type terminal

  • Digital input Module L02-32EX

    DC24V, 6mA, 32 points input, horn block terminal

  • Digital output Module L02-8EYT

    30VDC, 2A/point; 2A/4point COM, 8 points transistor output, push-type terminal

  • Digital output Module L02-8EYR

    Below AC220V / Below DC30V, 2A/point, 4A/4point COM, 8 points relay output,
    push-type terminal

  • Digital output Module L02-16EYT

    30VDC, 2A/point; 2A/4point COM, 16 points transistor output, push-type terminal

  • Digital output Module L02-16EYR

    Below AC220V / Below DC30V, 2A/point, 4A/4point COM, 16 points relay output,
    push-type terminal

  • Digital output Module L02-32EYT

    30VDC, 2A/point; 2A/4point COM, 32 points transistor output, horn block terminal

  • Digital input output mixed Module L02-16ET

    DC24V, 6mA, 8 points input;
    30VDC, 2A/point; 2A/4point COM, 8 points transistor output, push-type terminal

  • Digital input output mixed Module L02-16ER

    DC24V, 6mA, 8 points input;
    Below AC220V / Below DC30V, 2A/point, 4A/4point COM, 8 points relay output,
    push-type terminal

  • Digital input output mixed Module L02-32ET

    DC24V, 6mA, 16 points input;
    30VDC, 2A/point; 2A/4point COM, 16 points transistor output, horn block terminal

  • Analog output Module L02-4DA

    4-channel analog signal output
    16-bit resolution 0~5V, 0~10V, 0~20mA

  • Analog input Module L02-4AD

    Channel analog signal input
    16-bit resolution 0~10V, 0~5V, 0~20mA, -20~20mA

  • Analog input output mixed Module L02-4AD2DA

    4-channel analog signal input; 16-bit resolution 0~10V, 0~5V, 4~20mA, 0~20mA
    2-channel analog signal output; 16-bit resolution 0~5V, 0~10V, 0~20mA

  • Temperature Module L02-4RTD

    4-channel 2-wire or 3-wire RTD temperature sensing
    Sensor type: Pt100/Pt1000; Resolution: 0.1℃/0.1℉(16 bit converter)

  • Temperature Module L02-4TC

    4-channel thermocouple temperature sensing
    Sensor type: J, K, S, T, E; Resolution: 0.1℃/0.1℉ (16 bit converter)

  • Temperature Module L02-4NTC

    4-channel thermistor temperature sensing
    Sensor type: NTC10K; Resolution: 0.1℃/0.1℉ (16 bit converter)

  • Weighing/Load cell Module L02-2LC

    2-channel 4-wire load cell
    Characteristic values: 1, 2, 4, 6, 20, 40, 80 mV/V
    Accuracy error value: one ten thousandth (1/10000)
    ADC resolution: 23 bits

  • Ethernet/IP Module L02-EIP

    Built-in two Ethernet interfaces, support switch function
    Support Ethernet/IP protocol, remotely expand I/O available.

Понравилась статья? Поделить с друзьями:
  • Cool maker go glam инструкция
  • Cool equipment льдогенератор инструкция по применению на русском
  • Cool equipment витрина настольная инструкция
  • Cooky stuff инструкция по применению
  • Cooking lunch box инструкция по применению