Manuals and User Guides for Daikin VRV II Series. We have 3 Daikin VRV II Series manuals available for free PDF download: Design, Installation & Testing Instructions, Introduction Manual, Technical Data Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Related Manuals for Daikin VRV II RXYQ5MATL

Summary of Contents for Daikin VRV II RXYQ5MATL

  • Page 1
    Si39 — 504 RXYQ5-48MAYL(E), TL(E) R-410A Heat Pump 60Hz…
  • Page 2: Table Of Contents

    Si39-504 R-410A Heat Pump 60Hz 1. Introduction ……………….. vi 1.1 Safety Cautions ………………vi 1.2 PREFACE ………………..x Part 1 General Information …………1 1. Model Names of Indoor/Outdoor Units…………2 2. External Appearance…………….3 2.1 Indoor Units ………………..3 2.2 Outdoor Units ……………….4 3.

  • Page 3
    Si39-504 Pump-down Residual Operation …………81 3.5 Standby ………………..82 Stopping Operation …………….83 Pressure Equalization prior to Startup…………85 Protection Control ……………..86 High Pressure Protection Control…………86 Low Pressure Protection Control…………87 Discharge Pipe Protection Control …………88 Inverter Protection Control …………..89 STD Compressor Overload Protection………..90 4.6 Injection Control (only for RXYQ5MA)…………90 Other Control………………91 Outdoor Unit Rotation…………….91…
  • Page 4
    Si39-504 3.5 “A7” Indoor Unit: Malfunction of Swing Flap Motor (MA) …….175 3.6 “A9” Indoor Unit: Malfunction of Moving Part of Electronic Expansion Valve (20E) …………177 3.7 “AF” Indoor Unit: Drain Level above Limit……….179 3.8 “AJ” Indoor Unit: Malfunction of Capacity Determination Device ..180 3.9 “C4”…
  • Page 5
    Si39-504 3.44 “U5” Indoor Unit: Malfunction of Transmission Between Remote Controller and Indoor Unit…………221 3.45 “U7” Indoor Unit: Malfunction of Transmission Between Outdoor Units ………………222 3.46 “U8” Indoor Unit: Malfunction of Transmission Between Main and Sub Remote Controllers …………224 3.47 “U9” Indoor Unit: Malfunction of Transmission Between Indoor and Outdoor Units in the Same System……..225 3.48 “UA”…
  • Page 6
    Si39-504 5.1 Piping Installation Point …………….295 The Example of A Wrong Pattern…………296 6. Selection of Pipe Size, Joints and Header ……….297 Thermistor Resistance / Temperature Characteristics……299 Pressure Sensor ……………..301 Method of Replacing The Inverter’s Power Transistors and Diode Modules ………………302 Part 8 Precautions for New Refrigerant (R-410A) ….
  • Page 7: Introduction

    Introduction Si39-504 1. Introduction Safety Cautions Cautions and Be sure to read the following safety cautions before conducting repair work. The caution items are classified into “ Warning” and “ Caution”. The “ Warning” Warnings items are especially important since they can lead to death or serious injury if they are not followed closely.

  • Page 8
    Si39-504 Introduction Caution Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock. Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical shocks.
  • Page 9
    Introduction Si39-504 Warning Be sure to use the specified cable to connect between the indoor and outdoor units. Make the connections securely and route the cable properly so that there is no force pulling the cable at the connection terminals. Improper connections can cause excessive heat generation or fire.
  • Page 10
    Si39-504 Introduction Caution Check to see if the parts and wires are mounted and connected properly, and if the connections at the soldered or crimped terminals are secure. Improper installation and connections can cause excessive heat generation, fire or an electrical shock. If the installation platform or frame has corroded, replace it.
  • Page 11: Preface

    This is the new service manual for Daikin’s Year 2006 VRVII series Heat Pump System. Daikin offers a wide range of models to respond to building and office air conditioning needs. We are confident that customers will be able to find the models that best suit their needs.

  • Page 12: Part 1 General Information

    Si39-504 Part 1 General Information 1. Model Names of Indoor/Outdoor Units…………2 2. External Appearance…………….3 2.1 Indoor Units ………………..3 2.2 Outdoor Units ……………….4 3. Combination of Outdoor Units…………..5 4. Model Selection………………6 General Information…

  • Page 13: Model Names Of Indoor/Outdoor Units

    Model Names of Indoor/Outdoor Units Si39-504 1. Model Names of Indoor/Outdoor Units Indoor Units Type Model Name Power Supply Ceiling Mounted FXCQ — 125M — — Cassette Type (Double Flow) Ceiling Mounted FXFQ — 100M 125M — — Cassette Type (Multi Flow) Ceiling Mounted FXKQ…

  • Page 14: External Appearance

    Si39-504 External Appearance 2. External Appearance Indoor Units Ceiling Mounted Cassette Type (Double Flow) Ceiling Mounted Duct Type FXMQ40M FXCQ20M FXCQ25M FXMQ50M FXCQ32M FXMQ63M FXCQ40M FXMQ80M FXCQ50M FXMQ100M FXCQ63M FXMQ40~125M FXCQ80M FXMQ125M FXCQ125M FXMQ200M FXMQ250M FXMQ200 · 250M Ceiling Mounted Cassette Type (Multi Flow) Ceiling Suspended Type FXFQ25M FXHQ32M…

  • Page 15: Outdoor Units

    External Appearance Si39-504 Outdoor Units RXYQ5MA RXYQ8MA, 10MA RXYQ12MA, 14MA, 16MA 8,10HP 12,14,16HP RXYQ18MA, 20MA RXYQ22MA, 24MA, 26MA 18, 20HP 22, 24, 26HP RXYQ28MA, 30MA, 32MA RXYQ34MA, 36MA 28, 30, 32HP 34, 36HP RXYQ38MA, 40MA, 42MA RXYQ44MA, 46MA, 48MA 38, 40, 42HP 44, 46, 48HP General Information…

  • Page 16: Combination Of Outdoor Units

    Heat Pump: BHFP22MA90 26HP 28HP 30HP 32HP 34HP 36HP 38HP 40HP Heat Pump: BHFP22MA135 42HP 44HP 46HP 48HP Note: For multiple connection of 18HP system or more, an optional Daikin Outdoor Unit Multi Connection Piping Kit is required. General Information…

  • Page 17: Model Selection

    Model Selection Si39-504 4. Model Selection VRV II Heat Pump Series Connectable indoor units number and capacity 10HP 12HP 14HP 16HP System name RXYQ5MA RXYQ8MA RXYQ10MA RXYQ12MA RXYQ14MA RXYQ16MA Outdoor unit 1 RXYQ5MA RXYQ8MA RXYQ10MA RXYQ12MA RXYQ14MA RXYQ16MA Outdoor unit 2 –…

  • Page 18
    Si39-504 Model Selection Connectable Indoor Unit Type Model Name Power Supply Ceiling Mounted FXCQ — 125M — — Cassette Type (Double Flow) Ceiling Mounted FXFQ — 100M 125M — — Cassette Type (Multi Flow) Ceiling Mounted FXKQ — — — —…
  • Page 19
    Model Selection Si39-504 Differences from Conventional Models Differences Item Object New model (MA Model) Conventional model (M Model) NONE Compressor Connection of equalizer oil pipe (No particular changes in terms of service) Equalizer oil pipe for multi- NONE outdoor-unit system Refilling quantity due to piping Refilling quantity due to piping Workability…
  • Page 20: Part 2 Specifications

    Si39-504 Part 2 Specifications Specifications ………………10 Outdoor Units ………………10 Indoor Units ………………..21 Specifications…

  • Page 21: Specifications

    Specifications Si39-504 Specifications Outdoor Units RXYQ5MAYL(E) RXYQ8MAYL(E) Model Name RXYQ5MATL(E) RXYQ8MATL(E) kcal / h 12,100 21,800 1 Cooling Capacity (19.5°CWB) Btu / h 48,100 86,700 14.1 25.4 2 Cooling Capacity (19.0°CWB) 14.0 25.2 kcal / h 13,800 24,400 3 Heating Capacity Btu / h 54,600 97,000…

  • Page 22
    Si39-504 Specifications RXYQ10MAYL(E) RXYQ12MAYL(E) Model Name RXYQ10MATL(E) RXYQ12MATL(E) kcal / h 24,300 29,000 1 Cooling Capacity (19.5°CWB) Btu / h 96,200 115,000 28.2 33.7 2 Cooling Capacity (19.0°CWB) 28.0 33.5 kcal / h 27,000 32,300 3 Heating Capacity Btu / h 107,000 128,000 31.5…
  • Page 23
    Specifications Si39-504 RXYQ14MAYL(E) RXYQ16MAYL(E) Model Name RXYQ14MATL(E) RXYQ16MATL(E) kcal / h 34,600 39,000 1 Cooling Capacity (19.5°CWB) Btu / h 137,000 155,000 40.2 45.3 2 Cooling Capacity (19.0°CWB) 40.0 45.0 kcal / h 38,700 43,000 3 Heating Capacity Btu / h 154,000 171,000 45.0…
  • Page 24
    Si39-504 Specifications RXYQ18MAYL(E) RXYQ20MAYL(E) Model Name (Combination Unit) RXYQ18MATL(E) RXYQ20MATL(E) RXYQ8MAYL(E)+RXYQ10MAYL(E) RXYQ10MAYL(E)+RXYQ10MAYL(E) Model Name (Independent Unit) RXYQ8MATL(E)+RXYQ10MATL(E) RXYQ10MATL(E)+RXYQ10MATL(E) kcal / h 46,000 48,400 1 Cooling Capacity (19.5°CWB) Btu / h 183,000 192,000 53.5 56.3 2 Cooling Capacity (19.0°CWB) 53.2 56.0 kcal / h 51,500 54,200…
  • Page 25
    Specifications Si39-504 RXYQ22MAYL(E) RXYQ24MAYL(E) Model Name (Combination Unit) RXYQ22MATL(E) RXYQ24MATL(E) RXYQ10MAYL(E)+RXYQ12MAYL(E) RXYQ10MAYL(E)+RXYQ14MAYL(E) Model Name (Independent Unit) RXYQ10MATL(E)+RXYQ12MATL(E) RXYQ10MATL(E)+RXYQ14MATL(E) kcal / h 53,200 58,800 1 Cooling Capacity (19.5°CWB) Btu / h 211,000 233,000 61.9 68.4 2 Cooling Capacity (19.0°CWB) 61.5 68.0 kcal / h 59,300 65,800…
  • Page 26
    Si39-504 Specifications RXYQ26MAYL(E) RXYQ28MAYL(E) Model Name (Combination Unit) RXYQ26MATL(E) RXYQ28MATL(E) RXYQ10MAYL(E)+RXYQ16MAYL(E) RXYQ12MAYL(E)+RXYQ16MAYL(E) Model Name (Independent Unit) RXYQ10MATL(E)+RXYQ16MATL(E) RXYQ12MATL(E)+RXYQ16MATL(E) kcal / h 63,100 68,000 1 Cooling Capacity (19.5°CWB) Btu / h 250,000 270,000 73.4 79.0 2 Cooling Capacity (19.0°CWB) 73.0 78.5 kcal / h 70,000 75,300…
  • Page 27
    Specifications Si39-504 RXYQ30MAYL(E) RXYQ32MAYL(E) Model Name (Combination Unit) RXYQ30MATL(E) RXYQ32MATL(E) RXYQ14MAYL(E)+RXYQ16MAYL(E) RXYQ16MAYL(E)+RXYQ16MAYL(E) Model Name (Independent Unit) RXYQ14MATL(E)+RXYQ16MATL(E) RXYQ16MATL(E)+RXYQ16MATL(E) kcal / h 73,500 77,800 1 Cooling Capacity (19.5°CWB) Btu / h 292,000 309,000 85.5 90.5 2 Cooling Capacity (19.0°CWB) 85.0 90.0 kcal / h 81,700 86,000…
  • Page 28
    Si39-504 Specifications RXYQ34MAYL(E) RXYQ36MAYL(E) Model Name (Combination Unit) RXYQ34MATL(E) RXYQ36MATL(E) RXYQ10MAYL(E)+RXYQ10MAYL(E)+RXYQ14MAYL(E) RXYQ10MAYL(E)+RXYQ10MAYL(E)+RXYQ16MAYL(E) Model Name (Independent Unit) RXYQ10MATL(E)+RXYQ10MATL(E)+RXYQ14MATL(E) RXYQ10MATL(E)+RXYQ10MATL(E)+RXYQ16MATL(E) kcal / h 83,100 87,700 1 Cooling Capacity (19.5°CWB) Btu / h 330,000 348,000 96.6 2 Cooling Capacity (19.0°CWB) 96.0 kcal / h 92,900 97,200 3 Heating Capacity…
  • Page 29
    Specifications Si39-504 RXYQ38MAYL(E) RXYQ40MAYL(E) Model Name (Combination Unit) RXYQ38MATL(E) RXYQ40MATL(E) RXYQ10MAYL(E)+RXYQ12MAYL(E)+RXYQ16MAYL(E) RXYQ10MAYL(E)+RXYQ14MAYL(E)+RXYQ16MAYL(E) Model Name (Independent Unit) RXYQ10MATL(E)+RXYQ12MATL(E)+RXYQ16MATL(E) RXYQ10MATL(E)+RXYQ14MATL(E)+RXYQ16MATL(E) kcal / h 92,900 98,000 1 Cooling Capacity (19.5°CWB) Btu / h 368,000 389,000 2 Cooling Capacity (19.0°CWB) kcal / h 102,000 109,000 3 Heating Capacity Btu / h…
  • Page 30
    Si39-504 Specifications RXYQ42MAYL(E) RXYQ44MAYL(E) Model Name (Combination Unit) RXYQ42MATL(E) RXYQ44MATL(E) RXYQ10MAYL(E)+RXYQ16MAYL(E)+RXYQ16MAYL(E) RXYQ12MAYL(E)+RXYQ16MAYL(E)+RXYQ16MAYL(E) Model Name (Independent Unit) RXYQ10MATL(E)+RXYQ16MATL(E)+RXYQ16MATL(E) RXYQ12MATL(E)+RXYQ16MATL(E)+RXYQ16MATL(E) kcal / h 102,000 108,000 1 Cooling Capacity (19.5°CWB) Btu / h 406,000 427,000 2 Cooling Capacity (19.0°CWB) kcal / h 114,000 119,000 3 Heating Capacity Btu / h…
  • Page 31
    Specifications Si39-504 RXYQ46MAYL(E) RXYQ48MAYL(E) Model Name (Combination Unit) RXYQ46MATL(E) RXYQ48MATL(E) RXYQ14MAYL(E)+RXYQ16MAYL(E)+RXYQ16MAYL(E) RXYQ16MAYL(E)+RXYQ16MAYL(E)+RXYQ16MAYL(E) Model Name (Independent Unit) RXYQ14MATL(E)+RXYQ16MATL(E)+RXYQ16MATL(E) RXYQ16MATL(E)+RXYQ16MATL(E)+RXYQ16MATL(E) kcal / h 113,000 117,000 1 Cooling Capacity (19.5°CWB) Btu / h 447,000 464,000 2 Cooling Capacity (19.0°CWB) kcal / h 125,000 129,000 3 Heating Capacity Btu / h…
  • Page 32: Indoor Units

    Si39-504 Specifications Indoor Units Ceiling Mounted Cassette Type (Double Flow) Model FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE kcal/h 2,000 2,500 3,200 4,000 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 16,000 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 4,300 3 Heating Capacity Btu/h 8,500 10,900…

  • Page 33
    Specifications Si39-504 Ceiling Mounted Cassette Type (Double Flow) Model FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE kcal/h 5,000 6,300 8,000 12,500 1 Cooling Capacity (19.5°CWB) Btu/h 19,800 24,900 31,700 49,500 14.5 2 Cooling Capacity (19.0°CWB) 14.0 kcal/h 5,400 6,900 8,600 13,800 3 Heating Capacity Btu/h 21,500 27,300…
  • Page 34
    Si39-504 Specifications Ceiling Mounted Cassette Type (Multi-flow) Model FXFQ25MVE FXFQ32MVE FXFQ40MVE FXFQ50MVE kcal/h 2,500 3,200 4,000 5,000 1 Cooling Capacity (19.5°CWB) Btu/h 9,900 12,600 16,000 19,800 2 Cooling Capacity (19.0°CWB) kcal/h 2,800 3,400 4,300 5,400 3 Heating Capacity Btu/h 10,900 13,600 17,100 21,500…
  • Page 35
    Specifications Si39-504 Ceiling Mounted Cassette Type (Multi-flow) Model FXFQ63MVE FXFQ80MVE FXFQ100MVE FXFQ125MVE kcal/h 6,300 8,000 10,000 12,500 1 Cooling Capacity (19.5°CWB) Btu/h 24,900 31,700 39,600 49,500 11.6 14.5 2 Cooling Capacity (19.0°CWB) 11.2 14.0 kcal/h 6,900 8,600 10,800 13,800 3 Heating Capacity Btu/h 27,300 34,100…
  • Page 36
    Si39-504 Specifications Ceiling Mounted Cassette Corner Type Model FXKQ25MVE FXKQ32MVE FXKQ40MVE FXKQ63MVE kcal/h 2,500 3,200 4,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 9,900 12,600 16,000 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 2,800 3,400 4,300 6,900 3 Heating Capacity Btu/h 10,900 13,600 17,100 27,300…
  • Page 37
    Specifications Si39-504 Slim Ceiling Mounted Duct Type (with Drain Pump) Model FXDQ20NVE FXDQ25NVE FXDQ32NVE kcal/h 2,000 2,500 3,200 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 3 Heating Capacity Btu/h 8,500 10,900 13,600 Casing Galvanized Steel Plate…
  • Page 38
    Si39-504 Specifications Slim Ceiling Mounted Duct Type (with Drain Pump) Model FXDQ40NVE FXDQ50NVE FXDQ63NVE kcal/h 4,000 5,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 3 Heating Capacity Btu/h 17,100 21,500 27,300 Casing Color Galvanized Steel Plate…
  • Page 39
    Specifications Si39-504 Slim Ceiling Mounted Duct Type (without Drain Pump) Model FXDQ20NVET FXDQ25NVET FXDQ32NVET kcal/h 2,000 2,500 3,200 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 3 Heating Capacity Btu/h 8,500 10,900 13,600 Casing Galvanized Steel Plate…
  • Page 40
    Si39-504 Specifications Slim Ceiling Mounted Duct Type (without Drain Pump) Model FXDQ40NVET FXDQ50NVET FXDQ63NVET kcal/h 4,000 5,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 3 Heating Capacity Btu/h 17,100 21,500 27,300 Casing Color Galvanized Steel Plate…
  • Page 41
    Specifications Si39-504 Ceiling Mounted Built-in Type Model FXSQ20MVE FXSQ25MVE FXSQ32MVE kcal/h 2,000 2,500 3,200 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 3 Heating Capacity Btu/h 8,500 10,900 13,600 Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Dimensions: (H×W×D)
  • Page 42
    Si39-504 Specifications Ceiling Mounted Built-in Type Model FXSQ40MVE FXSQ50MVE FXSQ63MVE kcal/h 4,000 5,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 3 Heating Capacity Btu/h 17,100 21,500 27,300 Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Dimensions: (H×W×D)
  • Page 43
    Specifications Si39-504 Ceiling Mounted Built-in Type Model FXSQ80MVE FXSQ100MVE FXSQ125MVE kcal/h 8,000 10,000 12,500 1 Cooling Capacity (19.5°CWB) Btu/h 31,700 39,600 49,500 11.6 14.5 2 Cooling Capacity (19.0°CWB) 11.2 14.0 kcal/h 8,600 10,800 13,800 3 Heating Capacity Btu/h 34,100 42,700 54,600 10.0 12.5…
  • Page 44
    Si39-504 Specifications Ceiling Mounted Duct Type Model FXMQ40MVE FXMQ50MVE FXMQ63MVE FXMQ80MVE kcal/h 4,000 5,000 6,300 8,000 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 31,700 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 8,600 3 Heating Capacity Btu/h 17,100 21,500 27,300 34,100 10.0…
  • Page 45
    Specifications Si39-504 Ceiling Mounted Duct Type Model FXMQ100MVE FXMQ125MVE FXMQ200MVE FXMQ250MVE kcal/h 10,000 12,500 19,800 24,800 1 Cooling Capacity (19.5°CWB) Btu/h 39,600 49,500 78,500 98,300 11.6 14.5 23.0 28.8 2 Cooling Capacity (19.0°CWB) 11.2 14.0 22.4 28.0 kcal/h 10,800 13,800 21,500 27,100 3 Heating Capacity…
  • Page 46: Ceiling Suspended Type

    Si39-504 Specifications Ceiling Suspended Type Model FXHQ32MVE FXHQ63MVE FXHQ100MVE kcal/h 3,200 6,300 10,000 1 Cooling Capacity (19.5°CWB) Btu/h 12,600 24,900 39,600 11.6 2 Cooling Capacity (19.0°CWB) 11.2 kcal/h 3,400 6,900 10,800 3 Heating Capacity Btu/h 13,600 27,300 42,700 12.5 Casing Color White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5)

  • Page 47
    Specifications Si39-504 Wall Mounted Type Model FXAQ20MVE FXAQ25MVE FXAQ32MVE kcal/h 2,000 2,500 3,200 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 3 Heating Capacity Btu/h 8,500 10,900 13,600 Casing Color White (3.0Y8.5/10.5) White (3.0Y8.5/10.5) White (3.0Y8.5/10.5) Dimensions: (H×W×D)
  • Page 48
    Si39-504 Specifications Wall Mounted Type Model FXAQ40MVE FXAQ50MVE FXAQ63MVE kcal/h 4,000 5,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 3 Heating Capacity Btu/h 17,100 21,500 27,300 Casing Color White (3.0Y8.5/10.5) White (3.0Y8.5/10.5) White (3.0Y8.5/10.5) Dimensions: (H×W×D)
  • Page 49: Floor Standing Type

    Specifications Si39-504 Floor Standing Type Model FXLQ20MVE FXLQ25MVE FXLQ32MVE kcal/h 2,000 2,500 3,200 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 3 Heating Capacity Btu/h 8,500 10,900 13,600 Casing Color Ivory White (5Y7.5/1) Ivory White (5Y7.5/1) Ivory White (5Y7.5/1) Dimensions: (H×W×D)

  • Page 50
    Si39-504 Specifications Floor Standing Type Model FXLQ40MVE FXLQ50MVE FXLQ63MVE kcal/h 4,000 5,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 3 Heating Capacity Btu/h 17,100 21,500 27,300 Casing Color Ivory White (5Y7.5/1) Ivory White (5Y7.5/1) Ivory White (5Y7.5/1) Dimensions: (H×W×D)
  • Page 51
    Specifications Si39-504 Concealed Floor Standing Type Model FXNQ20MVE FXNQ25MVE FXNQ32MVE kcal/h 2,000 2,500 3,200 1 Cooling Capacity (19.5°CWB) Btu/h 7,800 9,900 12,600 2 Cooling Capacity (19.0°CWB) kcal/h 2,200 2,800 3,400 3 Heating Capacity Btu/h 8,500 10,900 13,600 Casing Color Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Dimensions: (H×W×D)
  • Page 52
    Si39-504 Specifications Concealed Floor Standing Type Model FXNQ40MVE FXNQ50MVE FXNQ63MVE kcal/h 4,000 5,000 6,300 1 Cooling Capacity (19.5°CWB) Btu/h 16,000 19,800 24,900 2 Cooling Capacity (19.0°CWB) kcal/h 4,300 5,400 6,900 3 Heating Capacity Btu/h 17,100 21,500 27,300 Casing Color Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Dimensions: (H×W×D)
  • Page 53
    Specifications Si39-504 Specifications…
  • Page 54: Part 3 Refrigerant Circuit

    Si39-504 Part 3 Refrigerant Circuit Refrigerant Circuit ……………..44 RXYQ5MA …………………44 RXYQ8MA, 10MA, 12MA …………..46 RXYQ14MA, 16MA …………….48 Functional Parts Layout …………….50 RXYQ5MA………………..50 RXYQ8MA, 10MA, 12MA ……………51 RXYQ14MA, 16MA …………….52 Refrigerant Flow for Each Operation Mode………..53 Refirgerant Circuit…

  • Page 55: Refrigerant Circuit

    Refrigerant Circuit Si39-504 Refrigerant Circuit RXYQ5MA No. in refrigerant Symbol Name Major Function system diagram Inverter compressor is operated on frequencies between 52 Hz and 210 Hz by using the inverter. The number of operating steps is as follows when Inverter compressor is Inverter compressor (INV) operated.

  • Page 56
    Si39-504 Refrigerant Circuit RXYQ5MA 3D048203 Refirgerant Circuit…
  • Page 57: Rxyq8Ma, 10Ma, 12Ma

    Refrigerant Circuit Si39-504 RXYQ8MA, 10MA, 12MA No. in refrigerant Symbol Name Major Function system diagram Inverter compressor (INV) Inverter compressor is operated on frequencies between 52 Hz and 210 Hz by using the inverter, while Standard compressor is operated with commercial power supply only.

  • Page 58
    Si39-504 Refrigerant Circuit RXYQ8MA, 10MA, 12MA 3D048033A Refirgerant Circuit…
  • Page 59: Rxyq14Ma, 16Ma

    Refrigerant Circuit Si39-504 RXYQ14MA, 16MA No. in refrigerant Symbol Name Major Function system diagram Inverter compressor (INV) Inverter compressor is operated on frequencies between 52 Hz and 210 Hz by using Standard compressor 1 the inverter, while Standard compressor is operated with commercial power supply (STD1) only.

  • Page 60
    Si39-504 Refrigerant Circuit RXYQ14MA, 16MA 3D048034A Refirgerant Circuit…
  • Page 61: Functional Parts Layout

    Functional Parts Layout Si39-504 Functional Parts Layout RXYQ5MA Plan Solenoid valve (Injection)Y4S High pressure switch (High pressure protection INV)S1PH Solenoid valve (Receiver gas discharging)Y2S Solenoid valve (Hot gas bypass)Y1S Thermistor (INV discharge pipe)R3T Front View Fan motor Pressure sensor (High pressure)S1NPH 4-way valve Electronic expansion valve coil Thermistor…

  • Page 62: Rxyq8Ma, 10Ma, 12Ma

    Si39-504 Functional Parts Layout RXYQ8MA, 10MA, 12MA Plan Solenoid valve (Hot gas bypass)Y1S Thermistor High pressure switch High pressure switch Thermistor (Discharge pipe M1C)R31T (High pressure protection)S1PH (High pressure protection)S2PH (Discharge pipe M2C)R32T Front View Fan motor Solenoid valve (Receiver gas discharging)Y2S Thermistor (Receiver outlet liquid pipe)R6T Pressure sensor…

  • Page 63: Rxyq14Ma, 16Ma

    Functional Parts Layout Si39-504 RXYQ14MA, 16MA Plan Solenoid valve (Hot gas bypass)Y1S High presure switch (High pressure protection)S3PH High pressure switch Thermistor High pressure switch Thermistor Thermistor (High pressure (Discharge pipe (Discharge pipe M3C)R33T (Discharge pipe M1C)R31T (High pressure protection)S2PH M2C)R32T protection)S1PH Front View…

  • Page 64: Refrigerant Flow For Each Operation Mode

    Si39-504 Refrigerant Flow for Each Operation Mode Refrigerant Flow for Each Operation Mode RXYQ5MA Cooling Operation Indoor unit operation Fan ON Fan ON » ON » Fan OFF » OFF » » ON » Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure gas»…

  • Page 65
    Refrigerant Flow for Each Operation Mode Si39-504 Cooling Oil Return Operation Indoor unit operation Fan ON Fan OFF » OFF » Fan OFF » ON » » ON » Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure gas» «High temperature, high pressure liquid»…
  • Page 66
    Si39-504 Refrigerant Flow for Each Operation Mode Heating Oil Return & Defrost Operation Indoor unit operation Fan OFF Fan OFF Fan OFF » ON » » OFF » » ON » Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure gas» «High temperature, high pressure liquid»…
  • Page 67
    Refrigerant Flow for Each Operation Mode Si39-504 Heating Operation Indoor unit operation Fan ON Fan OFF » ON » » OFF » » ON » Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure gas» «High temperature, high pressure liquid» «Low temperature, low pressure»…
  • Page 68
    Si39-504 Refrigerant Flow for Each Operation Mode RXYQ8MA, 10MA, 12MA Cooling Operation Indoor unit operation Fan ON Fan ON Fan OFF » ON » » OFF » » ON » «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid»…
  • Page 69
    Refrigerant Flow for Each Operation Mode Si39-504 Cooling Oil Return Indoor unit operation Fan ON Fan OFF » OFF » » ON » » ON » Fan OFF «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid» «Low temperature, low pressure»…
  • Page 70
    Si39-504 Refrigerant Flow for Each Operation Mode Heating Oil Return & Defrost Indoor unit operation » ON » » OFF » » ON » Fan OFF Fan OFF Fan OFF «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid»…
  • Page 71
    Refrigerant Flow for Each Operation Mode Si39-504 Heating Operation Indoor unit operation Fan ON Fan LL Fan OFF » ON » » OFF » » ON » «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid» «Low temperature, low pressure»…
  • Page 72
    Si39-504 Refrigerant Flow for Each Operation Mode RXYQ14MA, 16MA Cooling Operation Indoor unit operation Fan ON Fan ON Fan OFF » ON » » OFF » » ON » «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid»…
  • Page 73
    Refrigerant Flow for Each Operation Mode Si39-504 Cooling Oil Return Operation Indoor unit operation Fan ON » ON » » OFF » » ON » Fan OFF Fan OFF «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid»…
  • Page 74
    Si39-504 Refrigerant Flow for Each Operation Mode Heating Oil Return & Defrost Operation Indoor unit operation » ON » » OFF » » ON » Fan OFF Fan OFF Fan OFF «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid»…
  • Page 75
    Refrigerant Flow for Each Operation Mode Si39-504 Heating Operation Indoor unit operation Fan ON Fan LL » OFF » » ON » Fan OFF «High temperature, high pressure gas» Heat exchanger Heat exchanger Heat exchanger «High temperature, high pressure liquid» «Low temperature, low pressure»…
  • Page 76: Part 4 Function

    Si39-504 Part 4 Part 4 Part 4 Part 4 Function Function Function Function 1. Function general ……………….66 1.1 Symbol ………………..66 1.2 Operation Mode………………67 2. Basic Control………………68 2.1 Normal Operation ……………….68 2.2 Compressor PI Control…………….69 2.3 Electronic Expansion Valve PI Control………..75 2.4 Step Control of Outdoor Unit Fans …………75 2.5 Outdoor Unit Fan Control in Cooling Operation ……..76 3.

  • Page 77: Function General

    Function general Si39-504 1. Function general Symbol Symbol Electric symbol Description or function 20S1 Four way valve (Energize during heating) – Discharge pipe superheated degree DSHi – Discharge pipe superheat of inverter compressor DSHs – Discharge pipe superheat of standard compressor –…

  • Page 78: Operation Mode

    Si39-504 Function general Operation Mode Operation in stop mode Indoor unit stop or Indoor unit thermostat ON thermostat OFF Malfunction/Standby Restart standby Pressure (Compressor stop) equalization prior to startup Malfunction/ Standby Indoor unit stop or thermostat OFF Startup control Pump-down •…

  • Page 79: Basic Control

    Basic Control Si39-504 Basic Control Normal Operation 2.1.1 List of Functions in Normal Operation Function of Functional Part (Electric Part Name Symbol Symbol) Normal Cooling Normal Heating PI control, High pressure PI control, High pressure protection, Low pressure protection, Low pressure …

  • Page 80: Compressor Pi Control

    Si39-504 Basic Control Compressor PI Control Compressor PI Control Carries out the compressor capacity PI control to maintain Te at constant during cooling operation and Tc at constant during heating operation to ensure stable unit performance. [Cooling operation] Controls compressor capacity to adjust Te to Te : Low pressure equivalent saturation achieve target value (TeS).

  • Page 81
    Basic Control Si39-504 Operating Priority and Rotation of Compressors Each compressor operates in the following order of priority. INV: Inverter compressor In the case of multi-outdoor-unit system, each compressor operates in any of Pattern 1 STD1: Standard compressor 1 through Pattern 3 according to the rotation of outdoor units. STD2: Standard compressor 2 Pattern 1 Pattern 2…
  • Page 82
    Si39-504 Basic Control Compressor Step Control Compressor operations vary with the following steps according to information in «2.2 Compressor PI Control». Furthermore, the operating priority of compressors is subject to information in » Operating Priority and Rotation of Compressors». RXYQ5MA RXYQ8MA,10MA,12MA RXYQ14MA,16MA STEP…
  • Page 83
    Basic Control Si39-504 RXYQ18MA, 20MA, 22MA RXYQ24MA, 26MA, 28MA (To increase Step No.) (To decrease Step No.) (To increase Step No.) (To decrease Step No.) Master Slave Master Slave Master Slave Master Slave STEP STEP STEP STEP unit unit unit unit unit unit…
  • Page 84
    Si39-504 Basic Control RXYQ30MA, 32MA RXYQ34MA, 36MA, 38MA (To increase Step No.) (To decrease Step No.) (To increase Step No.) (To decrease Step No.) Master Slave Master Slave Master Slave Slave Master Slave Slave STEP STEP STEP STEP unit unit unit unit unit…
  • Page 85
    Basic Control Si39-504 RXYQ46MA, 48MA RXYQ40MA, 42MA, 44MA (To decrease Step No.) (To increase Step No.) (To decrease Step No.) (To increase Step No.) Master Slave Slave Master Slave Slave Master Slave Slave Master Slave Slave STEP STEP STEP STEP unit unit1 unit2…
  • Page 86: Electronic Expansion Valve Pi Control

    Si39-504 Basic Control Electronic Expansion Valve PI Control Main Motorized Valve EV1 Control Carries out the motorized valve (Y1E) PI control to maintain the evaporator outlet superheated degree (SH) at constant during heating operation to make maximum use of the outdoor unit heat exchanger (evaporator).

  • Page 87: Outdoor Unit Fan Control In Cooling Operation

    Basic Control Si39-504 Outdoor Unit Fan Control in Cooling Operation While in cooling operation, if the outdoor temperature is low, this mode provides high-pressure control using the outdoor unit fan to retain appropriate liquid pressure, thus ensuring refrigerant circulation rate to be supplied to indoor units. Upper limit of fan revolutions: Step 8 Pc <…

  • Page 88: Special Control

    Si39-504 Special Control Special Control Startup Control This control is used to equalize the pressure in the front and back of the compressor prior to the startup of the compressor, thus reducing startup loads. Furthermore, the inverter is turned ON to charge the capacitor. In addition, to avoid stresses to the compressor due to oil return or else after the startup, the following control is made and the position of the four way valve is also determined.

  • Page 89: Oil Return Operation

    Special Control Si39-504 Oil Return Operation In order to prevent the compressor from running out of oil, the oil return operation is conducted to recover oil flown out from the compressor to the system side. 3.2.1 Oil Return Operation in Cooling Operation [Start conditions] Referring to the set conditions for the following items, start the oil return operation in cooling.

  • Page 90
    Si39-504 Special Control 3.2.2 Oil Return Operation in Heating Operation Oil return preparation Outdoor Unit Actuator Oil return operation Post-oil-return operation operation 1-step increase from Compressor Upper limit control 124 Hz + ON + OFF (74 Hz + OFF + OFF) to (Pc — Pe>0.4 MPa) time STEP7 Outdoor unit fan…
  • Page 91: Defrosting Operation

    Special Control Si39-504 Defrosting Operation To defrost the outdoor unit heat exchanger while in heating operation, the defrost operation is conducted to recover the heating capacity. [Start conditions] Referring to the set conditions for the following items, start the defrosting operation. •…

  • Page 92: Pump-Down Residual Operation

    Si39-504 Special Control Pump-down Residual Operation 3.4.1 Pump-down Residual Operation in Cooling Operation If the liquid refrigerant stays in the heat exchanger at the startup of a compressor, this liquid refrigerant enters the compressor, thus resulting in diluted oil in the compressor and then degraded lubrication performance. Consequently, in order to recover the refrigerant in the heat exchanger while the compressor stops, the pump-down residual operation is conducted.

  • Page 93: Standby

    Special Control Si39-504 Standby 3.5.1 Restart Standby Used to forcedly stop the compressor for a period of five minutes, in order to prevent the frequent ON/OFF of the compressor and equalize the pressure within the refrigerant system. Actuator Operation Remarks …

  • Page 94: Stopping Operation

    Si39-504 Special Control Stopping Operation 3.6.1 When System is in Stop Mode This mode is used to define actuator operations when the system stops. Actuator Operation Compressor Outdoor unit fan Four way valve Holds Main motorized valve (EV1) 0 pls Subcooling motorized valve (EV2) 0 pls Hot gas bypass valve (SVP)

  • Page 95
    Special Control Si39-504 3.6.3 Stopping Operation of Slave Units During Master Unit is in Operation with Multi-Outdoor-Unit System While the master unit is in operation, this mode is used to set the refrigerant flow rate to a required level using a slave unit in the stopped mode.
  • Page 96: Pressure Equalization Prior To Startup

    Si39-504 Special Control Pressure Equalization prior to Startup Actuator Operation Remarks Compressor — Cooling:OFF Outdoor unit fan — Heating:STEP 4 Four way valve Holds — Main motorized valve (EV1) 0 pls — Subcooling motorized valve (EV2) 0 pls — Hot gas bypass valve (SVP) In the case of RXYQ5M, this valve turns ON.

  • Page 97: Protection Control

    Protection Control Si39-504 Protection Control High Pressure Protection Control This high pressure protection control is used to prevent the activation of protection devices due to abnormal increase of high pressure and to protect compressors against the transient increase of high pressure. [In cooling operation] In the case of multi-outdoor-unit system, each outdoor unit performs this control individually in the following sequence.

  • Page 98: Low Pressure Protection Control

    Si39-504 Protection Control Low Pressure Protection Control This low pressure protection control is used to protect compressors against the transient decrease of low pressure. [In cooling operation] In the case of multi-outdoor-unit system, the entire system performs this control in the following sequence.

  • Page 99: Discharge Pipe Protection Control

    Protection Control Si39-504 Discharge Pipe Protection Control This discharge pipe protection control is used to protect the compressor internal temperature against a malfunction or transient increase of discharge pipe temperature. Each compressor performs the discharge pipe temperature protection control individually in the following sequence.

  • Page 100: Inverter Protection Control

    Si39-504 Protection Control Inverter Protection Control Inverter current protection control and inverter fin temperature control are performed to prevent tripping due to a malfunction, or transient inverter overcurrent, and fin temperature increase. In the case of multi-outdoor-unit system, each INV compressor performs these controls in the following sequence.

  • Page 101: Std Compressor Overload Protection

    Protection Control Si39-504 STD Compressor Overload Protection This control is used to prevent abnormal heating due to overcurrent to the compressor resulting from failures of STD compressor such as locking. STD compressor ON *If the power supply is reset while in operation prohibition mode, the prohibition Demand to operate.

  • Page 102: Other Control

    Si39-504 Other Control Other Control Outdoor Unit Rotation In the case of multi-outdoor-unit system, this outdoor unit rotation is used to prevent the compressor from burning out due to unbalanced oil level between outdoor units. [Details of outdoor unit rotation] In the case of multi-outdoor-unit system, each outdoor unit is given an operating priority for the control.

  • Page 103: Emergency Operation

    Other Control Si39-504 Emergency Operation If the compressor cannot operate, this control inhibits any applicable compressor or outdoor unit from operating to perform emergency operation only with the operative compressor or outdoor unit. Caution In order to disable the compressor operation due to a failure or else, be sure to do so in emergency operation mode.

  • Page 104
    Si39-504 Other Control convenience of oil equalization. • For RXYQ14MA and 16MA, only the STD1 compressor cannot be put into operation prohibition mode for the convenience of oil equalization. • For the system with a single outdoor unit (RXYQ8MA to 16MA), automatic backup operation is not functional.
  • Page 105: Demand Operation

    Other Control Si39-504 • In order to set the slave unit 1 to operation prohibition mode, set No. 39 of Setting mode 2 to LED display (7:ON :OFF :Blink) «SLAVE 1 OPERATION PROHIBITION». H1P—-H7P (Procedure) (1) Press and hold the MODE button (BS1) for a period 7777777 777777 of 5 seconds or more.

  • Page 106: Outline Of Control (Indoor Unit)

    Si39-504 Outline of Control (Indoor Unit) 6. Outline of Control (Indoor Unit) Drain Pump Control 1. The drain pump is controlled by the ON/OFF buttons (4 button (1) — (4) given in the figure below). 6.1.1 When the Float Switch is Tripped While the Cooling Thermostat is ∗…

  • Page 107
    Outline of Control (Indoor Unit) Si39-504 6.1.3 When the Float Switch is Tripped During Heating Operation: During heating operation, if the float switch is not reset even after the 5 minutes operation, 5 seconds stop, 5 minutes operation cycle ends, operation continues until the switch is reset. 6.1.4 When the Float Switch is Tripped and “AF”…
  • Page 108: Louver Control For Preventing Ceiling Dirt

    Si39-504 Outline of Control (Indoor Unit) Louver Control for Preventing Ceiling Dirt We have added a control feature that allows you to select the range of in which air direction can be adjusted in order to prevent the ceiling surrounding the air discharge outlet of ceiling mounted cassette type units from being soiled.

  • Page 109: Thermostat Sensor In Remote Controller

    Outline of Control (Indoor Unit) Si39-504 Thermostat Sensor in Remote Controller Temperature is controlled by both the thermostat sensor in remote controller and air suction thermostat in the indoor unit. (This is however limited to when the field setting for the thermostat sensor in remote controller is set to “Use”.) Cooling If there is a significant difference in the preset temperature and the suction temperature, fine…

  • Page 110
    Si39-504 Outline of Control (Indoor Unit) Heating When heating, the hot air rises to the top of the room, resulting in the temperature being lower near the floor where the occupants are. When controlling by body thermostat sensor only, the unit may therefore be turned off by the thermostat before the lower part of the room reaches the preset temperature.
  • Page 111: Thermostat Control While In Normal Operation

    Outline of Control (Indoor Unit) Si39-504 Thermostat Control While in Normal Operation VRV multi systems are set at factory to thermostat control mode using the remote controller. While in normal thermostat differential control mode (i.e., factory set mode), the thermostat turns OFF when the system reaches a temperature of -1°C from the set temperature while in cooling operation or of +1°C from that while in heating operation.

  • Page 112: Freeze Prevention

    Si39-504 Outline of Control (Indoor Unit) Freeze Prevention Freeze When the temperature detected by liquid pipe temperature thermistor (R2T) of the indoor unit heat exchanger drops too low, the unit enters freeze prevention operation in accordance with Prevention by Off the following conditions, and is also set in accordance with the conditions given below.

  • Page 113: Heater Control

    Outline of Control (Indoor Unit) Si39-504 Heater Control The heater control is conducted in the following manner. [Normal control] While in heating operation, the heater Set temperature control (ON/OFF) is conducted as shown on the right. 2ºC 2ºC [Overload control] When the system is overloaded in heating operation, the heater will 43ºC…

  • Page 114: List Of Swing Flap Operations

    Si39-504 Outline of Control (Indoor Unit) List of Swing Flap Operations Swing flaps operate as shown in table below. Flap FXCQ FXFQ FXHQ FXAQ FXKQ Swing Horizontal Horizontal Horizontal Hot start from defrosting operation Wind direction set OFF Horizontal Horizontal Horizontal Swing Horizontal…

  • Page 115
    Outline of Control (Indoor Unit) Si39-504 Function…
  • Page 116: Part 5 Test Operation

    Si39-504 Part 5 Test Operation Test Operation ………………106 Procedure and Outline ……………..106 Operation When Power is Turned On ……….110 Outdoor Unit PC Board Layout …………111 Field Setting ………………112 Field Setting from Remote Controller ………..112 3.2 Field Setting from Outdoor Unit…………124 Test Operation…

  • Page 117: Test Operation

    Test Operation Si39-504 Test Operation Procedure and Outline Follow the following procedure to conduct the initial test operation after installation. 1.1.1 Check work prior to turn power supply on ¡ Is the wiring performed as specified? ¡ Check the below items. Is the designated wire used? ¡…

  • Page 118
    Si39-504 Test Operation 1.1.2 Turn power on ¡ Be sure to turn the power on 6 hours before starting operation to protect Turn outdoor unit and indoor compressors. (to power on clankcase heater) unit power on. ¡ Check to be sure the transmission is normal. Check the LED display of the The transmission is normal if the LEDs display conditions as shown in outdoor unit PC board.
  • Page 119
    Test Operation Si39-504 1.1.3 Check Operation * During check operation, mount front panel to avoid the misjudging. * Check operation is mandatory for normal unit operation. (When the check operation is not executed, alarm code «U3» will be displayed.) If the LED «H1P» turns OFF, the system is set to «Setting mode 1». Check Setting mode 1.
  • Page 120
    Si39-504 Test Operation Malfunction code In case of an alarm code displayed on remote controller: Cause of trouble due to faulty Alarm Countermeasure installation work code The stop valve of an outdoor unit is left Open the stop valve. closed. The phases of the power to the outdoor Exchange two of the three phases (L1, L2, L3) to make a positive units are reversed.
  • Page 121: Operation When Power Is Turned On

    Test Operation Si39-504 Operation When Power is Turned On 1.2.1 When Turning On Power First Time The unit cannot be run for up to 12 minutes to automatically set the master power and address (indoor-outdoor address, etc.). Status Outdoor unit Test lamp H2P ..

  • Page 122: Outdoor Unit Pc Board Layout

    Si39-504 Outdoor Unit PC Board Layout Outdoor Unit PC Board Layout Outdoor unit PC board C/H SELECTOR (2) Set mode display (LED) TEST: 9 MODE L.N.O.P DEMAND MASTER SLAVE HWL : 8 MULTI H1P H2P H3P H4P H5P H6P H7P (3) Mode setting switch MODE RETURN…

  • Page 123: Field Setting

    Field Setting Si39-504 Field Setting Field Setting from Remote Controller Individual function of indoor unit can be changed from the remote controller. At the time of installation or after service inspection / repair, make the local setting in accordance with the following description.

  • Page 124
    Si39-504 Field Setting 3.1.2 Wireless Remote Controller — Indoor Unit BRC7C type BRC7E type BRC4C type 1. When in the normal mode, push the “ ” button for 4 seconds or more, and operation then enters the “field set mode.” 2.
  • Page 125
    Field Setting Si39-504 3.1.3 Simplified Remote Controller BRC2A51 BRC2C51 1. Remove the upper part of remote controller. 2. When in the normal mode, press the [BS6] BUTTON ( ) (field set), and the FIELD SET MODE is entered. 3. Select the desired MODE No. with the [BS2] BUTTON ( ) (temperature setting ) and the [BS3] BUTTON ( ) (temperature setting ).
  • Page 126
    Si39-504 Field Setting 3.1.4 Setting Contents and Code No. – VRV Indoor unit Mode Setting Setting Contents Second Code No.(Note 3) Switch system indoor Note 2 unit 10(20) Filter contamination heavy/ Super Light Approx. Heavy Approx. — — settings light (Setting for display long life 10,000 5,000…
  • Page 127
    Field Setting Si39-504 3.1.5 Applicable range of Field setting Ceiling mounted cassette type Slim Ceiling Ceiling Ceiling Wall Floor Concealed Ceiling mounted mounted suspended mounted standing Floor Multi Double Corner mounted built-in duct type type type type standing flow flow type duct type type…
  • Page 128: Detailed Explanation Of Setting Modes

    Si39-504 Field Setting 3.1.6 Detailed Explanation of Setting Modes Filter Sign Setting If switching the filter sign ON time, set as given in the table below. Set Time Filter Specs. Standard Long Life Ultra Long Life Filter Setting Contamination Light 200 hrs.

  • Page 129
    Field Setting Si39-504 Air Flow Adjustment — Ceiling height Make the following setting according to the ceiling height. The setting position No. is set to “01” at the factory. In the Case of FXAQ, FXHQ Setting Switch Setting Position Mode No. Setting Wall-mounted type: Standard 13(23)
  • Page 130
    Si39-504 Field Setting Setting of Air Flow Direction Adjustment Range Make the following air flow direction setting according to the respective purpose. Setting Table Mode No. First Code No. Second Code No. Setting Upward (Draft prevention) 13 (23) Standard Downward (Ceiling soiling prevention) Air flow rate switching at discharge grille for field air flow rate switching When the optional parts (high performance filter, etc.) is installed, sets to change fan speed for…
  • Page 131
    Field Setting Si39-504 3.1.7 Centralized Control Group No. Setting BRC1A Type Set the group number of each group of the indoor unit from the remote controller. (In case of no remote controller, also connect the remote controller and set the group No. Then, remove the remote controller.) 1.
  • Page 132
    Si39-504 Field Setting BRC7C Type Group No. setting by wireless remote controller for centralized control 1. When in the normal mode, push “ ” button for 4 seconds or more, and operation then BRC7E Type enters the “field set mode.” BRC4C Type 2.
  • Page 133
    Field Setting Si39-504 3.1.8 Setting of Operation Control Mode from Remote Controller (Local Setting) The operation control mode is compatible with a variety of controls and operations by limiting the functions of the operation remote controller. Furthermore, operations such as remote controller ON/OFF can be limited in accordance with the combination conditions.
  • Page 134
    Si39-504 Field Setting How to Select Whether operation by remote controller will be possible or not for turning on/off, controlling temperature or setting operation mode is selected and decided by the operation mode given on Operation Mode the right edge of the table below. Example ON by remote OFF by remote…
  • Page 135: Field Setting From Outdoor Unit

    Field Setting Si39-504 Field Setting from Outdoor Unit 3.2.1 Field Setting from Outdoor Unit List of Field Setting Items This following section indicates the list of field setting items. For the lists of dip switch contents, Setting mode 1, and Setting mode 2, refer to information in tables shown on the following page onward.

  • Page 136
    Si39-504 Field Setting Setting item Content and objective of setting Overview of setting procedure Indoor unit fan Used to operate the indoor unit in the Set No. 5 of «Setting mode 2» to indoor unit forced H operation stopped state in forced H operation mode. forced fan H.
  • Page 137
    Field Setting Si39-504 Setting by dip switches Using dip switches on the PC board enables field setting shown below. However, make no changes of factory settings except for DS1-1. Dipswitch Setting item Description Setting Cool / Heat select Used to set cool / heat select by remote controller DS1-1 equipped with outdoor unit.
  • Page 138
    Si39-504 Field Setting “Detail of DS1-1~4, DS2-1~4 setting” Unit Setting method ( represents the position of switches) HEAT PUMP(5HP) Set DS2-1 to ON. RXYQ5MA HEAT PUMP(8HP) Set DS2-1 and DS2-3 to ON. RXYQ8MA HEAT PUMP(10HP) Set DS2-1, DS2-2 and DS2-3 RXYQ10MA to ON.
  • Page 139
    Field Setting Si39-504 Setting by pushbutton switches The following settings are made by pushbutton switches on PC board. In case of multi-outdoor unit system, various items should be set with the master unit. (Setting with the slave unit is disabled.) The master unit and slave unit can be discriminated with the LED display as shown below.
  • Page 140
    Si39-504 Field Setting a. “Setting mode 1” This mode is used to set and check the following items. 1. Set items ············ In order to make COOL/HEAT selection in a batch of outdoor unit group, change the setting. • COOL/HEAT selection (IND) ·····················Used to select COOL or HEAT by individual outdoor unit (factory set).
  • Page 141
    Field Setting Si39-504 Setting item Description b. “Setting mode 2” Cool/heat unified Sets address for cool/heat unified operation. address Push and hold the MODE (BS1) Low noise/demand Address for low noise/demand operation button for 5 seconds and set to address “Setting mode 2”.
  • Page 142
    Si39-504 Field Setting Setting item Description Emergency operation (Setting for the master unit operation prohibition in multi- outdoor-unit system) Emergency operation Used to temporarily prohibit the applicable outdoor unit (Setting for the from operating should there be any faulty part in multi- slave unit 1 outdoor-unit system.
  • Page 143
    Field Setting Si39-504 Setting item display C/H selection Setting condition display MODE TEST Demand Setting item noise Master Slave ∗ Factory set 8777777 ∗ Address Binary number 8777778 Cool / Heat Unified address (6 digits) 8788888 8777777 ∗ Address Binary number 8777778 Low noise/demand address…
  • Page 144
    Si39-504 Field Setting Setting item display C/H selection Setting condition display MODE TEST Demand Setting item noise Master Slave ∗ Factory set 8777778 ∗ ENECUT test EneCut output OFF operation (Domestic Japan only) EneCut output forced ON 8777787 Level 1 (outdoor fan with 8 step or lower) 8777778 8777787 ∗…
  • Page 145
    Field Setting Si39-504 c. Monitor mode LED display Setting item Data display To enter the monitor mode, push the 9 7 7 7 7 7 7 Various settings See below MODE (BS1) button when in “Setting mode 1”. 9 7 7 7 7 7 8 C/H unified address 9 7 7 7 7 8 7 Low noise/demand address…
  • Page 146
    Si39-504 Field Setting Push the SET button and match with the LEDs No. 1 — 15, push the RETURN button, and confirm the data for each setting. Data such as addresses and number of units is expressed as binary numbers; the two ways of expressing are as follows: The No.
  • Page 147
    Field Setting Si39-504 3.2.2 Cool / Heat Mode Switching There are the following 4 cool/heat switching modes. Set cool/heat separately for each outdoor unit system by indoor unit remote controller. Set cool/heat separately for each outdoor unit system by cool/heat switching remote controller.
  • Page 148
    Si39-504 Field Setting Set Cool / Heat Separately for Each Outdoor Unit System by Cool / Heat Switching Remote Controller It does not matter whether or not there is outdoor — outdoor unit wiring. Set outdoor unit PC board DS1-1 to OUT (factory set). Set cool/heat switching to IND (individual) for “Setting mode 1”…
  • Page 149
    Field Setting Si39-504 Set Cool / Heat for More Than One Outdoor Unit System Simultaneously in Accordance with Unified Master Outdoor Unit by Indoor Unit Remote Controller Install the external control adapter for outdoor unit on either the outdoor-outdoor, indoor- outdoor transmission line.
  • Page 150
    Si39-504 Field Setting Set Cool / Heat for More Than One Outdoor Unit System Simultaneously in Accordance with Unified Master Outdoor Unit by Cool / Heat Switching Remote Controller Install the external control adapter for outdoor unit on either the outdoor-outdoor, indoor- outdoor transmission line.
  • Page 151
    Field Setting Si39-504 Supplementation on When switching cool/heat for each adapter PC board with the use of more than one adapter PC board, set the address of the external control adaptor for outdoor unit PC board DS1 and DS2 so that it matches the unified cool/heat address of outdoor unit main PC board. Address setting for (Set lower 5 digits with binary number.) [No.0 to No.31] External control adaptor for outdoor unit…
  • Page 152
    Si39-504 Field Setting 3.2.3 Setting of Low Noise Operation and Demand Operation Setting of Low Noise Operation By connecting the external contact input to the low noise input of the outdoor unit external control adapter (optional), you can lower operating noise by 2-3 dB. Setting Content Mode 1…
  • Page 153
    Field Setting Si39-504 Image of operation in the case of A Image of operation in the case of B Image of operation in the case of A and B Test Operation…
  • Page 154
    Si39-504 Field Setting Setting of Demand Operation By connecting the external contact input to the demand input of the outdoor unit external control adapter (optional), the power consumption of unit operation can be saved suppressing the compressor operating condition. Set item Condition Content Demand 1…
  • Page 155
    Field Setting Si39-504 Image of operation in the case of A Power consumption The power Rated power consumption consumption during 80 % of rated power consumption Demand level 1 instructing Demand level 2 instructing Demand level 3 instructing the demand level 1 70 % of rated power consumption instructing can be 60 % of rated power consumption…
  • Page 156
    Si39-504 Field Setting Detailed Setting Procedure of Low Noise Operation and Demand Control 1. Setting mode 1 (H1P off) In setting mode 2, push the BS1 (MODE button) one time. → Setting mode 2 is entered and H1P lights. During the setting mode 1 is displayed, “In low noise operation” and “In demand control” are displayed.
  • Page 157
    Field Setting Si39-504 : ON : OFF : Blink Setting Setting Setting No. indication Setting No. indication Setting Setting contents indication (Initial setting) contents contents H1P H2P H3P H4P H5P H6P H7P H1P H2P H3P H4P H5P H6P H7P H1P H2P H3P H4P H5P H6P H7P External low noise / (Factory…
  • Page 158
    Si39-504 Field Setting 3.2.4 Setting of Refrigerant Additional Charging Operation When additional refrigerant is not charged all with outdoor unit in stop mode, operate the outdoor unit and charge the liquid refrigerant from the service port of liquid stop value. The additional charging operation is activated by pushbutton switch on the outdoor unit PC board.
  • Page 159
    Field Setting Si39-504 [Operation procedure detail] After turning the respective power supply switch of indoor and outdoor units off and charging the refrigerant, turn on the power of indoor and outdoor units. Do not fail to turn the power off and charge the refrigerant with outdoor unit in stop mode before adding the refrigerant following this procedure, otherwise resulting in trouble.
  • Page 160
    Si39-504 Field Setting 3.2.6 Setting of Vacuuming Mode In order to perform vacuuming operation at site, fully open the expansion valves of indoor and outdoor units and turn on some solenoid valves. [Operating procedure] With Setting Mode 2 while the unit stops, set “Refrigerant recovery / Vacuuming mode” to ON.
  • Page 161
    Field Setting Si39-504 Test Operation…
  • Page 162: Part 6 Troubleshooting

    Si39-504 Part 6 Part 6 Part 6 Part 6 Troubleshooting Troubleshooting Troubleshooting Troubleshooting 1. Symptom-based Troubleshooting …………154 2. Troubleshooting by Remote Controller ……….157 2.1 The INSPECTION / TEST Button…………157 2.2 Self-diagnosis by Wired Remote Controller ………158 2.3 Self-diagnosis by Wireless Remote Controller ……..159 2.4 Operation of The Remote Controller’s Inspection / Test Operation Button …………….162 2.5 Remote Controller Service Mode …………163…

  • Page 163
    Si39-504 3.29 “J9” Outdoor Unit: Malfunction of Subcooling Heat Exchanger Gas Pipe Thermistor (R5T) …………..203 3.30 “JA” Outdoor Unit: Malfunction of High Pressure Sensor……204 3.31 “JC” Outdoor Unit: Malfunction of Low Pressure Sensor…….205 3.32 “L4” Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise……………..206 3.33 “L5”…
  • Page 164
    Si39-504 6. Troubleshooting (OP: Unified ON/OFF Controller) ……245 6.1 Operation Lamp Blinks ……………..245 6.2 Display “Under Centralized Control” Blinks (Repeats Single Blink) ..247 6.3 Display “Under Centralized Control” Blinks (Repeats Double Blink) ..250 Troubleshooting…
  • Page 165: Symptom-Based Troubleshooting

    Symptom-based Troubleshooting Si39-504 1. Symptom-based Troubleshooting Symptom Supposed Cause Countermeasure The system does not start operation at all. Blowout of fuse(s) Turn Off the power supply and then replace the fuse(s). Cutout of breaker(s) • If the knob of any breaker is in its OFF position, turn ON the power supply.

  • Page 166
    Si39-504 Symptom-based Troubleshooting Symptom Supposed Cause Countermeasure The system This symptom occurs The system is in preparation Wait for a period of approximately conducts air immediately after turning ON mode of operation. 10 minutes. blasting the power supply. operation but not cooling or heating operation.
  • Page 167
    Symptom-based Troubleshooting Si39-504 Symptom Supposed Cause Countermeasure 12 Dust comes out Dust comes out from the Dust, which has deposited on the Normal operation. from the system. system when it restarts after inside of indoor unit, is blown out the stop for an extended period from the system.
  • Page 168: Troubleshooting By Remote Controller

    Si39-504 Troubleshooting by Remote Controller 2. Troubleshooting by Remote Controller The INSPECTION / TEST Button The following modes can be selected by using the [Inspection/Test Operation] button on the remote control. Depress Inspection/Test Operation button for more than 4 seconds. Indoor unit settings can be made Service data can be obtained.

  • Page 169: Self-Diagnosis By Wired Remote Controller

    Troubleshooting by Remote Controller Si39-504 Self-diagnosis by Wired Remote Controller Explanation If operation stops due to malfunction, the remote controller’s operation LED blinks, and malfunction code is displayed. (Even if stop operation is carried out, malfunction contents are displayed when the inspection mode is entered.) The malfunction code enables you to tell what kind of malfunction caused operation to stop.

  • Page 170: Self-Diagnosis By Wireless Remote Controller

    Si39-504 Troubleshooting by Remote Controller Self-diagnosis by Wireless Remote Controller In the Case of If equipment stops due to a malfunction, the operation indicating LED on the light reception section flashes. BRC7C Type The malfunction code can be determined by following the procedure described below. (The BRC7E Type malfunction code is displayed when an operation error has occurred.

  • Page 171
    Troubleshooting by Remote Controller Si39-504 The lower digit of the code changes as shown below when the UP and DOWN buttons are pressed. Troubleshooting…
  • Page 172
    Si39-504 Troubleshooting by Remote Controller Troubleshooting…
  • Page 173: Operation Of The Remote Controller’s Inspection / Test Operation Button

    Troubleshooting by Remote Controller Si39-504 Operation of The Remote Controller’s Inspection / Test Operation Button Unit Malfunction code Inspection Normal display (No display) Malfunction code blinks when a malfunction occurs. Inspection/test Push the button. operation Unit Example of capacity code display 0 7 1…

  • Page 174: Remote Controller Service Mode

    Si39-504 Troubleshooting by Remote Controller Remote Controller Service Mode How to Enter the Service Mode Service Mode 1. Select the mode No. Operation Set the desired mode No. with the button. (For wireless remote controller, Mode 43 only can be set.) Method 2.

  • Page 175
    Troubleshooting by Remote Controller Si39-504 Mode Function Contents and operation method Remote controller display example Malfunction Display malfunction hysteresis. hysteresis display The history No. can be changed with the Unit 1 button. Malfunction code 2-U4 Malfunction code Hystory No: 1 — 9 1: Latest (VE007) Display of sensor…
  • Page 176: Remote Controller Self-Diagnosis Function

    Si39-504 Troubleshooting by Remote Controller Remote Controller Self-Diagnosis Function The remote controller switches are equipped with a self diagnosis function so that more appropriate maintenance can be carried out. If a malfunction occurs during operation, the operation lamp, malfunction code and display of malfunctioning unit No. let you know the contents and location of the malfunction.

  • Page 177
    Troubleshooting by Remote Controller Si39-504 8: ON 7: OFF 9: Blink Malfunction Operation Inspection Unit No. Malfunction contents Page code lamp display Referred Indoor Unit Error of external protection device PC board defect, E PROM defect Malfunction of drain level control system (S1L) Fan motor (M1F) lock, overload Malfunction of swing flap motor (MA) Malfunction of moving part of electronic expansion…
  • Page 178
    Si39-504 Troubleshooting by Remote Controller 8: ON 7: OFF 9: Blink Malfunction Operation Inspection Unit No. Malfunction contents Page code lamp display Referred Outdoor Unit Malfunction of power unit — Malfunction of transmission between inverter and control PC board Inverter over-ripple protection Malfunction of inverter radiating fin temperature rise sensor System…
  • Page 179: Troubleshooting

    Troubleshooting by Remote Controller Si39-504 Malfunction code indication by outdoor unit PC board Monitor mode <Monitor mode> To enter the monitor mode, push the Contents of malfunction Malfunction MODE (BS1) button when in code “Setting mode 1”. Abnormal discharge pressure HPS activated Abnormal suction pressure Abnormal Pe…

  • Page 180
    Si39-504 Troubleshooting by Remote Controller 8: ON 7: OFF 9:Blink Malfunction Confirmation of malfunction 1 Confirmation of malfunction 2 Confirmation of malfunction 3 code Malfunction code 1st Malfunction code 2nd Malfunction Master digit display section digit display section location Slave 1 Slave 2 Troubleshooting…
  • Page 181: Troubleshooting By Indication On The Remote Controller

    Troubleshooting by Indication on the Remote Controller Si39-504 3. Troubleshooting by Indication on the Remote Controller “ A0 ” Indoor Unit: Error of External Protection Device Remote Controller Display Applicable All indoor unit models Models Method of Detect open or short circuit between external input terminals in indoor unit. Malfunction Detection Malfunction…

  • Page 182: A1″ Indoor Unit: Pc Board Defect

    Si39-504 Troubleshooting by Indication on the Remote Controller “ A1 ” Indoor Unit: PC Board Defect Remote Controller Display Applicable All indoor unit models Models Method of Check data from E²PROM. Malfunction Detection Malfunction When data could not be correctly received from the E²PROM E²PROM : Type of nonvolatile memory.

  • Page 183: A3″ Indoor Unit: Malfunction Of Drain Level Control System (S1L)

    Troubleshooting by Indication on the Remote Controller Si39-504 “ A3 ” Indoor Unit: Malfunction of Drain Level Control System (S1L) Remote Controller Display Applicable FXCQ, FXFQ, FXSQ, FXKQ, FXDQ, FXMQ, FXHQ (Option), FXMQ200,250M (Option), FXAQ (Option) Models Method of By float switch OFF detection Malfunction Detection Malfunction…

  • Page 184
    Si39-504 Troubleshooting by Indication on the Remote Controller Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Is power supply Provide 220~240V power 220~240V provided? supply. The float A short switch is connected to circuit connector is Connect either a short circuit…
  • Page 185: A6″ Indoor Unit: Fan Motor (M1F) Lock, Overload

    Troubleshooting by Indication on the Remote Controller Si39-504 “ A6 ” Indoor Unit: Fan Motor (M1F) Lock, Overload Remote Controller Display Applicable All indoor units Models Method of Detection by failure of signal for detecting number of turns to come from the fan motor Malfunction Detection Malfunction…

  • Page 186: A7″ Indoor Unit: Malfunction Of Swing Flap Motor (Ma)

    Si39-504 Troubleshooting by Indication on the Remote Controller “ A7 ” Indoor Unit: Malfunction of Swing Flap Motor (MA) Remote Controller Display Applicable FXCQ, FXHQ, FXKQ Models Method of Utilizes ON/OFF of the limit switch when the motor turns. Malfunction Detection Malfunction When ON/OFF of the microswitch for positioning cannot be reversed even though the swing flap…

  • Page 187
    Troubleshooting by Indication on the Remote Controller Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Is power supply Provide 220~240V power 220~240V provided? supply. Indoor unit is a model equipped Replace indoor unit PC board.
  • Page 188: A9″ Indoor Unit: Malfunction Of Moving Part Of

    Si39-504 Troubleshooting by Indication on the Remote Controller “ A9 ” Indoor Unit: Malfunction of Moving Part of Electronic Expansion Valve (20E) Remote Controller Display Applicable All indoor unit models Models Method of Use a microcomputer to check the electronic expansion valve for coil conditions. Malfunction Detection Malfunction…

  • Page 189
    Troubleshooting by Indication on the Remote Controller Si39-504 ∗1: Coil check method for the moving part of the electronic expansion valve Disconnect the electronic expansion valve from the PC board and check the continuity between the connector pins. (Normal) Pin No. 1.
  • Page 190: Af» Indoor Unit: Drain Level Above Limit

    Si39-504 Troubleshooting by Indication on the Remote Controller “ AF ” Indoor Unit: Drain Level above Limit Remote Controller Display Applicable FXCQ, FXFQ, FXSQ, FXKQ, FXMQ, FXDQ Models Method of Water leakage is detected based on float switch ON/OFF operation while the compressor is in non-operation.

  • Page 191: Aj» Indoor Unit: Malfunction Of Capacity Determination Device

    Troubleshooting by Indication on the Remote Controller Si39-504 “ AJ ” Indoor Unit: Malfunction of Capacity Determination Device Remote controller display Applicable All indoor unit models Models Method of Capacity is determined according to resistance of the capacity setting adaptor and the memory inside the IC memory on the indoor unit PC board, and whether the value is normal or abnormal Malfunction is determined.

  • Page 192: C4″ Indoor Unit: Malfunction Of Thermistor (R2T) For

    Si39-504 Troubleshooting by Indication on the Remote Controller “ C4 ” Indoor Unit: Malfunction of Thermistor (R2T) for Heat Exchanger Remote Controller Display Applicable All indoor unit models Models Method of Malfunction detection is carried out by temperature detected by heat exchanger thermistor. Malfunction Detection Malfunction…

  • Page 193: 3.10 » C5 » Indoor Unit

    Troubleshooting by Indication on the Remote Controller Si39-504 3.10 “ C5 ” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes Remote Controller Display Applicable All indoor unit models Models Method of Malfunction detection is carried out by temperature detected by gas pipe thermistor. Malfunction Detection Malfunction…

  • Page 194: 3.11 » C9 » Indoor Unit

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.11 “ C9 ” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air Remote Controller Display Applicable AII indoor unit models Models Method of Malfunction detection is carried out by temperature detected by suction air temperature thermistor.

  • Page 195: Cj» Indoor Unit: Malfunction Of Thermostat Sensor In

    Troubleshooting by Indication on the Remote Controller Si39-504 3.12 “ CJ ” Indoor Unit: Malfunction of Thermostat Sensor in Remote Controller Remote Controller Display Applicable AII indoor unit models Models Method of Malfunction detection is carried out by temperature detected by remote controller air temperature thermistor.

  • Page 196: E1″ Outdoor Unit: Pc Board Defect

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.13 “ E1 ” Outdoor Unit: PC Board Defect Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Check data from E²PROM Malfunction Detection Malfunction When data could not be correctly received from the E²PROM E²PROM : Type of nonvolatile memory.

  • Page 197: E3″ Outdoor Unit: Actuation Of High Pressure Switch

    Troubleshooting by Indication on the Remote Controller Si39-504 3.14 “ E3 ” Outdoor Unit: Actuation of High Pressure Switch Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Abnormality is detected when the contact of the high pressure protection switch opens. Malfunction Detection Malfunction…

  • Page 198: E4″ Outdoor Unit: Actuation Of Low Pressure Sensor

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.15 “ E4 ” Outdoor Unit: Actuation of Low Pressure Sensor Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Abnormality is detected by the pressure value with the low pressure sensor. Malfunction Detection Malfunction Error is generated when the low pressure is dropped under specific pressure.

  • Page 199: Outdoor Unit: Compressor Motor Lock

    Troubleshooting by Indication on the Remote Controller Si39-504 3.16 “ E5 ” Outdoor Unit: Compressor Motor Lock Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Inverter PC board takes the position signal from UVWN line connected between the inverter and compressor, and detects the position signal pattern.

  • Page 200: Outdoor Unit: Std Compressor Motor Overcurrent/Lock

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.17 “ E6 ” Outdoor Unit: STD Compressor Motor Overcurrent/ Lock Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Detects the overcurrent with current sensor (CT). Malfunction Detection Malfunction Malfunction is decided when the detected current value exceeds the below mentioned value for 2 seconds.

  • Page 201: Outdoor Unit: Malfunction Of Outdoor Unit Fan Motor

    Troubleshooting by Indication on the Remote Controller Si39-504 “ E7 ” 3.18 Outdoor Unit: Malfunction of Outdoor Unit Fan Motor Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction of fan motor system is detected according to the fan speed detected by hall IC when the fan motor runs.

  • Page 202
    Si39-504 Troubleshooting by Indication on the Remote Controller Troubleshooting Check No. 1 Check on pulse input of position signal of fan inverter PC board Is the LED (HAP) on fan inverter Replace the fan inverter PC PC board blinking? board. Check No.
  • Page 203: E9″ Outdoor Unit: Malfunction Of Moving Part Of

    Troubleshooting by Indication on the Remote Controller Si39-504 3.19 “ E9 ” Outdoor Unit: Malfunction of Moving Part of Electronic Expansion Valve (Y1E, Y2E) Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Check disconnection of connector Check continuity of expansion valve coil Malfunction Detection Malfunction…

  • Page 204
    Si39-504 Troubleshooting by Indication on the Remote Controller ∗1 Coil check method for the moving part of the electronic expansion valve Disconnect the electronic expansion valve from the PC board and check the continuity between the connector pins. (Normal) Pin No. 1.
  • Page 205: F3″ Outdoor Unit: Abnormal Discharge Pipe Temperature

    Troubleshooting by Indication on the Remote Controller Si39-504 3.20 “ F3 ” Outdoor Unit: Abnormal Discharge Pipe Temperature Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Abnormality is detected according to the temperature detected by the discharge pipe temperature sensor. Malfunction Detection Malfunction…

  • Page 206: Outdoor Unit: Refrigerant Overcharged

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.21 “ F6 ” Outdoor Unit: Refrigerant Overcharged Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Refrigerant overcharge is detected from the suction pipe and subcooling heat exchanger gas pipe temperature during check operation. Malfunction Detection Malfunction…

  • Page 207: Outdoor Unit: Abnormal Outdoor Fan Motor Signal

    Troubleshooting by Indication on the Remote Controller Si39-504 3.22 “ H7 ” Outdoor Unit: Abnormal Outdoor Fan Motor Signal Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Detection of abnormal signal from fan motor. Malfunction Detection Malfunction In case of detection of abnormal signal at starting fan motor. Decision Conditions Supposed…

  • Page 208: 3.23 » H9 » Outdoor Unit

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.23 “ H9 ” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air Remote Controller Display Applicable RXYQ5MA~48MA Models Method of The abnormal detection is based on current detected by current sensor. Malfunction Detection Malfunction…

  • Page 209: Outdoor Unit: Current Sensor Malfunction

    Troubleshooting by Indication on the Remote Controller Si39-504 “ J2 ” 3.24 Outdoor Unit: Current Sensor Malfunction Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected according to the current value detected by current sensor. Malfunction Detection Malfunction When the current value detected by current sensor becomes 5A or lower, or 40A or more during standard compressor operation.

  • Page 210: 3.25 » J3 » Outdoor Unit

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.25 “ J3 ” Outdoor Unit: Malfunction of Discharge Pipe Thermistor (R3, R31~33T) Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from the temperature detected by discharge pipe temperature thermistor.

  • Page 211: 3.26 » J5 » Outdoor Unit

    Troubleshooting by Indication on the Remote Controller Si39-504 3.26 “ J5 ” Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from the temperature detected by the suction pipe temperature thermistor.

  • Page 212: J6″ Outdoor Unit: Malfunction Of Thermistor (R4T) For

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.27 “ J6 ” Outdoor Unit: Malfunction of Thermistor (R4T) for Outdoor Unit Heat Exchanger Deicer Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from the temperature detected by the heat exchanger thermistor. Malfunction Detection Malfunction…

  • Page 213: 3.28 » J7 » Outdoor Unit

    Troubleshooting by Indication on the Remote Controller Si39-504 3.28 “ J7 ” Outdoor Unit: Malfunction of Receiver Outlet Liquid Pipe Thermistor (R6T) Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected according to the temperature detected by receiver outlet liquid pipe thermistor.

  • Page 214: 3.29 » J9 » Outdoor Unit

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.29 “ J9 ” Outdoor Unit: Malfunction of Subcooling Heat Exchanger Gas Pipe Thermistor (R5T) Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected according to the temperature detected by subcooling heat exchanger gas pipe thermistor.

  • Page 215: Ja» Outdoor Unit: Malfunction Of High Pressure Sensor

    Troubleshooting by Indication on the Remote Controller Si39-504 3.30 “ JA ” Outdoor Unit: Malfunction of High Pressure Sensor Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from the pressure detected by the high pressure sensor. Malfunction Detection Malfunction When the discharge pipe pressure sensor is short circuit or open circuit.

  • Page 216: Jc» Outdoor Unit: Malfunction Of Low Pressure Sensor

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.31 “ JC ” Outdoor Unit: Malfunction of Low Pressure Sensor Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from pressure detected by low pressure sensor. Malfunction Detection Malfunction When the suction pipe pressure sensor is short circuit or open circuit.

  • Page 217: 3.32 » L4 » Outdoor Unit

    Troubleshooting by Indication on the Remote Controller Si39-504 3.32 “ L4 ” Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Fin temperature is detected by the thermistor of the radiation fin. Malfunction Detection Malfunction…

  • Page 218: L5″ Outdoor Unit: Inverter Compressor Abnormal

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.33 “ L5 ” Outdoor Unit: Inverter Compressor Abnormal Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from current flowing in the power transistor. Malfunction Detection Malfunction When an excessive current flows in the power transistor. (Instantaneous overcurrent also causes activation.) Decision Conditions…

  • Page 219: L8″ Outdoor Unit: Inverter Current Abnormal

    Troubleshooting by Indication on the Remote Controller Si39-504 3.34 “ L8 ” Outdoor Unit: Inverter Current Abnormal Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected by current flowing in the power transistor. Malfunction Detection Malfunction When overload in the compressor is detected. (Inverter secondary current 13.5A: YL (380V) or 25.1A: TL (220V)) Decision Conditions…

  • Page 220: L9″ Outdoor Unit: Inverter Start Up Error

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.35 “ L9 ” Outdoor Unit: Inverter Start up Error Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Malfunction is detected from current flowing in the power transistor. Malfunction Detection Malfunction When overload in the compressor is detected during startup (Inverter secondary current 13.5A: YL (380V) or 25.1A: TL (220V)) Decision Conditions…

  • Page 221: 3.36 » Lc » Outdoor Unit

    Troubleshooting by Indication on the Remote Controller Si39-504 3.36 “ LC ” Outdoor Unit: Malfunction of Transmission Between Inverter and Control PC Board Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Check the communication state between inverter PC board and control PC board by micro- computer.

  • Page 222
    Si39-504 Troubleshooting by Indication on the Remote Controller Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Are the connectors between the main PC board (A1P), Connect transmission wiring and fan drive PC board (A3P) turn on again.
  • Page 223: P1″ Outdoor Unit: Inverter Over-Ripple Protection

    Be sure to explain to the user that Give the user a copy of «notification of inspection results»and leave there is a «power supply imbalance» it up to him to improve the imbalance. for which DAIKIN is not responsible. (V2816) Troubleshooting…

  • Page 224: P4″ Outdoor Unit: Malfunction Of Inverter Radiating Fin

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.38 “ P4 ” Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise Sensor Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Resistance of radiation fin thermistor is detected when the compressor is not operating. Malfunction Detection Malfunction…

  • Page 225: 3.39 » Uo » Outdoor Unit

    Troubleshooting by Indication on the Remote Controller Si39-504 3.39 “ UO ” Outdoor Unit: Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Short of gas malfunction is detected by discharge pipe temperature thermistor. Malfunction Detection Malfunction…

  • Page 226: Reverse Phase, Open Phase

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.40 “ U1 ” Reverse Phase, Open Phase Remote Controller Display Applicable 3 phase outdoor unit only Models Method of The phase of each phase are detected by reverse phase detection circuit and right phase or reverse phase are judged.

  • Page 227: U2″ Outdoor Unit: Power Supply Insufficient Or

    Troubleshooting by Indication on the Remote Controller Si39-504 3.41 “ U2 ” Outdoor Unit: Power Supply Insufficient or Instantaneous Failure Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Detection of voltage of main circuit capacitor built in the inverter and power supply voltage. Malfunction Detection Malfunction…

  • Page 228
    Si39-504 Troubleshooting by Indication on the Remote Controller Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Is the voltage of power Correct power supply. supply 380V (YL) or 220V (TL)? Turn on again.
  • Page 229: U3″ Outdoor Unit: Check Operation Not Executed

    Troubleshooting by Indication on the Remote Controller Si39-504 “ U3 ” Outdoor Unit: 3.42 Check Operation not executed Remote Controller Display Applicable RXYQ5MA~48MA Models Method of Check operation is executed or not Malfunction Detection Malfunction Malfunction is decided when the unit starts operation without check operation. Decision Conditions Supposed…

  • Page 230: Malfunction Of Transmission Between Indoor Units

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.43 “ U4 ” Malfunction of Transmission Between Indoor Units Remote Controller Display Applicable All model of indoor unit Models RXYQ5MA~48MA Method of Microcomputer checks if transmission between indoor and outdoor units is normal. Malfunction Detection Malfunction…

  • Page 231
    Troubleshooting by Indication on the Remote Controller Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. the indoor or outdoor unit PC board been replaced, or has the indoor — outdoor Push and hold the RESET or outdoor — outdoor unit button on the master outdoor…
  • Page 232: Remote Controller And Indoor Unit

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.44 “ U5 ” Indoor Unit: Malfunction of Transmission Between Remote Controller and Indoor Unit Remote Controller Display Applicable All models of indoor units Models Method of In case of controlling with 2-remote controller, check the system using microcomputer is signal transmission between indoor unit and remote controller (main and sub) is normal.

  • Page 233: Indoor Unit: Malfunction Of Transmission Between Outdoor Units

    Troubleshooting by Indication on the Remote Controller Si39-504 3.45 “ U7 ” Indoor Unit: Malfunction of Transmission Between Outdoor Units Remote Controller Display Applicable All models of indoor units Models Method of Microcomputer checks if transmission between outdoor units. Malfunction Detection Malfunction When transmission is not carried out normally for a certain amount of time…

  • Page 234
    Si39-504 Troubleshooting by Indication on the Remote Controller Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Is the outdoor units multi Fix the outdoor units multi connection transmission connection transmission wiring normal? wiring and reset power.
  • Page 235: U8″ Indoor Unit: Malfunction Of Transmission Between

    Troubleshooting by Indication on the Remote Controller Si39-504 3.46 “ U8 ” Indoor Unit: Malfunction of Transmission Between Main and Sub Remote Controllers Remote Controller Display Applicable All models of indoor units Models Method of In case of controlling with 2-remote controller, check the system using microcomputer if signal transmission between indoor unit and remote controller (main and sub) is normal.

  • Page 236: U9″ Indoor Unit: Malfunction Of Transmission Between

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.47 “ U9 ” Indoor Unit: Malfunction of Transmission Between Indoor and Outdoor Units in the Same System Remote Controller Display Applicable All models of indoor units Models Method of Detect the malfunction signal of any other indoor unit within the system concerned. Malfunction Detection Malfunction…

  • Page 237
    Troubleshooting by Indication on the Remote Controller Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. «U9» has been displayed for 2 Re-diagnose by display after minutes or more. passage of 2 minutes or more.
  • Page 238: Ua» Improper Combination Of Indoor And Outdoor Units

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.48 “ UA ” Improper Combination of Indoor and Outdoor Units, Indoor Units and Remote Controller Remote Controller Display Applicable All models of indoor unit RXYQ5MA~48MA Models Remote controller Method of A difference occurs in data by the type of refrigerant between indoor and outdoor units. The number of indoor units is outside of the allowable range.

  • Page 239: Uc» Address Duplication Of Centralized Controller

    Troubleshooting by Indication on the Remote Controller Si39-504 3.49 “ UC ” Address Duplication of Centralized Controller Remote Controller Display Applicable All models of indoor unit Models Centralized controller Method of The principal indoor unit detects the same address as that of its own on any other indoor unit. Malfunction Detection Malfunction…

  • Page 240: Malfunction Of Transmission Between Centralized Controller And Indoor Unit

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.50 “ UE ” Malfunction of Transmission Between Centralized Controller and Indoor Unit Remote Controller Display Applicable All models of indoor units Centralized controller Models Method of Microcomputer checks if transmission between indoor unit and centralized controller is normal. Malfunction Detection Malfunction…

  • Page 241
    Troubleshooting by Indication on the Remote Controller Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. an indoor unit once connected been removed Reset power supply or its address simultaneously for all optional changed? controllers for centralized…
  • Page 242: Uf» System Is Not Set Yet

    Si39-504 Troubleshooting by Indication on the Remote Controller 3.51 “ UF ” System is not Set yet Remote Controller Display Applicable All models of indoor units Models RXYQ5MA~48MA Method of On check operation, the number of indoor units in terms of transmission is not corresponding to that of indoor units that have made changes in temperature.

  • Page 243: Uh» Malfunction Of System, Refrigerant System Address Undefined

    Troubleshooting by Indication on the Remote Controller Si39-504 3.52 “ UH ” Malfunction of System, Refrigerant System Address Undefined Remote Controller Display Applicable All models of indoor units RXYQ5MA~48MA Models Method of Detect an indoor unit with no address setting. Malfunction Detection Malfunction…

  • Page 244: Troubleshooting (Op: Central Remote Controller)

    Si39-504 Troubleshooting (OP: Central Remote Controller) Troubleshooting (OP: Central Remote Controller) “ M1 ” PC Board Defect Remote Controller Display Applicable Central remote controller Models Method of Detect an abnormality in the DIII-NET polarity circuit. Malfunction Detection Malfunction When + polarity and — polarity are detected at the same time. Decision Conditions Supposed…

  • Page 245: M8″ Malfunction Of Transmission Between Optional

    Troubleshooting (OP: Central Remote Controller) Si39-504 “ M8 ” Malfunction of Transmission Between Optional Controllers for Centralized Control Remote Controller Display Applicable Central remote controller Models Method of Detect the malfunction according to DIII-NET transmission data. (The system will be automatically reset.) Malfunction Detection…

  • Page 246: Improper Combination Of Optional Controllerslers For Centralized Controllers

    Si39-504 Troubleshooting (OP: Central Remote Controller) “ MA ” Improper Combination of Optional Controllers for Centralized Control Remote Controller Display Applicable Central remote controller Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction When the schedule timer is set to individual use mode, other central component is present. When multiple master controller are present.

  • Page 247
    Troubleshooting (OP: Central Remote Controller) Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Cannot be used in combination with a wiring the wiring adaptor for adaptor for electrical electrical appendices appendices.
  • Page 248: Mc» Address Duplication, Improper Setting

    Si39-504 Troubleshooting (OP: Central Remote Controller) “ MC ” Address Duplication, Improper Setting Remote Controller Display Applicable Central remote controller Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction Two units are both set to master controller mode or slave controller mode. Decision Conditions Supposed…

  • Page 249: Troubleshooting (Op: Schedule Timer)

    Troubleshooting (OP: Schedule Timer) Si39-504 Troubleshooting (OP: Schedule Timer) “ UE ” Malfunction of Transmission Between Centralized Controller and Indoor Unit Remote Controller Display Applicable Schedule timer Models All models of indoor units Method of Microcomputer checks if transmission between indoor unit and centralized controller is normal. Malfunction Detection Malfunction…

  • Page 250
    Si39-504 Troubleshooting (OP: Schedule Timer) Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. an indoor unit once connected been Reset power supply removed or its address simultaneously for all optional changed? controllers for centralized control.
  • Page 251: Pc Board Defect

    Troubleshooting (OP: Schedule Timer) Si39-504 “ M1 ” PC Board Defect Remote Controller Display Applicable Schedule timer Models Method of Detect an abnormality in the DIII-NET polarity circuit. Malfunction Detection Malfunction When + polarity and — polarity are detected at the same time. Decision Conditions Supposed…

  • Page 252: M8″ Malfunction Of Transmission Between Optional

    Si39-504 Troubleshooting (OP: Schedule Timer) “ M8 ” Malfunction of Transmission Between Optional Controllers for Centralized Control Remote Controller Display Applicable Schedule timer Models Method of Detect the malfunction according to DIII-NET transmission data. (The system will be automatically reset.) Malfunction Detection Malfunction…

  • Page 253: Improper Combination Of Optional Controllerslers For Centralized Controllers

    Troubleshooting (OP: Schedule Timer) Si39-504 “ MA ” Improper Combination of Optional Controllers for Centralized Control Remote Controller Display Applicable Schedule timer Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction When the schedule timer is set to individual use mode, other central component is present. When multiple master controller are present.

  • Page 254
    Si39-504 Troubleshooting (OP: Schedule Timer) Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Cannot be used in combination with a wiring Is the wiring adaptor for electrical adaptor for electrical appendices.
  • Page 255: Mc» Address Duplication, Improper Setting

    Troubleshooting (OP: Schedule Timer) Si39-504 “ MC ” Address Duplication, Improper Setting Remote Controller Display Applicable Schedule timer Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction When two or more schedule timers are connected. Decision Conditions Supposed…

  • Page 256: Troubleshooting (Op: Unified On/Off Controller)

    Si39-504 Troubleshooting (OP: Unified ON/OFF Controller) Troubleshooting (OP: Unified ON/OFF Controller) Operation Lamp Blinks Remote Operation lamp blinks Controller Display Applicable All model of indoor units Unified ON/OFF controller Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction…

  • Page 257
    Troubleshooting (OP: Unified ON/OFF Controller) Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Is a malfunction code displayed on the Diagnose the cause with the remote controller? air conditioner’s failure diagnosis manual.
  • Page 258: Display «Under Centralized Control» Blinks (Repeats Single Blink)

    Si39-504 Troubleshooting (OP: Unified ON/OFF Controller) Display “Under Centralized Control” Blinks (Repeats Single Blink) Remote “under centralized control” (Repeats single blink) Controller Display Applicable Unified ON/OFF controller Central remote controller, Schedule timer Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction…

  • Page 259
    Troubleshooting (OP: Unified ON/OFF Controller) Si39-504 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, Caution or parts damage may be occurred. Has a once connected optional controller for centralized Reset power supply control been disconnected simultaneously for all optional or itsaddress controllers for centralized…
  • Page 260
    Si39-504 Troubleshooting (OP: Unified ON/OFF Controller) Is the wiring adaptor for Cannot be used in electrical appendices combination with a wiring connected? adaptor for electrical appendices. Remove the wiring adaptor for electrical appendices and reset the power supply for all optional controllers for centralized control simultaneously.
  • Page 261: Display «Under Centralized Control» Blinks (Repeats Double Blink)

    Troubleshooting (OP: Unified ON/OFF Controller) Si39-504 Display “Under Centralized Control” Blinks (Repeats Double Blink) Remote “under centralized control” (Repeats double blink) Controller Display Applicable Unified ON/OFF controller Models Method of Detect the malfunction according to DIII-NET transmission data. Malfunction Detection Malfunction When no central control addresses are set to indoor units.

  • Page 262
    Si39-504 Troubleshooting (OP: Unified ON/OFF Controller) Check No. 1 Check on pulse input of position signal of fan inverter PC board (1) Disconnect the connector X2A while power supply OFF and operation OFF. (2) Is the voltage between pins No. 4 and 5 on X2A approx. 15 V after power supply is turned (3) Connect the connector X2A while power supply OFF and operation OFF.
  • Page 263
    Troubleshooting (OP: Unified ON/OFF Controller) Si39-504 Check No. 2 Check on connector of fan motor (Power supply cable) (1) Turn off the power supply. Measure the resistance between phases of U,V,W at the motor side connectors (three-core wire) to check that the values are balanced and there is no short circuiting, while connector or relay connector is disconnected.
  • Page 264: Part 7 Appendix

    Si39-504 Part 7 Part 7 Part 7 Part 7 Appendix Appendix Appendix Appendix 1. Piping Diagrams………………254 1.1 Outdoor Unit ………………254 1.2 Indoor Unit………………..257 2. Wiring Diagrams for Reference…………259 2.1 Outdoor Unit ………………259 2.2 Field Wiring ………………265 2.3 Indoor Unit………………..271 3. List of Electrical and Functional Parts ……….283 3.1 Outdoor Unit ………………283 3.2 Indoor Side ……………….287 4.

  • Page 265: Piping Diagrams

    Piping Diagrams Si39-504 1. Piping Diagrams Outdoor Unit RXYQ5MAYL(E), TL(E) 3D048203 Appendix…

  • Page 266
    Si39-504 Piping Diagrams RXYQ8MA / 10MA / 12MAYL(E), TL(E) 3D048033A Appendix…
  • Page 267
    Piping Diagrams Si39-504 RXYQ14MA / 16MAYL(E), TL(E) 3D048034A Appendix…
  • Page 268: Indoor Unit

    Si39-504 Piping Diagrams Indoor Unit FXCQ, FXFQ, FXKQ, FXSQ, FXMQ, FXHQ, FXAQ, FXLQ, FXNQ Gas piping connection port Heat exchanger Flare connection : φ15.9 or less Attached piping : Above φ19.1 Liquid piping connection port (Flare connection) Electronic Filter Filter expansion valve DU220-602J Code…

  • Page 269
    Piping Diagrams Si39-504 FXDQ 4D043864E Refrigerant pipe connection port diameters (mm) Model Liquid φ12.7 φ6.4 FXDQ20N / 25N / 32N / 40N / 50NVE(T) φ15.9 φ9.5 FXDQ63NVE(T) Appendix…
  • Page 270: Wiring Diagrams For Reference

    Si39-504 Wiring Diagrams for Reference 2. Wiring Diagrams for Reference Outdoor Unit 2.1.1 RXYQ-MAYL(E) RXYQ5MAYL(E) Appendix…

  • Page 271
    Wiring Diagrams for Reference Si39-504 RXYQ8MA / 10MA / 12MAYL(E) Appendix…
  • Page 272
    Si39-504 Wiring Diagrams for Reference RXYQ14MA / 16MAYL(E) Appendix…
  • Page 273
    Wiring Diagrams for Reference Si39-504 2.1.2 RXYQ-MATL(E) RXYQ5MATL(E) Appendix…
  • Page 274
    Si39-504 Wiring Diagrams for Reference RXYQ8MA / 10MA / 12MATL(E) Appendix…
  • Page 275
    Wiring Diagrams for Reference Si39-504 RXYQ14MA / 16MATL(E) Appendix…
  • Page 276: Field Wiring

    Si39-504 Wiring Diagrams for Reference Field Wiring 2.2.1 RXYQ-MAYL(E) RXYQ5MA / 8MA / 10MA / 12MA / 14MA / 16MAYL(E) Appendix…

  • Page 277
    Wiring Diagrams for Reference Si39-504 RXYQ18MA / 20MA / 22MA / 24MA / 26MA / 28MA / 30MA / 32MAYL(E) Appendix…
  • Page 278
    Si39-504 Wiring Diagrams for Reference RXYQ34MA / 36MA / 38MA / 40MA / 42MA / 44MA / 46MA / 48MAYL(E) Appendix…
  • Page 279
    Wiring Diagrams for Reference Si39-504 2.2.2 RXYQ-MATL(E) RXYQ5MA / 8MA / 10MA / 12MA / 14MA / 16MATL(E) Appendix…
  • Page 280
    Si39-504 Wiring Diagrams for Reference RXYQ18MA / 20MA / 22MA / 24MA / 26MA / 28MA / 30MA / 32MATL(E) Appendix…
  • Page 281
    Wiring Diagrams for Reference Si39-504 RXYQ34MA / 36MA / 38MA / 40MA / 42MA / 44MA / 46MA / 48MATL(E) Appendix…
  • Page 282: Indoor Unit

    Si39-504 Wiring Diagrams for Reference Indoor Unit FXCQ20M / 25M / 32M / 63MVE Appendix…

  • Page 283
    Wiring Diagrams for Reference Si39-504 FXCQ40M / 50M / 80M / 125MVE Appendix…
  • Page 284
    Si39-504 Wiring Diagrams for Reference FXFQ25M / 32M / 40M / 50M / 63M / 80M / 100M / 125MVE Appendix…
  • Page 285
    Wiring Diagrams for Reference Si39-504 FXKQ25M / 32M / 40M / 63MVE Appendix…
  • Page 286
    Si39-504 Wiring Diagrams for Reference FXDQ20N / 25N / 32N / 40N / 50N / 63NVE (with Drain Pump) Appendix…
  • Page 287
    Wiring Diagrams for Reference Si39-504 FXDQ20N / 25N / 32N / 40N / 50N / 63NVET (without Drain Pump) Appendix…
  • Page 288
    Si39-504 Wiring Diagrams for Reference FXSQ20M / 25M / 32M / 40M / 50M / 63M / 80M / 100M / 125MVE Appendix…
  • Page 289
    Wiring Diagrams for Reference Si39-504 FXMQ40M / 50M / 63M / 80M / 100M / 125MVE Appendix…
  • Page 290
    Si39-504 Wiring Diagrams for Reference FXMQ200M / 250MVE Appendix…
  • Page 291
    Wiring Diagrams for Reference Si39-504 FXHQ32M / 63M / 100MVE Appendix…
  • Page 292
    Si39-504 Wiring Diagrams for Reference FXAQ20M / 25M / 32MVE / 40M / 50M / 63MVE Appendix…
  • Page 293
    Wiring Diagrams for Reference Si39-504 FXLQ20M / 25M / 32M / 40M / 50M / 63MVE FXNQ20M / 25M / 32M / 40M / 50M / 63MVE Appendix…
  • Page 294: List Of Electrical And Functional Parts

    Si39-504 List of Electrical and Functional Parts List of Electrical and Functional Parts Outdoor Unit 3.1.1 RXYQ5MAY1~16MAYL Model Item Name Symbol RXYQ5MAYL RXYQ8MAYL RXYQ10MAYL Type JT1G-VDKYR@T Inverter OC protection 13.5A device Type JT170G-KYH@T Compressor STD 1 — OC protection 15.0A device Type STD 2…

  • Page 295
    List of Electrical and Functional Parts Si39-504 Model Item Name Symbol RXYQ12MAYL RXYQ14MAYL RXYQ16MAYL Type JT1G-VDKYR@T Inverter OC protection 13.5A device Type JT170G-KYH@T Compressor STD 1 OC protection 15.0A device Type JT170G-KYH@T STD 2 — OC protection 15.0A device OC protection Fan motor 1.8A device…
  • Page 296
    Si39-504 List of Electrical and Functional Parts 3.1.2 RXYQ5MAY1~16MATL Model Item Name Symbol RXYQ5MATL RXYQ8MATL RXYQ10MATL Type JT100G-VDK@S3 Inverter OC protection 25.1A device Type JT170G-K Compressor STD 1 — OC protection device Type STD 2 — OC protection device OC protection Fan motor 3.2A 6.4A…
  • Page 297
    List of Electrical and Functional Parts Si39-504 Model Item Name Symbol RXYQ12MATL RXYQ14MATL RXYQ16MATL Type JT100G-VDK@S3 Inverter OC protection 25.1A device Type JT170G-K Compressor STD 1 OC protection device Type JT170G-K STD 2 — OC protection device OC protection Fan motor 6.4A device Electronic expansion valve (Main)
  • Page 298: Indoor Side

    Si39-504 List of Electrical and Functional Parts Indoor Side 3.2.1 Indoor Unit Model Parts Name Symbol Remark FXFQ25 FXFQ32 FXFQ40 FXFQ50 FXFQ63 FXFQ80 FXFQ100 FXFQ125 Wired Remote BRC1A61 Option Controller Remote Controller Wireless Remote BRC7E61W Option Controller Fan Motor DC380V 30W 8P DC 380V 120W 8P AC220-240V (50Hz) AC220V (60Hz) Drain Pump…

  • Page 299
    List of Electrical and Functional Parts Si39-504 Model Parts Name Symbol Remark FXKQ FXKQ FXKQ FXKQ 25MVE 32MVE 40MVE 63MVE Wired Remote BRC1A61 Option Controller Remote Controller Wireless Remote BRC4C61 Controller AC 220~240V 50Hz 1φ15W 4P 1φ20W 4P 1φ45W 4P Fan Motor Thermal protector 120°C : OFF 105°C :…
  • Page 300
    Si39-504 List of Electrical and Functional Parts Model Parts Name Symbol Remark FXSQ FXSQ FXSQ FXSQ FXSQ FXSQ FXSQ FXSQ FXSQ 20MVE 25MVE 32MVE 40MVE 50MVE 63MVE 80MVE 100MVE 125MVE Wired Remote BRC1A62 Controller Remote Option Controller Wireless Remote BRC4C62 Controller AC 220~240V 50Hz 1φ125…
  • Page 301
    List of Electrical and Functional Parts Si39-504 Model Parts Name Symbol Remark FXHQ FXHQ FXHQ 32MVE 63MVE 100MVE Wired Remote BRC1A61 Option Remote Controller Controller Wireless Controller BRC7E63W AC 220~240V/220V 50Hz/60Hz Fan Motor 1φ63W 1φ130W Thermal protector 130°C : OFF 80°C : ON Motors 9.0µF-400V…
  • Page 302
    Si39-504 List of Electrical and Functional Parts Model Parts Name Symbol Remark FXLQ FXLQ FXLQ FXLQ FXLQ FXLQ 20MVE 25MVE 32MVE 40MVE 50MVE 63MVE Wired Remote BRC1A62 Controller Remote Option Controller Wireless Remote BRC4C62 Controller AC 220~240V 50Hz Fan Motor 1φ15W 1φ25W 1φ35W…
  • Page 303: Option List

    Option List Si39-504 Option List Option List of Controllers Operation Control System Optional Accessories Type FXLQ-M FXCQ-M FXFQ-M FXKQ-M FXDQ-N FXSQ-M FXMQ-M FXHQ-M FXAQ-M FXNQ-M Item Wireless BRC7C62 BRC7E61W BRC4C61 BRC4C62 BRC4C62 BRC7E63W BRC7E618 BRC4C62 Remote controller Wired BRC1A61 BRC1A62 BRC1A62 BRC1A61 BRC1A62…

  • Page 304
    Si39-504 Option List Building management system Part name Model No. Function intelligent • Air-Conditioning management system that can be controlled by a basic Hardware Touch DCS601C51 compact all-in-one unit. Controller DIII-NET Hardware plus DCS601A52 • Additional 64 groups (10 outdoor units) is possible. adaptor Option P.P.D.
  • Page 305: Option Lists (Outdoor Unit)

    Option List Si39-504 Option Lists (Outdoor Unit) RXYQ5MAY1 ~ 16MAYL(E), TL(E) RXYQ12MAYL(E), TL(E) RXYQ8MAYL(E), TL(E) Optional accessories RXYQ5MAYL(E), TL(E) RXYQ14MAYL(E), TL(E) RXYQ10MAYL(E), TL(E) RXYQ16MAYL(E), TL(E) Cool/Heat Selector KRC19-26A Fixing box KJB111A KHRP26M22H KHRP26M22H KHRP26M22H (Max. 4 branch), (Max. 4 branch), (Max.

  • Page 306: Piping Installation Point

    Si39-504 Piping Installation Point Piping Installation Point Piping Installation Point The projection part between multi connection piping kits When the piping length between the multi connection kits or between multi connection kit and outdoor unit is 2m or more, prepare a vertical projection part (200mm or more as shown below) only on the gas pipe line location less than 2m from multi connection kit.

  • Page 307: The Example Of A Wrong Pattern

    Piping Installation Point Si39-504 The Example of A Wrong Pattern Wrong × Oil is collected to the outdoor unit at the time of a stop, because of bottom omission of piping. V3039 Outdoor Unit — Multi Connection Piping Kit Actual piping length 10m or less, equivalent length 13m or less Max.allowable Actual piping length 150m or less, equivalent length 175m or Multi Connection Piping Kit — Indoor Unit…

  • Page 308: Selection Of Pipe Size, Joints And Header

    Si39-504 Selection of Pipe Size, Joints and Header 6. Selection of Pipe Size, Joints and Header Example of connection (R-410A Type) RXYQ5~48MA(Heat Pump) Appendix…

  • Page 309
    Selection of Pipe Size, Joints and Header Si39-504 ∗Note 1 Appendix…
  • Page 310: Thermistor Resistance / Temperature Characteristics

    Si39-504 Thermistor Resistance / Temperature Characteristics Thermistor Resistance / Temperature Characteristics Indoor unit For air suction For liquid pipe For gas pipe Outdoor unit for fin thermistor R1T Outdoor unit For outdoor air For coil For suction pipe For Receiver gas pipe For Receiver outlet liquid pipe (kΩ) TºC…

  • Page 311
    Thermistor Resistance / Temperature Characteristics Si39-504 Outdoor Unit Thermistors for Discharge Pipe ∼ (R3T, R31 33T) (kΩ)) T°C T°C T°C 640.44 624.65 72.32 70.96 13.35 13.15 609.31 594.43 69.64 68.34 12.95 12.76 579.96 565.78 67.06 65.82 12.57 12.38 552.00 538.63 64.60 63.41 12.20…
  • Page 312: Pressure Sensor

    Si39-504 Pressure Sensor Pressure Sensor = 1.38V-0.69 : Detected Pressure [High Side] MPa = 0.57V-0.28 : Detected Pressure [Low Side] MPa : High pressure (MPa) : Output Voltage [High Side] V Detected Pressure : Low pressure (MPa) : Output Voltage [Low Side] V V : Voltage (V) High Pressure (P Low Pressure (P…

  • Page 313: Method Of Replacing The Inverter’s Power Transistors And Diode Modules

    Method of Replacing The Inverter’s Power Transistors and Diode Modules Si39-504 Method of Replacing The Inverter’s Power Transistors and Diode Modules Method of Replacing The Inverter’s Power Transistors and Diode Modules Inverter PC board Inverter PC board (A2P) PC0409 Fasten Tab X11A Electronic circuit IGBT…

  • Page 314
    Si39-504 Method of Replacing The Inverter’s Power Transistors and Diode Modules Power Transistor IGBT (On Inverter PC Board) (Decision) If other than given above, the power unit is defective and must be replaced. Note: Above figures are measured by analogue tester. Make sure to set “Tester Range” to “x 1k”. Diode Module (Decision) If other than given above, the diode module is defective and must be replaced.
  • Page 315
    Method of Replacing The Inverter’s Power Transistors and Diode Modules Si39-504 Appendix…
  • Page 316: Part 8 Precautions For New Refrigerant (R-410A)

    Si39-504 Part 8 Precautions for New Precautions for New Precautions for New Precautions for New Refrigerant (R-410A) Refrigerant (R-410A) Refrigerant (R-410A) Refrigerant (R-410A) 1. Precautions for New Refrigerant (R-410A) ………306 1.1 Outline ………………..306 1.2 Refrigerant Cylinders…………….308 1.3 Service Tools………………309 Precautions for New Refrigerant (R-410A)

  • Page 317: Precautions For New Refrigerant (R-410A)

    Precautions for New Refrigerant (R-410A) Si39-504 Precautions for New Refrigerant (R-410A) Outline 1.1.1 About Refrigerant R-410A Characteristics of new refrigerant, R-410A 1. Performance Almost the same performance as R-22 and R-407C 2. Pressure Working pressure is approx. 1.4 times more than R-22 and R-407C. 3.

  • Page 318
    Si39-504 Precautions for New Refrigerant (R-410A) Thermodynamic characteristic of R-410A Temperature Steam pressure Density Specific heat at constant Specific enthalpy Specific entropy (kPa) (kg/m pressure (kJ/kgK) (kJ/kg) (kJ/KgK) Liquid Vapor Liquid Vapor Liquid Vapor Liquid Vapor Liquid Vapor Precautions for New Refrigerant (R-410A)
  • Page 319: Refrigerant Cylinders

    Precautions for New Refrigerant (R-410A) Si39-504 Refrigerant Cylinders Cylinder specifications 2 The cylinder is painted refrigerant color (pink). 2 The cylinder valve is equipped with a siphon tube. Cylinder Refrigerant can be charged in liquid state with cylinder in upright position. Caution: Do not lay cylinder on its side during charging, since it cause refrigerant in gas state to enter the system.

  • Page 320: Service Tools

    Si39-504 Precautions for New Refrigerant (R-410A) Service Tools R-410A is used under higher working pressure, compared to previous refrigerants (R-22,R-407C). Furthermore, the refrigerating machine oil has been changed from Suniso oil to Ether oil, and if oil mixing is occurred, sludge results in the refrigerants and causes other problems.

  • Page 321
    Precautions for New Refrigerant (R-410A) Si39-504 1. Flaring tool Flare gauge Specifications 2 Dimension A Unit:mm Tube O.D. −0.4 Nominal size Class-2 (R-410A) Class-1 (Conventional) 6.35 9.52 13.2 13.0 12.70 16.6 16.2 15.88 19.7 19.4 19.05 24.0 23.3 Differences 2 Change of dimension A Dimension A For class-1: R-407C For class-2: R-410A…
  • Page 322
    Si39-504 Precautions for New Refrigerant (R-410A) 2. Torque wrench Specifications 2 Dimension B Unit:mm Nominal size Class-1 Class-2 Previous No change in tightening torque No change in pipes of other sizes Differences 2 Change of dimension B Only 1/2″, 5/8″ are extended For class-1: R-407C For class-2: R-410A Dimension B…
  • Page 323
    Precautions for New Refrigerant (R-410A) Si39-504 4. Leak tester Specifications 2 Hydrogen detecting type, etc. 2 Applicable refrigerants R-410A, R-407C, R-404A, R-507A, R-134a, etc. Differences 2 Previous testers detected chlorine. Since HFCs do not contain chlorine, new tester detects hydrogen. 5.
  • Page 324
    Si39-504 Precautions for New Refrigerant (R-410A) 2 Temperature scale indicates the relationship between pressure and temperature in gas saturated state. Differences 2 Change in pressure 2 Change in service port diameter 7. Charge hose for R-410A (Hose with ball valve) Specifications 2 Working pressure 5.08 MPa (51.8 kg/cm 2 Rupture pressure 25.4 MPa (259 kg/cm…
  • Page 325
    Precautions for New Refrigerant (R-410A) Si39-504 9. Weigher for refrigerant charge Specifications 2 High accuracy TA101A (for 10-kg cylinder) = ± 2g TA101B (for 20-kg cylinder) = ± 5g 2 Equipped with pressure-resistant sight glass to check liquid refrigerant charging. 2 A manifold with separate ports for HFCs and previous refrigerants is equipped as standard accessories.
  • Page 326: Index

    Si39-504 Index Index Index Index E5 ……………. 188 E6 ……………. 189 A0 ……………..170 E7 ……………. 190 A1 ……………..171 E9 ……………. 192 A3 ……………..172 Electronic Expansion Valve PI Control ….75 A6 ……………..174 Emergency Operation ……….. 92 A7 ……………..175 Error of External Protection Device ….. 170 A9 ……………..177 Abnormal Discharge Pipe Temperature ….194 Abnormal Outdoor Fan Motor Signal ….196…

  • Page 327
    Si39-504 L8 ……………..208 Malfunction of Transmission Between Optional L9 ……………..209 Controllers for Centralized Control ..234, 241 LC ……………..210 Malfunction of Transmission Between List of Electrical and Functional Parts ….283 Outdoor Units ……….222 Indoor Unit ………….287 Malfunction of Transmission Between Remote Outdoor Unit ……….283 Controller and Indoor Unit ……
  • Page 328
    Si39-504 Special Control …………77 Specifications …………10 Indoor Units ………….21 Outdoor Units ……….10 Standby …………..82 Startup Control …………77 STD Compressor Motor Overcurrent/Lock …189 STD Compressor Overload Protection ….90 Step Control of Outdoor Unit Fans ……75 Stopping Operation ……….83 Symptom-based Troubleshooting ……154 System is not Set yet ………..231 Test Operation ………….106 Procedure and Outline ……..106…
  • Page 329
    Si39-504 Drawings & Flow Charts Drawings & Flow Charts Drawings & Flow Charts Drawings & Flow Charts Abnormal Discharge Pipe Temperature ….194 Improper Combination of Indoor and Outdoor Units, Abnormal Outdoor Fan Motor Signal ….196 Indoor Units and Remote Controller …. 227 Actuation of High Pressure Switch …….186 Improper Combination of Optional Controllers for Actuation of Low Pressure Sensor …….187…
  • Page 330
    Si39-504 Malfunction of Transmission Between Indoor and Outdoor Units in the Same System ….225 Test Operation ………… 106 Malfunction of Transmission Between Thermostat Sensor in Remote Controller ….98 Indoor Units ………..219 Cooling …………98 Malfunction of Transmission Between Inverter and Heating …………
  • Page 331
    Printed in Singapore 01/2006 COS…

На этой странице размещены каталоги и инструкции на кондиционеры Daikin.

График Daikin VRV RXYQ-P.pdf

Диагностика отказов Daikin VRV H.pdf
Диагностика отказов Daikin VRV K, RSN.pdf

Инструкция сервисная Daikin FXHQ32-63-100MVE, FXHQ32-63-100MAVE.pdf 
Инструкция сервисная Daikin VRV инверторы серии G,H,K система VRV 60 Гц 1997 1-26.pdf
Инструкция сервисная Daikin VRV серии G,H,K внутренний блок.pdf
Инструкция сервисная Daikin VRV различные установки серий G,H.pdf
Инструкция сервисная Daikin VRV различные установки серий K+RSNY.pdf
Инструкция сервисная Daikin VRV различные установки серий RSNY.pdf
Инструкция сервисная Daikin VRV серии G,H,K функциональные части холод.системы.pdf
Инструкция сервисная Daikin VRV серии G,H,K устройства Защиты.pdf
Инструкция сервисная Daikin VRV устранение неисправностей для серии G.pdf
Инструкция сервисная Daikin VRV устранение неисправностей для серии H,K.pdf
Инструкция сервисная Daikin VRV устранение неисправностей для RSNY8KTAL.pdf
Инструкция сервисная Daikin VRV диагностика отказов (ДО) G и H с ДПУ.pdf
Инструкция сервисная Daikin VRV ДО G и H самодиагностикой инвертора.pdf
Инструкция сервисная Daikin VRV ДО, не выводимых на ЦПУ .pdf
Инструкция сервисная Daikin VRV ДО (H) ЦПУ, таймера и ПУ вкл-выкл .pdf
Инструкция сервисная Daikin VRV ДО (K) и RSNY8KTAL с ДПУ .pdf
Инструкция сервисная Daikin VRV ДО (K) и RSNY8KTAL с ДПУ, ЦПУ, таймера, ПУ вкл-выкл.pdf
Инструкция сервисная Daikin VRV типичные ошибки в электросоединениях.pdf
Инструкция сервисная Daikin VRV серии G,H,K особенности замены печатных плат VRV.pdf
Инструкция сервисная Daikin VRV серии G,H,K аварийные ситуации.pdf
Инструкция сервисная Daikin VRV Серии G,H,K дополнительное оборудование.pdf
Инструкция сервисная Daikin VRV Серии G,H,K электрические схемы.pdf
Daikin Corrections in number of connectable indoor units and capacity index for RXYSQ 12-009.pdf
Daikin Inpact of connection ratio on capacity and Power Input RXYQ-P.pdf
Installation limits Daikin VRV3 RXYQ-P.pdf
Защита систем кондиционирования фирмы «DAIKIN» от сбоев силового электроптания 13.09.99.pdf
Инструкция сервисная Daikin VRV Basic Training Manual Si30-408.pdf
Инструкция сервисная Daikin VRV II Heat Pump RXYQ-MY Si39-302.pdf
Инструкция сервисная Daikin VRV II R-410A Heat Pump 50Hz SiE39-404.pdf
Инструкция сервисная Daikin VRV II R22 Heat Pump, Cooling Only Si38-304.pdf
Инструкция сервисная Daikin VRV II введение EEDU05-2 06.2005.pdf
Инструкция сервисная Daikin VRV II диагностический лист RXYQ-MY Si39-302.pdf
Инструкция сервисная Daikin VRV II,VRV WII EEDE05-2.pdf
Инструкция сервисная Daikin VRV III Air-cooled selection procedure EEDEN08-200.pdf
Инструкция сервисная Daikin VRV III Cooling Only 50 Hz ED 34-862.pdf
Инструкция сервисная Daikin VRV III,VRV WIII EEDRU10-200 05.10.pdf
Инструкция сервисная Daikin VRV III,VRV WIII Введение EEDRU12-200 03.12.pdf
Инструкция сервисная Daikin VRV III-S,VRV III EEDRU08-200 06.2008.pdf
Инструкция сервисная Daikin VRV III-S,VRV III,VRV II Air-cooled selection procedure EEDE06-2.pdf
Инструкция сервисная Daikin VRV III-S,VRV III,VRV II,VRV WII Ведение EEDE06-2 06.2006.pdf
Инструкция сервисная Daikin VRV Installation Work INVERTER K Series, Plus Series SM-22.pdf
Инструкция сервисная Daikin VRV Inverter DRIVEN AIR–CONDITIONING SYSTEMS SiE-55.pdf
Инструкция сервисная Daikin VRV Inverter K Series 28-08-2000.pdf
Инструкция сервисная Daikin VRV Inverter K Series, PLUS Series Si-05B.pdf
Инструкция сервисная Daikin VRV Inverter K Series, PLUS Series Si-52C.pdf
Инструкция сервисная Daikin VRV PLUS Series Appendix of Installation SiE33-003.pdf
Инструкция сервисная Daikin VRV PLUS Series R-407C SiE33-003.pdf
Инструкция сервисная Daikin VRV R-22 PLUS Series Appendix of Installation SiE33-102.pdf
Инструкция сервисная Daikin VRV R-22 PLUS Series SiE33-102.pdf
Инструкция сервисная Daikin VRV Service Diagnosis Si30-701.pdf
Инструкция сервисная Daikin VRV Service Diagnosis Si30-701A.pdf
Инструкция сервисная Daikin VRV Start Up K-serie VS3-0399.pdf
Инструкция сервисная Daikin VRV Water-cooled EEDEN12-201 02.12.pdf
Инструкция сервисная Daikin VRV WII InstallationProcedure EEDEN08-201 01.2008.pdf
Инструкция сервисная Daikin VRV WII Water-Cooled EEDE06-2 06.2006.pdf
Инструкция сервисная Daikin VRV введение EEDEN10-200 05.10.pdf
Инструкция сервисная Daikin VRV введение EEDRU13-200 03.13.pdf
Инструкция сервисная Daikin VRV замена инверторного компрессора Si39-302.pdf
Инструкция сервисная Daikin VRV инверторы серии G,H,K 60Гц высокотемературные.pdf
Инструкция сервисная Daikin VRV коды ошибок SME-TS1.pdf
Инструкция сервисная Daikin VRV устранение неисправностей Si39-302.pdf
Инструкция сервисная Daikin VRV пробный запуск Si39-302.pdf
Инструкция сервисная Daikin VRV с водяным конденсатором EEDRU12-201 03.12.pdf
Инструкция сервисная Daikin VRV-WII,VRVII особенности систем EEDU05-2 06.2005.pdf
Инструкция сервисная Daikin VRVII процедура выбора EEDU05-2 06.2005.pdf
Инструкция сервисная Daikin VRVII, VRVWII тепловой насос и рекуперация тепла.pdf
Инструкция сервисная Daikin VRVII-S кондиционеры EPCU04-14A.pd
Инструкция сервисная Daikin FMCQ-A8.pdf
Инструкция сервисная Daikin EWAD100-410E ERAD120-490E.pdf
Инструкция сервисная Daikin AHU.pdf
Инструкция сервисная Daikin RSNY.pdf
Инструкция сервисная Daikin ERQ.pdf
Инструкция сервисная Daikin K, RSNY.pdf
Инструкция сервисная Daikin RSX.pdf
Инструкция сервисная Daikin VRV G,H.pdf
Инструкция сервисная Daikin VRV G, H, K 1997.pdf
Инструкция сервисная Daikin VRV диагностический лист heat recovery.pdf
Инструкция сервисная Daikin VRV FXY.pdf
Инструкция сервисная Daikin VRV G, H, K 60Гц 1997.pdf
Инструкция сервисная Daikin VRV II R-22.pdf
Инструкция сервисная Daikin VRV INVERTER.pdf
Инструкция сервисная Daikin VRV Inverter K, Plus серии 2001.pdf
Инструкция сервисная Daikin VRV Inverter K, Plus серии 1997.pdf
Инструкция сервисная Daikin VRV K серии.pdf
Инструкция сервисная Daikin VRV K, RSN.pdf
Инструкция сервисная Daikin VRV R-22, R-410A, диагностика.pdf
Инструкция сервисная Daikin VRV RSXY, BSV.pdf
Инструкция сервисная Daikin VRV ДИАГНОСТИЧЕСКИЙ ЛИСТ HEAT PUMP.pdf
Инструкция сервисная Daikin VRV замена компрессора RXYQ5M – 48M.pdf
Инструкция сервисная Daikin VRV коды ошибок.pdf
Инструкция сервисная Daikin VRV устранение неисправностей.pdf
Инструкция сервисная Daikin VRV(IIM, IIIP, IIIS, II-SM) диагностика.pdf
Инструкция сервисная Daikin VRVII R-410A Heat Pump 50Hz.pdf
Инструкция сервисная Daikin VRV BRC, KRP, DTA, BRC.pdf

Схема Daikin VRV DCS, DTA, DMS, DAM, DCS, DPF.pdf
Схема Daikin VRV RXYQ10,12P7W1B.pdf
Схема Daikin VRV RXYQ14,16,18P7W1B.pdf
Схема Daikin VRV RXYQ5-18P.pdf
Схема Daikin VRV RXYQ8P7W1B.pdf
Схема подключения DAIKIN ZC-107DK.pdf
Схема DAIKIN ZC-107 DK,ZC-207 DK.pdf
Схема Daikin VRV RXYQ-P 3D040402G_E.pdf
Схема Daikin VRV RXYQ1012P 4D052147.pdf
Схема Daikin VRV RXYQ1012P7 2TW27256-1.pdf
Схема Daikin VRV RXYQ12-18P 3D051450.pdf
Схема Daikin VRV RXYQ14-18P 4D052572.pdf
Схема Daikin VRV RXYQ141618P7 2TW27276-1_E.pdf
Схема Daikin VRV RXYQ20-32P 3D052261.pdf
Схема Daikin VRV RXYQ34-54P 3D052262.pdf
Схема Daikin VRV RXYQ5P.pdf
Схема Daikin VRV RXYQ5P4D052145.pdf
Схема Daikin VRV RXYQ5P7 2TW27236-1.pdf
Схема Daikin VRV RXYQ810P 3D051449_E.pdf
Схема Daikin VRV RXYQ8P 4D052146.pdf
Схема Daikin VRV RXYQ8P7 2TW27246-1.pdf
Схема Daikin FXYC20-63GV1(VG).pdf
Схема Daikin XYS20-63GV1(VG).pdf
Схема Daikin FXYS125GV1(VG).pdf
Схема Daikin FXYH32GV1(VG) FXYH63GV1(VG).pdf
Схема Daikin FXYL25-40GV1(VG) FXYLM25-40GV1(VG).pdf
Схема Daikin FXYA25GV1(VG) FXYA40GV1(VG).pdf
Схема Daikin RSXY5G.pdf
Схема Daikin RSXY8G RSXY10G.pdf
Схема Daikin RSX8GY1(YAL) RSX10GY1(YAL).pdf
Схема Daikin RX8GTG RX10GTG.pdf
Схема Daikin RSEY8G RSEY10G.pdf
Схема Daikin RSXY5HJY1.pdf
Схема Daikin RSXY8HJY1 RSXY10HJY1.pdf
Схема Daikin FXYC20-125H(J)V1(VAL).pdf
Схема Daikin FXYF32-63H(J)V1(VAL).pdf
Схема Daikin FXYF80-125H(J)V1(VAL).pdf
Схема Daikin FXYK25-63H(J)V1(VAL).pdf
Схема Daikin FXYS20-63H(J)V1(VAL).pdf
Схема Daikin FXYS80-125H(J)V1(VAL).pdf
Схема Daikin FXYH32-100H(J)V1(VAL).pdf
Схема Daikin FXYA25H(J)V1(VAL) FXYA40H(J)V1(VAL).pdf
Схема Daikin FXYL(M)25-63H(J)V1(VAL).pdf
Схема Daikin RSXY5KY1.pdf
Схема Daikin RSXY8KY1 RSXY10KY1.pdf
Схема Daikin RSXY5KYAL.pdf
Схема Daikin RSXY8KYAL RSXY10KYAL.pdf
Схема Daikin RSXY5KTAL.pdf
Схема Daikin RSXY8KTAL RSXY10KTAL.pdf
Схема Daikin RSX5KY1.pdf
Схема Daikin RSX8KY1 RSX10KY1.pdf
Схема Daikin RSX5KTAL.pdf
Схема Daikin RSX8KTAL RSX10KTAL.pdf
Схема Daikin FXYC20-63KVE.pdf
Схема Daikin FXYC40-125KVE.pdf
Схема Daikin FXYF32-125KVE.pdf
Схема Daikin FXYL(M)25-63KV1(VAL).pdf
Схема Daikin FXYM200KVE FXYM250KVE.pdf
Схема Daikin FXYH32-100KVE.pdf
Схема Daikin FXYA25-63KVE.pdf
Схема Daikin FXYF32-63KGV1.pdf
Схема Daikin FXYF80-125KGV1.pdf
Схема Daikin RSNY8KTAL.pdf
Схема Daikin FXAQ20-63MAVE.pdf
Схема Daikin FXMQ40-125PVE.pdf
Схемы Daikin FXDQ20-32PBVET FXDQ40-63NBVET.pdf

Технические данные Daikin VRV кондиционеры с водяным конденсатором.pdf
Технические данные Daikin VRV-WII тепловой насос.pdf
Технические данные Daikin VRV-WIII R-410A.pdf
Технические данные Daikin VRV(II, WII).pdf
Технические данные Daikin VRVIII FXF, FXZ, FXC, FXK, FXD, FXS, FXM, FXA, FXH, FXU, FXL, FXN.pdf
Технические данные Daikin VRVIII, IIIS RXY.pdf
Технические новости Daikin VRV RSXY.pdf
Технические новости Daikin VRV, Split, SKY.pdf
Технические новости Daikin VRV, защита по питанию.pdf
Технические новости Daikin VRV, сбои электропитания.pdf

На этой странице размещены каталоги и инструкции Daikin.

Вы можете бесплатно скачать каталог и инструкцию Daikin с нашего сайта.

  • Наружный блок / ВР — блок (Основные функции) (703 Kb)
  • Установка сплит-систем (46 Kb)
  • Процедура замены датчика термистора (95 Kb)
  • Split-System Air Conditioners Sky Air Series (9470 Kb)
  • Split-System Heat Pump Room Air Conditioners (3140 Kb)
  • Service Manual (Split E-Series, Split F-Series, Sky Air F-Series) (4677 Kb)
  • Руководство по эксплуатации Sirube12-712b 2mk(x)s40-50fv1b (10194 Kb)
  • Руководство по эксплуатации Sirube12-620 2mxs52e2(3)v1b 3mxs52e2(3)v1b (6202 Kb)
  • Руководство по эксплуатации Sirube07-617 rxs25d3vmb fdxs25eavmb (2531 Kb)
  • Руководство по эксплуатации Sirube04-624a (10409 Kb)
  • Руководство по эксплуатации Sirube04-609a rxs50-71e2(3)v1b (17110 Kb)
  • Руководство по эксплуатации Siru18-729 rmks~evm (4886 Kb)
  • Руководство по эксплуатации Siru18-622 rmk(x)s-e (7084 Kb)
  • Руководство по эксплуатации Siru04-604 ftxg-rxg e-serii (4482 Kb)
  • Service Manual Sienbe12-627 2mxs40davmb 2amx40bavmb (10665 Kb)
  • Service Manual Sienbe12-626 5mxs90e7v3b 4mxs80e7v3b (4708 Kb)
  • Service Manual Sien18-622 e-series (8190 Kb)
  • Service Manual Sien04-604 ftxg-rxg e-serii (4763 Kb)
  • Service Manual Siebe18-526 rmk(x)s-d (14338 Kb)
  • Service Manual Siebe04-507-d-serii (3379 Kb)
  • Service Manual Sie-86 Inverter Pair FTK(X)-J / RK(X)-J Series (12461 Kb)
  • Service Manual Sie-81 mx-h-mk-h-series (11305 Kb)
  • Service Manual Sie-43b ma (1985 Kb)
  • Service Manual Sie-42g (3548 Kb)
  • Service Manual Sie-85 rk(x) ftk(x) h-serii (4426 Kb)
  • Service Manual Sie21-205 v-serii (6285 Kb)
  • Service Manual Sie18-201 rmx140jvmb(jzvmb) (7396 Kb)
  • Service Manual Sie18-005 jvmc(jvmt) (15816 Kb)
  • Service Manual Sie12-411 mk(x)d-bvm mk(x)d-bvma mk(x)s-bvmb(8) (12892 Kb)
  • Service Manual Sibe04-401 s-serii (10899 Kb)
  • Service Manual Sibe061121 rxg-k2v1b fvxg-k2v1b (8073 Kb)
  • Service Manual Sibe041102_A rxn25kev1b ftxn25kev1b (11757 Kb)
  • Service Manual Sibe041101 rxs20-50j2v1b (10406 Kb)
  • Service Manual Sibe041029 rx50-71g2v1b (16113 Kb)
  • Service Manual Sibe041025 rxn25-35jev1b (8796 Kb)
  • Service Manual Sibe041012 rxg-j2v1b (11019 Kb)
  • Service Manual Sibe041011 rxs60f3v1b rxs71fav1b (17094 Kb)
  • Service Manual Sibe041010 rx20-35jv1b (7014 Kb)
  • Service Manual Sibe18-821 rmxs112,140,160e8v1b (12231 Kb)
  • Service Manual Sibe12-908 2mxu40gv1b (12255 Kb)
  • Service Manual Sibe12-819 3mxs68g2v1b 4mxs68f2v1b (11543 Kb)
  • Service Manual Sibe12-818 4mxs80e7v3b 5mxs90e7v3b 5mks90e7v3b (19416 Kb)
  • Service Manual Sibe12-817 3mxs52e3v1b 3mks50e3v1b 4mks58e3v1b (12185 Kb)
  • Service Manual Sibe12-816 2mxs50g2v1b (12426 Kb)
  • Service Manual Sibe12-728 5mxs90e7v3b (18859 Kb)
  • Service Manual Sibe12-727 3mxs52e3v1b 3mks50e3v1b 4mks58e3v1b (11521 Kb)
  • Service Manual Sibe12-713 4mxs68f2v1b (13147 Kb)
  • Service Manual Sibe12-712c 2mxs50fv1b (9401 Kb)
  • Service Manual Sbe12-712 2mxs40fv1b (15299 Kb)
  • Service Manual Sibe12-625 4mxs68e2(3)v1b (11979 Kb)
  • Service Manual Sibe12-522 mxs dvmb amx dvmb (10151 Kb)
  • Service Manual Sibe07-724_B rxs25e2v1b rxs25g2v1b rxs25g2v1b9 (9298 Kb)
  • Service Manual Sibe07-618_C rxs50e2(3)v1b rxs50f2v1b rxs50g2v1b (5205 Kb)
  • Service Manual Sibe07-617 rk(x)s25-35d3vmb fdk(x)s eavmb (5082 Kb)
  • Service Manual Sibe07-516 rxs25-35d(2)vmb fdxs25-35cvmb (4843 Kb)
  • Service Manual Sibe06-708 rxs25-50f2v1b, fvxs fv1b (10562 Kb)
  • Service Manual Sibe05-722 rxs25-35e2v1b flxs25-35bavmb (6261 Kb)
  • Service Manual Sibe05-311 rxs25bvmb rx25bvmb flxs35bvmb-b-series (2823 Kb)
  • Service Manual Sibe04-809 rxg25e3v1b ftxg25ev1bw (9533 Kb)
  • Service Manual Sibe04-808_B rx(k)s-g2v1b (14859 Kb)
  • Service Manual Sibe04-704 rx25e2v1b-arx35e2v1b ftxs25cavmb-atxs25davmb (6647 Kb)
  • Service Manual Sibe04-624A (16424 Kb)
  • Service Manual Sibe04-101 rxd-j ftxd,flx,-serii (8455 Kb)
  • Service Manual Sibe01-829 ryn25-35gxv1b ry25-35gxv1 ftyn25-35gxv1b fty25-35gxv1 (4935 Kb)
  • Service Manual Sibe01-503 ryn25dv3b aty20dv2 (3923 Kb)
  • Service Manual Siau18-715 rmxs112 160ev1a (7815 Kb)
  • Service Manual Si-71A Skyair R(Y)K&F Series (9073 Kb)
  • Pocket Manual Si20-701 Service Diagnosis (3850 Kb)
  • Service Manual Sirube12-713 4mxs68f2v1b (19403 Kb)
  • Service Manual Sienbe12-620 2(3)mxs52e2(3)v1b (14902 Kb)
  • Service Manual Si18-525B rmxs112dvm (18813 Kb)
  • Service Manual Si12-714 3mxd68bvma8 4mxd80bvma (16479 Kb)
  • Service Manual Si12-619A mxs evma evlt ftxs dvma evma fvma dvmt fvlt fvlt (16408 Kb)
  • Service Manual ESIE05-07 ewap~mby ewad~mby ewwd~mby ewld~mby erap~mby ewtp~mby (19704 Kb)
  • Service Manual Sibe18-821_C rmxs-e8v1b (12260 Kb)
  • Service Manual Si12-710 2mxs50fv1b (4781 Kb)
  • Service Manual Si12-308A mxd bvmc mxd bvma mxd bvmt mxs bvmb(9) (12704 Kb)
  • Service Manual Si04-807 rx20-35gv1b (6946 Kb)
  • Service Manual Si04-703 rxs50-90fvma (13852 Kb)
  • Service Manual Si04-402A rxg cvma (7340 Kb)
  • Service Manual Si04 — 306E (6861 Kb)
  • Service Manual Si04-306 v-serii (7070 Kb)
  • Service Manual Si04-115 rk(x)-jv1nb9 ftk(x)-j (5071 Kb)
  • Service Manual ESiRU06-07 rzqs71~125b7v3b (5358 Kb)
  • Service Manual ESiEN05-04 R-410A Sky-Air Indoor (8466 Kb)
  • Service Manual ESiEN02-01A Sky Air R407C (8716 Kb)
  • Service Manual ESIE98-06A EUWA/Y5-30HB/C(Z) (5706 Kb)
  • Service Manual ESIE98-03 EUWA(*)40-120K(X) (3151 Kb)
  • Service Manual ESIE07-11 EWAP-AJ DRAFT (17544 Kb)
  • Service Manual ESIE07-10 EWWD-DJYNN (13918 Kb)
  • Service Manual ESIE07-05 ewwq-ajynn-draft (8291 Kb)
  • Service Manual ESIE07-03 EWAD-AJYNN EWAD-AJYNN/Q EWAD-AJYNN/A EWAD-AJYNN/H (9093 Kb)
  • Service Manual ESiE06-07 RZQS71~125B7V3B (4783 Kb)
  • Service Manual ESIE06-05 EWAQ080~260DAYN EWYQ080~250DAYN (19803 Kb)
  • Service Manual ESIE05-03 RZQ71~125B8V3B RZQ100~140B7W1B (12601 Kb)
  • Service Manual ESiE05-02 REQ71~125B7 (4465 Kb)
  • Service Manual ESIE05-01 RR/RQ71~125B7 (10748 Kb)
  • Service Manual ESIE04-01 RZQ71~125B7V3B (15514 Kb)
  • Service Manual ESIE02-01 Sky Air R-407C B-series (8389 Kb)
  • Service Manual ESIE03-05 Sky Air R407C RYEP~L-series (3067 Kb)
  • Service Manual ESIE03-04 R(Y)P71~125L7 Sky-Air R-407C L series (7537 Kb)
  • Service Manual SiENBE04-512A rxh20cvmb7 arxh20cvmb7 arxs20cvmb(9) ryn20cvmb7 (14980 Kb)
  • Service Manual SiBE041134 rxs20-25k2v1b (6768 Kb)
  • Service Manual SiBE04-401 rxh cvmb9 arxh cvmb9 ryn cvmb9 ftks cvmb(9)(8) atks cvmb(9) ftn cvmb9 (10830 Kb)
  • Подключение шланга для увлажнения (137 Kb)
  • Каталог — Центральная интеллектуальная система кондиционирования Hi-VRV (5604 Kb)
  • Каталог — Кондиционеры Split,Multi,Sky Air, Packaged (7302 Kb)
  • Каталог — Центральные системы кондиционирования Chiller, Fancoil, Altherma (5117 Kb)
  • Руководство по монтажу Серия R410A с раздельной установкой (3326 Kb)
  • INSTALLATION MANUAL Motorised ON/OFF valve kit (729 Kb)
  • OPERATION MANUAL MODELS FVXG25K2V1B, FVXG35K2V1B, FVXG50K2V1B (8850 Kb)
  • OPERATION MANUAL MODELS FTYN25GXV1B, FTYN35GXV1B (2495 Kb)
  • OPERATION MANUAL MODELS FTXS20G2V1, FTXS25G2V1B, FTXS35G2V1, FTXS42G2V1B, FTXS50G2V1B (3901 Kb)
  • OPERATION MANUAL MODELS FTXR28EV1B9, FTXR42EV1B9, FTXR50EV1B9 (6119 Kb)
  • Таблица кодов неисправностей (117 Kb)
  • Основа монтажа (1036 Kb)
  • OPERATION MANUAL MODEL MCK75JVM-K (3108 Kb)
  • Образец гарантийного талона (228 Kb)
  • OPERATION MANUAL MODEL MC707VM-S, MC707VM-W (2470 Kb)
  • OPERATION MANUAL MODEL MC704VM (1665 Kb)
  • OPERATION MANUAL MODELS FTXN25KEV1B, FTXN35KEV1B (1914 Kb)
  • OPERATION MANUAL MODELS FTXG25JV1BW, FTXG35JV1BW, CTXG50JV1BW, FTXG25JV1BS, FTXG35JV1BS, CTXG50JV1BS (8555 Kb)
  • Texничecкиe дaнныe настенного блока FTXG-EV1BW_FTXG-EV1BS (624 Kb)
  • OPERATION MANUAL MODELS FTX20-35GV1, FTK20-35GV1B, FTX20-35JV1B (2646 Kb)
  • Краткое руководство по очистке фильтра (393 Kb)
  • OPERATION MANUAL MODELS FDXS25-35EAVMB, FDKS25-35EAVMB, FDXS50-60CVM, DKS50-60CVMB (2674 Kb)
  • Технические данные EEDU05-7 (3203 Kb)
  • Фанкойлы (3351 Kb)
  • Диагностика неисправностей при обслуживании (3029 Kb)
  • OPERATION MANUAL MODEL MC70LVM (5314 Kb)
  • Серийный номер на корпусе (167 Kb)
  • Циркуляция хладагента (181 Kb)
  • Серийный номер на корпусе кондиционера (116 Kb)
  • Серийный номер на упаковке (174 Kb)
  • SM_SiRUBE04-624A (10409 Kb)
  • SM_SiBE04-624A (16424 Kb)
  • Инсталляция RXR28-50EV1B рус (1247 Kb)
  • Инсталляция FTXR28-50EV1B (2879 Kb)
  • ФИЛЬТРЫ _FTXR28-42-50EV1B (393 Kb)
  • Service Manual RXS25D3VMB_FDXS25EAVMB (2531 Kb)
  • Service Manual RXS20-50J2V1B (10406 Kb)
  • Service Manual RXS60F3V1B_RXS71FAV1B (17094 Kb)
  • Service Manual B_RXS25E2V1B RXS25G2V1B RXS25G2V1B9 (9298 Kb)
  • Service Manual C_RXS50E2(3)V1B RXS50F2V1B RXS50G2V1B (5205 Kb)
  • Service Manual RXS25-35D(2)VMB_FDXS25-35CVMB (4843 Kb)
  • Service Manual RXS25-50F2V1B,FVXS=FV1B (10562 Kb)
  • Service Manual RXS25-35E2V1B_FLXS25-35BAVMB (6261 Kb)
  • Service Manual RXS25BVMB_ RX25BVMB_ FLXS35BVMB B-Series (2823 Kb)
  • Service Manual B_RX(K)S-G2V1B (14859 Kb)
  • Service Manual RXS50-71F2V1B_FTXS50D2V1W(L)_FV1B (21266 Kb)
  • Service Manual С серии (10899 Kb)
  • Service Manual RXS50-90FVMA (13852 Kb)
  • Service Manual В серии (7070 Kb)
  • Service Manual RXS20-25 K2V1B (6768 Kb)
  • Service Manual RK(X)_FTK(X)_H серии (4426 Kb)
  • Service Manual RK(X)-J_FTK(X)-J (12461 Kb)
  • Service Manual RX50-71G2V1B (16113 Kb)
  • Service Manual RX20-35JV1B (7014 Kb)
  • Service Manual RX25E2V1B ARX35E2V1B_ FTXS25CAVMB ATXS25DAVMB (6647 Kb)
  • Service Manual RX20-35GV1B (6946 Kb)
  • Service Manual RK(X)-JV1NB9_FTK(X)-J (5071 Kb)
  • Разъемы для адаптеров производительности на платах (240 Kb)
  • Адаптеры при замене плат SKY VRV (125 Kb)
  • Дренажный обогрев (119 Kb)
  • БУРР (684 Kb)
  • Пособие ремонтника (50223 Kb)
  • Двигатель инверторный (прозвонка) (12 Kb)
  • Диагностика неисправностей при обслуживании (3029 Kb)
  • Коды ошибок Daikin (121 Kb)
  • Service Manual RZQS71~125B7V3B (5358 Kb)
  • Service Manual RZQ71~140D7-D9 (36571 Kb)
  • Service Manual RZQS71~125B7V3B (4783 Kb)
  • Service Manual RZQS71~125B7V3B (4783 Kb)
  • Service Manual RZQ71~125B8V3B_ RZQ100~140B7W1B (12601 Kb)
  • Service Manual RZQ71~125B7V3B (15514 Kb)
  • Service Manual RZQ71B9V3B, RZQ100~140C7V1B,RZQS71·100B7V3B, RZQS125·140C7V1B,RZQ100~140B8W1B (17217 Kb)
  • Service Manual RZQ71C7V1B, RZQ100~140C7V1B,RZQS71·100C7V1B, RZQS125·140C7V1B (17051 Kb)
  • Service Manual RR-RQ71-125B7 (10748 Kb)
  • Service Manual REQ71~125B7 (4465 Kb)
  • Циркуляция хладагента (181 Kb)
  • Service Manual JVMC(JVМТ) (15816 Kb)
  • ВР (703 Kb)
  • Service Manual RMX140JVMB(JZVMB) (7396 Kb)
  • Super-M-Plus’ 10 Замена термистора ВР (95 Kb)
  • Service Manual RMXS-E8V1B (25179 Kb)
  • Service Manual RMXS112DVM (22350 Kb)
  • Service Manual RMXS112=160EV1A (7815 Kb)
  • Service Manual RMXS112,140,160E8V1B (12231 Kb)
  • Service Manual RMK(X)S-D (14338 Kb)
  • Service Manual E-Series (8190 Kb)
  • Service Manual RMK(X)S-E (7084 Kb)
  • Service Manual RMKS~EVM (4886 Kb)
  • Si33-105_tcm135-41973 (8574 Kb)
  • SM_Si-63_rus (10223 Kb)
  • Service manual Inverter K Series (5300 Kb)
  • Service manual Basic Training Manual (9574 Kb)
  • Service manual RXYQ-M (12171 Kb)
  • Service manual ЗАМЕНА ИНВЕРТОРНОГО КОМПРЕССОРА_rus (117 Kb)
  • Service manual REYQ8-48M (14515 Kb)
  • Service manual RXYSQ-M7V3B, + ВН.БЛОКИ (4997 Kb)
  • Service manual Учебное пособие (3712 Kb)
  • Поиск кода неисправности на наружном блоке (504 Kb)
  • Сброс ошибки Е3 (155 Kb)
  • IM__REMQ8-16P8Y1B русс. (2184 Kb)
  • IM_RXYQ8-18P7W1BR1_rus (1707 Kb)
  • IM_RXYSQ~PA7V1B_rus (2155 Kb)
  • IM_RXYSQ4P8V1B (1772 Kb)
  • Si30-701 (1691 Kb)
  • SiBE37-701_B_REYQ8-48PY1B (18435 Kb)
  • SiBE37-704_A_REYQ8-48P8Y1B (19215 Kb)
  • SiRUBE37-704_REYQ8-48PY1B (8576 Kb)
  • Service manual RXYQ5-54PAY1, PAYL, PTL (13367 Kb)
  • Service manual RXYSQ4·5·6PA7Y1B, PA7V1B (9946 Kb)
  • Service manual RXYSQ4-5-6PA7Y1B, PA7V1B (3718 Kb)
  • Service manual RX(Y)MQ4·5·6PVE (5345 Kb)

Яндекс цитирования

Выбирайте готовый сайт из каталога

Table of Contents for Daikin VRV II RXYQ5MY1B:

  • SiE39-404 Introduction vii 1.1.2 Cautions Regarding Products after Repair Caution Do not repair the electrical components with wet hands. Working on the equipment with wet hands can cause an electrical shock. Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical shock. Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical shocks. Be sure to turn off the power switch and

  • SiE39-404 Troubleshooting by Indication on the Remote Controller Troubleshooting 209 2.32 “L4” Outdoor Unit: Malfunction of Inverter Radiating Fin Temperature Rise Remote Controller Display L4 Applicable Models RXYQ5~48M Method of Malfunction Detection Fin temperature is detected by the thermistor of the radiation fin. Malfunction Decision Conditions When the temperature of the inverter radiation fin increases above 89°C. Supposed Causes  Actuation of fin thermal (Actuates abo

  • SiE39-404 Field Setting Test Operation 123 3.1.5 Applicable range of Field setting ∗1 Static pressure selection Ceiling mounted cassette type Slim Ceiling mounted duct type Ceiling mounted built-in type Ceiling mounted duct type Ceiling suspended type Wall mounted type Floor standing type Concealed Floor standing type New Ceiling suspended cassette type Outdoor air processing unit Multi flow Double flow Corner type FXFQ FXZQ FXCQ FXKQ FXDQ FXSQ FXMQ FXHQ FXAQ FXLQ FXNQ FXUQ FXMQ- MF Filter sign {{{{ { { { { { { { { { Ultra long life filter si

  • SiE39-404 Troubleshooting by Indication on the Remote Controller Troubleshooting 233 Troubleshooting Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Caution Is the power supply turned on for indoor units displaying malfunction? Is transmission wiring disconnected or wired incorrectly? Is the transmission wiring with the master controller disconnected or wired incorrectly? Is the master controller’s connector for setting master controller disconnected? Set the group No. correc

  • Outdoor Unit PC Board Layout SiE39-404 118 Test Operation 2. Outdoor Unit PC Board Layout Outdoor unit PC board BS1 MODE SET RETURN TESTRESET B S2 BS3 B S4 BS5 H1P H2P H3P H4P H5P H6P H7P H8P 1 2 3 4 1 2 1 2 3 4 A B C F1F2F1F2Q1Q2 DS 1 DS2 DS 3 (V3054) (2) Set mode display (LED) (3) Mode setting switch (1) Microcomputer normal monitor HAP (4) Local setting switch Connection terminal for transmission use Switch cool/heat Indoor- Outdoor Outdoor- Outdoor Multi outdoor (1) Microcompu

  • SiE39-404 Drawings & Flow Charts v Drawings & Flow Charts A Abnormal Discharge Pipe Temperature ……………197 Abnormal Outdoor Fan Motor Signal ……………….199 Actuation of High Pressure Switch …………………..189 Actuation of Low Pressure Sensor …………………..190 Address Duplication of Central Remote Controller …………………………………..231 Address Duplicatio

  • Troubleshooting (OP: Schedule Timer) SiE39-404 246 Troubleshooting 4.4 “MA” Improper Combination of Optional Controllers for Centralized Control Remote Controller Display MA Applicable Models All models of indoor units, schedule timer Method of Malfunction Detection Malfunction Decision Conditions Supposed Causes  Improper combination of optional controllers for centralized control  More than one master controller is connected.  Defect of PC board of

  • Precautions for New Refrigerant (R410) SiE39-404 318 Precautions for New Refrigerant (R410) 1. Precautions for New Refrigerant (R410) 1.1 Outline 1.1.1 About Refrigerant R410A  Characteristics of new refrigerant, R410A 1. Performance Almost the same performance as R22 and R407C 2. Pressure Working pressure is approx. 1.4 times more than R22 and R407C. 3. Refrigerant composition Few problems in composition control, since it is a Quasi-azeotropic mixture refrigerant. H1.

  • SiE39-404 Troubleshooting by Indication on the Remote Controller Troubleshooting 199 2.22 “H7” Abnormal Outdoor Fan Motor Signal Remote Controller Display H7 Applicable Models RXYQ5~48M Method of Malfunction Detection Detection of abnormal signal from fan motor. Malfunction Decision Conditions In case of detection of abnormal signal at starting fan motor. Supposed Causes  Abnormal fan motor signal (circuit malfunction)  Broken, short or disconnection connector of fan motor connection cable  Fan Inverte

  • List of Electrical and Functional Parts SiE39-404 300 Appendix Parts Name Symbol Model Remark FXUQ71MV1 FXUQ100MV1 FXUQ125MV1 Remote Controller Wired Remote Controller BRC1A61 Option Wireless Remote Controller BRC7C528W Option Motors Fan Motor M1F AC 220~240V 50Hz 1φ45W 1φ90W Thermal protector 130°C Thermal protector 130°C : OFF 83°C : ON Drain Pump M1P AC220-240V (50Hz) AC220V (60Hz) PJV-1426 Swing Motor M1S MT8-L[3PA07572-1] AC200~240V Thermistors Thermistor (Suction Air) R1T ST86

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Daikin VRV II RXYQ5MY1B device using right now.