DAT 400

Digital Transmitter

TECHNICAL MANUAL

For Analog/Profibus/Devicenet versions

Software version PW13081

loading

Summary of Contents for Precise Instrument DAT 400

  • Page 1
    DAT 400 Digital Transmitter TECHNICAL MANUAL For Analog/Profibus/Devicenet versions Software version PW13081…
  • Page 2
    Page II…
  • Page 3: Table Of Contents

    SERIAL OUTPUT PARAMETERS …………….. Page 32 ANALOG PARAMETERS …………….. Page 36 SERIAL COMMUNICATION PROTOCOLS …………Page 38 USB CONNECTION BETWEEN DAT 400 AND PC ……….Pag. FIELDBUS PROTOCOLS ……………… Page 48 TROUBLESHOOTING ………………Page 53 GROUNDING CONNECTIONS DAT400 …………Page 54 INTRINSIC SAFETY BARRIERS …………….

  • Page 4: Precautions

    PRECAUTIONS READ this manual BEFORE operating or servicing the instrument. FOLLOW these instructions carefully. SAVE this manual for future use. CAUTION The installation and maintenance of this instrument must be allowed to qualified personnel only. Be careful when you perform inspections, testing and adjustment with the instrument on.

  • Page 5: Introduction

    INTRODUCTION The DAT 400 is a transmitter of weight to be combined with the load cells to detect the weight in every situation. The module is easy to install and can be mounted on 35 mm DIN rail. The display allows easy reading of the weight, the status of the instrument, the setting parameters and errors.

  • Page 6: Technical Features

    TECHNICAL FEATURES Power supply 24 Vdc ± 15 % Max. absorption Insulation Class II Installation category Cat. II Operating temperature -10°C ÷ +40°C (max. humidity 85% non-condensing) Storage temperature -20°C ÷ +50°C Weight display Numerical 6 red led digits and 7 segments (h 14 mm) 4 LEDs of 3 mm Keyboard 4 mechanical keys…

  • Page 7: Installation

    INSTALLATION GENERAL DATA The DAT 400 is composed of a motherboard, on which you can add the options available; the mother- board is housed in a plastic enclosure by a 35mm DIN rail. The DAT 400 should not be immersed in water, subjected to jets of water and cleaned or washed with solvents.

  • Page 8
    CONNECTIONS OF THE LOAD CELL/S The cell/s cable must not be channeled with other cables, but must follow its own path. The instrument can be connected up to a maximum of 8 load cells of 350 ohm in parallel. The supply voltage of the cells is 5 Vdc and is protected by temporary short circuit.
  • Page 9
    15 meters (EIA RS-232-C), beyond which you should take the optional RS485 interface. RS485: The serial port RS485 (2-wire) is present in the model DAT 400/ RS485. To achieve the serial connection, use a suitable shielded cable, making sure to connect the shield to one of the two ends: to pin S.GND…
  • Page 10
    For a reliable operation of the Fieldbus, should be used a line ter- mination at both ends. In the case of multiple DAT 400 instruments, use the line termination at only one instrument. For configuring the instrument, the GSD file is available (hms_1810.
  • Page 11
    DEVICENET CONNECTION (OPTIONAL) Signal Description Negative power bus CAN_L CAN low bus line SHIELD Shield CAN_L CAN_H CAN high bus line Positive power bus CAN_H To connect to the DeviceNet master, use a standard DeviceNet cable or shielded twisted-pair cable as shown on the diagram. The cable must not be channeled with power cables.
  • Page 12: Front Panel Of The Instrument

    FRONT PANEL OF THE INSTRUMENT The DAT 400 has a bright 6-digit display, 4 status LEDs and four keys. In this operating mode the display shows the weight and the LEDs indicate the status of weight and the setpoints. The set-up parameters are easily accessed and modified through the use of the three front buttons used to select, edit, confirm and save the new settings.

  • Page 13: Using The Keyboard

    USING THE KEYBOARD The instrument is programmed and controlled through the keyboard which has 4 keys, with double functions. The selection of one of the key functions is established automatically by the instrument accor- ding to the operation in progress. In general, the management of the programming menus is done by using the SET and FUN keys to scroll through the items;…

  • Page 14
    FUNCTION WHEN SETTING THE NUMERICAL VALUES It selects the next value. It selects the previous value. It confirms and store the displayed value. EXIT FROM THE SETTING MENU Press the key to return to the main menu. Press the . key again. It’s displayed “StORE?”. Press the key to return to the main menu.
  • Page 15: Info Display

    INFO DISPLAY When the instrument is switched ON, you can test the display, then in sequence you can display the identification code of the software and its version. Communication codes in the event of a request for assistance. ERRORS NOTIFICATION In the operation mode, the display can report the following error codes.

  • Page 16: Viewing, Zeroing The Weight And Self-Calibration

    VIEWING, ZEROING THE WEIGHT AND SELF-CALIBRATION After being calibrated, at the subsequent switches on, the display shows the current weight. VIEWING THE NET WEIGHT/GROSS WEIGHT Press the key to toggle between the net weight and the gross weight and vice versa. The value displayed is signaled by the LED NET (lit: net weight).

  • Page 17
    • Unstable weight (with control of the stability of the weight enabled). In this case, the reset command takes effect only if the weight stabilizes within 3 seconds or if the control of the weight stability is disabled (parameter “MOTION “ equal to zero). •…
  • Page 18
    PROGRAMMING THE WEIGHT SETPOINTS The set setpoint values are compared with the weight to drive its logic output. The comparison criterion is established in the process of set-up of the logic I / O (see relevant paragraph). To access the Setpoint setting, press the SET key and follow the instructions on the table below. …
  • Page 19
    KEYBOARD LOCK/UNLOCK FUNCTION KEYBOARD LOCK/UNLOCK A function that allows you to enable or disable the keys individually. When the keys are locked, the only way to access these settings is to press and hold pressed the PRG + 0 keys for 3 seconds. For more information on the function, refer to the block diagram above. SWITCHING THE DISPLAY OFF This function allows turning off the display after a programmable time.
  • Page 20: Setting

    SETTING GENERAL DATA All functions of the DAT 400 are activated and modified by accessing a simple setup menu, shown on page 21. All settings selected or activated remain stored even after switching off the transmitter. The DAT 400 is preconfigured with a default setting. The following pages show the values of “Default”…

  • Page 21
    DIAGRAMA DEL MENÚ FUNCTION WHEN SETTING THE PROSED VALUES It selects the next value. It selects the previous value. It confirms and store the displayed value. The menu parameters can assume values that can be set or selected. NOTE To exit and save the modified data, press multiple times the key until the display shown StorE, then press key to go back to the operating mode.
  • Page 22: Diagram Of The Menu

    DIAGRAM OF THE MENU Page 20…

  • Page 23
    QUICK SETUP MENU ENTER MENU 5 sec.  CapaC Enter Value SEns1t Enter Value Enter Value dEad L Enter Value dspd1J Select Value S1GnaL See Value CaL1br AnaLoG Enter Value StorE? 123456 EXIT MENU 60000 Page 21…
  • Page 24: Configuration Parameters

    CONFIGURATION PARAMETERS Through the setting of the parameters listed below, the theoretical Full Scale DAT 400 calibration is performed. These steps with the zero calibration described on the next page must be completed. The procedure ensures a good accuracy of the system (maximum error <1% FS) if there are no mechanical problems.

  • Page 25
    CAPACITY OF THE WEIGHING SYSTEM Programming the net capacity of the weighing system. Values lower CaL1br AnaLog Conf1G than 1/10 of CAPAC are not accepted. Values: from 1 to 500000 CapaC Enter Value Unit: the same of that displayed Default: 10000 SEns1t Enter Value FIXED CALIBRATION OF THE WEIGHING SYSTEM…
  • Page 26
    RECEIVING DATA FUNCTION UpLoad Receiving function from a serial of a file containing the setup data CaL1br AnaLog Conf1G that will be automatically set in the instrument. CapaC SENDING DATA FUNCTION dnLoad Enter Value Sending function from a serial of a file with the content of the setup SEns1t memory of the instrument.
  • Page 27: Calibration

    CALIBRATION The calibration described herein should be performed with the use of sample weights and/or product pre-weighed on a weighing system. Before proceeding with the calibration of the full scale, always perform the zero calibration. During the calibration phase, the display shows the weight intermittently with the inscription CaL. ATTENTION: At switching off the instrument without exiting the set-up menu, the programming executed is not stored.

  • Page 28
    LINEARIZATION PROCESS CaL1br Param Config When planning the sample weight, values greater than the full scale, or lower than the previous point, or when the weight is not stable, With unload are not accepted. If the entered value is accepted, it is proposed the scale next step, otherwise still the same.
  • Page 29: Weighing Parameters

    WEIGHING PARAMETERS The parameters in this menu allow the adjusment of the acquisition and updating timing of the display and the manual or automatic zeroing performed by transmitter WEIGHT FILTER F1LtEr CaL1br ParaN In-oUt This parameter adjusts the refresh speed of the display and the serial and analog output.

  • Page 30
    TRACKING THE ZERO 0 trAc CaL1br ParaN In-oUt This function allows you to perform a momentary zero calibration compensating for the temperature drift of the weight. f1LtEr At swithching off, it automatically returns to the previous zero cali- Select Value bration.
  • Page 31: Input/Output Parameters

    INPUT/OUTPUT PARAMETERS SETPOINT 1 OPERATION MODE NodE 1 ParaN In-oUt SEr1aL Select 4 operation criteria of the setpoint 1 in sequence: The relay output is active in Net Weight mode NodE 1 GROSS The relay output is active in Gross Weight mode Select Value PEAK The relay output is active in Peak mode…

  • Page 32
    SETPOINT 2 OPERATION MODE NodE 2 ParaN In-oUt SEr1aL Select 4 operation criteria of the setpoint 2 in sequence: The relay output is active in Net Weight mode NodE 1 Select Value GROSS The relay output is active in Gross Weight mode PEAK The relay output is active in Peak mode Select Value…
  • Page 33
    LOGIC INPUTS TEST PROCEDURE tEst1n ParaN In-oUt SEr1aL The display shows the inputs status. 0 = input disabled NodE 1 1= input activated. Select Value The input 1 corresponds to the 1 value on the left. Select Value Enable and disable the inputs to check the corresponding state on Select Value the display.
  • Page 34: Serial Output Parameters

    SERIAL OUTPUT PARAMETERS This menu allows you to set the serial ports COM1 and COM2 and the communication parameters. The instrument has two independent serial ports: COM1 with RS232 or RS422/RS485 interface COM2 with optional FIELDBUS interface. ENTER MENU Conf1G BAUD RATE COM1 CaL1br ParaN…

  • Page 35
    Modbus: MODBUS RTU (slave) protocol. used only if PROT-2 is StorE? 1n-oUt SEr1aL AnaLoG configured equal NONE. See details in the relevant paragraph. Selectable communication patrameters: NodE 1 baUd r f-sCaL EXIT MENU n-8-1 n-8-2 baud2r Hyst-1 NodE E-8-1 o-8-1 Default: n-8-1 t1NEr1 Prot-1…
  • Page 36
    prot-2 Select Value AddrEs Enter Value NTER MENU StorE? Conf1G CaL1br ParaN 1n-oUt SEr1aL AnaLoG COM1 SERIAL COMMUNICATION ADDRESS AddrEs IP-Add Conf1G CaL1br ParaN 1n-oUt SEr1aL AnaLoG Configuration of the address used in the transmission protocols and IP-Ad1 in the MODBUS protocol. CapaC fILtEr NodE 1…
  • Page 37
    Before starting the mapping transmission in the PC (Send key), the receiving function must be enabled on the DAT 400 by pressing the PRG key. When receiving, the display shows RECEIV, at the end of the receiving it shows END-OK. To end the process of mapping transferring, press the 0 key.
  • Page 38: Analog Parameters

    ANALOG — ANALOG OUTPUT PARAMETERS (DAT 400/A ONLY) FULL SCALE F-SCaL ConF1G SEr1aL AnaLoG It’s the weight corresponding to the full scale of the analog output that can be different from the capacity of the weighting system. f-sCaL Value to be set from 000 to 99999.

  • Page 39
    tEst Select Value ranGE Select Value ADJUSTING THE OFFSET (CALIBRATION) offsEt offsEt Measure the analog output value with a multimeter to perform the calibration of zero (0) and full scale (FS). Set Offset -Fs- Use the keys to adjust the analog output. Press and hold down the key for a rapid change.
  • Page 40: Serial Communication Protocols

    SERIAL COMMUNICATION PROTOCOLS CONTINUOUS, AUTOMATIC AND MANUAL TRANSMISSION PROTOCOL These protocols have been programmed into their programming menu. The string is transmitted as follows: <status> <net weight> <gross weight> <peak> <chksum> Where STX (start of text) = 0x02h ETX (end of text) = 0x03h EOT (end of transmission) = 0x04.

  • Page 41
    STORING THE WEIGHT Setpoint IN A PERMANENT MANNER Master: <Addr> “M” EOT DAT 400: <Addr> “M” ACK EOT In the case of communication error or otherwise unrecognized command from DAT 400, it will respond with the following string: DAT 400: <Addr> NAK EOT FIELDS DECRIPTION The double quotes enclose constant characters (observe upper and lower case);…
  • Page 42
    <status> = an ASCII character that can take the following values: “S” = stable weight “M” = weight that is not stable (moving) “O” = weight greater than the maximum capacity “E” = weight that cannot be detected. <s1>…<s2> = 6 ASCII characters of setpoint. <net weight>…
  • Page 43
    MODBUS RTU PROTOCOL The addresses listed in the tables below follow the standard address specified in the guidelines of the Modicon PI-MBUS-300. Below please find an excerpt that helps the user to communicate with the instrument. “All data addresses in Modbus messages are referenced to zero. The first occurrence of a data item is addressed as item number zero.
  • Page 44
    SUPPORTED FUNCTIONS Function Description READ COIL STATUS (Reading the state of the logic outputs) READ INPUT STATUS (Reading the state of the logic inputs) READ HOLDING REGISTERS (Reading the programmable registers) READ INPUT REGISTERS (Reading the “read only” registers”) FORCE SINGLE COIL (Writing the status of each output) PRESET SINGLE REGISTER (Writing a programmable register) FORCE MULTIPLE COILS (Multiple writing of outputs) PRESET MULTIPLE REGISTERS (Multiple writing of registers)
  • Page 45
    LIST OF THE MODBUS PROTOCOL HOLDING REGISTERS Addres Holding Register Format Note 40001 Status Register See table A 40002 Gross weight (MSB) DINT 40003 Gross weight (LSB) 40004 Net weight (MSB) DINT 40005 Net weight (LSB) 40006 Peak value (MSB) DINT 40007 Peak value (LSB)
  • Page 46
    TABLE A — REGISTER STATUS CODING Output Output Input Input Memory Lock Over- Under- Tare Zero Stable Zero Description Flag keyboard Range load load entered band weignt center WARNING: Bits 15, 14 and 7 are not managed and are always equal to 0. OPERATION Flag memory (bit 9): When modifying a register that requires saving in the E prom (see table “Data stored in memory with the command 0x020”…
  • Page 47
    Addr. of Modbus register Data stored in memory with the 0x0020 command 41001-41002 Cells capacity 41003 Cells sensitivity 41004 Weight division value 41005-41006 Tare of the system 41007-41008 System capacity 41101 Weight filter 41102 Weight stability 41103-41104 Auto-zero setpoint 41105 Zero tracking 41106 Zero band in divisions…
  • Page 48
    PRINT PROTOCOL This protocol enables the communication with a printer. The data on the printed report are the following: NET, GROSS and TARE (+ PEAK, if enabled). The print command takes place by pressing the key or by activating the remote input #2. (*) The printed report is issued only if the following conditions are met: •…
  • Page 49
    THE USB CONNECTION BETWEEN THE DAT-400 AND THE PC The hardware module installed inside the DAT-400 and allowing the instrument to be interfaced with a PC through the USB port, is named CP210x, manufactured by Silicon Laboratories. The CP210x module needs the drivers to be installed in the PC: By installing on PCs the INNOVATION 2 utility software drivers will be loaded automatically.
  • Page 50: Fieldbus Protocols

    FIELDBUS PROTOCOL FIELDBUS data exchange takes place on two separate memory areas, which are described in the tables below. WARNING: The “Input Data Area” and the “Output Data Area” are of 128 bytes To transfer the parameters of the Output Data Area to the instrument you need to enable direct access to the memory, writing the hexadecimal value 0x7FFF in the Command Register (1 word in writing) in order to avoid that the instrument resets all its variables in the case of uninitialized Output Data Area This command must be sent before the connection to inform the instrument that the parameters have…

  • Page 51
    READING EXAMPLE To read the gross weight on the DAT 400 it is needed to read the addresses from 2 to 5 of the Input Area. To read the net weightit is needed to read the addresses from 6 to 9 of the Input Area.
  • Page 52
    See table F Page 46 Set_2_Hysteresys DINT Set_2_Timer Set_2_Delay Monitor_Register WRITING EXAMPLES To write the set-up parameters following the example: In the byte 128 (Command Register) write value Hex 7FFF. This value opens the writing area of the DAT 400. Page 50…
  • Page 53
    Save the data by writing the value Hex 20 in Command Register. N.B. The DAT 400 does not accept writing of the same values already written. To perform Zero and FS Calibration it is not needed to abilitate the internal Writing Area of the DAT 400. Zero Calibration: Whit empty system put Hex 10 in Command Register (byte 128).
  • Page 54: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The weight is not detectable because The display shows the the cell is absent or incorrectly Check the connections of the cells. O-L message connected The weight cannot be shown The display shows the because it exceeds the available five hyphen in the upper digits or is greater than the capacity display…

  • Page 55: Grounding Connections Dat400

    GROUNDING CONNECTIONS DAT-400 “0 Vdc” 1: Silo. A: Load receptor-base Earthing. 2: Load cell Accessory. B: Accessory Earthing. 3: Junction Box. C: Junction Box Earthing. 4: DAT indicator. D: DAT indicator Earthing. Page 53…

  • Page 56
    Page 54…
  • Page 57: Intrinsic Safety Barriers

    OPTION 24 VOLT POWER SUPPLY INSTALLATION • Make sure the installation complies with local regulations and electrical codes. • Connect AC voltage to the terminals marked “L” and “N”. • A red LED is illuminated when the power supply is “ON”. •…

  • Page 58
    NOTES Page 56…
  • Page 59
    NOTES Page 57…

Терминал на Din рейку весовой DAT 400

(весовой преобразователь, весы терминал)

Порты: USB порт, выход RS232 или RS422/RS485,  ASCII

Протоколы или MODBUS RTU

Высокая производительность взвешивания и надежность весового терминала DAT 400.

Загрузка и выгрузка функциональных данных для программирования осуществляется  тестором Pavone Sistemi модели 1006<SP

Калибровка терминала производится путем подключения к ПК либо с помощью клавиатуры на передней панели

Высокое разрешение

6ти цифровой светодиодный дисплей 14мм

2 изолированных дискретных выхода и 2 входа

Возможность выбора цифровой фильтрации

Автоматическая установка нуля

Линейная компенсация

Функция удержания для динамических  измерений

Аналоговые выходы: 0-5V DC, 0-10V DC, 0/20mA и 4/20mA

Последовательные выходы: RS-232, RS-422 или RS-485 с

Протокол Modbus RTU

Возможна дополнительная версия с опциями: PROFIBUS или DEVICENET

Защита от радиочастотных и электромагнитных помех

Корпус ABS пластик

ВАРИАНТЫ ИСПОЛНЕНИЯ
и дополнительные опции моделей весовых терминалов:

— терминал DAT 400 at 24V DC din rail — 89076

— терминал DAT 400 at 24V DC Profibus din rail — 89076P

— терминал DAT 400 at 24V DC Devicenet din rail — 89076D

Блок питания 230V — 24V дин рейка.

Технические характеристики DAT 400

Входное напряжение: 5 V (макс. 6 тензодатчиков по 350 Ом)

Диапазон измерения: -0,5 ? 3,5 мВ / В ( -3,9 ? 3,9 мВ / В опционально)

Входная чувствительность  0,02 мкВ / деление

Линейность: <0,01 % ВПИ

Усиление, дрейф (Погрешность показаний связанной с изменение температуры): <0,001 %  / ° C от полной шкалы.

Дисплей: 6-значный , красный светодиод ( 7 сегментов ) , ч 14 мм

Состояние индикатора : 4 красных

A / D конвертер : 24 бит

Разрешение: > 16.000.000 отсчетов в измеряемом диапазоне весовых значений.

Видимое разрешение : 60,000 отображаемые на экране, по измеряемому диапазону взвешивания. нетто.

Приращение (регулируемое): x1, x2, x5

Ввод десятичных значений: 0.0 ; 0.00 ; 0.000

Фильтр: 0,1 ? 25 Гц регулируемая

Клавиатура: 4 кнопки тактильной обратной связью

Напряжение : 24 Vcc ± 15% — мощность 5 Вт

Температурный диапазон: -10 ? +50 ° C

Температура хранения: -20 / +70 ° C

Логический выход : 2 Твердотельные реле , ( максимальная нагрузка 24 В постоянного тока / 100 мА каждый )

Логический вход : 2 опто-изолированный 24 Vcc PNP ( Внешнее напряжение )

Выходы/порты : USB, RS232C о RS422/RS485 с ASCII или Modbus RTU протоколы

Дальность передачи : 15 м (RS232C ) , 1000м ( RS422 е RS485)

Протокол связи : PROFIBUS , DeviceNet (опция)

Другие коммуникации : CANopen , Modbus-Плюс и другие

Пик Функция удержания : только для динамики мероприятий

Скорость передачи данных: 2400, 9600 , 19200, 38400 , 115200 регулируемая

Аналоговый выход опционально: оптоизолированный 16 Bit натяжение: 0 ? 5/10 V (R min10 кОм ) , ток:0 / 4 ? 20 мА (R макс 300 Ом)

Соблюдение нормативных требований : EN61326-1 , EN55011 и EN55014 для EMC ; EN61010-1 для электрическая безопасность

Электрическое подключение : винтовые клеммы 5 мм

Размеры и вес : 106 х 90 х 58 мм (Д х В х Р) ; 250 г

  • Главная
     | 

  • Культиваторы и мотоблоки
     | 

  • Культиватор электрический Daewoo DAT 400E (PRC, 400 Вт, 19 см, 4,0 кг.)
     | 

  • Преимущества

Культиватор электрический Daewoo DAT 400E оснащен коваными фрезами и легко осуществляет работу на любых почвах, включая тяжелые и целину. Подходит для работы в закрытых помещениях, таких как парники или теплицы, а также для работ на наклонных поверхностях. Мощный индукционный электродвигатель обеспечивает высокую производительность и долгим сроком службы агрегата. Сошник служит для регулировки глубины вспашки.

Преимущества культиватора электрического Daewoo DAT 400E:

  • Электрический двигатель Daewoo. Двигатель специально разработан для культиваторов, обладает низким уровнем шума и обеспечивает эффективную работу с различным типом почвы.
  • Пыле- и влагозащищенный корпус.
  • Компактность и маленький вес.
  • Зубчато-винтовая трансмиссия в алюминиевом корпусе.
  • 24 фрезы особой формы.
  • Идеальный выбор для теплиц и парников.
  • 3-х летняя гарантия Daewo.
  • Скорость вращения фрез — 260 об/мин.
  • Габариты — 585х250х240 мм. (Д*Ш*В)

  • Производители
  • Daewoo
  • Культиваторы и мотоблоки Daewoo
  • Культиваторы Daewoo
  • Электрокультиваторы Daewoo
  • DAT 400E

Культиватор электрический Daewoo DAT 400E

3D

Культиватор электрический Daewoo DAT 400E (PRC, 400 Вт, 19 см, 4,0 кг.)

1/21

Технические характеристики Daewoo DAT 400E

  • Срок гарантии

    1 + 2 года

  • Тип редуктора

    Червячный

  • Вес (кг.)

    4,0

  • Мощность (Вт)

    400

  • Родина бренда

    Южная Корея

  • Страна сборки

    Китай

  • Глубина обработки (диаметр фрез) (см.)

    15,5

  • Тип культиватора

    мини-культиватор

  • Максимальная ширина вспашки (см.)

    19

  • Производитель


В наличии на складе

На складе хранения МО: ***

Сбербанк Спасибо
4%
i

Начислим 319,6 бонусов

В программе участвует любой клиент Сбербанка, который подключил свою карту к программе лояльности «СПАСИБО»

Начисление бонусов

Начисляется 4% бонусов от оплаты рублями при оплате онлайн

Доставка:

расчёт…


Москва

Габариты и вес товара не заполнены. Обратитесь к менеджеру для расчета доставки.

стоимость ориентировочная и может незначительно измениться после уточнения адреса

Картой на сайте или при получении
Наличными при получении

Скачать документацию для:

Инструкция по эксплуатации

Внешний вид, цветовая гамма, технические характеристики и комплектация могут быть изменены
производителем без уведомления, уточняйте сведения на момент покупки и оплаты. Вся информация на сайте о
товарах носит справочный характер и не является публичной офертой в соответствии с пунктом 2 статьи 437
ГК РФ.

Спасибо за заказ!

Ошибка!

В ближайшее время наш менеджер свяжется с вами.

Купить дешевле

Садовые механизмы

Артикул:

Спасибо за заказ!

Ошибка!

В ближайшее время наш менеджер свяжется с вами.

Только в магазине Садовые механизмы

3д-товары

Видео-обзоры и 3D изображения для большинства товаров.

Доставка

Доставка техники в сборе прямо на дачу.

Оплата

Заведем и продемонстрируем работу техники при доставке и ДО оплаты.

Рассрочка

Рассрочка покупки от банков Тинькофф и Сбер.

Доставка по всей России

Доставим технику по всей России транспортной компанией.

Официальный дилер

Официальный дилер лучших брендов России, Европы, Азии и США.

Торговые площади

Собственные торговые площади более 500 м2

Тестирование техники

Уникальная комната тестирования техники STIHL. Самый большой ассортимент товаров этого бренда.

Сервисный центр

Сервисный центр и заказ запчастей на бренды и технику из нашего ассортимента.

Постгарантийное обслуживание

Постгарантийное обслуживание техники.

Ошибка в описании?
Выделите ее и нажмите

Отзывы о нашей работе

Мы стремимся быть максимально удобными для Вас, обеспечить достойный уровень сервиса, и высокую компетенцию
специалистов.

Любые Ваши комментарии, предложения и пожелания не останутся без внимания.

С Вашей помощью «Садовые механизмы» станут лучше. Читайте отзывы покупателей и оценивайте качество магазина на
Яндекс.Маркете.

Читайте отзывы покупателей и оценивайте качество магазина на Яндекс.Маркете

RECEIVING DATA FUNCTION

UpLoad

Receiving function from a serial of a file containing the setup data

that will be automatically set in the instrument.

SENDING DATA FUNCTION

dnLoad

Sending function from a serial of a file with the content of the setup

memory of the instrument.

EXAMPLE OF SETTING/CALIBRATION

To weigh a tank, with empty weight of 750 kg and with a capacity

of 1000 liters, containing a product with a specific gravity of 1.33

to read the weight with a display resolution of 0.2 Kg.

Before proceeding with the configuration, make sure that the load

cells are connected properly to the unit and the tank is empty and

set the parameters.

They are used:

Nr 3 load cells with capacity of 1000 kg

Sensitivity of respectively 2.0015, 2.0008 and 1.9998 mV/V (ave-

rage value = 2.0007 mV/V)

Set the following values in the configuration parameters:

CapaC = 3000

2.0007

sEnsit

1500

t

NE

0

dEad L

0.2

dsPd1J

Make sure that the value read in the SIGNL parameter corresponds

with the calibration weight of the system according to the following

proportion:

3000:2.0007=750:X

Where X is the value of the signal expressed in mV/V corresponding

to the theoretical value of the weight of the empty tank. The value

should be about 0.5 mV/V.

Proceed to the calibration described in the following paragraph,

or you can exit the configuration menu by saving the data entered.

The instrument should indicate the value corresponding to the weight

of the empty tank (for example 756.8).

Re-access the configuration menu and enter the weight value read

in the dEad L parameter and enter the value 756.8.

Quit the configuration menu by saving the data.

For greater accuracy, prepare some sample weights or the pre-

weighed material on a certified system and calibrate as described

in the next paragraph.

Page 24

FUN

AnaLog

Conf1G

SET

CapaC

0

SET

FUN

SEns1t

0

SET

FUN

nEt

0

SET

FUN

dEad L

0

SET

FUN

dspd1J

0

SET

FUN

S1GnaL

0

SET

FUN

CoUnts

0

SET

FUN

opNodE

0

SET

FUN

UpLoad

0

SET

FUN

dnLoad

0

SET

FUN

FUN

CaL1br

SET

PRG

Enter Value

PRG

PRG

Enter Value

PRG

PRG

Enter Value

PRG

PRG

Enter Value

PRG

PRG

Select Value

PRG

PRG

Read Value

PRG

0

Read Value

PRG

0

Select Value

PRG

PRG

Receive setup data

PRG

from serial port

Transmit setup data

PRG

to serial port

Page 1: Precise DAT400 (3)

1

PrecisePrecisePrecisePrecise DAT 400 Series

Digital / Analog Transmitters

Installation & Operating Manual

(version 0.7)

9 Richmond St, Picton, ON Canada K0K 2T0Web: www.iwsystems.ca E-Mail [email protected]

Industrial Weighing Systems

Tel: 613-786-0016 Cell: 613-921-0397

Page 2: Precise DAT400 (3)

2

Technical Specifications

Input Voltage Power Consumption Isolation Category

5 volts fixed, short circuit proof 85 mA (six 350Ω load cells) 50 updates / second (no filtering) 60,000 counts 0.02 uV / count < 0.01% of full scale < 0.001% of FS / ºC 24 bits — 0.5 mV/V to + 3.5 mV/V (- 3.9 mV/V to + 3.9 mV/V optional) 0.1 Hz to 25 Hz selectable x1, x2, x5, x10, x20, x50 0.0, 0.00, 0.000 Computer interface or via front panel

Excitation Voltage Load Current Conversion Rate Resolution Sensitivity Linearity Temperature Creep A/D Converter Signal Input Range Filter Increment Size Decimal Point Calibration Methods

Environmental

Display

Performance

Operating Temperature Storage Temperature Relative Humidity

Type Status LED’s Keyboard

24 Vdc + 15% 5 Watts Class II Category II

+ 14 to + 104ºF (-10 to +40ºC) — 4 to + 122ºF (-20 to +50ºC) 85% non-condensing

6-digit red LED, 7 segment 0.55” high (4) Red LED’s (4) Keys (tactile feedback)

Power Requirements

Type Voltage Current Linearity Temperature Creep

Opto-isolated, 24 Vdc PNP (requires ext. power supply) Solid-state relays, (maximum load 24 Vdc / 100 mA each) RS-232, RS-422 or RS-485 50 feet RS-232, 3200 feet for RS-422 and RS-485 ASCII, Modbus RTU, Printer 2400, 9600, 19200, 38400, or 115200 selectable

Specifications are subject to change without notice

Analog Output (Isolated)

Inputs & Outputs

(2) Logic Inputs (2) Logic Outputs Serial Output Maximum Cable Length

Standard Protocols Baud Rate

Enclosure

Overall Dimensions Mounting Enclosure Protection (front) Weight Wiring Connections

16 bit D/A conversion 0-10 Vdc (10KΩ min load) 4-20 mA (300Ω max load) < 0.012% of full scale < 0.001% of FS / ºC

4.17” x 3.54” x 2.28” (L x H x D) DIN Rail ABS Plastic IP20 8 Ounces Terminal blocks (pitch = 0.196”)

+ 14 to + 122ºF (-10 to +50ºC) — 4 to + 158ºF (-20 to +70ºC) 85% non-condensing

Page 3: Precise DAT400 (3)

3

Installation

Mounting Install the instrument in a location where it will not be subjected to excessive heat, humidity or vibration. For best results, avoid direct sunlight on the front of the instrument. The unit should be installed at eye level so as to allow viewing the display and access to the front panel keys.

Cable Types and sizes

Use a 6 x 0.5 mm

2 shielded cable for the load

cell/s connection. Use a 3 x 0.34 mm2 shielded

cable for the RS-232 connection, and a 2 x 0.34 mm

2 shielded cable for the RS-485 connection.

Power and Wiring Considerations The instrument is powered from an external 24 Vdc source. The instrument can be operated from a computer, therefore, a “clean” power source is required for reliable operation. The incoming power should come from a source that is isolated from other process equipment. Cables carrying primary and switched power should be routed away from load cell and other signal cables to avoid electrical interference. Relays, motor starters and other inductive devices connected to the equipment must have reliable and effective arc suppression. Always connect the shield lead where indicated on the drawing, and on one end only. High voltage devices such as megohmmeters, etc. should never be used to check the wiring connections. Plastic insulating tape should not be used on load cell connections.

Environmental Considerations Heavy electrical equipment should not be installed close to the weighing equipment. Excessive vibration will affect the accuracy of the weigh system and depending on the severity can cause damage to electrical and electronic components. The atmosphere should be dust free and not contain any corrosive gasses or materials which could adversely affect the equipment.

Hazardous areas If the weighing system will be installed in a hazardous area, please refer to the drawing shown on page 42.

NOTES: WELDING on or in the vicinity of the equipment

is strictly prohibited. STATIC loads, caused by thunderstorms, must be prevented from developing by using reliable lightning conductors. ENSURE that the cooling of the equipment is not obstructed.

Page 4: Precise DAT400 (3)

4

Introduction

This manual provides general information on the installation, configuration, calibration, and

operation of the Precise 400 Series Digital / Analog Transmitters. There are two models within this series, the Model 400 which features a four-button keyboard, 6-digit Red LED display, and four status LED’s. The Model 450 is a blind unit which can only be configured and calibrated remotely via the serial port. Both models are packaged in ABS Plastic DIN-Rail mounted enclosures.

All units include the following features:

• Drives up to six 350 ohm load cells

• Supports 4 and 6 wire connections

• RS-232, RS-422, or RS-485 outputs

• (2) Logic inputs

• (2) Logic outputs (setpoints)

• Isolated analog output 4/20mA, 0-5 Vdc or 0-10Vdc output utilizing a 16 bit DAC

The Precise 400 Series Transmitters have three different modes of operation:

Operating mode

In this mode the unit displays gross weight, net weight, or peak force readings as required.

Setup mode

This mode is used for configuration and calibration of the unit.

Test mode

The test mode enables you to test the inputs, outputs, and analog output.

Front panel key functions — Operating Mode (Model 400)

The “SET” key enables you to enter values for Setpoints 1 and 2. Press the “SET” key, Set 1 appears on the display. Press the “PRG” key to view the current value. To change the current value, press the “O” key to select a digit, then use the “UP” or “DOWN” keys to increment or decrement the value. Repeat this procedure for the remaining digits, then press the “PRG” key to enter the new value. To change the value for Setpoint 2, press the “SET” key again and repeat the above procedure or press the “O” key to exit.

The “FUN” key is used to switch the unit from Gross mode to Net mode, or Peak Hold mode. To switch to Peak Hold mode, press and hold the “FUN” key until a ‘P’ appears on the display.

Operating Mode (cont’d)

The “O” key is used to zero the unit in Gross mode, tare the unit in Net mode, and reset the value to zero in Peak Hold mode.

The “PRG” key is used to send the data to the RS-232 serial port for use with a computer.

Front panel key functions — Setup Mode

In setup mode three of the front panel keys are used as directional keys to scroll through the various menus. A label on the lower half of each key identifies the direction provided by the key. The “SET” and “FUN” keys are used to navigate through the main menu and sub-menus. They are also used to increment or decrement the numerical value of a selected digit. The “O” key is used to move through certain sub-menu parameters, or to select a specific digit when numerical values are displayed. It is also used to return to the main menu from any of the sub-menus. The “PRG” key switches the unit to the “Basic Configuration” mode. It is also used to enter the sub-menus, and store parameter changes. The “PRG” key when used in conjunction with the “SET” key switches the unit to the “Complete Configuration” mode. It is also used to enter the sub-menus, and store parameter changes.

Status LED’s (Model 400 only)

There are four status LED’s on the front of the unit, one for Motion, one for Net mode, and one for each of the outputs.

Enabling/Disabling front panel keys.

In order to prevent any access to the instrument by non-authorized personnel, a procedure to lock the front panel keys is also available.

Each key can be locked individually. The 1/0 selection establish the lock/unlock condition for each single key.

See page 6 for more details.

Enabling the “blind” function

This function allows to disable the visualization of the display. A dash running counterclockwise on the display’s perimeter is displayed instead of the weight value.

See page 6 for more details.

Page 5: Precise DAT400 (3)

5

Main Power Connections

Use terminal 8 for the (+) input, and terminal 9 for the (-) input. The supply voltage must be 24 Vdc + 15%. The external power supply must have a minimum rating of 5 watts.

Transducer/s Connections

Attach cable from transducer/s to transmitter (terminals 13 through 18). If using a 4-conductor cable, (no remote sensing) jumpers must be installed between the + Excitation and + Sense leads (terminals 14 to 15) and between the — Excitation and — Sense leads (terminals 13 to 16) as shown below in Figure 1.

Logic Input Connections

Use terminal 4 for Input (1), and terminal 5 for Input (2). Terminal 6 is the common for both inputs. These are powered inputs, which require an input voltage of 24 Vdc to activate them. See Figure 1 for additional information.

Input (1) is used to zero the unit in Gross mode, tare the unit in Net mode, and reset the peak value when operating in Peak Hold mode.

Logic Input Connections (cont’d)

Input (2) functions as a “send data” command, closing the input causes the weight data to be sent to the RS-232 serial port.

Logic Output Connections

Use terminal 1 for Output (1) and terminal 2 for Output (2). Terminal 3 is the common for both outputs. The outputs utilize solid-state relays with a maximum load rating of 24 Vdc @ 100mA

Analog Output Connections

Use terminal 10 for the 4/20mA output (300 Ohm load max), or terminal 11 for a 0 to 5 Vdc or 0 to 10 Vdc output (10K Ohm load max). Terminal 12 is used as the common for either output.

Serial Output Connections

The transmitters serial port supports RS-232, RS-422 or RS-485 communications. Serial parameter selections can be found on page 19. A detailed description of the serial data formats is provided on pages 21 through 25. Wiring connections are shown on pages 26 through 27.

Figure 1

Gnd

Gnd

Not used

Not used

Txd

Rxd

+24 Vdc

0 Vdc

POWER

SUPPLY

24 Vdc

DAT

400

27 26 25 24 23 22 21 20 19

10 11 12 1

3 14 15 16 17 18

FUN

SET

PRG

O

Precise

— Tx

+ Rx

Output 2

Output 1

Input 1

Input 2

Common

Ext. p

ower supply

for Logic Inputs

(24 Vdc)

RS232

(20m max.)

Common

— Exc

+ Exc

+ Sense

— Sense

— Sig

+ Sig

+ Tx

— Rx

RS422/485

32 unit m

ax.

(1000m max.)

Voltage Out

Current Out

Common

Analog

Output

LOAD

CELL

1 2

3 4

5 6

7 8

9

Page 6: Precise DAT400 (3)

6

The weight displayed by the instrument is more than 9 divisions over the “Live” weight value (see “NET” parameter, page 13)

The load cells input signal is lower than — 0,5 (-3,9) mV/V. The load cells input signal is higher than +3,5 (+3,9) mV/V. The load cell input signal is missing

O — L

When no programming procedures are in progress, the display shows the weight value.

In some particular conditions the following MESSAGES are displayed:

The values in brackets refer to the instruments having load cells input signal range from — 3,9 to + 3,9 mV/V (optional)

ON

( PRG )

( PRG )

LOCK

O (

(

( PRG ) + (press and hold)

( O

(

0 0 0 0

( PRG )

( PRG )

O

O PRG

Front panel keys

Perform the selection 0/1 of the blinking digit

Move the blinking digit to the right

BLIND

OFF

( PRG ) ( O

(

00

( PRG )

O

Perform the selection 0/1 of the blinking digit

Move the blinking digit to the right

Time programming (01 to 99 secs.) Default = 00

END

The “Blind” function has been enabled

Locking the front panel keys and enabling the “blind” function

In order to prevent any access to the instrument by non-authorized personnel, a procedure to lock the front panel keys is available. Each key can be locked individually. The 1/0 selection establish the lock/unlock condition for each single key.

The “blind” function allows to disable the visualization of the display. A dash running counterclockwise on the display’s perimeter is displayed instead of the weight value once the programmed time (01 to 99 sec.) expires. When the instrument is in “blind” mode all its functions are active.

Press and hold the “PRG” and “O” keys. The “O” key must be pressed after the “PRG” key. Release both keys when the message LOCK appears on the display.

Default = OFF

Page 7: Precise DAT400 (3)

7

Configuration Methods

The Precise 400 Series Digital / Analog Transmitters can be configured by using the front panel keys (Model 400) to navigate through a series of menus, or by sending configuration and calibration data to the RS-232 port with

INOVATION an MS Windows based program

included with the unit. INOVATION simplifies the configuration and calibration procedure.

Configuration Procedures

There are two procedures available for setup of

the Precise 400 Series Transmitters, “Basic Configuration” or “Complete Configuration”.

The “Basic Configuration” procedure allows you to change selective parameters, whereas, the “Complete Configuration” procedure allows you to change all of the parameters.

For example, if the transmitter requires calibration only, the “Basic Configuration” procedure is recommended.

The following pages provide a detailed explanation of both configuration procedures.

Basic Configuration via the Front Panel

To perform a “Basic Configuration”, press and hold the “PRG” key until the display shows CAPAC. Use either the “UP” or “DOWN” keys to navigate through the eight basic configuration sub-menus shown below.

Basic Configuration (cont’d)

To set one of the following parameters, CAPAC, SENSIT, NET, DEAD L, DSPDIV, or ANALOG, press the “PRG” key to view the default or previously selected value for that parameter. To change the value, press the “O” key to select a digit, then use the “UP” or “DOWN” keys to increment or decrement the value of the selected digit. When the desired value appears on the display, press the “PRG” key to store the new value. Press either the “UP” or “DOWN” keys to move to the next parameter.

The SIGNAL parameter enables you to view the actual input signal from the transducer/s. Press the “O” key to move to the next parameter.

The CALIBR parameter is used to calibrate the transmitter. The unit can be calibrated using either the data sheet or dead load procedure.

The data sheet calibration procedure allows the transmitter to be calibrated without a transducer simulator or test weights. This procedure is based on the capacity and certified, full scale mV/V output (sensitivity) of the transducer/s.

To perform a data sheet calibration, enter the total scale capacity, sensitivity, net weight, dead load weight, and display resolution, then press the “O” key. The display will indicate STORE ?, press the “PRG” key to save the changes and return to the operating mode.

See page 9 for a detailed explanation of the calibration procedure using test weights. The ANALOG parameter is used to enter the full scale weight value that you want the analog output to represent. The default is net weight value.

To exit from the setup procedure, press the “O” key when any one of the following parameters are displayed CAPAC, SENSIT, … ANALOG. The display will indicate STORE ?, press the “PRG” key to save the changes and return to the operating mode.

Display Sub-menu Functions

CAPAC Total capacity of transducer/s

SENSIT Rated output of the transducer/s

NET Net (live) weight value

DEAD L Dead load weight value

DSPDIV Increment size (resolution)

SIGNAL Transducer/s input signal (view)

CALIBR Calibration procedure

ANALOG Full scale value for analog output

Page 8: Precise DAT400 (3)

8

Basic Configuration Menu

Place the unit in “Basic Configuration” mode by pressing and holding the “PRG” key until the display shows CAPAC. Use either the “UP” or “DOWN” keys to scroll through the eight basic configuration menus shown above. To set one of the following parameters, CAPAC, SENSIT, NET, DEAD L, DSPDIV, or ANALOG, press the “PRG” key to view the default or previously selected value for that parameter. To change the value, press the “O” key to select a digit,

then use the “UP” or “DOWN” keys to increment or decrement the value of the selected digit. Press the “PRG” key to enter the new value, then press either the “UP” or “DOWN” keys to move to the next parameter. To exit the setup procedure, press the “O” key when any one of the sub-menu parameters are displayed. The display will indicate STORE ?, press the “PRG” key to save the changes and return to the operating mode.

Enter total scale capacity

Enter transducer/s sensitivity

Enter “LIVE”

weight value

Enter “Dead Load” weight value

Select display divisions 0.001 — 50

View input signal value

mV/V

Enter FS value for analog out

( PRG )

( PRG )

( PRG )

( PRG )

O (

(

( PRG )

( PRG ) (keep pressed)

See calib. procedure on next page

( PRG )

( PRG )

STORE ?

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

QUIT

* (

(

SIGNAL

DSPDIV

DEAD L

SENSIT

CAPAC

NET

CALIBR

ANALOG

Page 9: Precise DAT400 (3)

9

Basic Configuration Menu (cont’d)

The Precise 400 Series Transmitters can be calibrated via the front panel keys (Model 400),

or with the INOVATION configuration utility. Both methods consist of the following steps.

• Zero calibration

• Apply a known load (test weight)

• Edit weight value

• Span calibration

• Optional linearization (See page 15)

2-point calibration via the front panel keys

To calibrate the transmitter with the front panel keys, proceed as follows: 1. With the unit in “Basic Configuration” mode and the message “CALIBR” displayed, press the “PRG” key (CAL will be blinking on the display). 2. With the system unloaded, press the “O” key to perform the ZERO calibration.

3. Apply a known load not less than 10% of the net weight value and press the “UP” key.

4. Enter the actual weight value using the “O” key to select each digit, then use the “UP” or “DOWN” keys to increment or decrement the value of the selected digit.

5. Press the “PRG” key to enter the setting (CAL will be blinking on the display).

6. Press the “PRG” key, (the display indicates CALIBR), press either the “UP” or “DOWN” keys to move to the next parameter.

7. If no additional parameter changes are required, press the “O” key (the display indicates STORE ?), press the “PRG” key to save the changes and return to the operating mode. Should it be necessary to erase either of the previous calibration entries, proceed as follows:

When the message CAL is blinking on the display, to erase the zero calibration, press and hold the “FUN” key, and then press the “O” key. Release both keys, the previous zero calibration entry has been erased. To erase the span calibration, press and hold the “FUN” key, and then press the “SET” key. Release both keys, the previous span calibration entry has been erased. End the procedure as described above (points 6 and 7).

NOTE: Input signal from the transducer/s must be stable when entering the zero and span values.

CAL

WT-VALUE

CAL

Sets ZERO calibration

Enter the actual weight value (SPAN)

Back to

“CALIBR” (Main menu)

( PRG )

( PRG )

Cont’d from the previous

page

NOTE: In order to ensure greater stability during the calibration procedure, the digital filter increases to the maximum value automatically (value 9), therefore the weight indication updates very slowly at this stage. Once the calibration procedure has been completed, the digital filter will return to the pre-vious value automatically.

O (

(

* (

(

( PRG )

Page 10: Precise DAT400 (3)

10

Configuration using INOVATION

To configure the Precise 400 Series Digital /

Analog Transmitters with the INOVATION program, proceed as follows:

1. Install INOVATION on an IBM-compatible computer running Windows 95, 98, Me or XP.

2. Minimum system requirements are 8MB of extended memory and at least 5MB of available hard drive space.

3. Remove power from both units, and connect the PC’s serial port to the RS-232 terminals on the transmitter. Refer to page 27 for wiring.

4. Apply power to the PC and the transmitter,

then start the INOVATION program.

5. Switch the transmitter into remote mode by removing the upper left cover and moving jumper (J1) to the remote control position as shown below. The Model 400 can also be switched into remote mode by going into complete configuration and then selecting ‘Remote’ from the serial menu. See page 19.

Pins 1 — 2 = Remote Control Pins 2 — 3 = Default Setting

When viewing either model from a computer, the current weight value will be displayed under the icon representing the unit being configured. If ERROR appears under the transmitters icon, re-check all of the wiring connections, verify that the unit is in remote mode, and make sure the icon being displayed matches the address of the transmitter to be configured. Double-clicking on the transmitters icon will bring

you to the INOVATION Main Setup Screen.

Display Main Menu Functions

CONFIG Parameters for total scale capacity, transducer sensitivity, net and dead load weight values, display divisions.

CALIBR Zero and full scale calibration.

PARAM Parameters for digital filtering, motion, auto zero and zero tracking

IN-OUT Operating mode selection for outputs, and input and output test.

SERIAL Serial output configuration.

ANALOG Analog output configuration and cali-bration.

Complete Configuration via the Front Panel(Model 400) In order to perform a complete configuration, the unit must be placed in setup mode. To enter the setup mode, press and hold the “PRG” and SET” keys on the front of the unit. The “SET” key must be pressed after the “PRG” key. Release both keys when the word CONFIG is shown on the display. The CONFIG menu is the first of six main menus used to completely configure the instrument. Use either the “UP” or “DOWN” keys to navigate through the six main menus shown below.

Press the “PRG” key to move down to the sub-menu or parameter desired. Press the “PRG” key to view the default or previously selected value for that parameter. To change a parameter, press either the “UP” or “DOWN” keys to view the choices for that parameter. When the desired selection appears on the display, press the “PRG” key to enter the selection and move to the next parameter. To edit numerical values, use the “O” key to select the digit, then use either the “UP” or “DOWN” keys to increment or decrement the value of the selected digit. Once the value has been entered, press the “PRG” key to store the value and move to the next parameters. Press the “0” key until the display indicates STORE ?, press the “PRG” key to save the changes and return to the operating mode.

DAT 400

1 2 3

1 9

Precise

Page 11: Precise DAT400 (3)

11

Configuration using INOVATION (cont’d)

On this screen you can switch the display among net, gross and peak reading, set the se-rial address, enter values for the two setpoints, check the two logic inputs status and the software release of the instrument.

Click on the SETUP button, seven file folders will appear on the lower half of the screen. The first file folder labeled “Parameters” will be open.

The top section in this folder is for entering the total scale capacity, sensitivity, net weight, and dead load weight values (required parameters for performing a data sheet calibration)

The data sheet calibration procedure allows the transmitter to be calibrated without a transducer simulator or test weights. This procedure is based on the capacity and certified, full scale mV/V output (sensitivity) of the transducer/s.

To perform a data sheet calibration, enter the above values, then click on the SEND button for that group of parameters.

The next section in this file folder is used to select the display resolution. It consists of a drop down menu and a SEND button.

The Precise units allow to count by 1’s up to 60,000 counts, Yet, for values greater than 10,000, the units automatically select a lower resolution to ensure greater stability. After se-lecting the desired resolution, press the SEND button for this parameter. Do not press any of the other SEND buttons in this folder or the unit will revert back to a default setting of x2, x5, etc.

Changes to the display resolution should only be done after the unit has already been calibrated using the data sheet or dead load procedure.

The bottom parameter selection in this file folder is labeled “Operating Mode”. It enables the unit to retain the mode of operation in the event of a power loss. When the power is re-applied, the transmitter automatically returns to the mode that it was operating in prior to the power loss.

Changes to the Operating Mode cause an automatic power off — power on sequence of the instrument when the configuration will be saved. This allows the new Operating Mode to take effect.

The second file folder enables you to calibrate the unit with a transducer simulator or actual weight, (recommended method of calibration).

Inside this 2nd file folder, once the zero calibration has been performed, the program asks the operator if the new zero has to modify the “Data sheet” calibration.

Figure 2

If the operator answers “Yes”, the “Dead load” value inside the first file folder will change automatically according to the new zero. If the operator answers “No”, the “Dead load” value inside the first file folder will remain set to the previous value.

The third file folder contains the parameter selections for digital filtering, zero tracking, etc.

The fourth file folder contains the parameter selections for configuring the inputs and outputs

The fifth file folder contains the parameter selections for the serial output.

The sixth folder contains the parameter selections for the analog output,

The seventh folder provides a means for testing the outputs and analog output

The Main Setup Screen and file folders 1 through 6 all have SEND buttons on them for downloading the various parameter changes.

When configuration and calibration has been completed, the data can be saved on a PC or floppy disk or downloaded (sent) to the transmitter. This method of configuring and calibrating is very beneficial when several transmitters with similar configurations are being set up, or when a transmitter has to be replaced.

To exit INOVATION, click on the Exit Setup icon. Now click on Option in the upper left corner of the screen, from the drop down menu select EXIT, a “Save Changes” window will appear, click on OK. This will return you to the Configuration Utility Screen, click on QUIT. Figure 2 shows an example of one of the

INOVATION configuration screens.

Page 12: Precise DAT400 (3)

12

Figure 2.1

The Inovation software also allows the operator to create new configurations,

save new files and open existing files wi-thout having any instrument connec-ted to the computer.

Thanks to this feature, the download of a given configuration to the instrument can be performed at any time.

To perform the operation mentioned above click on the “Edit” menu at the left end upper corner (See figure 2.1), then enable the function “Edit Configuration Offline”. The message “Edit” will appear on the display, showing this particular condition.

Another useful function concern the possibility to print out a report in which all the parameters of a given configuration are included. The “Print” command can be performed by clicking on “Print Configuration”.

Besides, the command “Report Notes” allows the operator to include a heading in the report, in order to identify the plant, the customer name or any other useful information.

An example of a printed report is given on the right side of this page:

PRINT CONFIGURATION

Date 12/01/2004 Test Procedure for DAT instruments

Status Instrument

Device address 2

Setpoint 1 value 1500

Setpoint 2 value 3500

Input 1 status 0

Input 2 status 0

Instrument software version 0.4

Parameters

Total capacity of transducers 10000

Full scale output value (mV/V) 2.0000

Net weight (value) 8000

Dead load (value) 1500

Display resolution 1

Input signal 0.599

Internal counts (Reference only) 155729

Operating mode Net

Filters / z-track

Digital filter value (0 to 9: 0 = no filter; 9 = max filter; default 5) 5

Motion band value (0 to 4: 0 = minimum; 4 = maximum; default 2) 1

Auto zero range setting at power up (0 to 10.0% of net weight: 0 = disble) 0.0

Zero tracking (0 to 4: default 2) 2

Output config. Out 1

Operating mode Net

Contact status below setpoint value N. Open

Positive / Negative weight comparison Positive

Immediate activation / activation after stabilization Immediate

Hysteresis (default 2) 2

Setpoint activation time length (in 1/10 sec.) (0 = disable) 0

Time delay for activating setpoint (in 1/10 sec.) (0 = disable) 0

Output config. Out 2

Operating mode Gross

Contact status below setpoint value N. Closed

Positive / Negative weight comparison Positive

Immediate activation / activation after stabilization Immediate

Hysteresis (default 2) 50

Setpoint activation time length (in 1/10 sec.) (0 = disable) 0

Time delay for activating setpoint (in 1/10 sec.) (0 = disable) 0

Serial

Baud Rate (default 9600) 9600

Serial port mode (default Continuous transmission) Slave

Serial address (ID Code) (from 01 to 32) 2

Response delay (Demand or Modbus mode) (in 1/100 sec. Max 1 sec.) 25

Data Format (N-8-2 / E-8-1 / O-8-1 for MODBUS mode) N-8-1

Com2 Protocol (None for MODBUS mode) None

Com2 Address (Profibus/DeviceNet Address from 1 to 126) 001

Com2 Baud Rate (Only DeviceNet) 250

Ana. Output

Full scale value (default = Net weight value) 8000

Analog output source (Net Gross Peak H) Net

Analog output selection 0-20mA

No load zero input value 0

Page 13: Precise DAT400 (3)

13

Complete Configuration Menu

Place the unit in complete configuration mode by pressing and holding the “PRG” and SET” keys on the front of the unit. The “SET” key must be pressed after the “PRG” key. Release both keys when CONFIG is dis-played. Press the “PRG” key to enter the sub-menu, then use either the “UP” or “DOWN” keys to se-lect one of the sub-menu parameters. Press the “PRG” key to view the default or previously se-lected value for that parameter.

To change the value, press the “O” key to select a digit, then use the “UP” or “DOWN” keys to increment or decrement the value of the selected digit. Press the “PRG” key to enter the new value, then press either the “UP” or “DOWN” keys to move to the next sub-menu parameter or press the “O” key to return to the main menu. To exit the configuration procedure, return to the main menu and press the “O” key, (the display will indicate STORE ?), press the “PRG” key to save the changes and return to the operating mode.

CALIBR PARAM IN-OUT SERIAL ANALOG

SENSIT

NET

DEAD L

SIGNAL

Operating mode @ power up

( PRG )

( PRG )

CONFIG

Enter total scale capacity

( PRG ) ( PRG )

Enter transducer/s sensitivity

( PRG ) ( PRG )

Enter “LIVE”

weight value ( PRG ) ( PRG )

Enter “Dead Load” weight value

( PRG ) ( PRG )

Select display divisions 0.001 — 50

( PRG ) ( PRG ) DSPDIV

View input signal value

mV/V O (

(

( PRG )

View the Raw

A/D counts O (

(

( PRG ) COUNTS

GROSS

OPMODE

NET PEAK H

( PRG )

CAPAC O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

Page 14: Precise DAT400 (3)

14

Complete Configuration Menu (cont’d)

NOTE: Prior to calibration, the transmitter must be configured, thus giving it a set of operating parameters. The unit can be calibrated using the 2-point method or the optional multi-point (linearity compensation) method. See page 15 for a detailed description of the multi-point calibration procedure.

2-Point calibration via the front panel keys

To calibrate the transmitter using the front panel keys, proceed as follows: 1. With the unit in “Complete Configuration” mode, press either the “UP” or “DOWN” keys until CALIBR is shown on the display. 2. Press the “PRG” key (CAL will be blinking on the display). 3. With the system unloaded, press the “O” key. 4. Apply a known weight not less than 10% of the net weight value and press the “UP” key.

5. Enter the actual weight value using the “O” key to select each digit, then use the “UP” or “DOWN” keys to increment or decrement the value of the digit. Press the “PRG” key to enter the setting (CAL will be blinking on the display). 6. Press the “PRG” key, (the display indicates CALIBR), press either the “UP” or “DOWN keys to move to the next parameter. 7. If no additional parameter changes are required, press the “O” key (the display indicates STORE ?), press the “PRG” key to save the changes and return to the operating mode. Should it be necessary to erase either of the previous calibration entries, proceed as follows: To erase the zero calibration, press and hold the “FUN” key, and then press the “O” key. Release both keys, the previous zero calibration entry has been erased. To erase the span calibration, press and hold the “FUN” key, and then press the “SET” key. Release both keys, the previous span calibration entry has been erased.

PARAM IN-OUT SERIAL ANALOG CONFIG

NOTE: Input signal from the transducer/s must be stable when entering the zero and span values.

CAL

WT-VALUE

CAL

Sets ZERO calibration

Enter the actual weight value (SPAN)

( PRG )

NOTE: In order to ensure greater stability during the calibration procedure, the digital filter increases to the maximum value automatically (value 9), therefore the weight indication updates very slowly at this stage. Once the calibration procedure has been completed, the digital filter will return to the pre-vious value automatically.

O (

(

( PRG )

( PRG )

CALIBR

( PRG )

Page 15: Precise DAT400 (3)

15

Complete Configuration Menu (cont’d)

The Model 400 features a 10-point linearization option (available only with the front panel keys). Any number of points up to 10 may be used, however, the last point must always be the full scale value of the weighing system. Example: A one point linearization correction would require a total of two points, one point within the range, and one point for full scale.

Prior to performing the linearization correction, at least the zero of the unit must have already been calibrated, while the full scale value is not mandatory. The unit must be in CALIBR mode, and you should have known weights available equal to the points being set.

Multi-point Calibration via Front Panel Keys

1. With the unit in either “Basic or Complete Configuration” mode, press the “PRG” key (CAL will be blinking on the display). 2. Press and hold the “SET” key until Lin P1 is blinking on the display. 3. Apply a known weight for the first linearization point, and press the “PRG” key. 4. Enter the actual weight value using the “O” key to select each digit, then use the “UP” and “DOWN” keys to increment or decrement the value of the selected digit.

5. Press the “PRG” key. The unit will increment to the next linearization point (Lin P2). 6. Repeat steps 3 through 5 for additional points. 7. If all 10 points will be linearized, follow the 1st. procedure. For linearization correction using less than 10 points, follow the 2nd. procedure.

1st Procedure (10-point linearization) 7a. Enter the weight value for linearization point Lin P9, and press the “PRG” key (CAL will be blinking on the display). Press the “PRG” key again, (the display indicates CALIBR). 7b. Press the “O” key (the display will indicate STORE ?), press the “PRG” to save the changes and return to the operating mode.

2nd. Procedure (less than 10-point linearization) 7a. The last linearization point must be the full scale value. Press the “O” key, (CAL will be blinking on the display). 7b. Press the “PRG” key (the display will show CALIBR). Press the “O” key (the display will indicate STORE ?). 7c. Press the “PRG” key to save the changes and return to the operating mode.

Lin P1

Sets tare value Point 0

Lin P9

Display and edit test

weight value

NOTE: Input signal from the transducer/s must be stable when entering the linearization correction point values.

CAL

( PRG )

CALIBR

( SET ) (Keep pressed)

Apply a known weight on the

scale

( PRG )

WT VALUE ( PRG )

Lin P2….P8 ( PRG )

CAL ( PRG )

O (

(

Page 16: Precise DAT400 (3)

16

Complete Configuration Menu (cont’d)

1. With the unit in “Complete Configuration” mode, press either the “UP” or “DOWN” keys until PARAM is shown on the display. 2. Press the “PRG” key to enter the sub-menu, then use either the “UP” or “DOWN” keys to select one of the sub-menu parameters. 3. Press the “PRG” key to view the default or previously selected value for that parameter. 4. To change the value, press the “O” key to select a digit, then use the “UP” or “DOWN” keys to increment or decrement the value of the selected digit.

5. Press the “PRG” key to enter the new value, then press either the “UP” or “DOWN” keys to move to the next sub-menu parameter or press the “O” key to return to the main menu. 6. To exit the configuration procedure, return to the main menu and press the “O” key, (the display indicates STORE ?), press the “PRG” key to save the changes and return to the operating mode.

See Table 2 on page 28 for a detailed explanation of the “PARAM” parameter selections

PARAM IN-OUT SERIAL CONFIG CALIBR

FILTER

MOTION

AUTO 0

0 TRAC

Enter value 0 to 4

Default = 2

Enter value 0 to 9

Default = 5

Enter value 0.0 to 10.0% 0 = Disabled

Enter value 0 to 4

Default = 2

( PRG )

( PRG ) ( PRG )

( PRG ) ( PRG )

( PRG ) ( PRG )

( PRG ) ( PRG )

O (

(

O (

(

O (

(

O (

(

0 BAND

Enter value 0 to 200

Default = 100 ( PRG ) ( PRG ) O (

(

Page 17: Precise DAT400 (3)

17

Complete Configuration Menu (cont’d)

MODE 1

IN-OUT SERIAL ANALOG CONFIG CALIBR PARAM

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

NET

GROSS

PEAK H

( PRG )

( PRG )

N.O.

N.C.

( PRG )

( PRG ) NEG.

POS.

NORMAL

STABLE

HYST 1 ( PRG ) ( PRG ) See notes on page 30 Default = 2

TIMER 1

Enter value 0.00 — 100.0 Default = 0

( PRG ) ( PRG )

DELAY 1

Enter value 0.00 — 100.0 Default = 0

( PRG ) ( PRG )

HYST 2 ( PRG ) ( PRG ) See notes on page 30 Default = 2

TIMER 2

Enter value 0.00 — 100.0 Default = 0

( PRG ) ( PRG )

MODE 2

Refer to procedure for MODE 1

( PRG )

DELAY 2

Enter value 0.00 — 100.0 Default = 0

( PRG ) ( PRG )

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

Continued on the following page

Page 18: Precise DAT400 (3)

18

Complete Configuration Menu (cont’d)

TEST OUT

See Table 1

Display OUTPUT 1 (status)

OUTPUT 2 (status)

OUT 00 OFF OFF

OUT 10 ON OFF

OUT 02 OFF ON

OUT 12 ON ON

Table 1

See Table 6 on page 30 for a detailed explanation of the “IN — OUT” parameter selections

IN 0 0

Closing Input 2 = 02

Closing Input 1 = 10

O (

(

( PRG )

Cont,d from the previous page

O (

(

TEST IN

( PRG )

OUT 00

OUT 10

OUT 02

OUT 12

O (

(

O (

(

O (

(

O (

(

O (

(

Page 19: Precise DAT400 (3)

19

**

DEVNET

CONFIG CALIBR PARAM IN-OUT

BAUD R 2400

9600

19200

38400

PROT-1

ADDRES

DELAY

CONTIN

DEMAND

AUTOM

SLAVE

MODBUS

BCD

NONE

O (

(

See Tables 3 through 5 for a detailed explanation of the “SERIAL” parameter selections

REM-CO REMOTE OPERATING

MODE

115200

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

Enter value 01 — 32 Max # 32

Enter value 0.00 — 1.00 Max 1 sec.

( PRG ) ( PRG )

( PRG ) ( PRG )

( PRG )

O (

(

O (

(

O (

(

O (

(

O (

(

PROT-2

NONE

( PRG )

( PRG )

( PRG )

( PRG ) O (

(

PROFIB

PR-ADD Enter value 001 — 126 ( PRG ) ( PRG ) O (

(

*

Use the “PROT-2” ONLY when the instrument is equipped with the Profibus-DP or DeviceNet option cards. Otherwise do not enter into this menu.

“BAUD1R”, “BAUD2R” and “DN-ADD” come up on the display only if the “PROT-2” menu has been set as “DEVNET”.

** When the “PROT-2” menu is set as “PROFIB” or “DEVNET”, the “ANALOG” menu will be automatically disabled. Therefore the access to the “ANALOG” menu is possible only when the “PROT-2” has been set as “NONE”.

* DN-ADD

* BAUD1R

( PRG )

n 8 2

E 8 1

o 8 1

( PRG )

( PRG )

( PRG )

SERIAL ANALOG

( PRG )

( PRG ) BAUD2R

n 8 1

n 8 2

E 8 1

o 8 1

n 7 2

E 7 1

E 7 2

o 7 1

DATA F ( PRG ) O (

( ( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

PRINT

( PRG )

Page 20: Precise DAT400 (3)

20

Complete Configuration Menu (cont’d)

1. With the unit in “Complete Configuration” mode, press either the “UP” or “DOWN” keys until ANALOG is shown on the display.

2. Press the “PRG” key to enter the sub-menu, then use either the “UP” or “DOWN” keys to select one of the sub-menu parameters.

3. Press the “PRG” key to view the default or previously selected value for that parameter.

4. To change a parameter, press either the “UP” or “DOWN” keys to view the choices for that parameter. When the desired selection appears on the display, press the “PRG” key to enter the selection and move to the next parameter.

5. To edit numerical values, use the “O” key to select the digit, then use either the “UP” or “DOWN” keys to increment or decrement the value of the selected digit.

6. Press the “PRG” key to enter the new value, then press either the “UP” or “DOWN” keys to move to the next sub-menu parameter or press the “O” key to return to the main menu.

The “ANZERO” parameter is a negative weight value to which the zero offset of the analog out-put can be referred.

Example: If the selected range is 4/20 mA and the “ANZERO” value is “10”, the analog output value will be 4 mA when the weight will be “–10”

ANALOG CONFIG CALIBR PARAM IN-OUT SERIAL

F-SCAL

MODE

TEST

OFFSET

Enter weight value

( PRG )

Enter span value ( PRG ) ( PRG )

( PRG )

( PRG )

( PRG )

( PRG )

NET

GROSS

PEAK H ANZERO ( PRG ) ( PRG )

( PRG )

OUT 0

OUT 100

O (

(

O (

( RANGE

( PRG )

( PRG )

( PRG )

0-20 mA

4-20 mA

0-10 V

( PRG )

( PRG ) 0-5 V

( PRG )

( PRG )

— 0 —

— FS —

( PRG )

Adjust value with UP & DOWN keys

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

O (

(

Page 21: Precise DAT400 (3)

21

Baud Rates

2400, 9600, 19200, 38400, and 115200

Data Formats

All serial characters are in ASCII format, and consist of the following. 1 Start Bit, 7 or 8 Data Bits, 1 or 2 Stop Bit, Parity No, Even or Odd. The above data depend on the selection made in the “SERIAL” menu (see Table 3 on page 28)

Transmission of the serial data can be initiated in several ways as described below.

Automatic mode

The “Automatic” mode is used to interface with printers or other data acquisition devices. The serial data is transmitted automatically, upon stabilization whenever the weight value has increased or decreased more than 20 divisions. This function is not performable when the “MOTION” parameter is set to 0 (weight stability check disabled).

Continuous mode

The “Continuous” mode is used to interface with computers, remote displays, or other types of devices that require constant data updating.

Demand mode

The “Demand” mode is used to interface with printers and requires a manual print command from the front panel keys (Model 400) or a remote contact closure to initiate the output. In the above modes, the transmitter sends serial data using the format shown below:

Serial Communication

STX <status> <net weight> <gross weight> <peak value> ETX <chksum> EOT

STX (start of text) = 02h ETX (end of text) = 03h EOT (end of transmission) = 04h

NOTE: The brackets “<“ “>“ are not sent, they are only shown for clarification. The checksum control value is obtained by performing the XOR operation. It is expressed with 2 Hexadecimal digits. Example: 25 = 1D The result of the above calculation equals 1 character, which can be a numerical value of 0 to 9 or A to F (Hexadecimal)

“S” “M” “O” “E”

= 1 ASCII character consisting of the following: = Stable = Motion = Overload = Error = 6 ASCII characters = 6 ASCII characters = 6 ASCII characters = 2 ASCII characters (STX & ETX are not included in the checksum)

<status>

<net weight> <gross weight > <peak value> <checksum>

Page 22: Precise DAT400 (3)

22

Serial Communication (cont’d)

After receiving the request, the transmitter responds with the following data string.

Slave mode

The slave mode is used for interfacing with distributed control systems (DCS) or programmable logic controllers (PLC). This mode requires a data request from the master to initiate the output.

In this mode the host sends serial data to the transmitter using the formats shown below:

<addr> <gross weight> <net weight> <peak value> ETX <chksum> EOT <status>

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

<addr> serial address + 80h Example: address 1 would be 1 + 80h = 81h ETX (end of text) = 03h EOT (end of transmission) = 04h

“N”

“S” “M” “O” “E”

= 1 ASCII character consisting of the following: = Stable = Motion = Overload = Error = 6 ASCII characters = 6 ASCII characters = 6 ASCII characters = 2 ASCII characters (<Addr> & ETX are not included in the checksum)

<status>

<net weight> <gross weight > <peak value> <checksum>

Character strings

NOTE: The brackets “<“ ”>“ are not sent, they are only shown for clarification.

The checksum control value is obtained by performing the XOR operation.

It is expressed with 2 Hexadecimal digits. Example: 25 = 1D

The result of the above calculation equals 1 character, which can be a numerical value of 0 to 9 or A to F (Hexadecimal)

Programming the set-points

<addr> <s2> ETX <chksum> EOT <s1> “S”

Command from the host

<s1> <s2>

= 6 ASCII characters for set-point 1 = 6 ASCII characters for set-point 2

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

The programmed values are stored in RAM, however, they are not retained if the power is removed. There is no limit on the number of times that these commands can be performed.

The transmitter responds with the following data string:

<addr> ACK EOT

<addr> “N” EOT

Page 23: Precise DAT400 (3)

23

This command is used to store the programmed set-point values in Eeprom. This command can be performed up to 100,000 times.

Store set-point values in Eeprom

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

<addr> EOT “M”

Command from the host

The transmitter responds with the following data string:

<addr> “M” EOT

Request set-point values

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

<addr> EOT “R”

Command from the host

The transmitter responds with the following data string:

<addr> <s2> ETX <chksum> EOT <s1> “R”

“Net mode” / ”Gross mode” switch command

This command performs the same function of the “FUN” key.

Switch to Gross weight mode

Command from the host

<addr> “L” “C” EOT

The transmitter responds with the following data string:

<addr> “L” “C” ACK EOT

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

Page 24: Precise DAT400 (3)

24

Modbus mode The Modbus mode is used to communicate with Modicon Programmable Controllers using a unique message structure that the controllers can understand regardless of the type of networks being used. Please refer to the tables on pages 31 through 41 for information regarding the MODBUS RTU Protocol Specifications. Modbus® and Modicon® are registered trademarks of the Schneider Automation Group.

Switch to Net weight mode

Command from the host

<addr> “N” “C” EOT

The transmitter responds with the following data string:

<addr> “N” “C” ACK EOT

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

Zero / Tare / Peak reset command

This command performs the same function of the “0” key and/or logic input (1). It’s used to zero the unit when in Gross mode, tare the unit when in Net mode, and reset the value to zero when operating in Peak Hold mode.

Command from the host

<addr> “A” “A” EOT

The transmitter responds with the following data string:

<addr> “A” “A” ACK EOT

In case of an error, the transmitter will respond with the following data string.

<addr> NAK EOT

Page 25: Precise DAT400 (3)

25

Print mode

This protocol enables the communication with a printer. The data on the printed report are the follo-wing: NET, GROSS and TARE (+ PEAK, if enabled).

The print command takes place by pressing the PRG key or by activating the remote input #2. (*) The printed report is issued only if the following conditions are met:

• Gross weight positive

• Net weight positive

• Stable weight (**)

• BLIND function disabled (***)

(*) In case the PRG key is locked (see page 6) the print command can take place through the remote input #2 only.

(**) The weight stability condition is controlled only if the “MOTION” parameter (see page 16) is set

to a value ≠ 0. If MOTION = 0 the printed report is issued even if the weight is unstable..

(***)In case the BLIND function is enabled (see page 6) the print command can take place through the remote input #2 only, not via the PRG key.

Between one printout and the next one the weight must change for at least 20 counts.

Gnd Tx Rx

19 27 24

Tx

Gnd

Rx

Connection to the printer

Printed report formats

Standard

Net

Gross

Tare

9.488

19.874

10.386

kg

kg

kg

Peak enabled

Net

Gross

Tare

9.488

19.874

10.386

kg

kg

kg

Peak 35.294 kg

Page 26: Precise DAT400 (3)

26

24 23 22 21 20 19 24 23 22 21 20 19

Gnd Tx Rx

Serial Output Wiring Connections

RS-422/485 multi-drop serial configuration allows connection of up to 32 units to a distributed control system (DCS) or programmable logic controller (PLC). See Figure 4 for the RS422 connection and Figure 5 for the RS485 connection.

RS-232 serial connections to a computer, remote serial display or other data acquisition device. See Figure 3.

Figure 3

Transmitter # 1 Transmitter # 32

— Rxd

+ Txd

+ Rxd

— Txd

Gnd

Figure 4 RS422 connection

19 27 24

Tx

Gnd

Rx

Page 27: Precise DAT400 (3)

27

Gnd Tx Rx

“INOVATION” Software: RS232 wiring to PC (COM1 / 2)

19 27 24

Tx

Gnd

Rx (Pin 2)

(Pin 3)

(Pin 5)

PC (9 pole sub-D connector) PC (25 pole sub-D connector)

Tx

Gnd

Rx (Pin 3)

(Pin 2)

(Pin 7)

24 23 22 21 20 19

Transmitter # 1 Transmitter # 32

RS485

RS485

Gnd

Figure 5 RS485 Connection

+

24 23 22 21 20 19

Not only the RS232, but also the RS422 or RS485 can be used for the communication with the Inovation software. Refer to Figures 3, 4, 5 depending on the desired connection.

Page 28: Precise DAT400 (3)

28

Sub-menu parameter selections

PARAMETERS SELECTIONS DESCRIPTION

FILTER (See notes below)

0 to 9 (Default = 5)

Digital filtering value

MOTION 0 to 4 (Default = 2)

Weight stabilization

AUTO 0 0.0 to 10.0% (of net weight value)

Auto zero range @ power up.

0 TRAC 0 to 4 (Default = 2)

Zero tracking range

VALUES

0 = no filtering 9 = maximum filtering

0 = Weight always stable 1 = slow stabilization 4 = fast stabilization

0 = function disabled

0 = function disabled

0 BAND (See notes below)

0 to 200 divisions (Default = 100)

“Zero” key operating range

0 = function disabled

Table 2 “PARAM” Menu

PARAMETERS SELECTIONS DESCRIPTION

BAUD R 2400, 9600,19200, 38400, 115200

COM1 Baud rate selection Standard baud rate: 9600

PROT-1 NONE CONTIN (ASCII) DEMAND (ASCII) AUTOM (ASCII) SLAVE (ASCII) PRINT (ASCII) MODBUS (*) BCD

COM1 Serial port transmission mode selection Standard transmission mode: Continuous (*) The possible Data Format selection for this protocol are: N 8 2 ; E 8 1 ; o 8 1 (Parity, Data bits, Stop bits)

PROT-2 PROFIB DEVNET NONE

COM2 Serial port transmission mode selection

ADDRES 01 to 32 COM1 Identification address, selectable from 1 to 32

PR ADD DN ADD

001 to 126 Profibus-DP or DeviceNet node address

DELAY 0.00 to 1.00 Delay in responding to a data request from the host in “Demand” or “MODBUS” modes (COM1). Time unit: 1/100 second (maximum 1 second)

REM-CO REMOTE Enables communication with “INOVATION” without re-positioning jumper (J1) as described on page 10.

DATA F N-8-1 N-8-2 E-8-1 O-8-1 N-7-2 E-7-1 E-7-2 O-7-1

Data Format selection for the ASCII protocols (Parity, Data bits, Stop bits). See “PROT-1”

Table 3 “SERIAL” Menu

Digital filtering affects the update rate and speed of the unit. Filter setting = 0 Update rate = 25 Hz Filter setting = 1 Update rate = 10 Hz Filter setting = 2 Update rate = 5 Hz Filter setting = 3 Update rate = 2.5 Hz Filter setting = 4 Update rate = 1.5 Hz Filter setting = 5 Update rate = 1 Hz Filter setting = 6 Update rate = 0.7 Hz Filter setting = 7 Update rate = 0.4 Hz Filter setting = 8 Update rate = 0.2 Hz Filter setting = 9 Update rate = 0.1 Hz

0 BAND: this parameter defines the operating range of the “Zero” key (and Input 1), used to zero the unit in Gross mode.

Page 29: Precise DAT400 (3)

29

Sub-menu parameter selections (cont’d)

BAUD RATE

2400 9600 19,200 38,400

0 6 Hz 25 Hz 50 Hz 50 Hz

1 6 Hz 25 Hz 50 Hz 50 Hz

2 6 Hz 25 Hz 50 Hz 50 Hz

3 6 Hz 25 Hz 25 Hz 25 Hz

4 6 Hz 25 Hz 25 Hz 25 Hz

5 6 Hz 12 Hz 12 Hz 12 Hz

6 6 Hz 12 Hz 12 Hz 12 Hz

7 6 Hz 12 Hz 12 Hz 12 Hz

8 6 Hz 6 Hz 6 Hz 6 Hz

9 6 Hz 6 Hz 6 Hz 6 Hz

D I G I T A L F I L T E R

115,200

50 Hz

50 Hz

50 Hz

25 Hz

25 Hz

12 Hz

12 Hz

12 Hz

6 Hz

6 Hz

Table 4

Continuous transmission: The transmission speed depends on the digital filter setting and the baud rate value selected. See Table 4 below for additional information.

BAUD RATE

D I G I T A L F I L T E R

2400 9600

0 12 Hz 50 Hz

1 12 Hz 50 Hz

2 12 Hz 50 Hz

3 12 Hz 25 Hz

4 12 Hz 25 Hz

5 12 Hz 12 Hz

6 12 Hz 12 Hz

7 12 Hz 12 Hz

8 6 Hz 6 Hz

9 6 Hz 6 Hz

Table 5

Driver for the optional BCD Board: The transmission speed depends on the digital filter setting and the baud rate value selected. See Table 5 below for additional information.

Page 30: Precise DAT400 (3)

30

“IN — OUT” MENU

PARAMETERS SELECTIONS DESCRIPTION

MODE 1 GROSS NET

PEAK H

Operating mode selection for output number 1.

N.O N.C

Contact status below the setpoint value

POS. NEG.

Comparison with positive or negative weight values

Output enabled only after the weight reading has stabilized.

HYST — 1 (See notes below)

(Default = 2)

Hysteresis setting, used to eliminate chattering of the relay @ coincidence point.

TIMER 1 0.0 to 10.0 (0 = disabled)

The output is disabled after the time period has expired. (1/10 second increments )

DELAY 1 0.0 to 10.0 (0 = disabled)

Time delay before the output is enabled. (1/10 second increments)

Same parameter selections as above for output 2

TEST IN See page 18 Test procedure for inputs

TEST OUT Test procedure for outputs

NORMAL STABLE

Table 6

Sub-menu parameter selections (cont’d)

NOTES: 1. The hysteresis setting must be less than it’s respective setpoint value. Entering a hysteresis setting greater than the setpoint value will automatically be replaced with a default setting of (2) counts. 2. Hysteresis settings of within 10 counts of their respective setpoint values are possible, however, much smaller values are normally sufficient. 3. A large hysteresis setting (4,990 counts) could be used as follows: Setpoint 1 is used to fill a vessel with 5,000 lbs. of product, and setpoint 2 will be used as a high weight alarm. When the weight in the vessel reaches 5,000 lbs., relay # 1 de-energizes stopping the flow, feed, etc. The product is drawn from the vessel as required, when the weight in the vessel reaches 10 lbs., setpoint # 1’s relay re-energizes and automatically refills the vessel to 5,000 lbs.

Page 31: Precise DAT400 (3)

31

Function Description

01 (01) READ COIL STATUS

03 (03) READ HOLDING REGISTERS

04 (04) READ INPUT REGISTERS

05 (05) FORCE SINGLE COIL

06 (06) PRESET SINGLE REGISTER

15 (0F) FORCE MULTIPLE COILS

16 (10) PRESET MULTIPLE REGISTERS

MODBUS RTU PROTOCOL SPECIFICATIONS

3. LIST OF FUNCTIONS SUPPORTED

The Modbus protocol writes directly into the memory of the instrument.

Use caution when sending data to the instrument: The data being sent must be within the specified ranges given in the tables on the following pages.

Some of the data is written into the E2prom’s memory (refer to the column in the tables “Stored in E2prom”) for additional information. This memory can only be written to 100,000 times, therefore, you should avoid writing continuously into this memory.

To confirm the storage of a new value in the E2prom, perform the MAKE — BACKUP function. If this function is not performed, all of the newly stored data will be lost when power is removed from the instrument.

The “Set point” setting does not require the MAKE — BACKUP function to be performed.

The set point values are expressed as number of divisions This means that any set point value (temporary or permanent) has to be multiplied by the “Display division” data, in order to obtain the actual value of the set point. E.G. Assuming that the “display division” value is 0.2; if the PLC asks for a set point value and get the data “3949” from the instrument, this means that the actual value of the set point is 789.8 (3949 x 0.2 = 789.8)

Even the other weight values are given as number of divisions, except for the “Net weight” and “Gross weight”.

“Net weight” and “Gross weight” (Modbus addresses 40006 and 40007) are given as absolute values Note: The numeric values on the following pages for (addresses, codes, and data) are represented as decimal values. The addresses given in the following tables refer to the standards provided in the Modicon Modbus Protocol Reference Guide PI-MBUS-300 Rev J.

1. PRECAUTIONS

2. DATA FORMAT

• Start Bit : 1

• Data Bits : 8, the Least Significant Bit (LSB) is sent first.

• Parity : No, Even, Odd

• Stop Bits : 1, 2

Possible Data Format Selection: N-8-2 E-8-1 O-8-1

Hexadecimal values between brackets

Page 32: Precise DAT400 (3)

32

The response time for most data requests is within 20 milliseconds. Exceptions:

• E2prom Backup command (Maximum time = 350 milliseconds)

• Writing of the following registers: Load cell/s total capacity, load cell/s sensitivity, Net weight, Tare weight, and Filter (Maximum time = 550 milliseconds).

4. INSTRUMENT RESPONSE TIME

4.1 RESPONSE TIME WHEN CONNECTING SEVERAL SLAVES

Single twisted pair

Query Master to slave 01 Response time slave 01 Response slave 01 20 mSec delay Query Master to slave 02

Double twisted pair

Query Master to slave 01 Response time slave 01 Response slave 01 delay Query Master to slave 02

With a baud rate of 19200 Time = 15 to 20 milliseconds

Each single function is explained in detail on pages 34, 35 and 36 of the operator’s manual.

Each function is composed by a Query (request master instrument) and a Response (answer instrument master). Queries and responses are composed by a sequence of data that

are briefly explained here below (***), please note that the code “0x” before any value indicates that the value is represented as hexadecimal value.

Besides, all the Modbus addresses (the ones mentioned in the left end column on pages 38 and 39) have to be represented as hexadecimal values, but, only for these addresses, there is an im-portant rule to be taken into consideration:

Before converting the address into an hexadecimal value, the 1st digit on the left has not to

be considered and the remaining 4 digits have to be decremented by “1”.

1st Example:

To represent the address 40150 (“display division” on page 38) as hexadecimal value, exclude the digit “4” (remains “0150”), then decrement by 1 the number “0150”. The result is “0149”, now perform the conversion into hexadecimal. The result is “00 95”. This is the value to be used in the query.

2nd Example:

To represent the address 40102 (“load cells sensitivity” on page 38) as hexadecimal value, exclude the digit “4” (remains “0102”), then decrement by 1 the number “0102”. The result is “0101”, now per-form the conversion into hexadecimal. The result is “00 65”. This is the value to be used in the query. (***)

Address: is the number of the instrument’s address, represented as hexadecimal value (in this case do not decrement by 1 the number).

Function: is the number of the function to be performed (see the table above) 1st Output address: is the address number where the reading of the outputs status has to start

Number of outputs: is the number of the outputs to be read 1st Input address: is the address number where the reading of the inputs has to start

Number of inputs: is the number of the inputs to be read Number of bytes: represents the number of bytes which compose a data 2 byte CRC: “Cyclical Redundancy Check”. It’s an algorithm used as checksum. Total byte: Total number of bytes transmitted. This data is not included in the strings.

Page 33: Precise DAT400 (3)

33

RTU Baud 9600

Scheme of the communication time in a Master-Slave RS-485 system, using a double twisted pair.

8 mSec 1 mSec 8 mSec

Tx PC

Tx Slave 01

Tx Slave 01

RTU Baud 19200

Tx PC

Tx Slave 01

Tx Slave 01

4 mSec 1 mSec 4 mSec

15 mSec

Page 34: Precise DAT400 (3)

34

5. LIST OF TRANSMISSION STRINGS

Symbols used in the strings

A = 1 byte for slave address (Example: Slave Nº 17: A = 0 x 11)

QUERY

RESPONSE

Address Function Number of bytes Status of outputs 2 byte Total byte

A 0 x 01 0 x 01 0 x 00 CRC 6

Status of outputs: In this byte each output is identified by 1 bit The address of the 1st. output is the least significant bit (LSB) in this byte. (1 = On, 0 = Off).

5.1. FUNCTION 1: READ COIL STATUS

5.2. FUNCTION 2: READ INPUT STATUS NOT USED

5.3. FUNCTION 3: READ HOLDING REGISTERS

QUERY

Address Function 1st. Register address Number of register 2 byte Total byte

A 0 x 03 0 x 0000 0 x 0002 CRC 8

RESPONSE

Address Function Number of bytes 1st. Register 2nd. Register 2 byte Total byte

A 0 x 03 0 x 04 0 x 0064 0 x 00C8 CRC 3 + 2 x Nº of registers + 2

Address Function 1st. Output address Number of outputs 2 byte Total byte

A 0 x 01 0 x 0000 0 x 0008 CRC 8

5.4 FUNCTION 4: READ INPUT REGISTERS (“read only”)

QUERY

RESPONSE

Address Function Number of bytes 1st. register 2 byte Total byte

A 0 x 04 0 x 02 0 x 0064 CRC 3 + 2 x Nº of registers + 2

Address Function 1st. Register address Number of register 2 byte Total byte

A 0 x 04 0 x 0000 0 x 0001 CRC 8

Page 35: Precise DAT400 (3)

35

5.5. FUNCTION 5: FORCE SINGLE COIL

QUERY

Address Function Output address Status of output 2 byte Total byte

A 0 x 05 0 x 0000 0 x FF00 CRC 8

RESPONSE

Address Function Output address Status of output 2 byte Total byte

A 0 x 05 0 x 0000 0 x FF00 CRC 8

Status of output: (FF00 = On, 0000 = Off) The response includes the echo of the query

5.6. FUNCTION 6: PRESET SINGLE REGISTER

QUERY

Address Function Register address Register value 2 byte Total byte

A 0 x 06 0 x 0000 0 x 1234 CRC 8

RESPONSE

Address Function Register address Register value 2 byte Total byte

A 0 x 06 0 x 0000 0 x 1234 CRC 8

The response includes the echo of the query

5.7 FUNCTION 7: READ EXCEPTION STATUS NOT USED

5.8 FUNCTION 8: DIAGOSTIC NOT USED

5.11 FUNCTION 11: FETCH COMM EVENT CTR NOT USED

5.12 FUNCTION 12: FETCH COMM EVENT LOG NOT USED

5.15 FUNCTION 15: FORCE MULTIPLE COILS

QUERY

Address Function 1st. Output address Nº of outputs Nº of bytes Status of outputs 2 byte Total byte

A 0 x 0F 0 x 0000 0 x 0002 0 x 01 0 x 00 CRC 10

RESPONSE

Address Function 1st. Output address Nº of outputs 2 byte Total byte

A 0 x 0F 0 x 0000 0 x 0002 CRC 8

Number of outputs: Number of the output to be written, starting from the address. Number of bytes: Number of bytes transmitted as status of outputs (8 outputs each byte) Status of outputs: 1 output each bit (1 = On, 0 = Off); the 1st. Output coincides with the least significant bit (LSB) of the 1st. Byte. Non-significant bits are set to zero. The response includes the identification of the modified outputs.

Page 36: Precise DAT400 (3)

36

5.16 FUNCTION 16: PRESET MULTIPLE REGISTERS

QUERY

Address Function 1st. Register output

Number of register

Number of bytes

1st. Register value

2nd. Register value

2 byte Total byte

A 0 x 10 0 x 0000 0 x 0002 0 x 04 0 x 0000 0 x 0000 CRC 7 + 2 x Nº of registers + 2

RESPONSE

Address Function 1st. Register address Nº of registers 2 byte Total byte

A 0 x 10 0 x 0000 0 x 0002 CRC 8

Number of registers: Number of the registers to be written, starting from the address. Number of bytes: Number of bytes transmitted as registers value (2 bytes each register) Registers value: Content of the registers, starting from the 1st. The response includes the identification of the modified registers.

6 BROADCAST MODE

The communication strings are controlled by the CRC (Cyclical Redundancy Check). If a communication error occurs, the slave unit doesn’t answer. The master unit controls a timeout when waiting for the response from the slave. If the slave doesn’t answer during this timeout, it means that a communication error has occurred.

7.1. COMMUNICATION ERRORS

This function is not implemented in the instrument

7.2. ERRORS IN THE RECEIVED DATA

If the string is received correctly but is not executable, the slave answers the master with an EXCEPTION RESPONSE. The field “function” is transmitted having the most significant digit (MSD) set to 1.

EXCEPTION RESPONSE

Address Function Exception code 2 byte

A Function + 80h 0 x 01 CRC

Description of the Exception codes.

Code Description

1 ILLEGAL FUNCTION (The function is not valid or not supported)

2 ILLEGAL DATA ADDRESS (The specified data address is not available)

3 ILLEGAL DATA VALUE (The data value received is not valid)

Page 37: Precise DAT400 (3)

37

6 BROADCAST MODE

The communication strings are controlled by the CRC (Cyclical Redundancy Check). If a communication error occurs, the slave unit doesn’t answer. The master unit controls a timeout when waiting for the response from the slave. If the slave doesn’t answer during this timeout, it means that a communication error has occurred.

7.1. COMMUNICATION ERRORS

This function is not implemented in the instrument

7.2. ERRORS IN THE RECEIVED DATA

If the string is received correctly but is not executable, the slave answers the master with an EXCEPTION RESPONSE. The field “function” is transmitted having the most significant digit (MSD) set to 1.

EXCEPTION RESPONSE

Address Function Exception code 2 byte

A Function + 80h 0 x 01 CRC

Description of the Exception codes.

Code Description

1 ILLEGAL FUNCTION (The function is not valid or not supported)

2 ILLEGAL DATA ADDRESS (The specified data address is not available)

3 ILLEGAL DATA VALUE (The data value received is not valid)

Page 38: Precise DAT400 (3)

38

Modbus Address

Description Range Value Stored in E2prom

Set Points and Weight values Relevant menu

40001 Set point 1 temporary 0 to full scale NO

40002 Set point 2 temporary 0 to full scale NO

40003 Command register 01-05, 10, 12-13, 20 (Hex)

See relative table (page 41)

40004 Set point 1 permanent SET 1 0 to full scale YES

40005 Set point 2 permanent SET 2 0 to full scale YES

40006 40007

Gross weight value (H) Gross weight value (L)

0 to full scale

40008 Input status byte See relative table (page 40)

40009 40010

Net weight value (H) Net weight value (L)

0 to full scale

Peak Value

40020 Peak gross weight 0 to full scale NO

Command data and status registers

40081 Command data register 11 (Hex) See relative table (page 41)

40082 Status register 00, 03-05 (Hex) See relative table (page 41)

40083 Status data register 06 (Hex) See relative table (page 41)

Basic Configuration

40100 40101

Load cell/s total capacity (kg) H Load cell/s total capacity (kg) L

CAPAC 0-500000 (1) YES

40102 Sensitivity of load cell/s SENSIT 1.0000 — 4.0000 (5) YES

40103 40104

Net weight of the weighing system (H) Net weight of the weighing system (L)

NET 0 to full scale (1) YES

40105 40106

Dead load of the weighing system (H) Dead load of the weighing system (L)

DEAD L 0 to full scale (1) YES

40110 Operating mode OPMODE 0-2 (3) YES

40150 Display divisions DSPDIV 0 — 14 (2) See Table “A”

YES

Weighing Parameters

40180 Digital filter value FILTER 0-9 (3) YES

40181 Motion band value MOTION 0-4 (3) YES

40182 Auto zero value AUTO 0 0.1-10.00 (3) (5) YES

40183 Zero tracking value 0 TRAC 0-4 (3) YES

Set Points Configuration

40200 Operating mode Set point 1 MODE 1 YES

40201 Hysteresis Set point 1 HYST 1 0 to full scale YES

40202 Timer Set point 1 TIMER1 0.1-100.0 (5) YES

40203 Delay Set point 1 DELAY1 0.1-100.0 (5) YES

40204 Operating mode Set point 2 MODE 2 YES

40205 Hysteresis Set point 2 HYST 2 0 to full scale YES

40206 Timer Set point 2 TIMER2 0.1-100.0 (5) YES

40207 Delay Set point 2 DELAY2 0.1-100.0 (5) YES

List of the Holding Registers (4x)

Holding Register Table continued on the following page.

Page 39: Precise DAT400 (3)

39

List of the Holding Registers (4x) cont’d

(1) The combined theoretical net and tare weight values must not exceed the total capacity value. (2) Refer to the 15 values from 0.001 to 50 (3) For the list of values please refer to the user manual. (4) They are stored in the E2prom if writing the function 0000 in the status register. (5) When setting these values the decimal point has not to be included.

Serial parameter specifications:

• Once the “serial address” and “response delay” have been modified, they take effect immediately.

• The serial port mode can’t be modified via Modbus.

• When setting a new baud rate value, the power to the instrument must be removed and re-applied in order for the

changes to take effect.

TABLE “A” IDENTIFICATION CODES

Code Display divisions

0 (00) 0.001

1 (01) 0.002

2 (02) 0.005

3 (03) 0.01

4 (04) 0.02

5 (05) 0.05

6 (06) 0.1

7 (07) 0.2

8 (08) 0.5

9 (09) 1

10 (0A) 2

11 (0B) 5

12 (0C) 10

13 (0D) 20

14 (0E) 50

Serial Configuration Relevant menu

40300 Baud rate BAUD R 0-4 (3) YES

40301 Serial address ADDRES 1-32 YES

40302 Response delay DELAY 0-100 YES

Analog Output

40400 Analog output full scale F-SCAL 0 to full scale YES

40401 Analog output operating mode MODE 0-3 (3) YES

40402 Analog output range RANGE 0-3 (3) YES

40403 Zero offset OFFSET (4)

40404 Full scale offset OFFSET (4)

40405 An-Zero (negative weight value for zero analog output)

ANZERO YES

Hexadecimal values between brackets

Page 40: Precise DAT400 (3)

40

Table of the Input Status bytes

Description Bit’s meaning

0 1

Net weight polarity + —

Gross weight polarity + —

Stable weight no yes

Millivolt polarity + —

Underload condition no yes

Overload condition no yes

Off range condition no yes

Preset tare condition no yes

Input 1 status De-activated Activated

Input 2 status De-activated Activated

Relay output 1 status De-activated Activated

Relay output 2 status De-activated Activated

Scale unloaded (*) no yes

Keyboard status Unlocked Locked

List of the Input Registers (3x)

Modbus Address

Description

30003 A/D converter internal counts H

30004 A/D converter internal counts L

30005 Millivolt value

30006 Instrument software release

30007 Instrument “On-line” (*)

List of the coils (0x)

Modbus Address

Description

Bit’s meaning Range value

0 1

00001 Logic output 1 De-activated Activated 1 bit NO

00002 Logic output 2 De-activated Activated 1 bit NO

Stored in E2prom

The Modbus address 40008 is composed by 2 bytes. The conversion of these 2 bytes from hex into binary gives the meaning of each single bit described in this table.

E.g.

if the bytes in the address 40008 are 24 85, the conversion into binary gives the sequence of bits

100100 10000101. The digit at the right hand side matches with the 1st bit (Net weight polarity), therefore the values given in the above mentioned example are equi-valent to:

Net weight polarity = 1 = negative Gross weight polarity = 0 = positive Weight stability = 1 = yes Millivolt polarity = 0 = positive Underload condition = 0 = no Overload condition = 0 = no Off range condition = 0 = no Preset tare condition = 1 = yes Input 1 status = 0 = de-activated Input 2 status = 0 = de-activated Relay output 1 status = 1 = activated Relay output 2 status = 0 = de-activated Scale unloaded = 0 = no Keyboard status = 1 = locked

1

0

1

0

0

0

0

1

0

0

1

0

0

1

(*) The scale is considered unloaded (empty) when the weight value is within the “0 Band” range (see “Table 2”, page 28)

Modbus address 30007 = 00 01: the weight value is shown on the display. The instrument is “On-line” Modbus address 30007 = 00 00: one of the error conditions (underload, overload, offrange) occurs, or any programming procedure is underway. The instrument is “Off-line”.

Page 41: Precise DAT400 (3)

41

List of the functions “Command register”

Function Codes Description Function Command Data Register

Stored in E2prom

0001 (01 Hex) Semi-automatic zero — NO

0002 (02 Hex) Auto tare — NO

0003 (03 Hex) Peak reset — NO

0004 (04 Hex) Force net weight visualization — NO

0005 (05 Hex) Force gross weight visualization — NO

0016 (10 Hex) Zero calibration — YES

0017 (11 Hex) Full scale calibration Sample weight YES

0018 (12 Hex) Reset zero calibration — YES

0019 (13 Hex) Reset full scale calibration — YES

0032 (20 Hex) Back-up E2prom — YES

List of the functions “Status register”

Function Codes Description Function Status Data Register

Stored in E2prom

0000 (00 Hex) None of the functions are activated — NO

0003 (03 Hex) Analog output zero offset adjustment — YES

0004 (04 Hex) Analog output full scale offset adjustment — YES

0005 (05 Hex) Test input / output — NO

0006 (06 Hex) Test analog output Analog output (0-64000)

NO

For additional information regarding the Modbus protocol, please refer to the Modbus Protocol Manual PI-MBUS-300 Rev J.

Page 42: Precise DAT400 (3)

42

Intrinsic Safety Barriers

FUNCTION COLOR

+ Exc. Red

+ Sense Orange

— Exc. Black

— Sense Yellow

+ Signal Green

— Signal White

Shield Bare

FUNCTION BARRIER TYPE QTY

Z961H 1

Z966H 1

Z961H 1

+/- Signal

+/- Exc.

+/- Sense

HAZARDOUS AREA

1 2 3 4 5

1 2 3 4 5 6 7

TB4

TB5

1 2 3 4 5

1 2 3 4 5

1 2 3 4 5

TB1

TB2

TB3

— Sig + Sig — Exc — Sens + Sens + Exc Shield

+ Exc — Exc + Sig — Sig Shield

+ Exc — Exc + Sig — Sig

Shield

+ Exc — Exc + Sig — Sig

Shield

+ Exc — Exc + Sig — Sig

Shield

SAFE AREA

8

5

Z961H

4

1

6

5

Z966H

4

3

8

5

Z961H

4

1

— Signal

+ Signal

— Exc.

+ Exc.

— Sense

+ Sense

— Signal

+ Signal

— Exc.

+ Exc.

— Sense

+ Sense

13 14 15 16 17 18

— Exc. + Exc. + Sens — Sens — Sig. + Sig.

Model 400 / 450 Digital / Analog Transmitter

Model CGS4 Summing Junction Box

PEPPERL & FUCHS Intrinsic Safety Barriers

Page 43: Precise DAT400 (3)

43

PrecisePrecisePrecisePrecise™ 24 Volt Power Supply

Installation

• Make sure the installation complies with local regulations and electrical codes.

• Connect AC voltage to the terminals marked “L” and “N”.

• The DC voltage is available on the terminals marked “+” and “-”. The second set of terminals are used when powering two transmitters from a single power supply (See notes).

• A red LED is illuminated when the power supply is “ON”.

Notes: The power supply should be used to power two transmitters only when a single load cell is connected to each transmitter. For multiple load cell applications it is recommended that an individual power supply be used for each transmitter. This enables the power supply to compensate for any fluctuations in the incoming line voltage. Recent field experiences have shown that voltage drops of greater than 10% can cause the transmitters to drift and become unstable.

Fuse Replacement The following procedures require work inside the power supply enclosure and should be performed by qualified service personnel.

• Before opening the unit, disconnect the AC voltage.

• Remove the front cover from the power supply.

• Press down gently on the cover of the fuse holder, and turn counter-clockwise.

• Pull out the cover and fuse as an assembly, replace fuse with a new one.

• Re-install fuse and cover as an assembly, press down gently and turn clockwise.

• Replace the front cover on the power supply.

• Re-apply AC voltage to the unit.

In the event of a malfunction, please contact the nearest distributor for assistance.

Any attempt to modify or repair the power supply will void the manufacturers warranty.

L N + —

Mains in 24 Vdc

Fuse

LED

Options

Page 44: Precise DAT400 (3)

44

EC DECLARATION OF CONFORMITY

We: Pavone Sistemi S.r.l.

Via dei Chiosi, 18 20040 CAVENAGO BRIANZA (MI)

Hereby declares that the product: DAT 400 Complies with the essential requirements of the directives 73/23/CEE, 89/336/CEE, 93/68/CEE, when used for its intended purpose The product is made in accordance with the following standards

ELECTROMAGNETIC COMPATIBILITY:

EN 61000-3-2 EN 61000-3-3 EN 61000-6-2 EN 61000-6-3 EN 61326-1

ELECTRICAL SAFETY:

EN 61010-1

The CE mark has been applied on the product Cavenago Brianza, April 15, 2004

The Manager