CZ-3D
Deep Search, 4-Tone, Target I.D. Metal Detector
OPERATING MANUAL
F I S H E R R E S E A R C H L A B O R A T O R Y
Maximized for finding older era coins
at older sites!

Краткое содержание страницы № 2

CONTENTS About Your Detector ………………………………………………………. pg. 1 Condensed Operating Instructions …………………………………. pg. 2 Factory Preset “Turn-On-And-Go” Marks ………………………… pg. 2 Setting Up ……………………………………………………………………….pg. 3 Hipmounting …………………………………………………………………..pg. 5 Control Panel ………………………………

Краткое содержание страницы № 3

ABOUT YOUR DETECTOR Your CZ-3D is an extremely advanced and sophisticated instrument. It is maximized for a very specific function — finding & properly identifying older era coins at older sites. Simply select the «enhance mode» with the utilization of the «salt/ enhance» switch to find more rare coins! The CZ-3D was designed to find more good metals such as brass, bronze, copper, silver, and certain gold: reporting it as a high tone. In addition, a fourth tone has been added to distinguish be

Краткое содержание страницы № 4

CONDENSED OPERATING INSTRUCTIONS FACTORY PRE-SET “TURN-ON-AND-GO” MARKS Your CZ-3D is fairly simple to operate, especially when compared to other target ID machines. Even so, we strongly recommend that you read this entire manual. You’ll be able to tune your CZ-3D to your specific needs and conditions. A good understanding what to do and why will lead you to more finds. If you can’t wait any longer, and you’re an experienced detector user, here’s some quick instructions to get you going: 1.

Краткое содержание страницы № 5

SETTING UP 8-inch Spider Drop-in battery compartments Adjustable search coil and cable connector at rear of non-metallic housing(not shown) lower stem Center Removable control section housing (belt loop on underside of housing) Foam hand grip Nylon wing nut (replacable Padded arm rest Duro-Neoprene Upper Lower bushings, not lock nut lock nut shown) Seven foot search coil cable Upper stem Built-in detector stand Figure 1. FISHER CZ-3D The CZ-3D comes to you just about ready to use.

Краткое содержание страницы № 6

SETTING UP 5. With the stem length properly adjusted, wrap the loop cable tightly around the center section stem and secure it with the two Velcro straps. Connect the cable connector to the control housing. CAUTION: Make sure that the cable is not pulled tight at the control housing and that you have enough slack at the search coil to adjust it to any angle. 6. With the shaft length and coil angle properly adjusted, you should be able to move into your “search” position (as shown in illus

Краткое содержание страницы № 7

HIPMOUNTING 1. Disconnect the cable from the control housing and unwind all but the last twelve inches from the stem. Secure the lower end of the cable with a Velcro strap at least twelve inches up from the coil. 2. Slide the control housing off the handle by holding the handgrip with one hand and pulling the housing towards you with the other hand. 3. Reconnect the cable to the control housing. It is especially important that the cable connector be installed tightly to prevent false sign

Краткое содержание страницы № 8

CONTROL PANEL or identify targets. 3. PINPOINT/DEPTH READING: A three purpose, spring loaded push-button. When pushed and held, the CZ-3D goes into a no-motion, all-metal mode for precise pinpointing and approximate depth reading of coin-sized targets. This button is also used in conjunction with the GROUND control during the ground balancing procedure. 4. SENSITIVITY/BATT TEST: In the extreme counter- clockwise position, the battery condition is checked as indicated by a strong or weak

Краткое содержание страницы № 9

TURN ON PROCEDURE 1. Set your controls as follows: GROUND = 10 DISC = 0 for normal use in target ID mode. (Set DISC to “Auto tune” for deep search, all-metal Auto tune mode. SENSITIVITY = 10 MODE =ENHANCE VOLUME = OFF 2. Hold the search coil waist high, away from any nearby metal. 3. Turn the VOLUME control to 10. A brief bell tone is normal when you turn the VOLUME control on. If you’re in the Auto tune Mode, you’ll hear an audio “threshold” hum. Lower the SENSITIVITY control until you ca

Краткое содержание страницы № 10

“PUSHBUTTON” GROUND BALANCE METHOD This will probably be your method of choice in all but the most difficult of ground conditions. It’s fast, easy and accurate. You can use this method in either the Autotune or Target ID mode. 1. With your controls set as in the “Turn-On” procedure, (GROUND control at 10), hold the search coil parallel to and 6 to 12 inches off the ground. Press the PINPOINT button and hold it until you’ve completed step 2. Make sure you’re at least three feet away from an

Краткое содержание страницы № 11

«BOBBING» THE SEARCH COIL METHOD 1. Set as in the “Turn-On” procedure, making sure the DISC control is at AUTOTUNE and the SENSITIVITY control is set so you can just barely hear a threshold hum. Hold the search coil parallel to and 6 to 12 inches over the ground and at least three feet away from any metal objects. Do not use the PINPOINT button during any part of this procedure. 2. Lower the coil to an inch or two above the ground and then quickly raise it. Note that as you lower the c

Краткое содержание страницы № 12

“BOBBING” THE SEARCH COIL METHOD NOTES: 1. If you get an audio response as you first lower the coil with the GROUND CONTROL at 10, you’re probably over a piece of metal. Move and try again. 2. If you get a sudden bell tone, not preceded by an increasing audio response, you’re probably in some very highly mineralized soil or sand. Instead of lowering the coil to an inch or two above the ground as in step 2 above, stop just before you hear the bell tone and ground balance as instructed. It wi

Краткое содержание страницы № 13

SEARCH MODES AUTOTUNE SEARCH MODE Set the DISC control to Autotune for a very sensitive, wide-scan, all- metal, motion search mode. Since this mode responds to all metal targets and does not have the ability to identify or reject targets, this will probably not be your normal search mode. The Autotune mode does have some advantages however which make it useful to use in at least two situations: 1. Non-Trashy Areas. Since the Autotune mode has a wider scan than the ID mode, you’re less li

Краткое содержание страницы № 14

SEARCH MODES get a response. Keep in mind that for accurate target ID, the coil center must pass directly over the target. 5. Note the response you get over small targets. For small iron or steel targets, the meter needle will usually lock in the “IRON” category. Most pull tabs, foil, nickels and the newer zinc pennies will also be correctly classified. Silver coins, copper coins, and the newer clad coins will ID in the highest category. 6. Note that an enlongated ferrous object such as a n

Краткое содержание страницы № 15

SEARCH MODES the surface may set off the bell tone. The optional, smaller 5 inch coil is more likely to overload than the standard 8 inch coil. 10. You may also note that some square tabs ID as round tabs and vice versa. Because of the wide variety of sizes, shapes and conductivity of the many pull tabs manufactured over the years, there is overlap as far as identification goes. Small pieces of tabs or aluminum are often misidentified. The tail of a round tab for example, may ID as a nicke

Краткое содержание страницы № 16

SEARCH MODES FIGURE 4. TYPICAL CZ-3D AUDIO AND METER REPONSES. zn METER IR ON 5 IR ON 1 FOIL ¢ ¢ READING ¢ $ DISC SETTING: 6 5 4 3 SHARP, NARROW RESPONSE 2 NO RESPONSE 1 0 SMOOTH, BROAD RESPONSE SEARCH A UT O COIL TUNE COPPER zn PENNY 5 FOIL 1 ¢ ¢ $ ¢ STEEL SMALL 1 ZINC BOTTLE SILVER OR SHALLOW NAIL — GOLD RINGS —- PENNY CAP CLAD COIN CAN # # # # # AUDIO RESPONSE 1 LOW TONE 2 MID 3 MID LO 2 MID 4 HI TONE BELL TONE 14 SODA

Краткое содержание страницы № 17

SEARCH MODES SUPPLEMENT A. TOM DANKOWSKI’S «ENHANCED» ID CHART • “REAL WORLD — OTHER” = Probable reading of what all other detectors will ID the specified target as in real dirt. • “REAL WORLD — CZ-3D” = Most probable reading on the CZ-3D in ‘enhance’ mode. • TARGET/REAL WORLD «REAL WORLD OTHER» “REAL WORLD CZ-3D” • Dirt exposed Indian Head Cent Trash /mid-tone High-Tone • 1857-1864 White (nickel) Cent Square-Tab/mid-tone Square-Tab • U.S. 3-Cent Silver Trash/mid-tone High-Tone • U

Краткое содержание страницы № 18

SEARCHING Good search techniques are as important to your success as having a good detector. 1. Make sure your CZ-3D is properly ground balanced and the MODE switch is in the proper position: SALT for wet ocean beaches, ENHANCE for just about every other situation. 2. Decide which search mode you’re going to use, Target ID or Autotune. Recommended starting point: Target ID mode with the DISC control set at “4”. 3. Set your SENSITIVITY control. Only experience will tell you how to set it in

Краткое содержание страницы № 19

SEARCHING Figure 5. SEARCH PATTERN. When the stem length is properly adjusted, the CZ-3D is balanced for sweeping in a tight semicircle. Wide to the right for right handers. Wide to the left for left handers.Be sure to overlap your sweeps. Figure 6. COIL ORIENTATION Keep the search coil parallel and close to the ground at all times. Figure 7. SEARCH COIL DETECTION PATTERN 1. Minimum Depth a. Very slow or fast sweep speed. b. Discrimination set at “6.” 2. Good Depth a. Moderate sweep

Краткое содержание страницы № 20

PINPOINTING PUSHBUTTON PINPOINT MODE Target location is quick and easy using the push-button Pinpoint mode. You do not have to keep the coil moving to get a response in this mode. 1. Once the presence of a target is indicated by the “beep-beep” of your CZ-3D, simply move the coil away from the target area, and with the coil lightly on the ground or very close to it, press and hold the PINPOINT button. It doesn’t matter which mode you’re searching in, Autotune or Target ID. 2. As you bring

(скачивание инструкции бесплатно)

Формат файла: PDF

Доступность: Бесплатно как и все руководства на сайте. Без регистрации и SMS.

Дополнительно: Чтение инструкции онлайн

background image

Переносной 

арочный 

металлодетектор

Руководство 

пользователя

1

Страница:
(1 из 22)

навигация

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

Оглавление инструкции

  • Страница 1 из 23
    Переносной арочный металлодетектор Руководство пользователя 1
  • Страница 2 из 23
    Описание: Габариты Вес Темп. Влажн. Питание Управление Индикация Тревога Сервис Гарантия 2 В рабочем положении — 2,20м х 1,20м х 0,90м Рабочий проем — 2,00м х 0,80м В транспортном виде — 0,66м х 0,58м х 0,90м 45кг. — 20ОС + 60ОС. 95% без конденсата. Встроенные аккумуляторные батареи, время работы
  • Страница 3 из 23
    Инструкция по монтажу: 1. Удалите транспортные ремни и разложите все компоненты. Установите два основания на выбранной поверхности. Чтобы убедиться, что основания расположены правильно и параллельно друг к другу, установите на них блок управления. Не включая блок управления, снимите его с
  • Страница 4 из 23
    4. Положение передающих и приемных панелей определяется ориентацией блока управления. Если смотреть со стороны выхода (позиция оператора), то справа – три передающие панели, слева – три приемные панели. Отличия между приемными и передающими панелями: Приемные панели имеют 32-х контактные разъемы и
  • Страница 5 из 23
    5
  • Страница 6 из 23
    6. После сборки боковых панелей установите на них блок управления, соблюдая правильность направления вход-выход. Закрепите блок управления защелками. Для удобства монтажа контрольной панели рекомендуется использовать стремянку. В отсутствие стремянки можно собрать конструкцию, как на рисунке внизу,
  • Страница 7 из 23
    Инструкция по демонтажу: 1. Выключите блок управления. Установите вспомогательные опоры, отомкните защелки и снимите блок управления. 2. Разберите боковые панели и отложите их в сторону. Задвиньте вспомогательные опоры в основания. 3. Расправьте транспортные ремни, положите блок управления на
  • Страница 8 из 23
    5. Сложите панели стопкой поверх оснований, таким образом, чтобы стыковочные конусы расположились со стороны колес блока управления. Все элементы металлодетектора имеют стыковочные шипы и пазы, при укладке следите за их совпадением. Защелки должны быть закрыты! 6. Натяните и закрепите транспортные
  • Страница 9 из 23
    Клавиатура: Управление M-Scope осуществляется через клавиатуру на блоке управления. Кнопки ▲ и ▼ – одно функциональные, кнопки 0-9 несут двойную функцию, см. таблицу. Кнопка Обозначение Функция 0 ON/OFF Вкл./Выкл., выход из меню 1 VOL 2 SENS Чувствительность 3 CON Контрастность 4 CNT Счетчик 5 RATE
  • Страница 10 из 23
    Работа с детектором: Включите устройство нажатием клавиши ON/OFF на клавиатуре. Металлодетектор включится и проведет цикл самодиагностики. На экране отобразится логотип и напряжение на аккумуляторах. Во время самодигностики светодиодный индикатор уровня сигнала будет менять значение от минимального
  • Страница 11 из 23
    Оптические детекторы: Внутри проема детектора расположены шесть инфракрасных (ИК) лучевых детекторов, три — со стороны входа и три — со стороны выхода. Сигнал тревоги формируется только в том случае, если произошло пересечение одного и более лучей. Индикатор уровня сигнала может отображать
  • Страница 12 из 23
    Обнаружение металлических предметов: Когда человек проходит сквозь детектор, индикаторы зон остаются зелеными, индикатор статуса горит желтым, а индикатор готовности красным. Индикатор уровня отображает уровень детектируемого сигнала. Если уровень сигнала не превысил пороговое значение ни для одной
  • Страница 13 из 23
    Залипшая кнопка: Если какая либо кнопка нажата более двух секунд, индикатор уровня сигнала гаснет, индикатор готовности и светодиоды зон загораются красным, а на дисплее отображается надпись «KEY IS STUCK!». Также на дисплее отображается вид клавиатуры, где залипшая кнопка выделена темным
  • Страница 14 из 23
    Настройка параметров: Для выхода из любого меню настройки нажмите 0, либо подождите 10 секунд, и тогда M-Scope автоматически вернется в рабочее состояние. Нажатие кнопок ▼/▲ более 1 секунды ускоряет изменение параметра. Громкость Для настройки громкости нажмите 1. M-Scope издаст звуковой сигнал.
  • Страница 15 из 23
    Контрастность Для настройки контрастности ЖК дисплея нажмите 3. Используя кнопки ▼/▲ установите необходимый уровень. Это значение сохраняется в памяти автоматически. Счетчики / Статистика Чтобы просмотреть статистику нажмите 4. На дисплее выводятся четыре значения: PeoPle — общее количество
  • Страница 16 из 23
    Управление паролями: Доступ к настройкам детектора можно ограничить паролем, который задается в меню Access. Нажмите ▼. Если включена защита паролем, на ЖК дисплее появится предложение ввести код. По умолчанию код доступа 01, если пользователь не задал иное значение. На ввод неправильного кода на
  • Страница 17 из 23
    Экран сброса кода User 2. Введите новый код. Длина кода от одного до десяти знаков. Если в течение 4 секунд не нажата ни одна кнопка, дисплей перейдет в меню «Access Codes». Ввиду того, что нет кнопки Enter и длина кода не фиксирована необходимо после ввода кода выждать паузу 4 секунды. Через 4
  • Страница 18 из 23
    Программы: Ввиду того, что M-Scope является мобильным детектором, то для разных объектов необходимо использовать разные настройки. Для этого предусмотрена возможность сохранить в памяти устройства три заранее заданных программы. Вызов любой из программ осуществляется коротким (< 1секунды) нажатием
  • Страница 19 из 23
    Диагностика: В M-Scope предусмотрен режим диагностики. Для входа в этот режим: выключите детектор, затем включите и быстро нажмите ▼, затем ▲. Интервал между нажатиями – не более 2 секунд. Дождитесь завершения цикла опроса индикаторов. Это заставка режима диагностики. Здесь отображена информация о
  • Страница 20 из 23
    Тест светодиодов: Исправность светодиодов можно проверить из диагностического меню, нажимая соответствующие кнопки на клавиатуре. Время свечения 4,5сек. Кнопка Индикатор уровня Индикаторы зон Индикатор состояния Индикатор готовности 1 1 – зел. Все – зел. Выкл. Выкл. 2 2 – зел. Выкл. Выкл. 3 3 –
  • Страница 21 из 23
    Устранение неисправностей: Перед демонтажом M-Scope обязательно выключите Блок управления! 1. После включения детектор сразу же выключается. Проверьте напряжение на аккумуляторах, и если оно ниже 10,9 вольт, произведите зарядку, либо подключите детектор устройству. 2. Детектор исправен, но не
  • Страница 22 из 23
    Во избежание повреждений при транспортировке M-Scope защелки на панелях должны быть закрыты! НЕПРАВИЛЬНО ПРАВИЛЬНО При работе с M-Scope обращайте внимание: ● ● ● ● ● Контактные группы на панелях, основаниях, блоке управления всегда должны быть чистыми и сухими. Протирка поверхностей проводится
  • Страница 23 из 23

Инструкции и руководства похожие на GARRETT FISHER M-SCOPE

Другие инструкции и руководства из категории Арочный металлодетектор

© 2023 manuals-help.ru, Все права защищены

Переносной

арочный

металлодетектор

Руководство

пользователя

1

Описание:

Габариты

В рабочем положении

— 2,20м х 1,20м х 0,90м

Рабочий проем

— 2,00м х 0,80м

В транспортном виде

— 0,66м х 0,58м х 0,90м

Вес

45кг.

Темп.

— 20ОС + 60ОС.

Влажн.

95% без конденсата.

Питание

Встроенные аккумуляторные батареи, время работы до 40ч.

Сетевой источник 220В/50Гц — зарядное устройство.

Управление

Цифровая клавиатура с ЖК дисплеем.

Индикация

Светодиоды.

Тревога

Светодиоды 3 зоны, настраиваемый звук.

Сервис

Самодиагностика, автокалибровка.

Гарантия

24 месяца

2

Инструкция по монтажу:

1. Удалите транспортные ремни и разложите все компоненты. Установите два основания на выбранной поверхности. Чтобы убедиться, что основания расположены правильно и параллельно друг к другу, установите на них блок управления. Не включая блок управления, снимите его с оснований.

2. Установите вспомогательные опоры, расположенные на базовых блоках. Для этого потяните опору из основания до тех пор, пока она не начнет вращаться, затем поверните ее так, чтобы опора коснулась поверхности земли, и потяните еще до фиксации. Повторите это со всеми опорами.

3. Выберите, какая сторона портала будет входом, а какая – выходом. Вход/выход определяется ориентацией блока управления. Позиция оператора располагается со стороны выхода, на блоке управления с этой стороны находится светодиодная шкала.

Внимание: неправильное расположение блока управления и панелей вызывает неисправность в работе устройства!

3

4. Положение передающих и приемных панелей определяется ориентацией блока управления. Если смотреть со стороны выхода (позиция оператора), то справа – три передающие панели, слева – три приемные панели.

Отличия между приемными и передающими панелями:

Приемные панели имеют 32-х контактные разъемы и маркируются зелеными метками со стороны выхода; Передающие панели имеют 16-ти

контактные разъемы и маркируются красными метками со стороны выхода.

Цветные метки расположены под защелками.

5. Осторожно, не меняя положение оснований, установите на них панели и зафиксируйте соединение защелками. Проверьте что цветные метки расположены со стороны выхода, зеленая метка соответствует приемной, а красная – передающей панели. При стыковке панелей обращайте внимание на то, что конусы с ключами должны входить в соответствующие чашки с пазами. Зафиксируйте панели между собой при помощи защелок.

4

Garrett FISHER M-SCOPE User Manual

5

6. После сборки боковых панелей установите на них блок управления, соблюдая правильность направления вход-выход. Закрепите блок управления защелками.

Для удобства монтажа контрольной панели рекомендуется использовать стремянку.

В отсутствие стремянки можно собрать конструкцию, как на рисунке внизу, а затем аккуратно установить ее поверх собранных панелей.

7.Задвиньте вспомогательные опоры обратно в основания.

Вкаждом основании находятся аккумуляторные

батареи. Вы можете подключить зарядное устройство к любому из двух оснований.

При собранном металлодетекторе происходит одновременная зарядка обоих аккумуляторов. В противном случае каждую батарею необходимо зарядить отдельно.

6

Инструкция по демонтажу:

1. Выключите блок управления. Установите вспомогательные опоры, отомкните защелки и снимите блок управления.

2.Разберите боковые панели и отложите их в сторону. Задвиньте вспомогательные опоры в основания.

3.Расправьте транспортные ремни, положите блок управления на ремни, колесами вниз.

4. Переверните основания и разместите их в соответствующих пазах блока управления.

7

Loading…

FRL#8730021-G

SECURITY SOLUTIONS

Fisher Research Laboratory

1465-H Henry Brennan,

El Paso, Texas 79936

Tel 915.225.0333 Fax 915.225.0336

www.fisherlab.com email: [email protected]fisherlab.com

S E C U R I T Y S O L U T I O N S

2

OPERATION MANUAL

Fisher Labs M-Scope

Portable Walk-Through Metal Detector

U.S. and E.U. Patents Pending

Copyright© 2008 First Texas Products L.P. All Rights Reserved.

TABLE OF CONTENTS

Features …………………….. pg. 2

Introduction ……………….. pg. 3

M-Scope Expanded View ….. pg. 3

Assembly ……………………. pg. 4

Disassembly ………………… pg. 9

Getting Started ……………. pg. 11

Basic Start Up Operation ….. pg. 12

Detection and Alarms ……… pg. 13

Advanced Functions ………… pg. 15

Diagnostic Screens …………. pg. 20

LED Testing ………………….. pg. 21

Tips …………………………… pg. 22

Specifications ……………….. pg. 23

Some objects may not be detected because of their composition, size, and location on the subject. If an undetected object passes through the M-Scope, that object may be used as a weapon in a secure area to cause injury or death.

The M-Scope should only be used by persons trained and who have a thorough understanding of its operation. If the user of a M-Scope does not follow the operating manual and if the M-Scope is not set up properly, it can allow metal objects to pass through undetected.

Metal detectors have been associated with EMI (electromagnetic interference) that may potentially effect pacemakers and

ICDs. We recommend that any patient with such a device be screened by alternative methods.

FEATURES

:

• Modular construction for rapid deployment

• 40 Hours of battery life on a single charge

• Intuitive three-zone detection and alarm status indicators, on both entry and exit sides

• Audio alert with adjustable volume control

• Intuitive, user-friendly control panel

• Self-diagnostic

• Adaptable to virtually all environments and conditions

• 100 sensitivity settings with password protection

• Adjustable rate alarm, transit and target counters records key statistical data

• Ease-of-use facilitates “split cognition” freeing operator to monitor surroundings

SPECIFICATIONS

DIMENSIONS

• 88” x 43.5” x 23.75”

PORTABLE DIMENSIONS

• 37” x 23” x 26”

WEIGHT

• 90 lbs.

SPECIFICATIONS

• Temp -20 C to +60 C (-4 F to +140 F)

• Relative Humidity 95% non condensing

BATTERY/AC POWER

• 2 rechargeable batteries — 40 hours of battery life on a single charge

• AC power options include 110V/60Hz or 220V/50Hz

WARRANTY

• 24 months parts and labor

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the

FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equip ment does cause harmfill interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:

— Reorient or relocate the receiving antenna.

— Increase the separation between the equipment and the receiver.

— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

— Consult the dealer or an experienced radio/TV technician for help

23

TIPS

1. The M-Scope should be powered down (turned off) prior to disassembling the unit, or prior to disconnecting or swapping any of the transmitter and receiver panels.

2. Unit comes on and then cycles off.

a. Check the battery voltage and if below 10.9 volts, recharge the batteries completely or hook up the charging unit.

The voltage must be above the 10.9 range or the unit will not come on. See Fig. L

3. Unit tries to come on but won’t power up.

a. Check the position of all the transmit and receive panels and make sure they are placed properly, and that the top is put on correctly. There are red and green dots under the latches that are used to help with the correct placement of the panels. See Fig. G

4. Unit comes on but has no display on screen (blue screen).

a. Press the number 3 key on the control panel and then use the up arrow until the screen contrast returns the desired level, or b. Press the factory preset key #6 or any of the user preset keys #7, 8, or 9.

5. Unit comes on but has a blocked photo diode.

a. Disassemble the unit and reassemble it placing the receive panels in a different order. Make sure to check for proper placement of the bases. If the unit still shows a blocked diode but in another location the panel will need to be

replaced.

b. Make sure that the unit is placed on level ground so that the panels are parallel with each other. We recommend that bases with the leveler option be used on uneven surfaces.

6. Unit is plugged into the charger but the voltage isn’t going up.

a. Make sure the AC plug is plugged in to a live outlet, and that the charger output plug is pushed all the way in to the unit and making good contact. See Fig. L

7. To switch unit to operate at 50/60 Hz mode. a. In diagnostic mode, press the up button which will allow you to toggle between 50/60 Hz. When operating in countries with 60 Hz AC power, the 60 Hz mode should be selected. Conversely, when operating in countries with 50 Hz AC power, the 50 Hz mode should be selected. 50 Hz will not operate correctly within a 60 Hz environment and vice versa.

8. Fisher recommends that all M-Scope units intended for outdoor useage be used with our Weather Protective Package option. This option includes a pop-up shelter that shields the M-Scope from direct sunlight (UV rays), and from rainfall.

The “Weather Protected” option also includes a mat to keep the bases from getting excessively dirty.

9. Fisher recommends that when using a hand held weapons detector in conjunction with the M-Scope, the hand held operator stand approximately 3 feet or more from the M-Scope.

10. Remember that the M-Scopes factory default access code is 01. The default access code will remain 01 until it is changed by a user.

11. Remember that when storing or transporting your M-Scope, make sure that you secure the latches in their locked position to prevent them from bending or breaking.

INCORRECT > latches unlocked

< CORRECT latches in the locked position

22

12. Remember the following tips for caring and maintaining your M-Scope:

• Check the spring contact pins and boards for dirt and debris.

• When cleaning your M-Scope, use a damp cloth only.

• Do not submerge the bases or allow the bases to be placed in an area where their is a chance they might get rain runoff.

• Do not use the M-Scope in direct rain, see Tip 8 for information on Fisher’s Weather Protective Package Option.

• If your M-Scope, does get wet, turn off immediately and disassemble. Wipe external surfaces dry and slightly shake

individual parts to remove water from inside the unit. Allow the unit to thoroughly dry before you assemble and turn on.

If you are experiencing trouble, after you have allowed the unit sufficient time to dry, please contact the factory

13. Please see details on your warranty card if service becomes necessary or contact the Fisher factory.

INTRODUCTION

Fisher Labs is excited to introduce the M-Scope™ Portable Walk-

Through Metal Detector! The

M-Scope™, the world’s most versatile walk-through metal detector, brings Fisher’s expertise, innovation, and reputation for quality metal detection solutions to the critical and demanding security market.

A

SS

E

BLE

D CONFIGU

RA

TI

O

N

TTTO

TTTT TE

CON

FIGURA

TIO

N

CONTROL PANEL

BASES

3

4

M-SCOPE

PORTABLE WALK-THROUGH METAL DETECTOR

ASSEMBLY INSTRUCTIONS

STEP

1

Begin by selecting the most even and level surface on which to assemble your M-Scope unit. Remove the transport straps and un-stack all the components. FIG. A Place the two INTERCHANGEABLE base units on the selected ground surface. FIG. B

FIG. A FIG. B

STEP

2

Place control unit on top of the two bases. FIG. C — This step ensures that the bases are properly spaced, and parallel to

FIG. C

STEP

3

If your M-Scope is equipped with the leveling option proceed with step 3, if not, move to step 4. We recommend that bases with the

leveler option be used on uneven surfaces. Hold the base assembly level, and engage the push-button levelers by depressing each of the four lever actuators’ pushbuttons in turn. FIG.D — Depressing one of these pushbuttons releases its leveler leg so it can drop down as far as necessary to reach the floor below. Releasing the pushbutton locks the leg in place. Releasing the leveler legs while the control unit and bases are level to the ground allows the legs to automatically extend to the proper length necesssary to hold the M-Scope security gate assembly level. The leveler legs can make up for low spots in the

ground’s surface up to two inches deep.

LED Testing

The LEDs can be controlled manually while in the diagnostics mode by pressing the different numeral keys. Duration is approximately

4.5 seconds, then returning to diagnostic mode. The ready light will go green and the LED bar graph displays the signal strength.

Numeral 1 key

Numeral 2 key

Numeral 3 key

Numeral 4 key

Numeral 5 key

Numeral 6 key

Numeral 7 key

Numeral 8 key

Numeral 9 key

Down arrow key

Up arrow key

Numeral 0 key

Bar graph LED 1 on

GREEN

Bar graph LED 2 on

GREEN

Bar graph LED 3 on

GREEN

Bar graph LED 4 on

GREEN

Bar graph LED 5 on

YELLOW

Bar graph LED 6 on

YELLOW

Bar graph LED 7 on

RED

Bar graph LEDs all

OFF

Bar graph LEDs all

OFF

Bar graph LEDs all

ON

Bar graph LEDs all

OFF

Under system control

All Zone [“RX” ]

Lights glow

GREEN

Top Zone Light

GREEN

Middle Zone Light

GREEN

Bottom Zone Light

YELLOW

Top Zone Light

GREEN

Middle Zone Light

GREEN

Bottom Zone Light

RED

Top Zone Light

GREEN

Middle Zone Light

GREEN

Bottom Zone Light

GREEN

Top Zone Light

GREEN

Middle Zone Light

YELLOW

Bottom Zone Light

GREEN

Top Zone Light

GREEN

Middle Zone Light

RED

Bottom Zone Light

GREEN

Top Zone Light

GREEN

Middle Zone Light

GREEN

Bottom Zone Light

GREEN

Top Zone Light

YELLOW

Middle Zone Light

GREEN

Bottom Zone Light

GREEN

Top Zone Light

RED

Middle Zone Light

GREEN

Bottom Zone Light

GREEN

Top Zone Light

RED

Middle Zone Light

RED

Bottom Zone Light

RED

Zone Lights all

GREEN

Under system control

Status Light OFF

Status Light OFF

Status Light OFF

Status Light OFF

Status Light OFF

Status Light OFF

Status Light OFF

Status Light

GREEN

Status Light

YELLOW

Status Light

RED

Status Light OFF

Under system control

Ready [go/stop] Light

OFF

Ready Light OFF

Ready Light OFF

Ready Light OFF

Ready Light OFF

Ready Light OFF

Ready Light OFF

Ready Light GREEN

Ready Light

YELLOW

Ready Light

RED

Ready Light OFF

Toggles 50/60Hz selection

Under system control

RETURNS

TO NORMAL

OPERATING MODE

21

20

Please contact the Fisher factory or your Fisher Sales Representative, or Distributor if you have not had technical training on accessing the diagnostic screens!

Diagnostics Screens

The M-Scope has a Diagnostic Mode that can be used to check the performance of its six Photo Detector channels, and of its three separate metal detector zones. It is also useful for exercising all of the system’s various LEDs.

This mode was not designed for M-Scope operators’ use. Misusing it can’t damage anything, so its operation is described below.

To enter the diagnostic mode, begin with the power to the M-Scope turned off. Turn the power on, and quickly press the down arrow key, then the up arrow key, then wait for the unit to complete its LED sequencing self test pattern. Each of these arrow key presses must be done within two seconds of powering on.

This is a diagnostics mode entry on screen. It displays the software date and version information. If you ever need to contact the manufacturer of your M-Scope to ask questions about, or report trouble with your unit, it will be very helpful if you include this information in your correspondence.

Press any key to exit the diagnostics mode entry screen.

Press the 0 key twice to return to normal operating mode.

The operational diagnostic mode screens show the six Photo Detector channels’ states.

The open, light colored ovals represent channels that are receiving a full power light signal. The filled in, dark colored ovals represent channels that are blocked , indicating that they are being occluded by an obstruction in the passageway. Channels receiving only partial illumination are depicted by partially filled in ovals.

Ideas by Fisher

0 0 0 0 7 2 1 1 F 4

0 7 / 1 9 / 2 0 0 8

6 7 7 2

The alphanumeric characters between the pairs of ovals represent the magnitudes of the three zones’ most recent target measurements. These values are expressed in hexadecimal engineering units *, and they vary with the system’s sensitivity setting.

Diagnostic mode target measurements are made by passing a target through the portal, across the Photo Detectors’ paths, just as they are in normal mode.

The time it takes the target to go through the Photo Detectors’ paths is shown in units of seconds. This value is displayed as t=xxS .

*{Hexadecimal, also known as base sixteen, is a numbering system based on sixteen single digit characters. The character set contains the ten decimal characters 0 through nine, followed by the first six letters of the alphabet, A through F. The smallest two digit value in ‘hex’ is 00 and the largest is FF}.

Dia

0 0

0 0

0 0

Dia

G

G nostic s t =1.3 S

50Hz

Battery

12.2

0 = Exit nostic s t =1.3 S

50Hz

Battery

12.2

0 = Exit

Dia

G nostic

0 E

2 7

0 4

1 D s t =1.3 S

50Hz

Battery

12.2

0 = Exit

Dia

G nostic

3 0

0 0 s t =1.3 S

50Hz

Battery

12.2

0 = Exit

STEP

4

The walls can be tipped over when they are not connected to each other through the control unit, so before assembling the walls, we need to make sure that the bases will be stable enough to build on. (Once the unit is fully assembled, the walls and control unit will form a stable structure that can’t be pushed over easily). There are adjustable outrigger supports built into the sides of the bases that are used to increase the width of the bases’ stances while the walls are being raised. This makes the walls less prone to being knocked over. To adjust one of these outriggers, pull it out part way, until it is free to rotate. There are several positions at which the outrigger will lock into place when fully extended. Rotate the outrigger to the point where the outrigger’s foot is in contact with the ground, then pull the outrigger all the way out, and try turning it slightly in either direction until it locks in place in the best position available. Follow this the process with the M-Scopes four outriggers. FIG. E

FIG. E

STEP

5

At this point you must decide which end of the portal will serve as the entrance and which will serve as the exit. The operator’s position is the exit, which is the end facing the LED bar graph and L.C.D. FIG. F — Note that the transmitter &

receiver panels position is determined by the orientation of the control panel. When facing the exit/operator position, the right hand wall will consist of three transmitter panels, and the left hand wall will consist of three receiver panels. Incorrect

placement of the control unit & panels will cause the unit to malfunction!

FIG. F

EXIT

operator position

1 LED

LED BAR GRAPH

traffic flo w

FACING THE EXIT / THE OPERATOR POSITION

5

6

STEP

6

There are two types of panels in the M-Scope system. They are called ‘Transmitter’ and ‘Receiver’ panels. Here are several ways in which you can easily tell them apart. FIG. G a. Receiver panels have 32 spring loaded contact pins

Transmitter panels have 16 spring loaded contact pins b. Receiver panels have one LED in the middle of each of the two outer vertical edges Transmitter panels have plain black plastic plugs in the places where the receiver panels have LEDs.

c. Receiver panels have green “dots” on the exit side, underneath the latches. and Transmitter panels have red

“dots” on the exit side, underneath the latches.

FIG. G

GREEN/RECEIVER OR RED/TRANSMITTER“DOT”

(underneath latches on exit end of panels)

32

RECEIVER PANEL

RECEIVER PANEL/ZONE LED’s

TRANSMITTER PANEL

16

TRANSMITTER PANEL/PLASTIC PLUGS

PRESETS

The M-Scope’s ideal group of settings may change with different users’ individual preferences, or in different security applications.

The M-Scope can store three separate groups of settings under the headings of User Presets 1, 2 and 3. These correspond to numeral keys 7,8 and 9 respectively. A fourth group of settings, called the Factory Presets, corresponds to the numeral 6 key. To configure the M-Scope to use any of these four Preset groups, simply press the corresponding numeral key when the M-Scope is in normal operating mode. For example, pressing the numeral 8 key will set the M-Scope to the configuration stored in User Preset 2.

When you receive your M-Scope, Presets 1, 2, 3 and the FP (factory Preset) will be saved to the following levels. Before using the M-Scope in any application, all target types and sizes of interest should be passed through the M-Scope to properly select the appropriate sensitivity settings. Read below if you would like to configure your own unique Presets.

FPSET (factory Preset)/ numeral 6:

(high sensitivity level)

MAIN SENS …………………. = 50

TOP ZONE ……………………. = 1.00

MID ZONE …………………… = 1.00

BOTTOM ZONE ………………. = 1.00

Factory Preset

1 = Volume

( 03 )

2 = Sensitivity ( 50)

3 = Contrast ( 51)

5 = Rate Alarm ( 04)

0 = Exit

PRO1 (memory #1)/ numeral 7:

MAIN SENS …………………. = 80

TOP ZONE ……………………. = 1.30

MID ZONE …………………… = 1.00

BOTTOM ZONE ………………. = 1.80

Recalled Program

1 = Volume

( 03 )

2 = Sensitivity ( 80)

3 = Contrast

( 51)

5 = Rate Alarm ( 03 )

0 = Exit

PRO2 (memory #2)/ numeral 8:

(medium sensitivity level)

MAIN SENS …………………. = 45

TOP ZONE …………………… = 1.30

MID ZONE …………………… = 1.00

BOTTOM ZONE ………………. = 1.50

Recalled Program

1 = Volume

( 03 )

2 = Sensitivity ( 45 )

3 = Contrast

( 51)

5 = Rate Alarm ( 03 )

0 = Exit

PRO3 (memory #3)/ numeral 9:

(low sensitivity level)

MAIN SENS …………………. = 20

TOP ZONE ……………………. = 1.00

MID ZONE ………………….. = 0.80

BOTTOM ZONE ………………. = 1.20

Recalled Program

1 = Volume ( 03 )

2 = Sensitivity ( 20)

3 = Contrast

( 51)

5 = Rate Alarm ( 03 )

0 = Exit

To assign a group of settings to one of the User Presets, adjust the all of the M-Scope’s variables as discussed in the preceding instructions, and then press and hold the corresponding numeral key for at least one second to store the settings. This is similar to the way most car radio Presets are stored. Note: the Factory Presets cannot be changed.

If the M-Scope is password protected (Access enabled mode), the system will prompt the operator to enter in their password, or Access code.

Changing the values in any of the three User Presets while the unit is in the Access enabled mode, requires a Master level access code.

19

Access Menus / Password Protection (Continued)

Editing the access menu is the way to change access codes, and enable or disable the access protection feature.

To change an access code, open the Edit access menu, and then press the numeral key corresponding to the code location you wish to change. For example, press numeral 1 to change the Master 1 access code. Similarly, press the numeral 2 key to change the User

2 access code, etc. This will open the Reset access code screen.

Code Lock

1 = Master 1

2 = User 2

3 = User 3

4 = User 4

5 = Code Lock Off 0 = Exit

Here is the User 2-reset access code screen.

Enter the new code. The code can be of any length from one through ten digits long.

If no key is pressed within four seconds, the system will revert back to the Edit

Access screen. Because there is no Enter key, and the code password length is not fixed, you must wait for the four-second timeout after you finish entering your new code.

Code Lock

Disabled

5 = Code Lock On 0 = Exit

Reset Code2

Enter New Code

*

Four seconds after entering the new User 2 code, the system will switch to the Reenter access code menu, and prompt you to verify the new code by re-entering it.

Reset Code2

Enter New Code

*

Re-Enter Code

*

If the two entries do not match, the system will display Code Mismatch and return to the Reset access code menu after a four second pause.

Code Mismatch!

18

After the new user code has been successfully entered and verified, the system will open the Code saved menu. This feature allows the status of the newly stored access code’s user to be assigned either User or Master status. Each time the numeral 1 key is pressed, the code saved menu screen will alternate between displaying User and

Master. User # 1 always has Master’s status. Press the Numeral 0 key to return to the

Edit access menu. Press numeral 0 [or wait ten seconds] to exit the Access menus.

Default Codes:

MASTER 1 = “01”

USER 2

USER 3

USER 4

= “1”

= “2”

= “3”

Code 2 Saved as User

1 = To

GG le 0 = Exit

STEP

7

Being careful not to disturb the bases’ positions, connect the bases to the panels and fasten the base draw latches. The base latches may need to be adjusted from time to time. Note that on the exit side of the panels: the green “dots” will Line up on the

Receiver panels and the red “dots” will Line up on the Transmitter panels. Stack the panels together by inserting a cone into the appropriate cup & fastening the panel draw latches as it is installed. Note that each panel has one “keyed” cone corresponding

to one specific cup on another panel. FIG. H

FIG. H base draw latches panel draw latches cup cone

GREEN/RECEIVER OR RED/TRANSMITTER“DOT”

cone keyed cone

7

8

STEP

8

STEP

9

Once the walls are assembled, place the control unit on top of them, paying attention to the proper exit/entrance orientation.

The control unit’s cups are keyed just like the panels’ cups are. Fasten all four of the control unit’s draw latches.

FIG. I

FIG. I

If you are not tall enough to assemble the unit as described in steps

7 and 8, you can use a small ladder or stepstool, or you may assemble the walls with just two of the panels. Fasten the top panels to the control unit forming a structure that looks like a table FIG. J — Carefully lift this assembly onto the existing walls, and fasten the remaining latches. Avoid putting stress on the joints between the panels and the control unit by keeping the panels parallel and straight.

FIG. J

STEP

10

Push the outriggers back into the bases. FIG. KTHE UNIT’S ASSEMBLY IS COMPLETE. You may elect to plug the charger into the charger connector on either of the two bases. FIG. L — As long as the unit is powered on, one charger will charge both batteries (there is a total of two batteries, one in each base). When unit’s power is off, (as when unit is disassembled), each base will have to be connected to the charger individually, to charge both batteries. This can be done by using a standard ‘Y’ cable assembly. Such cable assemblies are available from Fisher or your local distributor.

FIG. K FIG. L

5. RATE ALARM MENU

To access the rate alarm menu, press the rate key [numeral 5] while the M-Scope is in normal operating mode. The LCD will show the rate alarm setting. There are six possible speed settings including the disable rate alarm setting [i.e. 0.2m/S,

0.5m/S, 1.0m/S, 1.5m/S, 2.0m/S, Disabled]. All rates are expressed in meters per second. Use the Up/Down arrows to adjust the rate alarm setting. Press numeral

0 [or wait ten seconds] to exit the rate alarm menu. If the rate alarm is not set to

DISABLED, a subject taking too long (more than 7.5 seconds) to exit the M-Scope will also cause a speed violation.

While in the Rate Alarm Menu, a user can choose to set the M-Scope to an “Entrance

Only Active” mode. In this mode, the M-Scope alarms and counts people that enter the unit through the entrance only, and ignores those entering through the exit side of the unit. The “Entrance Only Active” mode can be set by pressing the numeral 5 key while in the Rate Alarm Menu. “Entrance Only Active” will be displayed in the rate alarm menu and on the title screen when powering the unit on. This function is useful in situations where there is an interest in screening people entering an event and but not screening or acquiring statistics (for example, people or target counters) when they are leaving.

To return to the normal operating mode (the alarm and counter are active when people enter through the entrance and exit), press the 5 key again, while in the Rate Alarm Menu.

6. ACCESS MENUS / PASSWORD PROTECTION

Access to adjustable parameters such as sensitivity and rate alarm settings, and to the statistics counters, may be password protected using the features found on the Access menu. Pressing the Down arrow key while the M-Scope is in normal mode opens the access menu. If the Access feature is enabled, meaning the system is currently under password protection, the LCD screen will prompt you to enter the current access code. The M-Scopes factory default access code is 01.

The default access code will remain 01, until it is changed by a user.

• System will respond to an incorrect access code entry by displaying code

mismatch.

Rate Alarm

0.2 m/s t

=

” 0 = Exit s

=

“+”

Access Codes

1 = Master 1

2 = User 2

3 = User 3

4 = User 4

5 = Disable Access 0 = Exit

Code Mismatch!

• After each unsuccessful attempt, the system will display Access Denied and the event will be logged in the statistics counter under the Access alarm counter heading.

There are locations for storing four different access codes, for use by different individuals.

Location 1 is the Master 1 access code location.

Whenever the M-Scope is password protected by Access enable, a Master level password is needed to access:

1. Change the sensitivity level

2. Access the counter menu

3. Change the rate alarm setting

4. Edit the access codes

5. Change/Access Presets

User level access codes allow changes to be made to the volume and contrast.

No access code is needed to turn on or off the unit.

When you open the access menu with a Master level code, you can choose between access enabled and access disabled, by pressing the numeral 5 key.

ACCESS

DENIED

17

16

2. SENSITIVITY MENU

The sensitivity setting determines the unit’s ability to detect metal objects. The higher the sensitivity, the more responsive it will be to relatively small metal concentrations. To adjust the sensitivity, press the sensitivity key (numeral 2).

Use the up/down arrows to adjust the sensitivity setting to any number from 1 to

99. Sensitivity settings should be selected and adjusted based on your facilities particular security needs and operating environment. The M-Scope will retain your sensitivity settings in memory when you turn the power off.

Sensitivity

60 t

=

” 0 = Exit s

=

“+”

Zone Settings

It is possible to adjust the individual zone sensitivities to fine tune the performance of the M-Scope. Once in the sensitivity menu, press any key other than the Up,

Down or 0 button. This will display the Zone select screen. The three bar graphs and numerical reading represent the settings for the TOP (top bar graph), MIDDLE (middle bar graph), and Bottom (bottom bar graph) zones. These settings range from 0.00

(which corresponds to a zone being completely ignored) to a value of 2.00 (which corresponds to a zone having twice the sensitivity as set by the Sensitivity Menu). A value of 1.00 corresponds to a zone having an equal setting as the sensitivity menu.

Pressing numerals adjusts the settings for the zones. Pressing numeral 1, decreases the sensitivity for the top zone. Pressing numeral 2, resets the top zone to a value of 1.00. Pressing numeral 3, increases the sensitivity to only the top zone. In similar fashion, buttons 4,5 and 6 adjust the zone settings for the middle zone. Buttons 7,8 and 9 adjust the settings for the bottom zone. Pressing the Up, Down or 0 numeral, returns to the Sensitivity Menu.

1.00

0.80

1.25

Zone Select

3. CONTRAST MENU

To adjust the LCD display contract press the contract key (numeral 3) when the M-

Scope is in normal operating mode. Use the up/down arrows to adjust the contract.

Contrast settings are automatically saved into memory, as well are the user adjusted settings. Press numeral 0 (of wait ten seconds) to exit the contrast menu.

Contrast Menu

51 t

=

” 0 = Exit s

=

“+”

4. COUNTER MENU / STATISTICS

To view the counters’ contents, press the counter key [numeral 4] while the M-Scope is in normal operating mode. The LCD will display the four counters’ names [people counter, metal target counter, speed violations counter, access alarm counter] and display the values stored in them. To reset the counters, press the numeral 1 key.

Press numeral 0 [or wait ten seconds] to exit the counter menu.

Statistics

People = 0 0 0 0 0 0 0 0

Metal = 0 0 0 0 0 0 0 0

Speed = 0 0 0 0 0 0 0 0

Access = 0 0 0 0 0 0 0 0

1 = Clear 0 = Exit

DISASSEMBLY INSTRUCTIONS

STEP

1

The M-Scope should be powered down (turned off) prior to disassembling the unit, or prior to disconnecting or swapping

any of the transmitter and receiver panels. Re-extend the outriggers as in step 4. Undo the control unit’s latches and remove the control unit. FIG. M — If you are unable to reach the control panel, undo the latches connecting the top and middle panels, and carefully lift the two top panels together with the control unit, and set it down. Remove the panels from the control unit, and set them aside.

FIG. M

STEP

2

Lay out the transport straps on the spot where you will stack the modules for transport. FIG. N — Place the control unit on top of the straps, with the wheel side down. FIG. O

FIG. O

STEP

3

FIG. N

CONTROL PANEL (top view)

Disassemble the remaining panels and set them aside. FIG. P — Reinsert the outriggers into the bases. FIG. Q

FIG. P FIG. Q

STEP

4

If you have the optional leveler proceed with step 4, if not proceed to step 5. Push each of the four leveler legs all the way into the base while holding down their respective actuator pushbuttons, and continue holding them in until you release the actuator pushbuttons. FIG. R — The legs will stay down once the actuators are released.

FIG. R

9

STEP

STEP

5

STEP

6

STEP

7

8

Turn the bases upside down and place them on the control unit. FIG. S

FIG. S

All of the components have a series of projections and indentations that are designed to nest within each other when the components are stacked together for transport. These are called the ‘Stacking Features’. They keep the components from sliding around within the stack when they are strapped together for storage or transport. Make sure the bases are positioned so their stacking features nest on the control unit securely. FIG. T

FIG. T

Stack the panels on top of the bases such that the cones are nearest to the wheel ends of the control unit. FIG. U — Make sure

FIG. U FIG. V

Fasten the straps securely. Stand it up on its wheel end. FIG. W — THE M-SCOPE IS READY FOR TRANSPORT AND STORAGE.

Exercise caution when standing the unit up on its end. The sudden shift in weight may cause the unit to rock away from you.

FIG. W

10

If your car is too small to accommodate the entire unit in one block, simply remove the straps and load the components wherever there is room for them. The entire M-Scope can be loaded into the back seat of a small car. You may wish to unstack the components and load them individually if the entire unit is too heavy for you to lift by yourself. The M-Scope weighs about 90lbs, which is very light for a security portal, but too heavy for most people to safely lift, unaid ed.

ADVANCED FUNCTIONS

You may exit any of these menu modes by pressing the exit key [numeral 0], or by waiting for the ten second keyboard timeout, after which the M-Scope will automatically revert to normal operating mode. Hold the up/down arrow keys for more than one second for rapid increment or decrement.

1-VOLUME MENU

Programmable “Target Detected!” Alarm Length.

When an object is detected, the M-Scope displays “Target Detected!” and sounds an audible alarm. The default duration for this alarm is four seconds. This feature allows this alarm to be adjusted to the user’s preference of one, two, three or four seconds.

Instructions:

Access the Volume Menu by pressing “1” on the keypad and the Volume menu will display as shown at right. Press “1”, “2”, “3” or “4” to change the number of Seconds an alarm will sound when a metal object is detected. The stopwatch symbol displays the current setting. Press “0” to exit the Volume Menu and the M-Scope is ready to detect targets using the displayed setting.

Programmable Alarm Pattern

When the M-Scope detects metal it sounds an audible alarm. This alarm is an adjustable beeping pattern the M-Scope generates. With this feature, there are thirty-two unique alarm patterns to select from.

Instructions:

Access the Volume Menu by pressing “1” on the keypad and the Volume menu will display as shown above. Press “7”, “8” or “9” to change the alarm beep pattern. There’s no visual indication of your choice but the pattern you select is heard while the Volume Menu is displayed. Press “9” to advance to the next available choice and the selection is immediately heard. Continue pressing “9” to advance through additional choices until a satisfactory alarm pattern is found. Press “7” to go back to a previous choice, multiple times if necessary. Pressing “7” or “9” more than thirtytwo times repeatedly will cycle through all of the available choices and will start again at the beginning of the list. Press “8” at any time to reset the alarm pattern to a steady tone and start again at the beginning of the list of available choices. Press “0” to exit the Volume Menu and the M-Scope is ready to detect targets using the selected setting.

Alarm Volume

Adjust the Audible Alarm Volume

Instructions:

Access the Volume Menu by pressing the “1” button. While in the Alarm

Menu, the currently selected volume setting is displayed graphically and can be heard. Press the Up Arrow to increase the volume or press the

Down Arrow to reduce volume. Press “0” to exit the Volume Menu and the

M-Scope is ready to detect targets using the selected setting.

t

=

” 0 = Exit s

=

“+”

:03

TARGET DETECTED!

:04

TARGET DETECTED!

DECREASE

VOLUME

INCREASE

VOLUME

Volume

:04

KEYPAD LEGEND

PRESS

:01

TARGET DETECTED!

:02

TARGET DETECTED!

PREVIOUS

ALARM SOUND

CONSTANT

ALARM SOUND

NEXT

ALARM SOUND

EXIT MENU

ONE SECOND

TWO SECOND

THREE SECOND

FOUR SECOND

RAPI D PU LSE TON E

CONSTANT TON E

PU LSE TON E

15

Zone Indication

The M-Scope has three zones. If one or more of the zones detect target signals strong enough to exceed the alarm threshold, the audio alert will sound, and the LED bar graph will flash several times. The zone indicator light corresponding to the zone where the strongest signal was received will glow red. The zone indicator light for any other zone that detected a signal strong enough to exceed the alarm threshold will repeatedly change its color between red and green at a rate that will tend to make the indicator light appear yellow. The zone indicator light for any zone that did not receive a threshold crossing signal, will continue to glow green. No more than one zone indicator can glow red at a time. No more than two can glow yellow (alternating red and green) at a time. Any combination of green zone indicators is possible.

After finding target(s), the audio alert will continue to beep and the alarm indicator lights will continue to flash for about five seconds before the M-Scope indicates readiness to accept the next subject with a steady green ready light.

Key Stuck Alarm

When any key is held down for more than twenty seconds, the bar graph LEDs go dark, the zone and ready indicators turn red, and the LCD screen shows the words “Key Is Stuck!”. It also shows a representation of the keypad itself with the properly functioning keys shown with dark numerals on light backgrounds, whereas the stuck key shows light numerals on dark background.

Shut Down Sequence

To shut down the M-Scope security gate, press the shut down key [numeral 0]. The LCD will show the words “SHUTDOWN STARTED.” You must press the numeral 1 key within five seconds of the shutdown screen’s appearance to complete the shut down process, or else the system will return to the normal operating mode. The LED bar graph will illuminate singly, in descending order, marking the stages of the shutdown process.

The M-Scope has an automatic self-shutdown safeguard that will prevent complete battery drainage. If the battery level is too low, the unit will automatically shut down and will remain off until the battery is sufficiently charged, or the battery charger is plugged in.

KEY IS STUCK!

1 2 3

4 5 6

7 8 9 t (0) s

Shut Down Unit?

1 = Confirm 0 = Exit

Battery Low Alarm

The M-Scope is powered by sealed lead acid batteries similar to those used in automobiles.

Keeping a load on such batteries when their voltages are too low will eventually destroy them, so the M-Scope design prevents that from happening. When the battery voltage gets too low, [i.e. < 11 Volts ], the LCD announces “Low Battery Alarm” along with the batteries’ voltage level and the time remaining before the unit shuts itself down. No matter how completely discharged the batteries are, the M-Scope will work properly as long as the battery charger is connected.

Shut Down Started

4

14

The battery charger/power supply will fully charge both M-Scope batteries while in use.

Charging time is approximately 24 hours.

M-Scope batteries can also be fully charged and maintained while in storage by using the battery charger/power supply with the optional Y cable assembly (PIN# 1508957). Charging while in storage takes approximately 8 hours.

BATTERY

LOW!!

5

Battery 10.9

Outside Interference

If one or more of the M-Scope’s panels are not ready to detect targets, it could be due to outside interference. A panel not ready to detect is indicated by the zone indicator LED glowing red, and the ready LEDs on the entrance and exit sides of the M-Scope control panel glowing red. The unit will then be ready to detect targets when the panel and ready LEDs turn green. This should only take a few seconds.

If the M-Scope is set up in an area where interference occurs, the unit may not function properly. Try moving the unit to an area where the panel and ready LEDs glow green, and there is an acceptable level of ambient signal as indicated by the LED bargraph.

GETTING STARTED

KEYPAD

the control unit. The two up/down arrows are essentially single function buttons.

The other ten buttons labeled 0 through 9 are all multi-function buttons. Multifunction buttons are annotated with corresponding abbreviations. The following is a list of the complete expressions for those abbreviations.

DIGIT EXPANDED ABBREVIATION

0 Shut down, [On/Off], Exit

5

7

8

9

Rate Alarm menu

User Presets 1

User Presets 2

User Presets 3

ABBREVIATION

On/ Off

VOL

SENS

CON

CNT

RATE

FPSET

PRO1

PRO2

PRO3

The M-Scope should only be used by persons trained and who have a thorough understanding of its operation. If the user of a M-Scope does not follow the operating manual and if the M-Scope is not set up properly it can allow metal objects to pass through undetected.

Some objects may not be detected because of their composition, size and location on the subject. If an undetected object passes through the M-Scope that object may be used as a weapon in a secure area to cause injury or death.

11

12

BASIC START UP OPERATION

STEP

1

Turn the unit on by momentarily pushing the on/off

[numeral 0] button on the control panel keypad. The unit will power up and begin a self diagnostic check.

Ideas by Fisher

Battery 13.4

STEP

2

The LCD will display the Title Screen and the battery voltage during the self-check. The unit will check its seven LED lights on the LED bar graph one at a time, starting with the first (lowest) green one, through the yellow ones all the way up to the last (highest) red one, then back down to the first green one again. After this check is completed, the bar graph display will enter its normal mode, continuously indicating the strength of the received signal it is measuring. Some of this signal may be a representation of various types of electromagnetic noise, and interference.

During the self check, the multi-colored, triple zone, alarm indicator LEDs as well as the two multi-colored ready indicator LEDs, will glow red momentarily. Once the self check ends satisfactorily, they will all change to green.

When the M-Scope passes its self check successfully,

the unit becomes ready to detect targets.

The user selections will be described elsewhere in this document under the Advanced Functions heading.

Most often, the operator will simply turn the unit on, and use the settings already stored in memory. For first time use, the unit will be set at the Factory Preset setting corresponding to numeral 6/high sensitivity level (for more information — see “Presets” pg.16).Note that these

settings may not be appropriate for an operators unique environment and specific security requirements. A thorough understanding of the M-Scopes operation, and most notably, sensitivity settings, is required for effective, accurate metal detection.

The M-Scope is Multi Language Capable:

To change languages: From a fresh start (the Mscope turned off)

1. Press the on button (0) and then rapidly press the down-arrow button and then the up-arrow button.

(This sequence will bring the unit into the first screen of the diagnostics mode.)

Pressing the 0 button again will bring the unit into the main screen of the diagnostics mode. While in this screen:

Pressing the number 1 button will change the menu into English / Pressing the number 2 button will change the menu into German.

Pressing the number 3 button will change the menu into French / Pressing the number 4 button will change the menu into Spanish.

After selecting the desired language pressing the 0 button will change the unit into the normal operating menus.

The M-scope is the normal operating mode at this time.

When the Mscope is shut down the language and other selected options are saved to memory.

DETECTION AND ALARMS

Sensing Subjects in the M-Scope

The metal detection alarm decision-making process begins the moment a subject breaks any one of the six invisible beams of infrared light inside the M-Scope’s passageway; typically one of the three beams at the portal’s entrance. Note that the LED bar graph continuously

displays the received signal’s strength, but the alarm will not be triggered until something enters the security gate and passes through one of the sensors’ light paths.

Going too Fast

Once the M-Scope detects something in the passageway, it begins measuring the elapsed time between when the first beam is crossed upon entering the passageway, and when the second beam is crossed upon exiting the passageway. The measurement of the time it takes for a subject to pass through the gate tells the system how fast the subject was going through the passageway. If the subject exceeds the M-Scope’s selected speed limit; the LCD displays “Speed Violation!”, the audio alert sounds, the zone lights flash red, and the bar graph and ready LEDs flash several times. These events get logged in the system’s internal counters. (for more information — see “Rate Alarm Menu” pg.14)

Going too Slow

If any of the six light beams remains blocked for more than a few seconds, the unit goes into the Photo Detector Blocked alarm mode, featuring red zone and ready indicator

LEDs, sounding audio alert, and a special LCD screen, displaying the words “Photo Diode

Blocked!” along with a graphic display consisting of six circles arranged as three pairs, corresponding to the three pairs of infrared LED and Photodiode sensors. Each individual circle’s interior will either be blank, partially filled in, or entirely filled in, indicating whether the corresponding Photo Detector sensor channel is getting zero signal, a partial signal, or a full strength signal. This feature can be very useful when troubleshooting the

unit.

The LED bar graph also indicates which of the six ‘electric eye’ Photo Detector channels are working properly and which are not, by flashing:

• LED1 if the top light beam on the exit side is blocked

• LED2 flashes when the middle beam on the exit side is blocked

• LED3 flashes if the bottom beam on the exit side is blocked

• LEDs 5,6,7 correspond to the top, middle, and bottom light sensor channels on the entrance side. These LEDs glow steadily (without flashing) to indicate good

Photo

Detector channels in this alarm mode.

Finding Metal Targets Without Speed Violations

While the portal is occupied, the zone lights stay green, the status light glows yellow, and the ready lights glow red. The LED bar graph reflects the received signal strength actively.

If none of the three zones received a target signal strong enough to exceed the current alarm threshold, the zone and ready lights will turn green again when the subject comes out. This event, like all the other events, will be logged automatically, and the M-Scope will be ready to scan the next subject.

SPEED VIOLATION!

Photo Diode Blocked

ONE DIODE BLOCKED

Photo Diode Blocked

CHECK UPPER PANEL

CHECK UPPER PANEL

CHECK UPPER PANEL

ALL DIODES BLOCKED

TARGET DETECTED!