Fluke 123/124

Industrial ScopeMeter

Getting started

GB

Sep 2002

© 2002 Fluke Corporation, All rights reserved. Printed in The Netherlands

All product names are trademarks of their respective companies.

loading

Related Manuals for Fluke 123

Summary of Contents for Fluke 123

  • Page 1
    Fluke 123/124 Industrial ScopeMeter Getting started Sep 2002 © 2002 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective companies.
  • Page 2
    (2x) (2x) (3x) Fluke 123-S/124-S Fluke 123/124 Fluke 123/124 : 1x Fluke 123-S/124-S : 2x Fluke 124/124-S Figure 1-0. ScopeMeter Test Tool Kit…
  • Page 3: Getting Started

    Safety Information: Read First This Getting Started Manual provides basic information The Fluke 123/124 ScopeMeter Test Tool (hereafter on the Fluke 123 and 124 ScopeMeter Test Tools. For referred to as “Test Tool”) complies with: complete operating instructions, refer to the Users •…

  • Page 4
    • Before use check that the selected/indicated and adapters supplied with the Test Tool, or voltage range on the PM8907 matches the indicated as suitable for the Fluke 123/124 local line power voltage and frequency. Test Tool. • For the PM8907/808 universal Battery •…
  • Page 5
    Vdc for DC applications. empty. To reach full charge they must be charged for 5 hours (Fluke 123) or 7 hours (Fluke 124) with the Test Overvoltage Category III refers to distribution level and Tool turned off: fixed installation circuits inside a building.
  • Page 6: Powering/Resetting The Test Tool

    Adjust the Contrast of the display. Resetting the Test Tool to the factory (default) settings: To change the brightness and contrast in Fluke 124: Turn power off, then press and hold the Switch from cursor to display control.

  • Page 7: Reading The Screen

    The bottom line displays the ranges / div and the power indicator (line or battery). Note: When battery powered, the battery indicator Fluke 123 informs you about the condition of the battery from full to empty: Fluke 124 Menu area (C): Displays the menu that provides choices Figure 1.

  • Page 8: Making Menu Selections

    Fluke 123/124 Getting Started Making Menu Selections 100Ω Selection of a function in the menu is done as follows: A menu pops up after operation of, for instance, the SCOPE MENU key. Use the arrow keys to highlight the desired measurement function.

  • Page 9
    COM are at the same potential. Note: Fluke 124 is supplied with a 10:1 Oscilloscope Figure 3. Grounding with Unshielded Ground Lead. Probe. Use of a Probe is recommended when you measure high frequency signals in circuits For measurements at higher frequencies or low levels, use with a high impedance.
  • Page 10: Displaying An Unknown Signal With Connect-And-View

    Fluke 123/124 Getting Started Freezing the Screen Displaying an Unknown Signal with Connect-and-View™ You can freeze the screen (Waveforms and Readings) with the HOLD/RUN key. This allows you read the screen The Connect-and-View™ function enables hands-off while the Test Tool has been disconnected from the operation to display complex unknown signals.

  • Page 11
    Getting Started Scope Measurements on Input A and B Then choose Peak-to-Peak Reading for Input B: Open the INPUT B Menu. Highlight ON. Turn INPUT B on. Highlight PEAK ..The dots … behind PEAK indicate that a submenu will follow on this selection.
  • Page 12: Making Cursor Measurements

    Changing the Time Base: Increase or Decrease the number of Making Cursor measurements periods. Cursors are present in Fluke 124. Cursors allow you to Positioning the traces: make precise digital measurements on live and on saved waveforms. Select A MOVE or B MOVE.

  • Page 13
    Getting Started INPUT A Menu / INPUT B Menu INPUT A Menu / INPUT B Menu Measure signal height difference between two points of time and • In the INPUT A Menu you can choose from measure time difference between these many measurement functions.
  • Page 14: Scope Menu

    • PROBE AC ADJUST. For adjustment of 10:1 • The function keys F1, F2, and F3 give access voltage probes other than the probe supplied to submenus: with Fluke 124. This is necessary for correct high frequency measurements. SCOPE OPTIONS … SCOPE MODE TRIGGER …

  • Page 15: User Options Menu

    Getting Started User Options Menu User Options Menu SAVE / PRINT menu • USER OPTIONS gives submenus to • SAVE / PRINT lets you save Screens and configure the Test Tool to your personal taste: Setups to memory, to recall them later •…

  • Page 16
    Fluke 123/124 Getting Started…

This manual is also suitable for:

124

Fluke 123 Область метр

Производитель:

Модель:

123

Дата:

Категория:

Группа:

Описание:

Информация

Dual input oscilloscope
Vertical
Frequency response
DC coupled:
Excluding probes and test leads:
DC to 20 MHz (-3 dB)
With STL120 1:1 shielded test leads:
DC to 12.5 MHz (-3 dB)
DC to 20 MHz (-6 dB)
With PM 8918 10:1 Probe (optional
accessory): DC to 20 MHz (-3 dB)
AC coupled (LF roll off)
Excluding probes and test leads:
<10 Hz (-3 dB)
With STL120: <10 Hz (-3 dB)
With PM 8918: <1 Hz (-3 dB)
Rise time
Excluding probes and test leads:
<17.5 ns
Input impedance
Excluding probes and test leads:
1 MW//12 pF
With BB120: 1 MW//20 pF
With STL120: 1 MW//225 pF
With PM 8918: 10 MW//15 pF
Sensitivity: 5 mV to 500V/div
Display modes: A, -A, B, -B
Max input voltage
A, B: 600V rms up to 200 kHz,
derating to 6V rms @ 20 MHz
Max floating voltage
From any terminal to ground:
600V rms up to 400 Hz
Resolution: 8 bit
Vertical accuracy: ±(1% of reading
+ 0.05 range/div)
Max vertical move: ±4 divisions
Horizontal
Acquisition modes
Normal: Equivalent sampling: 20 ns
to 500 ns/div; real time sampling:
1 ms to 5s/div
Single (real time): 1 ms to 5s/div
Roll (real time): 1s to 60s/div
Sampling rate (for both channels
simultaneously): For repetitive
signals (equivalent sampling) up to
1.25 GS/s; real time (normal and
single): 1 ms to 5 ms/div, 25 MS/s;
10 ms to 5s/div, 5 MS/s
Time base accuracy
Equivalent sampling: ±(0.4%
of reading +0.04 time/div)
Real time sampling: ±(0.1%
of reading +0.04 time/div)
Glitch detection: ³40 ns
@ 20 ns to 5 ms/div; ³200 ns
@ 10 ms to 5s/div
Glitch detection is always active
Horizontal move, 10 divisions.
Permits shifting of the display
from 0 to 10 division of pre-trigger.
Trigger point will always be visible.

показать больше

Руководство пользователя

Hасто́льная кни́га тип:

Руководство пользователя

Страницы:

83

Размер:

1.84 Mbytes (1933945 Bytes)

Язык:

english

Пересмотр:

Hасто́льная кни́га ID:

Дата:

Качество:

Электронный документ, ни сканирование, очень хорошо читается.

Дата загрузки:

2016 01 26

MD5:

06bfdf8754072d733a7d08576f198abd

Загрузки:

1082

Информация

Declaration of Conformity

1
Unpacking the Test Tool Kit

2
Safely Using the Test Tool

4
1 Using The Test
Tool …
7
Goal of this Chapter

7
Powering the Test Tool

7
Resetting the Test Tool

8
Changing Backlight

9
Reading the Screen

10
Making Selections in a Menu

11
Looking at the Measurement
Connections …
12
Displaying an Unknown Signal with Connect-and View™
… 13
Making
Measurements …
14
Freezing the
Screen …
16
Holding a Stable Reading

16
Making Relative
Measurements …
17
Selecting Auto/Manual
Ranges …
18
Changing the Graphic Representation on the Screen
… 18
TrendPlotting a Waveform

22
Acquiring the Waveform

23
Triggering on a Waveform

27
Saving and Recalling a Setup and a Screen

32
Making Cursor
Measurements …
35
Using the 10:1 Probe for High Frequency
Measurements … 38
Using a Printer

39
Using FlukeView® Software

41
2 Maintaining the Test
Tool …
43
About this Chapter

43
Cleaning the Test
Tool …
43
Storing the Test
Tool …
43
Charging the Rechargeable Battery
Pack …
44
Keeping Batteries in Optimal Condition

45
Replacing and Disposing of the Rechargeable Battery Pack
… 46
Using and Adjusting 10:1 Scope Probes

47
Calibrating the Test
Tool …
49
Parts and Accessories

49
3 Tips and
Troubleshooting …
53
Goal of this Chapter

53
Using the Tilt
Stand …
53
Resetting the Test Tool

54
Changing the Information
Language …
54
Changing the
Display …
55
Changing Date and Time

56
Saving Battery Life

57
Changing the Auto Set
Options …
58
Using Proper Grounding

59
Solving Printing and Other Communication Errors
… 60
Battery Testing of Fluke
Accessories …
60
4
Specifications …
61
Introduction

61
Dual Input Oscilloscope

62
Dual Input
Meter …
65
Cursor readout (Fluke 124)

68
Miscellaneous

69
Environmental

70
Safety

70

показать больше

Руководство по техническому обслуживанию

Hасто́льная кни́га тип:

Руководство по техническому обслуживанию

Страницы:

77

Размер:

1.62 Mbytes (1697807 Bytes)

Язык:

english

Пересмотр:

4

Hасто́льная кни́га ID:

4822 872 00743

Дата:

Качество:

Электронный документ, ни сканирование, очень хорошо читается.

Дата загрузки:

2016 01 26

MD5:

39798c0a31354b1504bed94ce32f6d3c

Загрузки:

701

Информация

Declaration of Conformity

1
Unpacking the Test Tool Kit

2
Safely Using the Test Tool

4
1 Using The Test Tool

7
Goal of this
Chapter …
7
Powering the Test
Tool …
7
Resetting the Test Tool

8
Changing
Backlight …
9
Reading the
Screen …
10
Making Selections in a
Menu …
11
Looking at the Measurement Connections

12
Input A

12
Input B

12
COM

12
Displaying an Unknown Signal with Connect-and-View™
… 13
Making Measurements

14
Freezing the Screen

16
Holding a Stable Reading

16
Making Relative Measurements

17
Selecting Auto/Manual Ranges

18
Changing the Graphic Representation on the Screen
… 18
Changing the Amplitude

18
Changing the Time Base

18
Positioning the Waveform on the Screen

19
Smoothing the Waveform

20
Displaying the Envelope of a Waveform

21
TrendPlotting a
Waveform …
22
Starting a TrendPlot™ function

22
Changing the TrendPlot Reading

23
Turning Off the TrendPlot Display

23
Acquiring the Waveform

23
Making a Single
Acquisition …
23
Recording Slow Signals over a Long Period of Time
… 25
Selecting AC-Coupling

26
Reversing the Polarity of the Displayed Waveform
… 26
Triggering on a Waveform

27
Setting Trigger Level and Slope

27
Selecting the Trigger Parameters

28
Isolated
Triggering …
29
Triggering on Video Signals

29
Triggering on a Specific Video Line

31
Saving and Recalling a Setup or a Screen

32
Saving
Screens …
32
Recalling
Screens …
33
Deleting Screens

33
Using a
Printer …
34
Using FlukeView® Software

36
2 Maintaining the Test Tool

37
About this
Chapter …
37
Cleaning the Test Tool

37
Storing the Test Tool

37
Charging the Ni-Cd Battery Pack

38
Keeping Batteries in Optimal Condition

39
Replacing and Disposing of the Ni-Cd Battery Pack
… 40
Using and Adjusting 10:1 Scope Probes

41
Calibrating the Test Tool

43
Parts and
Accessories …
43
Service Manual

43
Standard
Accessories …
43
Optional Accessories

46
3 Tips and Troubleshooting

47
Goal of this
Chapter …
47
Using the Tilt Stand

47
Resetting the Test Tool

48
Changing the Information Language

48
Changing the Display

49
Adjusting the Screen Contrast

49
Setting the Grid Display

49
Changing Date and Time

50
Saving Battery Life

51
Setting the Power Down Timer

51
Changing the Auto Set Options

52
Using Proper
Grounding …
53
Solving Printing and Other Communication Errors
… 54
4 Specifications

55
Introduction

55
Dual Input
Oscilloscope …
56
Vertical …
56
Horizontal

57
Trigger

57
Advanced Scope Functions

58
Dual Input
Meter …
59
Input A and Input
B …
59
Input A

60
Advanced Meter Functions

61
Miscellaneous …
62
Environmental

63
Safety

64

показать больше

Руководство по техническому обслуживанию

Hасто́льная кни́га тип:

Руководство по техническому обслуживанию

Страницы:

174

Размер:

7.12 Mbytes (7464388 Bytes)

Язык:

english

Пересмотр:

Hасто́льная кни́га ID:

4822 872 05389

Дата:

2003 02 01

Качество:

Отсканированы документу, все читается.

Дата загрузки:

2020 07 22

MD5:

798e05075681c736483ff7a88df7f5da

Загрузки:

576

Информация

Safety Instructions … 1-1
1.1 Introduction … 1-3
1.2 Safety Precautions … 1-3
1.3 Caution and Warning Statements … 1-3
1.4 Symbols used in this Manual and on Instrument … 1-3
1.5 Impaired Safety … 1-4
1.6 General Safety Information … 1-4
Characteristics … 2-1
2.1 Introduction … 2-3
2.2 Dual Input Oscilloscope … 2-3
2.2.1 Vertical … 2-3
2.2.2 Horizontal … 2-4
2.2.3 Trigger … 2-4
2.2.4 Advanced Scope Functions … 2-5
2.3 Dual Input Meter … 2-5
2.3.1 Input A and Input B … 2-5
2.3.2 Input A … 2-8
2.3.3 Advanced Meter Functions … 2-9
2.4 Cursor Readout (Fluke 124) … 2-9
2.5 Miscellaneous … 2-9
2.6 Environmental … 2-11
2.7 Service and Maintenance … 2-12
2.8 Safety … 2-12
2.9 EMC Immunity … 2-14
Circuit Descriptions … 3-1
3.1 Introduction … 3-3
3.2 Block Diagram … 3-3
3.2.1 Channel A, Channel B Measurement Circuits … 3-4
3.2.2 Trigger Circuit … 3-4
3.2.3 Digital Circuit … 3-5
3.2.4 Power Circuit … 3-6
3.2.5 Start-up Sequence, Operating Modes … 3-7
3.3 Detailed Circuit Descriptions … 3-9
3.3.1 Power Circuit … 3-9
3.3.2 Channel A — Channel B Measurement Circuits … 3-15
3.3.3 Trigger Circuit … 3-20
3.3.4 Digital Circuit and ADC’s … 3-25
Performance Verification … 4-1
4.1 Introduction … 4-3
4.2 Equipment Required For Verification … 4-3
4.3 How To Verify … 4-3
4.4 Display and Backlight Test … 4-4
4.5 Input A and Input B Tests … 4-5
4.5.1 Input A and B Base Line Jump Test … 4-6
4.5.2 Input A Trigger Sensitivity Test … 4-7
4.5.3 Input A Frequency Response Upper Transition Point Test … 4-8
4.5.4 Input A Frequency Measurement Accuracy Test … 4-9
4.5.5 Input B Frequency Measurement Accuracy Test … 4-10
4.5.6 Input B Frequency Response Upper Transition Point Test … 4-10
4.5.7 Input B Trigger Sensitivity Test … 4-11
4.5.8 Input A and B Trigger Level and Trigger Slope Test … 4-12
4.5.9 Input A and B DC Voltage Accuracy Test … 4-14
4.5.10 Input A and B AC Voltage Accuracy Test … 4-16
4.5.11 Input A and B AC Input Coupling Test … 4-17
4.5.12 Input A and B Volts Peak Measurements Test … 4-18
4.5.13 Input A and B Phase Measurements Test … 4-19
4.5.14 Input A and B High Voltage AC/DC Accuracy Test … 4-20
4.5.15 Resistance Measurements Test … 4-21
4.5.16 Continuity Function Test … 4-22
4.5.17 Diode Test Function Test … 4-23
4.5.18 Capacitance Measurements Test … 4-23
4.5.19 Video Trigger Test … 4-24
Calibration Adjustment … 5-1
5.1 General … 5-3
5.1.1 Introduction … 5-3
5.1.2 Calibration number and date … 5-3
5.1.3 General Instructions … 5-3
5.2 Equipment Required For Calibration … 5-4
5.3 Starting Calibration Adjustment … 5-4
5.4 Contrast Calibration Adjustment … 5-6
5.5 Warming Up & Pre-Calibration … 5-7
5.6 Final Calibration … 5-7
5.6.1 HF Gain Input A&B … 5-7
5.6.2 Delta T Gain, Trigger Delay Time & Pulse Adjust Input A … 5-9
5.6.3 Pulse Adjust Input B … 5-10
5.6.4 Gain DMM (Gain Volt) … 5-10
5.6.5 Volt Zero … 5-12
5.6.6 Zero Ohm … 5-12
5.6.7 Gain Ohm … 5-13
5.6.8 Capacitance Gain Low and High … 5-14
5.6.9 Capacitance Clamp & Zero … 5-14
5.6.10 Capacitance Gain … 5-15
5.7 Save Calibration Data and Exit … 5-15
Disassembling the Test Tool … 6-1
6.1. Introduction … 6-3
6.2. Disassembling Procedures … 6-3
6.1.1 Required Tools … 6-3
6.2.2 Removing the Battery Pack … 6-3
6.2.3 Removing the Bail … 6-3
6.2.4 Opening the Test Tool … 6-3
6.2.5 Removing the Main PCA Unit … 6-5
6.2.6 Removing the Display Assembly … 6-6
6.2.7 Removing the Keypad and Keypad Foil … 6-6
6.3 Disassembling the Main PCA Unit … 6-6
6.4 Reassembling the Main PCA Unit … 6-8
6.5 Reassembling the Test Tool … 6-8
Corrective Maintenance … 7-1
7.1 Introduction … 7-3
7.2 Starting Fault Finding. … 7-4
7.3 Charger Circuit … 7-4
7.4 Starting with a Dead Test Tool … 7-6
7.4.1 Test Tool Completely Dead … 7-6
7.4.2 Test Tool Software Does not Run. … 7-7
7.4.3 Software Runs, Test Tool not Operative … 7-7
7.5 Miscellaneous Functions … 7-8
7.5.1 Display and Back Light … 7-8
7.5.2 Fly Back Converter … 7-9
7.5.3 Slow ADC … 7-10
7.5.4 Keyboard … 7-11
7.5.5 Optical Port (Serial RS232 Interface) … 7-11
7.5.6 Channel A, Channel B Voltage easurements … 7-11
7.5.7 Channel A Ohms and Capacitance Measurements … 7-13
7.5.8 Trigger Functions … 7-14
7.5.9 Reference Voltages … 7-15
7.5.10 Buzzer Circuit … 7-15
7.5.11 Reset ROM Circuit … 7-16
7.5.12 RAM Test … 7-16
7.5.13 Power ON/OFF … 7-17
7.5.14 PWM Circuit … 7-17
7.5.15 Randomize Circuit … 7-17
7.6 Loading Software … 7-17
7.7 Configuration of CPLD-chip D470 … 7-17
Circuit Diagrams … 9-1
9.1 Introduction … 9-1
9.2 Schematic Diagrams … 9-2
Modifications … 10-1
10.1 Software modifications … 10-1
10.2 Hardware modifications … 10-1

показать больше

Технический паспорт

Hасто́льная кни́га тип:

Технический паспорт

Страницы:

4

Размер:

729.75 Kbytes (747266 Bytes)

Язык:

english

Пересмотр:

A

Hасто́льная кни́га ID:

J0661

Дата:

Качество:

Электронный документ, ни сканирование, очень хорошо читается.

Дата загрузки:

2014 11 30

MD5:

7d2cac54627692048572f02481b27222

Загрузки:

680

Руководство пользователя

Hасто́льная кни́га тип:

Руководство пользователя

Страницы:

98

Размер:

118.98 Kbytes (121835 Bytes)

Язык:

english

Пересмотр:

Hасто́льная кни́га ID:

Дата:

Качество:

Электронный документ, ни сканирование, очень хорошо читается.

Дата загрузки:

2023 03 20

MD5:

a339c682aa67a35f8c3b6ea3874aa0a7

Загрузки:

65

Руководство по техническому обслуживанию

Hасто́льная кни́га тип:

Руководство по техническому обслуживанию

Страницы:

96

Размер:

1.99 Mbytes (2082892 Bytes)

Язык:

english

Пересмотр:

Hасто́льная кни́га ID:

4822 872 05398

Дата:

Качество:

Электронный документ, ни сканирование, очень хорошо читается.

Дата загрузки:

2014 11 29

MD5:

c87ad484e83e45f4a08037ec9a5bb2fb

Загрузки:

1801

Информация

Limited Warranty & Limitation of
Liability …
ii
Introduction and Safety
Instructions … 1-1
1.1 Introduction to Service Manual

1-3
1.2 Safety

1-3
1.2.1
Introduction …
1-3
1.2.2 Safety
Precautions …
1-3
1.2.3 Caution and Warning
Statements …
1-3
1.2.4 Symbols used in this Manual and on Instrument
… 1-4
1.2.5 Impaired
Safety …
1-4
1.2.6 General Safety
Information …
1-4
Characteristics
… 2-1
2.1
Introduction …
2-3
2.2 Dual Input
Oscilloscope …
2-3
2.2.1
Vertical …
2-3
2.2.2 Horizontal

2-4
2.2.3 Trigger

2-4
2.2.4 Advanced Scope
Functions …
2-5
2.3 Dual Input
Meter …
2-5
2.3.1 Input A and Input B

2-5
2.3.2 Input A

2-8
2.3.3 Advanced Meter Functions

2-9
2.4 Cursor Readout (Fluke 124,
125) …
2-10
2.5 Harmonics Measurements (Fluke
125) …
2-10
2.6 Field Bus Measurements (Fluke 125)

2-11
2.7 Miscellaneous

2-11
2.8
Environmental …
2-12
2.9 Service and Maintenance

2-13
2.10 Safety

2-13
2.11 EMC Immunity

2-15
Performance
Verification … 3-1
3.1
Introduction …
3-3
3.2 Equipment Required For Verification
… 3-3
3.3 How To
Verify …
3-4
3.4 Display and Backlight
Test …
3-4
3.5 Input A and Input B
Tests …
3-5
3.5.1 Input A and B Base Line Jump Test
… 3-6
3.5.2 Input A Trigger Sensitivity Test

3-8
3.5.3 Input A Frequency Response Upper Transition Point Test
… 3-9
3.5.4 Input A Frequency Measurement Accuracy Test
… 3-9
3.5.5 Input B Frequency Measurement Accuracy
Test … 3-10
3.5.6 Input B Frequency Response Upper Transition Point
Test … 3-11
3.5.7 Input B Trigger Sensitivity Test

3-12
3.5.8 Input A and B Trigger Level and Trigger Slope Test
… 3-13
3.5.9 Input A and B DC Voltage Accuracy Test
… 3-16
3.5.10 Input A and B AC Voltage Accuracy Test
… 3-18
3.5.11 Input A and B AC Input Coupling Test
… 3-19
3.5.12 Input A and B Volts Peak Measurements Test
… 3-20
3.5.13 Input A and B Phase Measurements Test
… 3-21
3.5.14 Harmonics (Fluke 125)

3-21
3.5.15 Input A and B High Voltage AC/DC Accuracy
Test … 3-22
3.5.16 Resistance Measurements Test

3-24
3.5.17 Continuity Function Test

3-25
3.5.18 Diode Test Function
Test …
3-26
3.5.19 Capacitance Measurements
Test …
3-26
3.5.20 Video Trigger
Test …
3-27
Calibration
Adjustment … 4-1
4.1
General …
4-3
4.1.1
Introduction …
4-3
4.1.2 Calibration number and
date …
4-3
4.1.3 General
Instructions …
4-3
4.2 Equipment Required For
Calibration …
4-4
4.3 Starting Calibration Adjustment

4-4
4.4 Contrast Calibration Adjustment

4-6
4.5 Warming Up &
Pre-Calibration …
4-7
4.6 Final Calibration

4-7
4.6.1 HF Gain Input A&B

4-7
4.6.2 Delta T Gain, Trigger Delay Time & Pulse Adjust Input
A … 4-9
4.6.3 Pulse Adjust Input B

4-10
4.6.4 Gain DMM (Gain Volt)

4-10
4.6.5 Volt
Zero …
4-12
4.6.6 Zero
Ohm …
4-12
4.6.7 Gain
Ohm …
4-13
4.6.8 Capacitance Gain Low and High

4-14
4.6.9 Capacitance Clamp &
Zero …
4-14
4.6.10 Capacitance Gain

4-15
4.7 Save Calibration Data and
Exit …
4-15
Disassembling the Test Tool
… 5-1
5.1.
Introduction …
5-3
5.2. Disassembling Procedures

5-3
5.1.1 Required
Tools …
5-3
5.2.2 Removing the Battery Pack

5-3
5.2.3 Removing the Bail

5-3
5.2.4 Opening the Test Tool

5-3
5.2.5 Removing the Main PCA
Unit …
5-5
5.2.6 Removing the Display
Assembly …
5-6
5.2.7 Removing the Keypad and Keypad Foil
… 5-6
5.3 Disassembling the Main PCA
Unit …
5-6
5.4 Reassembling the Main PCA
Unit …
5-8
5.5 Reassembling the Test
Tool …
5-8
List of Replaceable Parts
… 6-1
6.1
Introduction …
6-3
6.2 How to Obtain
Parts …
6-3
6.3 Service Centers

6-3
6.4 Final Assembly Parts

6-4
6.5 Main PCA Unit Parts

6-6
6.6 Service Tools

6-7

показать больше

Руководство по техническому обслуживанию

Hасто́льная кни́га тип:

Руководство по техническому обслуживанию

Страницы:

170

Размер:

5.26 Mbytes (5519764 Bytes)

Язык:

english

Пересмотр:

3

Hасто́льная кни́га ID:

4822 872 05375

Дата:

Качество:

Электронный документ, ни сканирование, очень хорошо читается.

Дата загрузки:

2014 11 29

MD5:

d1e4ef72a9bc1d3fa26a274826207797

Загрузки:

900

Информация

1 Safety Instructions

1-1
1.1
Introduction …
1-3
1.2 Safety
Precautions …
1-3
1.3 Caution and Warning
Statements …
1-3
1.4
Symbols …
1-3
1.5 Impaired Safety

1-4
1.6 General Safety
Information …
1-4
2 Characteristics

2-1
2.1
Introduction …
2-3
2.2 Dual Input
Oscilloscope …
2-3
2.2.1 Vertical

2-3
2.2.2 Horizontal

2-4
2.2.3 Trigger

2-4
2.2.4 Advanced Scope
Functions …
2-5
2.3 Dual Input
Meter …
2-5
2.3.1 Input A and Input B

2-5
2.3.2 Input A

2-8
2.3.3 Advanced Meter
Functions …
2-8
2.4 Miscellaneous

2-9
2.5 Environmental

2-10
2.6 Service and Maintenance

2-11
2.7 Safety

2-11
2.8 EMC Immunity

2-12
3 Circuit Descriptions

3-1
3.1
Introduction …
3-3
3.2 Block Diagram

3-3
3.2.1 Channel A, Channel B Measurement
Circuits … 3-4
3.2.2 Trigger Circuit

3-4
3.2.3 Digital Circuit

3-5
3.2.4 Power Circuit

3-6
3.2.5 Start-up Sequence, Operating Modes
… 3-7
3.3 Detailed Circuit
Descriptions …
3-9
3.3.1 Power Circuit

3-9
3.3.2 Channel A — Channel B Measurement Circuits
… 3-15
3.3.3 Trigger Circuit

3-20
3.3.4 Digital Circuit

3-25
4 Performance
Verification …
4-1
4.1
Introduction …
4-3
4.2 Equipment Required For Verification
… 4-3
4.3 How To
Verify …
4-3
4.4 Display and Backlight Test

4-4
4.5 Input A and Input B Tests

4-5
4.5.1 Input A and B Base Line Jump
Test … 4-6
4.5.2 Input A Trigger Sensitivity Test
… 4-7
4.5.3 Input A Frequency Response Upper Transition Point
Test … 4-8
4.5.4 Input A Frequency Measurement Accuracy Test
… 4-8
4.5.5 Input B Frequency Measurement Accuracy Test
… 4-9
4.5.6 Input B Frequency Response Upper Transition Point Test
… 4-10
4.5.7 Input B Trigger Sensitivity Test
… 4-10
4.5.8 Input A and B Trigger Level and Trigger Slope
Test … 4-11
4.5.9 Input A and B DC Voltage Accuracy Test
… 4-14
4.5.10 Input A and B AC Voltage Accuracy Test
… 4-15
4.5.11 Input A and B AC Input Coupling
Test … 4-16
4.5.12 Input A and B Volts Peak Measurements
Test … 4-17
4.5.13 Input A and B Phase Measurements Test
… 4-18
4.5.14 Input A and B High Voltage AC/DC Accuracy
Test … 4-19
4.5.15 Resistance Measurements
Test …
4-20
4.5.16 Continuity Function Test

4-21
4.5.17 Diode Test Function Test

4-22
4.5.18 Capacitance Measurements Test
… 4-22
4.5.19 Video Trigger
Test …
4-23
5 Calibration Adjustment

5-1
5.1 General

5-3
5.1.1
Introduction …
5-3
5.1.2 Calibration number and
date …
5-3
5.1.3 General
Instructions …
5-3
5.2 Equipment Required For
Calibration …
5-4
5.3 Starting Calibration Adjustment

5-4
5.4 Contrast Calibration Adjustment

5-6
5.5 Warming Up & Pre-Calibration

5-7
5.6 Final Calibration

5-7
5.6.1 HF Gain Input A&B

5-7
5.6.2 Delta T Gain, Trigger Delay Time & Pulse Adjust Input
A … 5-9
5.6.3 Pulse Adjust Input A (firmware V01.00 only)
… 5-10
5.6.4 Pulse Adjust Input
B …
5-11
5.6.5 Gain DMM (Gain
Volt) …
5-11
5.6.6 Volt
Zero …
5-13
5.6.7 Zero Ohm (firmware V01.00
only) … 5-13
5.6.8 Gain
Ohm …
5-14
5.6.9 Capacitance Gain Low and
High … 5-15
5.6.10 Capacitance Clamp &
Zero …
5-15
5.6.11 Capacitance
Gain …
5-16
5.7 Save Calibration Data and
Exit …
5-16
6 Disassembling the Test Tool
… 6-1
6.1.
Introduction …
6-3
6.2. Disassembling Procedures

6-3
6.1.1 Required Tools

6-3
6.2.2 Removing the Battery Pack

6-3
6.2.3 Removing the Bail

6-3
6.2.4 Opening the Test Tool

6-3
6.2.5 Removing the Main PCA
Unit …
6-5
6.2.6 Removing the Display
Assembly …
6-6
6.2.7 Removing the Keypad and Keypad
Foil … 6-6
6.3 Disassembling the Main PCA
Unit …
6-6
6.4 Reassembling the Main PCA Unit

6-8
6.5 Reassembling the Test
Tool …
6-8
7 Corrective Maintenance

7-1
7.1
Introduction …
7-3
7.2 Starting Fault Finding.

7-4
7.3 Charger
Circuit …
7-4
7.4 Starting with a Dead Test Tool

7-6
7.4.1 Test Tool Completely
Dead …
7-6
7.4.2 Test Tool Software Does not Run.
… 7-7
7.4.3 Software Runs, Test Tool not Operative
… 7-7
7.5 Miscellaneous
Functions …
7-8
7.5.1 Display and Back Light

7-8
7.5.2 Fly Back
Converter …
7-9
7.5.3 Slow
ADC …
7-10
7.5.4
Keyboard …
7-11
7.5.5 Optical Port (Serial RS232
Interface) …
7-11
7.5.6 Channel A, Channel B Voltage Measurements
… 7-12
7.5.7 Channel A Ohms and Capacitance
Measurements … 7-13
7.5.8 Trigger
Functions …
7-14
7.5.9 Reference
Voltages …
7-15
7.5.10 Buzzer
Circuit …
7-15
7.5.11 Reset ROM Circuit (PCB version <8
only) … 7-16
7.5.12 RAM Test

7-16
7.5.13 Power
ON/OFF …
7-16
7.5.14 PWM
Circuit …
7-17
7.5.15 Randomize Circuit

7-17
7.6 Loading
Software …
7-17
8 List of Replaceable
Parts …
8-1
8.1
Introduction …
8-3
8.2 How to Obtain
Parts …
8-3
8.3 Final Assembly Parts

8-4
8.4 Main PCA Unit Parts

8-6
8.5 Main PCA Parts

8-7
8.6 Accessory Replacement Parts

8-24
8.7 Service
Tools …
8-24
9 Circuit
Diagrams …
9-1
9.1
Introduction …
9-3
9.2 Schematic
Diagrams …
9-4
10 Modifications

10-1
10.1 Software modifications

10-1
10.2 Hardware
modifications …
10-1

показать больше

Добавить комментарий

Компактный промышленный прибор Fluke 123 Industrial Scopemeter® — представляет собой надежный двухканальный осциллограф, мультиметр и самописец в одном, доступном по цене и удобном в работе, приборе.

Fluke 123 предназначен для оперативного решения задач проверки и поиска неисправностей в приводах двигателей постоянного и переменного тока, датчиках и исполнительных механизмах, линиях электропитания, трансформаторах и преобразователях, линейных и импульсных схемах управления и контроля.

  • Двухканальный цифровой осциллограф с полосой пропускания 20 МГц и двухвходовый цифровой мультиметр позволяют обнаруживать неисправности длительностью от наносекунды до нескольких месяцев;

  • Цифровой мультиметр действующего (true-rms) значения с разрядностью дисплея в 5000 отсчетов при точности 0,5% обеспечивает 26 типов измерений, включая напряжение постоянного тока, действующее напряжение переменного тока, частоту в Гц, скважность, длительность импульсов, фазовый сдвиг двух сигналов, ток, температуру, пик-фактор, дБВ, дБм, сопротивление, прозвонка цепей, характеристики диодов, емкость.

  • Двухканальная функция TrendPlot™ отслеживает сбои за счет непрерывной записи показаний в течение времени от считанных минут до нескольких суток. Записываются максимальные и минимальные показания с отметками даты и времени. Двухканальность обеспечивает поиск по критериям «причина и результат»;

  •  Работа по технологии Connect-and-View™ обеспечивает надежное отображение сигнала на дисплее без необходимости нажимать на кнопки — даже для самых сложных сигналов, включая приводы двигателей и видеосигналы. Это удобное новшество от Fluke экономит время, затрачиваемое на поиск неисправностей, и помогает минимизировать время простоя производственных систем. Изменения сигналов мгновенно распознаются, а настройки постоянно корректируются для устойчивой индикации;

  • Прибор Fluke 123 ScopeMeter позволяет быстро и удобно замерить параметры поочередно в целом ряде точек — в этом он выгодно отличается от обычных индикаторных приборов с автоматической настройкой и выбором диапазонов;

  • Интуитивная легкость использования с уникальной возможностью «все измерения за один тест». Один и тот же щуп предназначен для осциллографических наблюдений, измерений на мультиметре, измерений сопротивления и емкости и прозвонки электрических цепей;

  • Большой и яркий флуоресцентный дисплей с фоновой подсветкой и холодным катодом обладает отличным контрастом и прекрасно виден как в темноте, так и при ярком дневном свете;

  • Удобная эргономичная форма прибора и его небольшой вес 1100 гр. обеспечивают портативность и удобство эксплуатации даже одной рукой. Ударопрочная конструкция корпуса с чехлом-футляром гарантируют длительную и надежную работу в производственных условиях;

  • Время непрерывной работы от штатных батарей — до 5 часов. Индикатор разряда батареи и быстрая перезарядка;

  • Совместим с широким набором аксессуаров Fluke, включая зажимы для больших токов и температурные пробники;

  • Возможная опционально поставка с оптически изолированным интерфейсом RS-232 для ПК и принтера, а также программное обеспечение FlukeView® для работы под Windows упрощают задачи документирования и обработки результатов измерений;

  • Прочный компактный кейс (поставляется отдельно).

Понравилась статья? Поделить с друзьями:
  • Flugger грунтовка инструкция по применению
  • Fludrex таблетки из эмиратов инструкция на русском
  • Fludex sr инструкция по применению на русском языке
  • Fluconazole инструкция по применению и цена
  • Fluconazole 150 инструкция по применению