Fondital antea ctn 24 инструкция

Fondital Antea 24kW Range Installation, Use & Maintenance Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

IST 03 C 469 — 01

ANTEA CONDENSING

GB

Gas fired wall-mounted condensing boiler

Antea

24kW & 28kW Range

INSTALLATION,

USE & MAINTENANCE

MANUAL

MADE IN ITALY

loading

Related Manuals for Fondital Antea 24kW Range

Summary of Contents for Fondital Antea 24kW Range

  • Page 1
    IST 03 C 469 — 01 ANTEA CONDENSING Gas fired wall-mounted condensing boiler Antea 24kW & 28kW Range INSTALLATION, USE & MAINTENANCE MANUAL MADE IN ITALY…
  • Page 2: General Information

    Natural Gas Fondital Antea KC 24KW Combi SEDBUK SAP 2009 88.1% G.C.N° 47 309 06 Fondital Antea KC 24KW Combi SEDBUK SAP 2009 89.1% G.C.N° 47 309 07 Benchmark Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions by competent persons and that it meets the requirements of the appropriate Building…

  • Page 3: Precautions

    Dear Customer, Thank You for choosing and buying a High quality Fondital Product. <Please read these instructions carefully in order to properly install, operate, and maintain the equipment. The Manufacturer recommends that Customers contact competent and qualified personnel only for maintenance and repair operations. All repair and maintenance should be carried out by a Gas Safe registered company/engineer with the relevant qualifications for this appliance.

  • Page 4: General Information For The Installer, Maintenance Technician And Users

    The commissioning of the boiler and any subsequent works carried out on the appliance must be effected by an appropriately qualified technician or an approved Fondital Helpline Service Centre technician. Damage and/or injury caused by incorrect installation or use, or non-observance of the manufacturer’s instructions shall relieve the manufacturer from any and all contractual and extra-contractual liability.

  • Page 5: Product Conformity

    The warnings contained in this chapter have been written for the appliance user, the installer and the service engineer. 1.2. Product conformity FONDITAL S.p.a. declare that all its products are manufactured to a high specification and in compliance with the relevant standards. All FONDITAL boilers are CE certified and possess technical and functional characteristics that comply with the following standards: UNI EN 297 for GAS-FIRED CENTRAL HEATING BOILERS TYPE B OF NOMINAL HEAT INPUT ≤ 70 kW EN 483 for GAS-FIRED CENTRAL HEATING BOILERS TYPE C OF NOMINAL HEAT INPUT ≤ 70 kW…

  • Page 6: Quick Guide Operating Instructions

    8. Set the desired temperature on the (optional) room thermostat in the building. The boiler is now ready to operate. If the boiler shuts down, press boiler reset button (4 in fig. 1). If the boiler does not restart, contact contact the Fondital Helpline UK.

  • Page 7: Table Of Contents

    CONTENTS General information …………………………………………..2 Precautions …………………………………………….3 General information for the installer, maintenance technician and users ………………..4 1.1. General warnings …………………………………………..4 1.2. Product conformity …………………………………………5 Quick guide operating instructions ……………………………………..6 Instructions for the user ……………………………….9 2.1. Control panel …………………………………………….9 2.2. LCD …………………………………………….

  • Page 8
    7.4. Reassemble the boiler ………………………………………… 46 Component replacement ………………………………47 8.1. Electrode …………………………………………….47 8.2. Gas injectors …………………………………………..48 8.3. Fan ………………………………………………48 8.4. Flue temperature probe ……………………………………….48 8.5. Gas valve …………………………………………….48 8.6. Fuse ………………………………………………48 8.7. Electronic board ………………………………………….. 48 8.8.
  • Page 9: Instructions For The User

    INSTRUCTIONS fOR THE USER Fondital is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance.

  • Page 10: Lcd

    8. Time clock The time clock is for central heating control only. The clock is provided with a selector switch with three positions: Position “I” CONSTANT: in this position, the clock circuit is always closed (switch on), therefore the boiler will constantly on and will only shut off upon the request of the room thermostat (if installed) or the heating thermostat;…

  • Page 11: Interpreting Boiler Status From Lcd Display Indications

    2.3. Interpreting BOILER STATUS from LCD DISPLAY INDICATIONS Normal operation Boiler in STANDBY mode Boiler in SUMMER mode No function active The flow water temperature is displayed Boiler in WINTER mode No function active The flow water temperature is displayed Boiler in CENTRAL HEATING ONLY mode No function active The flow water temperature is displayed…

  • Page 12: Boiler Operation

    Shutdown due to CH low water level Shutdown due to CH low water level Return probe fault Remote control (optional) connection failure Fan failure Max. number of resume attempts from remote exceeded Table 2 — BOILER STATUS — LCD DISPLAY INDICATIONS in the event of malfunction 2.4.

  • Page 13: Freeze Protection Function

    WARNING A flow restrictor is installed within the boiler, which limits domestic hot water output flow rate. This limit is: 13 litres per minute (for model KC 24) and 14 litres per minute (for model KC 28). Domestic hot water temperature supplied depends on the DHW temperature setting and on the quantity requested by the user. The temperature of the water mains supply temperature is also a determining factor.

  • Page 14: Boiler Shutdown

    If you do not, when the pressure increases, the safety valve may activate and discharge water. b) the pressure gauge (7, fig. 1) shows a pressure of 1-1.3 bar Should the boiler shut down again, contact the fondital helpline UK 01329 828555 or a Gas Safe registered engineer with appropriate compe- tence for service.

  • Page 15: Shutdown Due To Fan Malfunction

    — E15 for the return probe. In this case the boiler does not work. Should the boiler not re-start and still remain in the above status, contact the Fondital helpline UK or CORGI registered engineer with appropri- ate competence for service.

  • Page 16: Maintenance

    By law, only qualified personnel are allowed to service the boiler. The Manufacturer recommends that Customers contact the fondital Helpline UK service centre for maintenance and repairs. For boiler breakdowns and advice on repair carried out by a Gas Safe Technician, refer to section 6 – Maintenance.

  • Page 17: Technical Features And Dimensions

    TECHNICAL fEATURES AND DIMENSIONS 3.1. Technical features The boiler is equipped with a fully pre-mixed gas burner. The following model is available: — KC: condensing boiler with sealed chamber and forced draught, supplying CH water and for instant DHW production; This version is available with two power ratings: — KC 24: with heat input of 24.9 kW…

  • Page 18: Dimensions

    3.2. Dimensions 152,5 top view bottom view Gas inlet (1/2”) CH return (3/4”) CH flow (3/4”) Condensate drain DHW outlet (1/2”) 3-bar safety valve drain cock Cold water inlet (1/2”) Dimensions for connection to base hydraulic kit (option) fig. 4…

  • Page 19: Boiler Layout

    3.3. Boiler layout Condensate trap Modulating gas valve Safety thermostat CH temperature probe Modulating fan CH temperature probe Main condensing heat exchanger Ignition electrode Air purging device Combustion air intake system Flue gas discharge system Flue gas analysis ports Flue gas thermostat on flue gas duct Flue gas thermostat on heat exchanger Flame sensing electrode Expansion vessel…

  • Page 20: Table 5 — General Specifications, Model Kc

    KC MODEL Equipment category II2H3P II2H3P Minimum CH system pressure Maximum CH system pressure DHW min. pressure DHW max. pressure DHW specific flow rate (Δt 30 K) EN 625 l/min 13.5 15.0 Electric power supply – voltage / frequency V — Hz 230 — 50 230 — 50 Power mains supply fuse…

  • Page 21: Instructions For Installation

    INSTRUCTIONS fOR INSTALLATION 4.1. Installation standards This is an II2H3P category boiler and must be installed in compliance with laws and standards enforced in the country of installation, which are herein considered as entirely transcribed. 4.2. Reference standard In UK, the installation must be carried out by a Gas Safe Registered Installer. To check for authorised qualified engineers please contact Gas Safe register 0800 408 5500 .

  • Page 22: System Details

    4.3. System details 4.3.1. Central heating circuit The boiler is designed for use in a sealed central heating system in accordance with the requirements of BS 5449 and BS 6798. The system should be designed to operate with flow temperatures of up to 78 °C. When designing the system, the pump head, expansion vessel size, mean radiator temperature, ect.

  • Page 23: Positioning The Boiler

    4.4.2. Positioning the boiler 25 cm Each boiler is supplied with a paper template (fig. 8), within its packaging, allow- ing arrangement of CH pipe system, DHW pipe system, gas supply pipe system and air intake/flue gas discharge system before actually installing the boiler.

  • Page 24: Boiler Room Ventilation

    4.4.3. Boiler room ventilation The boiler has sealed combustion chamber. Combustion air is not drawn from boiler room or area surrounding the boiler therefore specific recommendations for ventilation in the area of the appliance is not required. It is mandatory to install the boiler in an adequate room following laws and standards applicable in the country of installation, which are considered as fully transcribed in this manual.

  • Page 25: Installation (Authorised Personnel Only)

    Accessories and spare parts for installation and service procedures are to be supplied by the Manufacturer. Under no circumstances should parts that are not type tested and approved by the manufacturer be used for service or repair of fondital appliances. 4.5.1.

  • Page 26: Hydraulic Connection

    To prevent the main exchanger pipes from getting clogged with any material accumulated in the system it is necessary to install a filter which can be inspected (Y-shaped type) with Ø 0.4mm-mesh span, on the heating return pipe, before the boiler. When connecting the boiler to gas supply network, install an appropriately sized and made gasket (fig.

  • Page 27
    Termination to a External termination via purpose made soak-away internal discharge branch Boiler Boiler e.g. sink waste — downstream 500 mm min Pipe must terminate above water level but below surrounding dish Holes in the soak-away surface must face away from the building Termination to a Termination to a drain or gully…
  • Page 28: Air Intake And Flue Gas Discharge System

    Should the boiler repeatedly shut down, it is necessary to have air/flue gas system ducts inspected, as they might be obstructed or inadequate to flue gas discharge into the atmosphere. for the air intake/flue gas discharge systems, only specific, fondital approved, condensate acid-resistant pipes and systems must be used, suitable for condensing boilers.

  • Page 29: Configuration Of Air Intake And Flue Gas Discharge Ducts

    4.6. Configuration of air intake and flue gas discharge ducts Type B23 Boiler intended for connection to an existing flue system external to the boiler room. Combustion air is taken directly from the boiler room itself while flue gas is conveyed to the outside. The boiler does not require any cowl while it must be equipped with a fan mounted before the combustion chamber/heat exchanger.

  • Page 30
    Type C33 KC 24 Minimum permissible length of vertical coaxial pipes is 1 meter, not including the first elbow connected to the boiler. Maximum permissible length of Ø 100/60 mm vertical coaxial pipes is 10 meters not including the first elbow connected to the boiler. Maximum permissible length of Ø…
  • Page 31: Ø 80 Mm Air Intake And Flue Gas Discharge Via Split Ducts

    4.6.2. Ø 80 mm air intake/flue gas discharge via split ducts The information given is with reference to air intake/flue gas discharge ducts made from smooth, rigid pipes approved and supplied by the manufacturer. Installation types C43 — C53 — C83 KC 24 Minimum permissible length of air intake duct is 1 meter.

  • Page 32: Connection To Electrical Mains

    4.7. Connection to electrical mains The boiler is supplied with a three-core power cable, already connected to the electronic board and it is provided with a safety clamp. The boiler is to be connected to a 230V-50Hz electrical power supply. When connecting the boiler to power mains, follow correct phase / neutral polarity sequence.

  • Page 33: Installation Of The (Optional) External Probe And «Weather Compensation» Operation

    default values for default values for default values for default values for Configurable Parameter TSP0 = 1 TSP0 = 2 TSP0 = 3 TSP0 = 4 value range KC 24 Natural gas KC 28 Natural gas KC 24 Propane KC 28 Propane TSP0 0 — 5 Boiler type and default data chart…

  • Page 34: Setting Parameters

    4.11 Setting parameters Configurable Parameter factory set Notes value range 1 = 24 kW natural gas; 2 = 28 kW natural gas; 0 to 4 Boiler output selection 3 = 24 kW propane; 4 = 28 kW propane 1 to 3 1= combi boiler with plate heat exchanger for DHW Boiler type selection Value P5 ÷…

  • Page 35: Table 9 — Configurable Limits For Parameters And Default Values

    Display of max calculated flow temperature (with thermoregulation only) Display of flow temperature setpoint for zone 2 Display of current flow temperature for zone 2 Display of flow temperature setpoint for zone 3 Display of current flow temperature for zone 3 Display of flow temperature setpoint for zone 4 Display of current flow temperature for zone 4 Display of DHW plate heat exchanger temperature…

  • Page 36: Filling The System

    4.12. filling the system Once all boiler connections have been completed, CH system can be filled. The procedure is to be cautiously carried out, following each step: — open the air purging valves on all radiators and verify the boiler automatic valve operation; — Gradually open the relevant filling loop connection, checking any automatic bleeding valves installed in the system properly work;…

  • Page 37: Conversion To Other Gas Types And Burner Adjustment

    4.14. Conversion to other gas types and burner adjustment This boiler is built to run on the type of gas specified on the order, which is shown on the packaging and on the boiler rating plate. Any later conversion is to be exclusively carried out by qualified personnel, using using only manufacturer-approved accessories accessories and following the procedure and adjustment instructions for an accurate boiler setting-up.

  • Page 38
    LE QUOTE RIQUADRATE CON SONO DA CONSIDERARSI CRITICHE E SOGGETTE A Color STATO DISEGNO VERSIONE Materiale fig. 18b fig. 18a Salvo diversa indicazione tolleranze generali da Scala Peso Finitu ISO 2768 mK Disegnato il Disegnato e veri cato A termini di legge ci riserviamo la proprietà del presente disegno con divieto di riproduzione totale o parziale senza la nostra autorizzazione.
  • Page 39
    fig. 21…
  • Page 40: Testing The Boiler

    TESTING THE BOILER 5.1. Preliminary checks Before testing the boiler, it is recommended to check the following: — the flue gas discharge duct and the relative terminal are installed in conformity with the instructions: with the boiler operating there must be no leakage of combustion by-products from any of the gaskets;…

  • Page 41: Maintenance

    MAINTENANCE Any maintenance and repair work must only be carried out by qualified personnel. The manufacturer recommends Customers to contact the fondital Helpline UK for maintenance and repairs, they are best trained for that procedure. Appropriate boiler maintenance ensures efficient operation, environment preservation, and safety for people, animals and objects.

  • Page 42: Checking Combustion Efficiency

    6.3. Checking combustion efficiency 6.3.1. flue cleaning function The boiler features a flue cleaning function which must be used to measure in situ combustion efficiency and to set the burner. To activate the flue cleaning function, press and hold the buttons “info” and “Reset” simultaneously for 3 seconds. The flow temperature and the symbol shown on the LCD.

  • Page 43: Wiring Diagram

    6.4. Wiring diagram SEXT SBC 0CREMOTO04 P17 = 1 P17 = 0 P17 = 3 9: Fase NO 10: Fase NC 11: Neutro 2 3 4 5 6 7 8 9 10 11 9 10 11 9 10 11 1516 17 ELECTRIC PANEL QUADRO ELETTRICO 230Vac…

  • Page 44
    DK: water pressure switch VG: gas valve 0CREMOTO04 (PIN 3 and 4): OpenTherm fL/TM: flow switch/timer P: boiler pump remote control SS: DHW NTC probe 10K Ohm at 25 °C MDV: electric deviating valve SEXT (PIN 5 and 6): external NTC probe 10K E: ignition/flame detection electrode B=3435 Ohm at 25 °C B=3977…
  • Page 45: Available Head

    6.5. Available head MODEL KC 24 V1 Pump speed I (min) 1000 1200 V2 Pump speed II flow rate [l/h] V3 Pump speed III (max) fig. 24 MODEL KC 28 1000 1200 1400 V1 Pump speed I (min) flow rate [l/h] flow rate [l/h] V2 Pump speed II V3 Pump speed III (max)

  • Page 46: Routine Servicing

    ROUTINE SERVICING 7.1. Checks before servicing Before servicing the boiler, always check the following: • Check the entire flue system, including joints and the flue terminal. Be sure that all of the assembly is correct and there are no blockages •…

  • Page 47: Component Replacement

    COMPONENT REPLACEMENT Note: any servicing activity must be carried out by qualified personnel only. Before replacing any boiler component, be sure the boiler is isolated from electric supply and the gas cock is closed. Always ensure that the boiler is cool. After replacing any gas carrying components, or opening any gas connections, always check for gas tightness.

  • Page 48: Gas Injectors

    8.2. Gas injectors See 4.14 (Conversion to other gas types and burner adjustment) 8.3. fan (fig. 28) • Remove the burner/panel/fan assembly as described in 7.2 • Remove the mixer from the fan, unscrewing the three socket head capscrews with a 5 mm Allen key •…

  • Page 49: Three-Way Valve Motor

    8.8. Three-way valve motor (fig. 30) • Access behind the front casing, as described in 7.2 • Remove the three-way valve motor by unplugging the electrical connection and removing the holding clip upwards • Remove the motor pulling it forwards •…

  • Page 50: Pressure Relief Valve

    8.16. Pressure relief valve • Access behind the control panel as described in 7.2 and drain the boiler heating circuit • Disconnect the pressure relief valve outlet pipe • Extract the retaining clip and lift the valve out of the pump housing •…

  • Page 51: Spare Part List

    SPARE PART LIST fig. 31…

  • Page 52
    fig. 32…
  • Page 53
    Item Code Description No. of pieces per pack 6INSETER00 Insert for thermostat with o-ring 6VALSFAU01 Automatic relief valve 6SONDNTC08 Bayonet NTC flue gas probe 6SCAMCON06 Heat exchanger condensing 24 kW 6SCAMCON08 Heat exchanger condensing 28 kW 6SIFRACO04 Compact condensate trap 6BRUCOND02 Condensing burner 24 kW 6BRUCOND03…
  • Page 54: Table Of Fault Codes

    TABLE Of fAULT CODES BOILER STATUS MALfUNCTION PROBABLE CAUSE SOLUTION Check gas supply Gas supply failure Check gas supply cock or gas network safety valve intervention Burner does not ignite Gas valve is disconnected Reconnect it Gas valve is faulty Replace it PCB is faulty Replace it…

  • Page 55
    BOILER STATUS MALfUNCTION PROBABLE CAUSE SOLUTION Fault code E06 shown on LCD display. DHW probe is disconnected Reconnect it Normal operation is restored automatically when the faults DHW probe is not working causing the alarm state are rectified. DHW probe is faulty Replace it Fault code E15 shown on LCD display.
  • Page 58
    Affix your analyser print out here…
  • Page 60
    — www.fondital.it e mail: admin@fondital.co.uk The manufacturer reserves the right to implement any necessary and/or useful variation to products, without modifying fundamental characteristics. Uff. Pubblicità Fondital IST 03 C 469 — 01 Marzo 2012 (03/2012) Fondital UK helpline 01329 828555…

Характеристики

Максимальная мощность, кВт
18

Режим работы
Отопление/ГВС

Термостат защиты от перегрева
Да

Тип установки
Настенный

Электрическая мощность, Вт
73

Антиблокировка насоса
Да

Вес, кг
26

Возможность подключения бойлера ГВС
Да

Возможность установки в жилой зоне
Да

Высота, см
70

Габариты (ВхШхГ), см
70x40x25

Гарантия
2 года

Глубина, см
25

Горелка
Модулируемая

Защита от замерзания
Да

Интуитивно понятное управление
Да

Камера сгорания
Открытая

Максимальное давление в контуре ГВС, Атм
6

Максимальное давление отопительного контура, Атм
3

Максимальный расход природного газа, м/ч
2.59

Максимальный расход сжиженного газа, кг/ч
1.93

Манометр
Да

Минимальная полезная мощность, кВт
10.5

Минимальное давление в контуре ГВС, Атм
0.5

Минимальное давление отопительного контура, Атм
0.5

Напряжение сети, В
220

Низкий уровень NOx
Да

Номинальное давление природного газа, мбар
20

Погодозависимая автоматика
Да

Присоединительный контур отопления, дюйм
3/4

Присоединительный размер газопровода, дюйм
1/2

Присоединительный размер дымохода, мм
80

Производительность ГВС 30С. л/мин
10.6

Производство
Италия

Расширительный бак
Да

Самодиагностика
Да

Страна бренда
Италия

Тип котла
Энергозависимый

Тип теплообменника
Раздельный

Удлинение дымохода раздельного, мм
80

Функциональный ЖК дисплей
Да

Циркуляционный насос
Да

Частота тока, Гц
50

Ширина, см
40

Электронная система управления
Да

Характеристики

Основные характеристики
Производитель Fondital
Производство Россия
Гарантия производителя 12 месяцев
Тип котла Традиционный
Расход электроэнергии 75 Вт
Установка Настенный
Количество контуров Двухконтурный
Камера сгорания Открытая / атмосферный
Мощность 24 кВт
Энергонезависимый Нет
Вид топлива Метан
Тип теплообменника Раздельный, Первичный, Вторичный
Технические параметры
Напряжение в сети 220В/50Гц
Эффективность (КПД) % 90
Максимальное давление 5 бар
Расширительный бак 7 л
Работа на сжиженном газе (опция) Да
Устанавливаются в помещениях Индивидуальные жилые коттеджи, Частное автономное отопление, Обогрев небольшой дачи, Компактных котельных
Характеристики отопления
Площадь отопления 240 кв. м.
Циркуляционный насос Есть
Min температура отопления 35 °C
Max температура отопления 78 °C
Теплообменник Медный
Характеристики водоснабжения
Теплообменник ГВС Нерж. сталь
Производительность ГВС 10 л/мин
Тип приготовления ГВС Проточный
Встроенный накопительный бойлер Нет
Max температура ГВС 57 °C
Min температура ГВС 35 °C
Режим «Лето» Есть
Подключение и габаритные размеры
Вход контура отопления 3/4 дюйма
Выход контура отопления 3/4 дюйма
Подключение газа 1/2 дюйма
Вход контура ГВС 1/2 дюйма
Выход контура ГВС 1/2 дюйма
Высота 700 мм
Ширина 400 мм
Глубина 250 мм
Объём, м³ 0,07
Вес без упаковки 24.5 кг

Основное описание

Fondital

Настенный котел с открытой камерой сгорания и естественной тягой с проточным нагревом горячей воды

Новый односкоростной насос со встроенным воздухоотводчиком

PLUS

  • Компактный котел глубиной всего лишь 250 мм
  • Жидкокристалический дисплей с автодиагностикой
  • Многофункциональное реле для подключения к системам с зонными клапанами, к системам управления внешним насосом или к удаленному блоку сигнализации аварийных сигналов
  • Работа с датчиком температуры наружного воздуха (опция)

Газовый котел Fondital ANTEA PLUS CTN 24 отзывы

Получить заказ можно следующими способами:

● Самовывоз из пункта выдачи

Адрес ближайшего пункта выдачи можно на странице Контакты

Оплатите покупку наиболее комфортным для Вас способом:

● Онлайн оплата на сайте

Онлайн оплата банковской картой доступна только после подтверждения заказа менеджером. На указанную Вами почту придет письмо с уведомлением о смене статуса заказа и ссылкой на страницу оплаты.

● Оплата наличными средствами или банковской картой

Таким способом можно оплатить не только в пункте выдачи, но и курьеру службы доставки — курьер имеет дистанционный терминал оплаты для банковских карт.

● Оформление товара в рассрочку или кредит

Заявку на кредит можно оформить как в нашем магазине, так и дистанционно не выходя из дома.

● Банковский перевод

Квитанцию на оплату по реквизитам организации можно получить у менеджера магазина дистанционным способом или лично.

● Оплата для юридических лиц с НДС

Для юридических лиц предусмотрены взаиморасчеты под разные системы налогообложения — более подробно Вас может проконсультировать менеджер магазина

Нашли дешевле? Снизим цену!

Пункты самовывоза


Адрес:

г. Москва, ул. Бибиревская, д. 2, корп. 1


Телефон:

8 (800) 444-79-34

  • ✅ Купить котел газовый Fondital Antea Plus CTN 24 гарантией от производителя.
  • ✅ Цена на котел газовый Fondital Antea Plus CTN 24 в интернет магазине с доставкой .
  • ✅ Котел газовый Fondital Antea Plus CTN 24 внедорого в наличии.

Заинтересовал товар?


Оставьте свою заявку или позвоните нам по номеру

8 (800) 444-79-34

Отзывы о магазине


Егор Мартынов

15 Августа 2022

С приближением холодов решил утеплить полы на лоджии. На сайте makipa.ru мне предложили двухжильный Solelec и терморегулятор. Друг, порекомендовавший этот магазин, сказал, что здесь можно заказать и монтаж теплых полов. Уточнил. И это действительно так. Заказ и монтаж оплатил на сайте. Это очень удобно. Ребята из службы сервиса пол уложили аккуратно и быстро. Результатом доволен. Магазин понравился. Рекомендую!


Татьяна Карпова

15 Августа 2022

В этот магазин я зашла не случайно. Многое в нашем доме куплено в Макипе: сантехника, счетчики, муж покупал какие-то инструменты. Этот магазин мне нравится не только большим ассортиментом, но и тем, что можно не бродить часами по сайту, а просто обратится к менеджеру и он подберет вам все необходимое. Когда пришло время покупать аксессуары для ванной, я знала, где смогу купить все предметы в одном стиле. Сразу обратилась к консультанту и рассказала, что мне нужно. В результате, купила набор аксессуаров Emco, а также ершик для унитаза, полотенцедержатель, бумагодержатель этой же фирмы. Доставку не оформляла, заказ забрала через три дня в пункте выдачи заказов. В очередной раз благодарю сотрудников Макипа за внимание и профессионализм!


Артемий Иванов

15 Августа 2022

Этот магазин открыл для себя случайно, почитав отзывы о нем в Интернете. Народ не жалеет для него добрых слов. Сегодня и я к ним присоединяюсь. Работа на сайте организована четко и грамотно, сотрудники – настоящие спецы, отвечающие на самые сложные технические вопросы. Купил здесь биде с установкой. Это еще одна приятная фишка Макипы. Результатом доволен. Однозначно буду рекомендовать этот магазин друзьям.


Серафим Матвеев

15 Августа 2022

Заказывали в makipa.ру сплит-систему, подбирали вместе с менеджером их. Нужна была качественная система, которая работала бы в летний период максимально эффективно. Выбирали между системами Haier, взяли модель 2U18FS2ERA(S). Было несколько вопросов по комплектующим к этой системе, менеджер ответил, все стало понятным. Через интернет-магазин система выходит реально дешевле. Отгрузили нашу покупку в течение двух дней, точно уже и не помню, но быстро. Оплату провели тоже через сайт с карты. Устанавливал наш мастер, все документы на сплит были, включая инструкцию. Очень довольны качественной работой магазина Makipa.


Лейла Шестакова

15 Августа 2022

Когда вышел из строя полотенцесушитель, соседка, узнав о моей беде, посоветовала не бегать по городу, а сразу зайти на сайт компании Макипа. До этого я о ней ничего не слышала. Сразу обратила внимание на огромный ассортимент товаров в разных категориях по разным ценам. Сама разобраться в этом разнообразии не смогла, поэтому обратилась к менеджеру. Через несколько минут мне предложили на выбор несколько моделей с примерно одинаковыми характеристиками. Хотела выбрать чёрный, но не устроила цена. Остановилась на модели Royal Thermo Классика П5. Удобный, компактный и по разумной цене. Доставку и заказ оформила на сайте. Полотенцесушитель доставили вовремя. Установил его сантехник из ЖЭУ. Работает нормально. Претензий к качеству нет. Магазин понравился, но хотелось бы, чтобы компания открыла и оффлайн-магазин: некоторые товары хотелось бы увидеть «вживую», а не на фото.

Оставить отзыв

Понравилась статья? Поделить с друзьями:
  • Folder facade влаго ветрозащита для фасада инструкция по применению
  • Foldable s89 инструкция квадрокоптер на русском
  • Foldable push up board инструкция на русском
  • Fold drone lf606 инструкция на русском языке скачать
  • Fold drone ages 14 инструкция на русском