Газовый котел kiturami 35 квт инструкция

  1. Manuals
  2. Brands
  3. Kiturami Manuals
  4. Boiler
  5. KRH-35B
  6. Technical information and installation servicing instructions
  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

Technical information and Installation Servicing Instructions

Model

* KRH — 35B (40.6 kW)

┃┃┃┃┃

1페이지

loading

Related Manuals for Kiturami KRH-35B

Summary of Contents for Kiturami KRH-35B

  • Page 1
    Technical information and Installation Servicing Instructions Model * KRH — 35B (40.6 kW) ┃┃┃┃┃ 1페이지…
  • Page 2: Table Of Contents

    CONTENTS 1) OVERALL VIEW 1-1 GENERAL INFORMATIONGeneral Information******************************************* 2) PRODUCT DESCRIPTION 2-1 SPECIFICATION ******************************************* 3) INSTALLATION 3-1 STANDARD INSTALLATION ******************************************* 3-2 INSTALLING FLUE ******************************************* 3-3 HEATING PIPE CONNECTION ******************************************* 3-4 TOTAL PIPE WORK ******************************************* 3-5 CONNECTION ELECTIRICITY ******************************************* 4) TEST WORKING 4-1 CHECK LIST BEFORE SWITCHING ON ******************************************* 4-2 HOW TO IGNITE FIREWOOD INITIALLY…

  • Page 3
    IMPORTANT TIPS * Read this instruction manual carefully before you start to install and use the boiler, what is the condition of the efficient use and the proper installation of the appliance. * This instruction manual is an integral and important equipment of the boiler. They should be kept through the whole operation life of the boiler and should be read carefully as it includes full information and warnings concerning safety during installation, operation and maintenance, which must be observed.
  • Page 4
    1. OVERALL VIEW 1-1 INFORMATION These instructions are suitable for KRH Series hybrid Wood fired boiler; Do not forget this instruction. To ensure the correct installation, commissioning and servicing of domestic central heating system. NEW CONCEPT & NEW TECHNOLOGY 1. Exhaust / intake phase modulation system As ventilation quantity is modulated by MCU that checks the rising speed of water temperature in real time, the optimum combustion condition and long heating are realized.
  • Page 5: Specification

    2. PRODUCT DESCRIPTION 1-1 SPECIFICATION Model : KRH-35A Model POWER SOURCE AC 220V ~ 230V/ 50Hz DIMENSION (Wx Dx H) 740 X 1,343 X 1,380 mm WEIGHT (kg) INSTALLATION TYPE Floor standing type FUEL TYPE Wood & oil HETING AREA (㎡) Room Control FLUE 5페이지…

  • Page 6: Standard Installation

    3. INSTALLATION 3-1 STANDARD INSTALLATION 1. dimension 용량 1000 165 214 1051 KRH-35A 2. Pipe size CAPACYTI DMH OUTLET CH SUPPLY CH OUTLET SAFETY VALVE DHW INLET KRH — 35A 1/2″ (15) 1/2″ (15) 1 1/4 » (32) 1 1/4 » (32) 1/2″…

  • Page 7: Installing Flue

    3. INSTALLATION 3-2 INSTALLING FLUE ▶ In case of existing flue ▶ In case of no existing flue Flue Flue Flue Install it with downslope 5 degrees Drainage device Install the device with inclination of 5 degrees * In using a flue, Check the status of flue every 6 months, * Install the flue 3m above the boiler along with replace it when there is much soot in it.

  • Page 8
    3. INSTALLATION 3-2 INSTALLING FLUE ▶ If there is a tall building or an obstacle within 1 m of the flue, install the flue 1 meter higher than the roof of the building. — Install the flue at a location 3 meters or higher than the top of the boiler — The height of the installed flue should be greater than three times the horizontal length.
  • Page 9: Heating Pipe Connection

    3. INSTALLATION 3-3 HEATING PIPE CONNECTION 2. Connect the Domestic Hot Water Inlet with water 1. Install the expansion tank 1m higher than the top of storage tank, not with the water pipe directly. boiler. In installing it in a basement, Install it 1m higher than the floor pipe.

  • Page 10: Total Pipe Work

    3. INSTALLATION 3-4 TOTAL PIPE WORK 3-4-1 STANDARD PIPE WORK <DOWNWARD PLUMBING TYPE> T unit for preventing rainwater Water supply Hot water outlet 3M or longer Nitrogen tank (20L or more) Expansion pipe( higher than heating Safety pipe) valve Hot water Hot water Heating outlet…

  • Page 11
    3. INSTALLATION 3-5 CONNECTING ELETRICITY 3-4-1 STANDARD PIPE WORK <UPWARD PLUMBING TYPE> T unit for preventing rainwater Water supply Hot water outlet 3M or longer Nitrogen tank (20L or more) Air vent Safety valve Safety Pressur Expansion pipe( higher than heating valve e gauge Hot water…
  • Page 12
    3. INSTALLATION 3-5 CONNECTING ELETRICITY 3-5-1 CONNECTING WIRES ※ This appliance is designed on AC 220V ~ 230V/ 50Hz. This work of connecting wires is required by a qualified electrician. 1. Make sure that the earth connection is required for safety uses from any electric leakage or short-circuit. 2.
  • Page 13
    4. TEST WORKING 4-1 HOW TO INSTALL THE ROOM THERMOMETER Set the room temperature by rotating the room thermostat (CTR-6070) clockwise. Push the Mode button and select Wood or Wood/Oil. In the Wood mode, manually light the firewood and, in the Wood/Oil mode, push the Fire button in order to light the firewood.
  • Page 14: Check List Before Switching On

    4. TEST WORKING 4-2 CHECK-LIST BEFORE SWITCHING-ON 1. Before switching-on, please check the followings after finishing the installation of boiler, flue, pipes, and electricity. ① Use the power outlet exclusive for the boiler, and be cautious for leakage. The operating power is AC 230 and 50 Hz. Operate the boiler only after checking the voltage. Do not touch the power cable or operate the boiler with wet hands to avoid electric shock.

  • Page 15
    4. TEST WORKING 4-2 CHECK-LIST BEFORE SWITCHING-ON Precautions 1. In a power failure, be careful about overheating. If electric power is not supplied, the blower and circulation pump do not work and the risk of overheating and fire is increased. 2.
  • Page 16
    4. TEST WORKING 4-3 FIRST IGNITION OPERATION 1. Check the electrical 3. Check the firewood and oil 2. Check the type of fuel and supply. change the fuel if necessary Compleat……………………… Compleat……………….Compleat…………………… …. …. 5. Check the exhaust 4. Measure the firewood and 6.
  • Page 17: How To Ignite Firewood Initially

    4. TEST WORKING 4-4 HOW TO IGNITE HYBRID FIREWOOD INITIALLY 1. Manual ignition 1) Ignite the tinder (Beongaetan) Put the «Beongaetan» in the central part of the firebox, add the firewood, and light the Beongaetan using papers, etc. Keep the ashtray hole open until the firewood is ignited to a certain level. When the firewood is completely lit close the hole. 2) Ignite the wood Stack completely dried wood (thin wood) in a zigzag pattern in the firebox and light the firewood using paper or cardboard box scraps.

  • Page 18
    4. TEST WORKING 4-5 HOW TO CLEAN THE BOILER Remove the water residue from the oil tank once a year. PEEP HOLE You should replace the boiler’s oil filter once or twice a year just as you replace your car’s oil filter every three months.
  • Page 19: Direction For Assembly 5-1 Disassembly

    5. DIRECTION FOR ASSEMBLY 5-1 PART EXPLODED VIEW 19페이지…

  • Page 20: Part List

    5. DIRECTION FOR ASSEMBLY 5-2 PART NAME Model Part Name(English) Korean ERP Code KF-35A Side case (L) 케이싱 우측 Side case (R) 케이싱 좌측 Mica 운모 Top cover 상부카바 Bottom case 바닥 케이스 Panel (side) 측면 판넬 Panel (back) 후면 판넬 Front case 케이스…

  • Page 21
    6. MAINTENANCE GUIDE 6-1 BURNER, CONTROLLER, FAN 1. Burner replacement ① lock the door with the lock handle ② loosen a screw with a driver for replacement or repair. ③ After separate the cover, isolation the connector from burner connector. ④…
  • Page 22
    6. MAINTENANCE GUIDE 6-1 BURNER, CONTROLLER, FAN 2. Main controll repalcement ① separate the control cover with a driver from the main control ② keep the separated cover from the body ③ After separating the cover, isolate the connector from the main control ④…
  • Page 23
    6. MAINTENANCE GUIDE 6-1 BURNER, CONTROLLER, FAN 3. Blower FAN repalcement ① loosen screws at blower fan ② after that separate the cover with driver ③ open the fan cover(*be careful of connector) ④ separate 2p connector of the fan ⑤…
  • Page 24: Main Controller Part Name

    6. FUNCTIONS OF THE CONTROLLER 6-2 MAIN CONTROLLER PART NAME(CTC-3500) 1. Electric features Voltage and frequency : AC 220V, 50Hz / 60Hz Allowable Voltage : AC 220V ± 15% Electric consumption : AC ma Electric Power consumption : AC ma Ambient temperature range : -10~65℃…

  • Page 25
    6. FUNCTIONS OF THE CONTROLLER 6-3 MAIN CONTROLLER PART NAME(CTR-6070) Model : CTR — 6070 2. POWER BUTTON 1. HEATING Heating water TEMPERATURE Operation temperature Power 3. HEATING 4. HEATING BUTTON Room TEMPERATURE CONTROL Bath 5. BATH BUTTON Displays current water temperature in boiler. Also, displays in figures about the 1.
  • Page 26
    6. FUNCTIONS OF THE CONTROLLER 6-4 ROOM POWER OFF (REGARDLESS OF MODE) * Functions of the room controller when POWER OFF (REGARDLESS OF MODE) Function Perception means Operation Resume Indication Circulation pump It will automatically resume perception by the water sensor(under 10℃) «ON»…
  • Page 27
    6. FUNCTIONS OF THE CONTROLLER 6-4 ROOM POWER OFF (REGARDLESS OF MODE) ③ Seasonal operation temperature of blowing/exhaust FAN and circulation pump on firewood mode. blowing and exhaust fan(3 steps) CIRCULATION PUMP Remark seasonal setting STOP 3rd STEP 45℃ 45℃ 30℃…
  • Page 28
    6. FUNCTIONS OF THE CONTROLLER 6-4 ROOM POWER OFF (REGARDLESS OF MODE) P/T stop when the oil inlet sensor is exhaust fan ON Oil inlet door LED disconnected. warning alarm flash promptly Automatic return normal when the firewood inlet Wood operation No Sign sensor is disconnected.
  • Page 29
    6. FUNCTIONS OF THE CONTROLLER 6-4 ROOM POWER OFF (REGARDLESS OF MODE) ③ Operation setting points of the Heating of Burner(IT,EP) and circulation pump on the firewood/oil combined mode (℃) CIRCULATION PUMP BURNER(FAN) SEASONAL FUNCTIONS REMARK (CTC-3500) 23℃ 20℃ 45℃(SUMMER) 22℃…
  • Page 30
    6. FUNCTIONS OF THE CONTROLLER 6-4 ROOM POWER OFF (REGARDLESS OF MODE) ⑤ Safety cutoff FUNCTIONS : P/T stopp and each safety device work NAME MEANS LED indication RETURN TIME RETURN Display number (CTR-6070) CONDITION 54℃ LED or low spark is not detected after the immediately after 2th P/T stop manual return…
  • Page 31: Room Control Panel

    7. FUNCTONS OF THE CONTROLLER 7-1 ROOM CONTROL PANEL 4. Initial cutoff functions : when CDS has been detecting the flame since initial combustion, do not ignite for the safety. 5. Resume functions (MAIN and, ROOM CONTROLLER) 5-1 when occur overheating, earthquake detector, safety cutoff, press the resume button. 5-2 P/T operation will stop during pushing the resume button.(When operating safety equipment) 6.

  • Page 32
    7. FUNCTONS OF THE CONTROLLER 7-1 ROOM CONTROL PANEL 11-2 when there is a leak of electricity in the External control line. — Operation : the boiler must be stopped unconditionally regardless of thermostat(CTR-6070) setting state. (When boiler power OFF,only freeze and burst function will operat) * If there is no room thermostat and you want to use an external control, the boiler will be operated by earthing the thermostat wires.
  • Page 33
    7. FUNCTONS OF THE CONTROLLER 7-1 ROOM CONTROL PANEL ◎ LEGEND 1. LED panel 2. BOILER HEATING OPERATING CONDITION SELECT BUTTON (RPPM TEMPERATURE HEATING, TIMER HEATING, OUT GOING) 3. DOMESTIC HOT WATER, ONLY 4. GREEN INDICATOR — POWER SUPPLY 5. ADJUSTMENT NUMERIC INCREASING/DECREASING BUTTON EACH FUNCTION 6.
  • Page 34
    7-2 ROOM CONTROL LED PANEL ◎ DISPLAY FUNCTIONS 1. When the boiler operates with room temperature heating mode, this symbol display 2. When the boiler operates with room temperature heating mode, this symbol display. 3. Current’s room temperature display in accordance with each heating modes. 4.
  • Page 35: Troubleshooting Guide (Error Code)

    8. TROUBLESHOOTING GUODE (ERROR CODE) 8-1 FINDING FAULT ※ If any abnormality is found during the operation of the boiler, do not take any measures to repair them at your own discretion; instead, refer to the below-stated issues. If any abnormality is generated in the boiler, the figures flash on the display part of the room thermometer depending upon the state.

  • Page 36
    8. TROUBLESHOOTING GUODE (ERROR CODE) 8-1 FINDING FAULT code Troubleshooting — Ignition is not done or ignition is done but has immediately shutdown due to a disorder in «01,” “02,” or flame detection. This may not be the trouble of the boiler and may be temporarily due to an “03”…
  • Page 37: Technical Data Table

    9. Technical Data Hybrid Boiler Technical Data Table KRH — 35A Model Technical Specification 23.2(20,000) Heating Output (Min) kW (kcal/h) 40.6(35,000) Wood Heating Output (Max) kW (kcal/h) 34.9(30,000) Domestic Hot Water Output kW (kcal/h) 29.0(25,000) Heating Output kW (kcal/h) 29.0(25,000) Domestic Hot Water Output kW (kcal/h) burner…

  • Page 38: Memo

    10. Memo 38페이지…

  • Page 39: Warranty

    11. Warranty 39페이지…

KSG Hifin — Руководство по эксплуатации 7.5 MB СКАЧАТЬ

TGB Hifin — Руководство по эксплуатации 2.6 MB СКАЧАТЬ

World Alpha C — Руководство по эксплуатации 5.1 MB СКАЧАТЬ

World Alpha S — Руководство по эксплуатации 5.2 MB СКАЧАТЬ

World Alpha New — Руководство по эксплуатации 3.4 MB СКАЧАТЬ

World Alpha — Руководство по эксплуатации 5.4 MB СКАЧАТЬ

Twin Alpha — Руководство по эксплуатации 3.9 MB СКАЧАТЬ

Turbo — Руководство по эксплуатации 3.9 MB СКАЧАТЬ

Turbo HI FIN — Руководство по эксплуатации 3.9 MB СКАЧАТЬ

STSO — Руководство по эксплуатации 4 MB СКАЧАТЬ

STSG — Руководство по эксплуатации 3.4 MB СКАЧАТЬ

KSO — Руководство по эксплуатации 4.8 MB СКАЧАТЬ

KSG — Руководство по эксплуатации 5.3 MB СКАЧАТЬ

KRР — Руководство по эксплуатации 4 MB СКАЧАТЬ

KRM — Руководство по эксплуатации 6.6 MB СКАЧАТЬ

KRH — Руководство по эксплуатации 3.5 MB СКАЧАТЬ

KF — Руководство по эксплуатации 3.3 MB СКАЧАТЬ

Котел KITURAMI World Alpha-35 — инструкция пользователя по применению, эксплуатации и установке на русском языке. Мы надеемся, она поможет вам решить возникшие у вас вопросы при эксплуатации техники.

Вы можете скачать инструкцию к KITURAMI World Alpha-35 по ссылке ниже, если не хотите ждать загрузки. Если остались вопросы, задайте их в комментариях после инструкции.

«Загружаем инструкцию», означает, что нужно подождать пока файл загрузится и можно будет его читать онлайн. Некоторые инструкции очень большие и время их появления зависит от вашей скорости интернета.

background image

КОТEЛ ГАЗОВЫЙ НАCТЕННЫЙ

С ДАТЧИКОМ УТЕЧКИ ГАЗА

WORLD ALPHA

13 15 18 24 30 35 

 Руководство по эксплуатации

 Паспорт котла

 Руководство по монтажу и
 техническому обслуживанию

8 800 707 25 02

ЗВОНОК ПО РОССИИ БЕСПЛАТНЫЙ

kituramirus.com

MADE IN KOREA

Полезные видео

Характеристики

Остались вопросы?

Не нашли свой ответ в руководстве или возникли другие проблемы? Задайте свой вопрос в форме ниже с подробным описанием вашей ситуации, чтобы другие люди и специалисты смогли дать на него ответ. Если вы знаете как решить проблему другого человека, пожалуйста, подскажите ему :)

Часто задаваемые вопросы

Как посмотреть инструкцию к KITURAMI World Alpha-35?

Необходимо подождать полной загрузки инструкции в сером окне на данной странице или скачать кликнув по специальной кнопке.

Руководство на русском языке?

Все наши руководства представлены на русском языке или схематично, поэтому вы без труда сможете разобраться с вашей моделью

Как можно распечатать инструкцию?

Скачайте ее по специальной кнопке над формой чтения на ваше устройства и отправьте на печать.

Понравилась статья? Поделить с друзьями:
  • Газовый котел hubert инструкция по эксплуатации
  • Газовый котел hubert инструкция по эксплуатации
  • Газовый котел ferroli vitabel f24 инструкция
  • Газовый котел ferroli vitabel f24 инструкция
  • Газовый котел dynasty sl tl24 инструкция