Smart-G SSB10 Operation Manual

  1. Manuals
  2. Brands
  3. Smart-G Manuals
  4. Boiler
  5. SSB10
  6. Operation manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Operation Manual

SSB10 SSB13 SSB16 SSB20 SSB25 SSB30 SSB35 SSB40

SAMSUNG BOILER CO., LTD.

http://www.smart-g.net

1

loading

Summary of Contents for Smart-G SSB10

  • Page 1
    Operation Manual SSB10 SSB13 SSB16 SSB20 SSB25 SSB30 SSB35 SSB40 SAMSUNG BOILER CO., LTD. http://www.smart-g.net…
  • Page 2
    List ◆Thank you for purchasing the Smart-g Boiler Safety instructions • ㆍ Caution before use ㆍ Caution in use ㆍ Identification of components How to use • ㆍ Remote controller ㆍ Operation procedure ㆍ Heating ㆍ going out(Heating) ㆍ Heating Interval(Heating) ㆍ…
  • Page 3
    Safety instructions ■This is to prevent potential dangers or accidents by using product safety and properly. Please keep this in mind Danger If you ignore this mark and misuse, it could cause death or serious injury. Warning If you disregard this mark, a user might get a serious injury. Caution If you neglect this mark, a user can get harm or physical damage.
  • Page 4
    Caution before use Warning ■Check your supply gas. ■Do not keep inflammables close. ㆍDo not keep any inflammables such as ㆍThe type of gas is stated on the side of spray, gasoline and benzene around product. If you use different kind of gas, it product.
  • Page 5
    Caution in use Warning ■If malfunctioning or gas leakage is ■Do not separate connector of exhaust detected..pipe. ㆍStop operating, and contact installer or ㆍIf exhaust gas indraft into indoor, it will call for our service center. happen to gas poisoning. Must do Must do ■Do not dismantle, repair or modify except…
  • Page 6
    Identification of components Exhaust Pipe Pressure Gauge Gas Inlet Water Filling Valve Heating Outlet Heating Return Hot Water Outlet Cold Water Inlet…
  • Page 7
    Block Diagram ⑮ ① ② ③ ⑭ ⑬ ④ ⑫ ⑤ ⑪ ⑥ ⑦ ⑩ ⑧ ⑨ ① Expansion Tank ⑨ Flow detector ② Hot water flow Switch ⑩ Circulation Pump ③ Ignition Plug ⑪ Safety valve (Hose) ④ Aps Switch ⑫…
  • Page 8
    How to use Remote controller Freeze Protection On/Off Heating Temperature Bath On Heating On/Off Hot water Temperature Current Temperature Going Out Checkup Heating Interval Check Lamp Combustion Lamp Bath Only Heating+Bath Button Temperature Up Heating Interval Temperature Button Setting Going Out Setting Power Button Temperature Down Components…
  • Page 9
    Operation Procedures Heating ▶ How to Set Heating Temperature Press Heating+Hot Water button for 3 seconds. When ‘Heating Temperature’ display flickers, heating Heating+ Hot Water temperature by pressing the button flickers when the Up or Down button. (Press boiler starts working. Heating+Hot Water button Combustion lamp is on again or wait for 5 seconds,…
  • Page 10
    Going out (Heating) Press Going Out button. When Going Out button is on, Turn Heating Operation for Going Out starts. on by pressing Heating button. For <Room Heating> For <Floor Heating> ▶What is Operation for Going Out? Warm the rooms by operating the boiler at the minimum level when no one is at home. To cancel Operation for Going Out, press the Going Out button again or Heating button.
  • Page 11
    Bath Even when the Bath button on the remote controller is on, the boiler doesn’t work to supply hot water if hot water is not used. Press the Bath button for 3 seconds. When ‘Temperature’ Turn the Bath display flickers, set the hot water temperature by pressing the Up or function on by Down buttons.
  • Page 12
    Cleaning and maintenance Warning ■Check if there is deformation on ■Do not clean using water soaked product or deformation over ventilating cloth shaft. And check if ventilating shaft is come off •Electroshock or from product.. breakdown could •If exhaust gas leaks, happen.
  • Page 13
    Measures when safety device is on When the boiler doesn’t work and the Failure code on the LCD panel of the remote controller flickers, check the following and take the proper action. Failures Failure Codes Symptoms and Causes Hot Water Temperature Sensor Disconnection or short circuit of hot water temperature Failure sensor…
  • Page 14
    Specifications Forced balanced flue , sealed combustion chamber Model SSB10 SSB13 SSB16 SSB20 SSB25 SSB30 SSB35 SSB40 Content Forced balanced flue , sealed combustion chamber ㎡ Heated Area 30~70 60~90 60~130 90~170 90~210 110~310 130~370 150~450 Model 11.6 15.1 18.6…
  • Page 15
    Before ask for service Trouble Checking point Trouble shooting condition (1) Do not light match and lighter & Do not turn on the light. (2) Stop using boiler immediately Close gas intermediate valve, and contact with a special gas supply installer. (3) Check regularly if there is a gas leakage by pasting spraying a soapy water.
  • Page 16
    Instruction of installation Caution for installation To person who installs. Caution ㆍInstallation must be done by authorized professionals. If not, you will be punished by the relative law. ㆍRead this manual carefully before installing. (When installation is not consistent with this manual, we are not responsible any damages) ㆍIf air supply or exhaust gas pipe is not correctly connected, user can suffer from gas poisoning due to gas leakage.
  • Page 17
    Instruction of installation Caution for installation Location Warning ■Please, Install the boiler in the exclusive place. (Forced Exhaust type FE) ㆍThe exclusive place where is keep with air supply and exhaust should be install. Forced draught balanced flue type (FF type) should be install exclusive place only except following case①…
  • Page 18
    Installation…
  • Page 19
    Pipework Pipe Connection ① Heating water Outlet ② Heating water Return ③ Hot water Outlet ④ Gas Inlet ⑤ Cold water Inlet Install butterfly valve for each valve Open the every distribution point such as Water Pipe, Gas Pipe etc to protect freezing in cold weather during away from home for long period Do not cut off Gas and Electricity…
  • Page 20
    Pipe Construction Electric wiring For this product, AC220V power source is necessary Electric wiring Caution for electric wiring work, inquire a professional electrical company must be grounded ㆍ Grounding ㆍIt should be install grounding work to prevent from an electric shock and short circuit by leakage an electric current boiler ㆍConnecting grounding wire with metal piece and bury it in humid underground.
  • Page 21
    Antifreezing of pipe Caution ㆍKeep a warm a Insulating material with thickness 25mm over. (Cold area 50mm over). ㆍEspecially, the surface of hot water heating pipe have to installed heat wire to prevent from severe cold winter. (Heat wire must be purchase, only) ㆍDo not wrap the drain knob and filter with insulating material.
  • Page 22
    Room Heating Piping construction Connect with pipe diameter of 20A (PT3/4”) . It should be buried pipe but it must not be connected at buried place It is difficult maintenance when there is a leakage . It should be used same size of diameter for inlet pipe and return pipe. .
  • Page 23
    Air Supply/Exhaust Tube Installation ■Diameter of air supply/exhaust tube Outer Diameter Through Wall Tube Size (mm) of Tube Size (mm) 60(75) Over 100 Warning! Use only the tube that satisfies the specifications. If the diameter of tube doesn’t fit, exhaust gas can leak and cause carbon monoxide Caution poisoning.
  • Page 24
    Air supply / exhaust pipe installation (Unit : mm) ㆍRestricted to the distance from top of exhaust to the window Warning Must be followed ■Exhaust pipe installed tilt about 3 down direction to outside for the prevent of back flow. ■At the end of the exhaust pipe, install an insect net to prevent a ball from entering.(a ball of diameter 16mm) ■There is no obstacle from end of Exhaust pipe to…
  • Page 25
    How to Install Remote Controller Site Requirements  Mount the remote controller on the wall without any obstacles at a height of 1.2 to 1.5m from the floor for simple control on the room temperature or hot water in a room or a living room. …
  • Page 26
    How to Install Remote Controller  Install the remote controller wire where it will not be directly influenced by heat. Mounting Remote Controller  Wall Mounting Drill the hole for the plug on the wall (6.0 x 35~40mm deep). Insert the plug. The hole must be drilled at a right angle.
  • Page 27
    Test running When filling water, the LCD panel on the remote controller displays Heating and Bath. Do not control the buttons on the remote controller at that moment. When filling water during the test run, turn the Heating and Bath buttons off (initial setting of the product), unplug the power.
  • Page 28
    Item Procedure Remarks ① Connect the drain hole on the Drain Pipe Installation (Check) If the drain hose is not connected bottom left of the boiler to the to the drain pipe, water from the drain pipe using the flexible hose. ②…
  • Page 29
    Wiring & Parameter setting 10K/13K/16K 30K/35K/40K…
  • Page 30
    SPARE PARTS LIST Parts List No. Description Unit Q’tity Model Photograph SSB-10K, 13K, SSB1025ML0001A Expanion Tank 16K, 20K, 25K SSB-30K, 35K, SSB3040ML0001A Expanion Tank Heating SSB-10K-40K Temperature Sensor SSB1040ML0001A DHW Temperature SSB-10K-40K Sensor SSB1040ML0002A Main Controller SSB-10K-40K SSB1040ML0003A Circulation Pump SSB-10K-40K SSB-10K, 13K, SSB1040ML0004A…
  • Page 31
    SSB-30K, 35K, SSB3040ML0002A Gas Valve Set, 20A Main Heat SSB-10K, 13K, SSB1025ML0003A Exchanger 16K, 20K, 25K Main Heat SSB-30K, 35K, SSB3040ML0003A Exchanger SSB-10K, 13K, 2nd Heat SSB1040ML0005A 16K, 20K, 25K, Exchanger/DHW 30K, 35K, 40K SSB-10K, 13K, SSB1040ML0006A Burner 16K, 20K, 25K, 30K, 35K, 40K SSB1040ML0009A Three Path Motor…
  • Page 32
    SSB1040ML0013A Air Pressure Switch SSB-10K-40K Ignition SSB1040ML0014A SSB-10K-40K Components SSB1040ML0015A 95℃ Thermostat SSB-10K-40K SSB1040ML0019A Room Controller SSB-10K-40K SSB1040ML0036A Flow Detector SSB-10K-40K SSB-10K, 13K, Nozzle holder SSB1040ML0037A 16K, 20K, 25K, (LPG) 30K, 35K, 40K…
  • Page 33
    Indemnity Damages Compensation Standards Remarks Performance or functional Replacement or refund Calculation expenses defects occurred under the replacement refund: normal operation status and Installation expenses required requiring maintenance service for re-installation included. within 10 days after purchase Performance or functional Repair without defects occurred under the…
  • Page 34
    Warranty Model Date of Purchase Vendor Manufacturing No. Name Warranty Period Vendor Address Date of Repair Description Engineer Confirm This Product successfully passed the strict quality management and close inspection. We guarantee repair, replacement or refund for any reasonable customers’ damages in accordance with the Consumer Damage Compensation Regulations published by the Ministry of Finance and Economy.
  • Page 35
    Address : 75, Seokmun-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Korea Tel : +82-41-583-7200, 7211, 7213 FAX : +82-41-583-7500 Home Page : http://www.smart-g.net…

■This is to prevent potential dangers or accidents by using product safety and properly.

Please keep this in mind

Danger

Warning

Caution

※Injury : No hospitalization needed. Treatment, for example scratch, burning(high temp., low temp.),

electric shock etc.

※Physical damage : Extended damage to house, household belongings, domestic animals, beddings.

General Danger,

Warning, Caution

Caution:Inflammable

Gas Leakage

ㆍWhenever gas leakage detected, do not panic and follow our instruction as below.

① Close intermediate valve.

② Open the door or window for ventilation.

Danger

Call for gas supplier or our service center.

※Flame or spark is likely to cause explosion.

These are dangerous situations and don t put yourself

in the same situation.

Do not light a fire

or unplug a power cord.

Caution:Inflammable

ㆍCheck if gas leakage is detected.

Must do

Safety instructions

.

If you ignore this mark and misuse, it could cause death or serious injury.

If you disregard this mark, a user might get a serious injury.

If you neglect this mark, a user can get harm or physical damage.

Do not turn on any electric

appliances including a ventilation fan

Prohibitive

Frequently check using liquid soap around gas pipe

connector if gas is leaked.

Do not touch

Must do

Close the

intermediate valve

3

Prohibitive

Electric wiring

must be grounded

Open the

window or door.

Do not make a call

Prohibitive

Описание

Газовый настенный котел от всемирно известного бренда Samsung. Отличное соотношение цена-качество.

3 года гарантии.

Характеристики

Габаритные и присоединительные размеры
Высота 660 мм
Ширина 490 мм
Выход контура ГВС 1/2″
Подключение газа 3/4″
Вход в систему отопления 3/4″
Возврат из системы отопления 3/4″
Вход контура ГВС 1/2″
Глубина 350 мм
Диаметр дымохода 75 мм
Основные
Состояние Новое
Тип топки

Закрытая
Расход газового топлива 5.33 куб. м/час
Мощность номинальная

46 кВт
Назначение котла

Двухконтурный
Коэффициент полезного действия

92.5 %
Вид топлива Газообразное
Количество теплообменников 2 шт.
Способ установки Настенный
Гарантийный срок

36 мес
Теплоноситель Вода
Материал теплообменника

Медь
Страна производитель Южная Корея
Вес 35 кг
Способ отвода отработанных газов

Турбо
Производитель

Samsung
Электрические параметры
Частота

50 Гц
Напряжение сети

220~240 В
Потребляемая мощность

140 Вт
Горячее водоснабжение
Максимальная температура в режиме ГВС 60 град.
Производительность горячей воды 22.2 л/мин

Информация для заказа

  • Цена: 336 000 

Газовый двухконтурный котел  SMART-G SSB29K от компании SAMSUNG рассчитан на обогрев помещений площадью до 200 кв. м, а также на снабжение потребителей горячей водой для бытовых нужд. Благодаря инновационным технологиям  SAMSUNG, а также использованным в конструкции котла циркуляционным насосам GRUNDFOSS (Германия), котлы SMART-G  надежно и экономно обеспечивают теплом и горячей водой.

 

 
 
 
 
 

Наименование Ед. изм SSB11k SSB15k SSB18k SSB23k
Отапливаемая площадь М² 30-90 60-110 60-160 90-200
Максимальная мощность в режиме отопления кВт (ккал/ч) 11,6 кВт (10000 ккал/ч) 15,1 кВт (13000 ккал/ч) 18,6 кВт (16000 ккал/час) 23,0 кВт (20000 ккал/ч)
Тепловая мощность нагрева горячей воды кВт (ккал/ч) 15,1 кВт (13000 ккал/ч) 18,6 кВт (16000 ккал/час) 18,6 кВт (16000 ккал/час) 23,0 кВт (20000 ккал/ч)
Применение Отопление и нагрев воды
Тип газа СПГ, СНГ
Расход газа, max СПГ м³/ч 1.33 (1.87) 1.87 (2.24) 2,24 2,78
Расход газа, max СНГ кг/ч 0,96 1,36 1,63 2,02
Максимальный КПД % 92
Уровень шума дБ < 43
Производительность ГВС, t⁰C 30 л/м 7,2 8,8 8,8 11,1
Давление газа , min мм Н2О (мбар) 105 (1,05)
Давление газа , max мм Н2О (мбар) 110 (1,1) 110 (1,1) 110 (1,1) 115 (1,15)
Электропитание В/Гц 220/50~60
Максимальное давление воды на входе мм 3,0
Максимальная температура теплоносителя ⁰С 35-80
Размеры (ШхГхВ) мм 490*230*660
Вес кг 30,7 31,8 31,8 32,5
Диаметр соединений, вход/выход отопления мм 20
Диаметр соединений, вход/выход ГВС мм 15
Диаметр соединений, подача газа мм 15
Диаметр дымохода мм FunnelØ 60*100
Наименование Ед. изм. SSB29k SSB35k SSB41k SSB46k
Отапливаемая площадь М² 90-240 110-350 130-400 150-470
Максимальная мощность в режиме отопления кВт (ккал/ч) 29 кВт (25000 ккал/ч) 35 кВт (30000 ккал/ч) 41 кВт (35000 ккал/час) 46 кВт (40000 ккал/ч)
Тепловая мощность нагрева горячей воды кВт (ккал/ч) 29 кВт (25000 ккал/ч) 35 кВт (30000 ккал/час) 41 кВт (35000 ккал/час) 46 кВт (40000 ккал/ч)
Применение Отопление и нагрев воды
Тип газа СПГ, СНГ
Расход газа, max, СПГ м³/ч 3,33 3,91 4,48 5,33
Расход газа, max, СНГ кг/ч 2,42 2,83 3,25 3,86
Максимальный КПД % 92
Уровень шума дБ < 43
Производительность, ГВС, t⁰C 30 л/м 13,8 16,7 19,4 22,2
Давление газа, min мм Н2О, (мбар) 105 (1,05)
Давление газа, max мм Н2О, (мбар) 110 (1,1) 115 (1,15)
Электропитание В/Гц 220/50~60
Максимальное давление воды на входе мм 3,0
Максимальная температура при установке ⁰С 35-80
Размеры (ШхГхВ) мм 490*230*660 490*350*660
Вес кг 32,5 34,9 35,4
Диаметр соединений, вход/выход ГВС мм 15 15
Диаметр соединений, подача газа мм 15 20
Диаметр дымохода мм FunnelØ 60*100 FunnelØ 75*100


0%

Настенный газовый котел Samsung SMART SSB 35

Артикул: 21502

Мощность: 41 кВт.
Габариты: 490x350x660 мм.
Вес: 34.9 кг.

Официальный дилер

Официальный дилер
(нам 14 лет)

Официальная гарантия

Официальная гарантия

Рейтинг 5 звезд от Яндекс.Маркет

Рейтинг 5 звезд
от Яндекс.Маркет

Быстрая доставка (0-1 день)

Быстрая доставка
(0-1 день)

Описание

Котел отопления Samsung SMART SSB 35

Газовый двухконтурный котел SAMSUNG серии SMART, используется как надежное и эффективное решение для обогрева жилых домов и производственных помещений. Отопительные приборы отличаются эффективностью до 98%, широким функционалом и вместе с тем просты в эксплуатации.

Технические характеристики

Площадь отопления 130-370 м2
Мощность отопления/ГВС 41 кВт
Уровень шума < 43 Дб
ГВС при t=30 ℃ 19.4 л/мин.
Источник питания 220 Вт.
Мин. растопочное давление < 250 Па
Рабочее давление системы отопления 0,5-3,0 кПа
Температура нагрева воды в системе отопления 40 — 80 ℃
Температура нагрева воды в системе ГВС 30 — 60 ℃
Габариты (Д/Ш/В) 490x350x660 мм.
Вес 34,9 кг
Соединительные размеры ОВ 20 мм.
Соединительные размеры ГВС 15 мм.
Соединительные размеры газ 20 мм.
Размер трубы дымохода (Диаметр x Длина) 75×100 мм.

Особенности — преимущества

  • Высокая эффективность и экономичность.
  • Уникальная технология сгорания газа и теплообмена.
  • Возможность работы на сжиженном и природном газе.
  • Контур приготовления горячей воды.
  • Низкий уровень шума даже при высоких нагрузках.
  • Превосходное качество сборки и комплектующих.
  • Соответствие самым жестким стандартам безопасности.
  • Простота в эксплуатации и сервисном обслуживании.
  • Контроль температуры и уровня воды.
  • Эффективная система диагностики состояния.
  • Система контроля и автоматического отключения газа.

Информация на сайте не является публичной офертой.
Внешний вид и комплектация может быть изменена производителем без предварительного уведомления.

Настенный газовый котел Samsung SMART SSB 35

Наличный и безналичный расчет, банковские карты

Отзывы

Хотите оставить отзыв?Поставьте свою оценку!

Сделайте выбор!

Понравилась статья? Поделить с друзьями:
  • Газовый котел rocterm инструкция по эксплуатации
  • Газовый котел rocterm инструкция по эксплуатации
  • Газовый котел rocterm td b20 инструкция
  • Газовый котел rocterm td b20 инструкция
  • Газовый котел protherm рысь 23 bove инструкция