XANTUS (PRO) HM 24 — HM 28 ROOM SEALED CONVENTIONAL COMBI BOILER COMBI INSTALLATION AND USER’S MANUAL Read carefully before operat ng the appl ance…
Page 3
INDEX 1.INTRODUCTION 2. WARNINGS FOR THE USER 3. CONDITIONS INELIGIBLE FOR WARRANTY 4. SWITCHING ON THE BOILER 5. DAILY OPERATION OF THE BOILER 6. FILLING THE BOILER 7. SWITCHING OFF THE BOILER 8. MAINTENANCE OF THE BOILER 9. INSTALLATION INSTRUCTIONS 10.
Page 4: Warnings For The User
Thermex authorised service 3. CONDITIONS INELIGIBLE FOR WARRANTY The THERMEX warranty claim does not apply any failures arising from any use of the appliance out of such men oned in this manual as well as from the following cases: a.
Page 5: Switching On The Boiler
c. Arising from selec ng a wrong loca on for the appliance, d. Arising from selec ng wrong type of appliance for the intended purpose, e. Arising from intervening the appliance by an unauthorized service agency, f. Physical failures happened a er the appliance has been delivered, g.
Page 6: Filling The Boiler
5. DAILY OPERATION OF THE BOILER Summer/Winter mode selec on; When it is not required to use Central Hea ng mode of the boiler, the appliance may be turned to Summer mode sole to produce Domes c Hot Water. In order to set Summer mode turn “on/off” bu on to ( ) posi on.
Page 7
Figure 2 Figure 3 To switch off the boiler turn ON/OFF bu on ( ) to “Off” posi on. When the boiler is switched off through this bu on the pump an blockage func on is ac ve, an -frost protec on is not ac ve and there is electric current in the boiler.
Page 8
In order to use your appliance trouble-free and efficiently for long years we recommend scheduling annual maintenance, preferably at early winter season, by Thermex authorised service. Do not clean external surfaces of your appliance with detergent or chemical materials. Check your installa on before making connec ons to the boiler and ensure that the installa on pipes are free from dirt or any par cles.
Page 9
Figure 5…
Page 10: Flue Connection
Figure 6 11. FLUE CONNECTION When connec ng the flue, the flue gas accessories supplied by the manufactured must be used. When selec ng the loca on of the boiler the posi on of flue gas connec on and flue terminal should be considered.
Page 11
e. Where the appliance is installed to penthouses flue terminal should be minimum 40 cm above the roof. In such cases the roof must be insulated with non-combus ble material. f. Maximum length of the flue connec on is 5 m. Maximum length is shortened by 1 meter for each addi onal 90°…
Page 12: Electric Connection
WARNING: Fan baffle plates included in the package should be used with the connec ons for horizontal and ver cal flue extensions. Figure 11. Figure 11 XANTUS (PRO) HM 24 XANTUS (PRO) HM 28 12. ELECTRIC CONNECTION The appliance must be connected to a power supply line with an efficient earth connec on. The appliance must be connected to 220 ~ 230 V single phase power supply line with efficient earth connec on through 2A.
Page 13: Error Codes
To use a room thermostat capable of controlling all func ons of the boiler including domes c hot water produc on, contact with your authorised service agency. Such room thermostats may provide internet connec on and remote access may be made. If required, you may control the appliance through a computer or smart phones and tablets that provide required features.
Page 14
Figure 14…
Page 15
XANTUS (PRO) 24 HM…
Page 16
XANTUS (PRO) 28 HM…
Page 18
Dear Customer, Thank you for choosing a Thermex product. www.thermex.com.tr 0850 775 05 15…