Service manual Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR Climatic Control Corporation Wall-Mounted Split Type Content 1. Precaution 1 1.1 1.2 Safety Precaution Warning1 1 2. Function 3 3. Dimension 5 3.1 3.2 Indoor unit 5 Outdoor unit 6 4. Specification 7 5. Refrigerant cycle diagram 9 6. Operation limits 10 6.1 6.2 Cooling operation Heating operation 10 10 7. Schematic diagram and Wiring diagram 7.1 7.2 11 Schematic diagram 11 Wiring diagram 12 8. Installation details 15 8.1 8.2 8.3 8.4 8.5 8.6 8.7 8.8 8.9 Wrench torque sheet for installation 15 Connecting the cables 15 Pipe length and the elevation 15 Air purging of the piping and indoor unit 16 Pumping down (Re-installation) 17 Re-air purging (Re-installation) 18 Balance refrigerant of the 2-way, 3-way valves 19 Evacuation 20 Gas charging 21 9. Capacity table 22 9.1 9.2 9.3 9.4 9.5 10. 10.1 10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 GC/GU-S05CR GC/GU-S07HR GC/GU-S09HR GC/GU-S12HR GC/GU-S18HR 22 22 23 23 24 Electronic function 25 Electronic control working environment 25 Proper symbols and their meaning 25 Function 25 Protection 26 Fan-only mode 26 Cooling mode 26 Dehumidifying mode 27 Heating mode 28 Defrosting mode(available for heating mode) 29 www.generalclimate.com Wall-Mounted Split Type 10.10 Auto mode 30 10.11 Force cooling function 30 10.12 Sleep mode 31 10.13 Auto restart function 31 10.14 Anion (optional) 31 11.Model and Parameters 33 12. Troubleshooting 34 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.9 13. Display board 34 Troubleshooting 34 Diagnostic chart 35 Resetting phenomenon often occurs during operation. 36 Operation lamp flashes and Timer lamp off. 36 Operation lamp flashes and Timer lamp on. 36 Operation lamp off and Timer lamp flashes 37 Operation lamp on and Timer lamp flashes 37 Operation lamp flashes, Timer lamp flashes . 37 Characteristic of temperature sensor www.generalclimate.com 38 Wall-Mounted Split Type 1. Precaution 1.1 Safety Precaution n To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instruction will cause harm or damage. n Before service unit, be sure to read this service manual at first. 1.2 Warning Ø Installation n Do not use a defective or underrated circuit breaker. Use There is risk of fire or electric shock. n For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized service center. Do not disassemble or repair the product, there is risk of fire or electric shock. n Always ground the product. There is risk of fire or electric shock. n Install the panel and the cover of control box securely. open. Moisture may condense and wet or damage furniture. n Take care to ensure that power cable could not be pulled out or damaged during operation. There is risk of fire or electric shock. n Do not place anything on the power cable. There is risk of fire or electric shock. n Do not plug or unplug the power supply plug during There is risk of fire of electric shock. n Always install a dedicated circuit and breaker. operation. Improper wiring or installation may cause fore or electric shock. n Use the correctly rated breaker of fuse. There is risk of fire or electric shock. n Do not modify or extend the power cable. There is risk of fire or electric shock. n Do not install, remove, or reinstall the unit by yourself (customer). There is risk of fire, electric shock, explosion, or injury. n Be caution when unpacking and installing the product. Sharp edges could cause injury, be especially careful of the case edges and the fins on the condenser and evaporator. n For installation, always contact the dealer or an Authorized service center. There is risk of fire, electric shock, explosion, or injury. n Do not install the product on a defective installation stand. It may cause injury, accident, or damage to the product. n Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury. www.generalclimate.com n Do not let the air conditioner run for a long time when the humidity is very high and a door or a windows is left this appliance on a dedicated circuit. 1 There is risk of fire or electric shock. n Do not touch (operation) the product with wet hands. There is risk of fire or electric shock. n Do not place a heater or other appliance near the power cable. There is risk of fire and electric shock. n Do not allow water to run into electric parts. It may cause fire, failure of the product, or electric shock. n Do not store or use flammable gas or combustible near the product. There is risk of fire or failure of product. n Do not use the product in a tightly closed space for a long time. Oxygen deficiency could occur. n When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. Do not use the telephone or turn switches on or off. There is risk of explosion or fire. n If strange sounds, or small or smoke comes from product. Turn the breaker off or disconnect the power supply cable. There is risk of electric shock or fire. n Stop operation and close the window in storm or hurricane. If possible, remove the product from the window before the hurricane arrives. Wall-Mounted Split Type There is risk of property damage, failure of product, or electric shock. n Do not open the inlet grill of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure. n When the product is soaked (flooded or submerged), contact an Authorized service center. n Do not expose the skin directly to cool air for long periods of time. (Do not sit in the draft). This could harm to your health. n Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigerant system. There is risk of damage or loss of property. n Do not block the inlet or outlet of air flow. There is risk of fire or electric shock. n Be caution that water could not enter the product. There is risk of fire, electric shock, or product damage. n Ventilate the product from time to time when operating it together with a stove, etc. There is risk of fire or electric shock. n Turn the main power off when cleaning or maintaining the product. There is risk of electric shock. n When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. There is risk of product damage or failure, or unintended operation. n Take care to ensure that nobody could step on or fall onto the outdoor unit. This could result in personal injury and product damage. It may cause product failure. n Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. There is risk of fire, electric shock, or damage to the plastic parts of the product. n Do not touch the metal parts of the product when removing the air filter. They are very sharp. There is risk of personal injury. n Do not step on pr put anything on the product. (outdoor units) There is risk of personal injury and failure of product. n Always insert the filter securely. Clean the filter every two weeks or more often if necessary. A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. n Do not insert hands or other object through air inlet or outlet while the product is operated. Ø CAUTION n Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product. n Install the drain hose to ensure that water is drained away properly. There are sharp and moving parts that could cause personal injury. n Do not drink the water drained from the product. It is not sanitary could cause serious health issues. n Use a firm stool or ladder when cleaning or maintaining the product. A bad connection may cause water leakage. n Keep level even when installing the product. Be careful and avoid personal injury. n Replace the all batteries in the remote control with new To avoid vibration of water leakage. n Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. It may cause a problem for your neighbors. n Use two or more people to lift and transport the product. Avoid personal injury. n Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation. www.generalclimate.com Ø Operational 2 ones of the same type. Do not mix old and mew batteries or different types of batteries. There is risk of fire or explosion. n Do not recharge or disassemble the batteries. Do not dispose of batteries in a fire. They may burn of explode. n If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the remote of the batteries have leaked. The chemical in batteries could cause burns or other health hazards. Wall-Mounted Split Type 2. Function Indoor unit Operation ON/OFF by remote controller Sensing by room temperature Room temperature sensor. Pipe temperature sensor. Room temperature control Maintain the room temperature in accordance with the setting temperature. Starting temperature control Indoor fan is delayed for 5 sec at the starting. Time Delay Safety control Restarting is for approx. 3 minutes.. Indoor fan speed control High, med, low, breeze. Operation indication Lamps (LED) Light up in the LED (LCD) for each operation mode. Two-direction air vane Anti-cold function The unit will decide the louver direction according to operation mode. Sleep mode auto control The fan is turn to low speed (cooling/heating). The unit will be turn off after seven hours. Independent dehumidification Prevent the cold wind at the beginning of unit start. Temp. Compensation Defrost mode The function is usually used in rainy days in springtime or damp areas. Auto-restart function Self-diag. function The function will be operate in any operation mode. Flexible wiring connection Air flow Direction control Easy clean panel The louver can be set at the desired position or swing up and down automatically Auto mode The unit can be change by the room temperature. www.generalclimate.com 3 Wall-Mounted Split Type Outdoor unit Power relay control The unit has 3 mins delay between continuously ON/OFF operations. Low ambient kit The unit can operate in cooling mode at low ambient temperature conditions. Low noise air flow system Bird tail propeller fan makes the outdoor unit run more quietly. Hydrophilic aluminum fin The hydrophilic fin can improve the heating efficiency at operation mode. 4 way valve control It is only operated in the heating operation mode except defrosting operation. Discharge pipe temperature protect Anti-rust cabinet Made from electrolytic zinc steel sheet and anti-rust coated components. Valve protection cover It protects the valves and prevents water from dripping. www.generalclimate.com 4 Wall-Mounted Split Type 3. Dimension 3.1 Indoor unit Dimension Mode 5K 7K 9K 12K 18K www.generalclimate.com W H L 750 750 750 750 906 250 250 250 250 286 188 188 188 188 235 5 Wall-Mounted Split Type 3.2 Outdoor unit Dimension Mode 5K 7K 9K 12K 18K www.generalclimate.com W H D L1 L2 L3 700 700 700 780 760 535 535 535 540 590 235 235 235 250 285 458 458 458 530 540 280 280 280 315 335 540 540 540 590 615 6 Wall-Mounted Split Type 4. Specification Model Power supply Cooling Heating Capacity Input Rated current EER Capacity Input Rated current COP Max. current Starting current Model Type Brand Capacity Input Compressor Rated current(RLA) Locked rotor Amp(LRA) Thermal protector Capacitor Refrigerant oil Model Brand Indoor Input fan motor Capacitor Speed(hi/mi/lo) Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo) Model Brand Outdoor Input fan motor Capacitor Speed Outdoor air flow Outdoor noise level Refrigerant type R22 Design pressure Liquid side/ Gas side Refrigerant Max. refrigerant pipe length piping Max. difference in level Operation temp Ambient temp Application area Ph-V-Hz Btu/h W A Btu/w.h Btu/h W A W/W A A Btu/h W A A uF ml W uF r/min m3/h dB(A) W uF r/min 3 m /h dB(A) g MPa mm m m ℃ ℃ 2 m GC/GU-S05CR 1, 220-240V~,50Hz 5000 560 2,6 9 ----------------3,8 16 KH104VFHC Rotary SHANGHAI SENLIN 5700 590 2,7 13 BF540-KB 15 MS-56 270 RPG13H WELLING 36,5 1.2μF/450V 1020/ 960/ 900 300/270/240 32/30/28 YDK24-6T WELLING 70 3 850 1400 49 480 2,6 6.35/ Ф Ф9.53 10 5 17-30 18-45 8-12 GC/GU-S07HR 1, 220-240V~,50Hz 7000 760 3,6 9,2 7600 760 3,4 10 5 18 2P14C235ANA Rotary GD Matsushita 7500 725 3,4 15 MRA98854 25 ATOMOS M60 270 RPG13H WELLING 36,5 1.2μF/450V 1020/ 960/ 900 380/350/320 32/30/28 YDK24-6T WELLING 70 3 850 1400 49 620 2,6 6.35/ Ф Ф9.53 10 5 17-30 -7 - 45 10-14 Note: The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement. www.generalclimate.com 7 Wall-Mounted Split Type Model Power supply Capacity Input Cooling Rated current EER Capacity Input Heating Rated current COP Max. current Starting current Model Type Brand Capacity Input Compressor Rated current(RLA) Locked rotor Amp(LRA) Thermal protector Capacitor Refrigerant oil Model Brand Indoor Input fan motor Capacitor Speed(hi/mi/lo) Indoor air flow (Hi/Mi/Lo) Indoor noise level (Hi/Mi/Lo) Model Brand Outdoor Input fan motor Capacitor Speed Outdoor air flow Outdoor noise level Refrigerant type R410A Design pressure Liquid side/ Gas side Refrigerant Max. refrigerant pipe length piping Max. difference in level Operation temp Ambient temp Application area GC/GU-S09HR GC/GU-S12HR GC/GU-S18HR Ph-V-Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz 1, 220-240V~,50Hz Btu/h 9000 12000 18000 W 960 1230 1920 A 4,5 5,7 9 Btu/w.h 9,4 9,8 9,4 Btu/h 10000 13000 20000 W 980 1290 1980 A 4,4 6 9,2 W/W 10,2 9,8 10,1 A 7 9,1 10 36 A 25 26 SHY33MC2-U 2P18S225ANK PH225X2C-4FT rotary Rotary Rotary Hitachi GD Matsushita GD Toshiba Btu/h 9920 13610 17620 W 970 1305 1725 A 4,5 6,1 8,1 A 24 26 36 External(MRA98745) External Internal 50 uF 30 35 600 ml SUNISO 350 430 RPG13H RPG25 RPG13H WELLING Welling WELLING 36,5 53 W 36,5 1.2μF/450V 1.5uF/450V uF 1,2 r/min 1100/1020/950 1350 1180 450/420/390 750/710/650 m3/h 550/500/460 37/34/31 41/38/35 dB(A) 41/ 38 /34 YDK24-6T YDK24-6 YDK25-6H WELLING WELLING WELLING 96 W 55 72 2.5μF/450V 2.5μF/450V 2.5μF/450V uF 900 r/min 800 850 3 1500 1800 2000 m /h dB(A) 50 52 54 1370 g 650 820 2,6 2,6 MPa 2,6 mm Ф6.35/Ф9.53 Ф6.35/Ф12.7 Ф6.35/Ф12.7 m 10 10 15 m 5 5 8 17-30 17-30 17-30 ℃ -7 - 45 -7 - 45 -7 - 45 ℃ 2 14-21 18-26 25-35 m Note: The noise date is base on hemi-anechoic chamber, during actual operation; these values are normally somewhat different as a result of ambient condition. The above design and specifications are subject to change without prior notice for product improvement. www.generalclimate.com 8 Wall-Mounted Split Type 5. Refrigerant cycle diagram Ø Cooling only Ø Heat pump mode www.generalclimate.com 9 Wall-Mounted Split Type 6. Operation limits 6.1 Cooling operation Outdoor unit air temp.℃ DB Indoor air temp. ℃ DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage. 6.2 Heating operation Indoor air temp. ℃ DB Outdoor unit air temp.℃ DB Note: The chart is the result from the continuous operation under constant air temperature conditions. However, excludes the initial pull-down stage. www.generalclimate.com 10 Wall-Mounted Split Type 7. Schematic diagram and Wiring diagram 7.1 Schematic diagram www.generalclimate.com 11 Wall-Mounted Split Type 7.2 Wiring diagram 7.2.1 Cooling mode GC/GU-S05CR I NDOOR UNI T OUTDOOR UNI T 1 2︵N︶ Y&G BLACK BLACK OVERLOAD RELAY RED RED BLACK COMPRESSOR C RED Y&G R S BLUE FAN RED MOTOR Y&G COMPRESSOR CAPACI TOR www.generalclimate.com BLUE FAN CAPACI TOR 12 Wall-Mounted Split Type 7.2.2 GC/GU-S07HR , GC/GU-S 09HR, GC/GU-S12HR www.generalclimate.com 13 Wall-Mounted Split Type MSG-18HR www.generalclimate.com 14 Wall-Mounted Split Type 8. Installation details 8.1 Wrench torque sheet for installation Outside diameter mm φ6.35 φ9.52 φ12.7 φ15.88 φ19.05 8.2 Torque Kg.m 1.8 4.2 5.5 6.6 6.6 inch 1/4 3/8 1/2 5/8 3/4 Connecting the cables The power cord of connect should be selected according to the following specifications sheet. Grade Unit mm2 8.3 7K 1,0 12K 1,5 18K 2,5 Pipe length and the elevation Capacity Btu/h 7k~12K 18K 9K 1,0 Pipe size GAS 3/8’’ (φ9.52) 1/2’’ (φ12.7) 1/2’’ (φ12.7) LIQUID 1/4’’ (φ6.35) 1/4’’ (φ6.35) 1/4’’ (φ6.35) Standard length Max. Max. Additional (m) Elevation Elevation refrigerant 5 5 5 B (m) 5 5 8 A (m) 10 10 15 (g/m) 30 30 30 In case that more than 5m. Caution: Capacity is base on standard length and maximum allowance length is base of reliability. Oil trap should be install per 5-7 meters. www.generalclimate.com 15 Wall-Mounted Split Type 8.4 Air purging of the piping and indoor unit Required tools: Hexagonal wrench; adjustable wrench; torque wrenches, wrench to hold the joints and gas leak detector. Note: The air in the indoor unit and in the piping must be purged. If air remains in the refrigeration piping, it will affect the compressor, reduce the cooling capacity, and could lead to a malfunction of unit. Be sure, using a torque wrench to tighten the service port cap (after using the service port), so that it prevents the gas leakage from the refrigeration cycle. Procedure 6. Set the 3-way valve to the opened position. 1. Recheck the piping connections. 7. Mounted the valve stem nuts to the 2-way and 3-way valves. 2. Open the valve stem of the 2-way valve counterclockwise 8. Check for gas leakage. § At this time, especially check for gas leakage from the approximately 90’, wait 10 seconds, and then set it to closed position. 2-way and 3-way stem nuts, and from the service port. § Be sure to use a hexagonal wrench to operate the valve stem Caution: 3. Check for gas leakage. If gas leakage is discovered in step (3) above, take the § Check the flare connection for gas leakage following measures. 4. Purge the air from the system. If the leaks stop when the piping connections are tightened § Set the 2-way valve to the open position and remove the further, continue working from step (4). cap from the 3-way valve’s service port. If the gas leaks do not stop when the connections are § Using the hexagonal wrench to press the valve core pin, retightened, repair the location of the leak, discharge all of discharge for three seconds and then wait for one the gas through the service port, and then recharge with the minute. specified amount of gas from a gas cylinder. 5. Use torque wrench to tighten the service port cap to a torque of 1.8 kg.m. (18n.m) www.generalclimate.com 16 Wall-Mounted Split Type 8.5 Pumping down (Re-installation) Procedure 1. Confirm that both the 2-way and 3-way valves are set to the opened position. § Remove the valve stem caps and confirm that the valve stems are in the opened position. § Be sure to use a hexagonal wrench to operate the valve stems. 2. Operate the unit for 10 to 15 minutes. 3. Stop operation and wait for 3 minutes, then connect the charge set to the service port of the 3-way valve. § Connect the charge hose with the push pin to the gas service port. 4. Air purging of the charge hose. § Open the low-pressure valve on the charge set slightly to purge air from the charge hose. 5. Set the 2-way valve to the close position. 6. Operate the air conditioner at the cooling cycle and stop it when the gauge indicates 0.1MPa. 7. Immediately set the 3-way valve to the closed position. § Do this quickly so that the gauge ends up indicating 0.3 to 0.5Mpa. 8. Disconnect the charge set, and amount the 2-way and 3-way valve’s stem nuts and service port caps. § Use a torque wrench to tighten the service port cap to a torque of 1.8 kg.m. § Be sure to check for gas leakage. www.generalclimate.com 17 Wall-Mounted Split Type 8.6 Re-air purging (Re-installation) Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the closed position. 2. Connect the charge set and a charging cylinder to the service port of the 3-way valve. § Leave the valve on the charging cylinder closed. 3. Air purging. § Open the valves on the charging cylinder and the charge set. Purge the air by loosening the flare nut on the 2-way valve approximately 45’ for 3 seconds then closing it for 1 minutes; repeat 3 times. § After purging the air, use a torque wrench to tighten the flare nut to on the 2-way valve. 4. Check the gas leakage. § Check the flare connections for gas leakage. 5. Discharge the refrigerant. § Close the valve on the charging cylinder and discharge the refrigerant until the gauge indicate 0.3 to 0.5 Mpa. 6. Disconnect the charge set and the charging cylinder, and set the 2-way and 3-way valves to the open position. § Be sure to use a hexagonal wrench to operate the valve stems. 7. Mount the valve stems nuts and the service port cap. § Be sure to use a torque wrench to tighten the service port cap to a torque 18N.m. § Be sure to check the gas leakage. www.generalclimate.com 18 Wall-Mounted Split Type 8.7 Balance refrigerant of the 2-way, 3-way valves Procedure: 1. Confirm that both the 2-way and 3-way valves are set to the open position. 2. Connect the charge set to the 3-way valve’s service port. § Leave the valve on the charge set closed. § Connect the charge hose with the push pin to the service port. 3. Open the valves (Low side) on the charge set and discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. § If there is no air in the refrigeration cycle [the pressure when the air conditioner is not running is higher than 0.1Mpa, discharge the refrigerant until the gauge indicates 0.05 to 0.1 Mpa. If this is the case, it will not be necessary to apply a evacuation. § Discharge the refrigeration gradually; if it is discharged too suddenly, the refrigeration oil sill be discharged. www.generalclimate.com 19 Wall-Mounted Split Type 8.8 Evacuation Procedure: 1. Connect the vacuum pump to the charge set’s centre hose. 2. Evacuation for approximately one hour. § Confirm that the gauge needle has moved toward -0.1 Mpa (-76 cmHg) [vacuum of 4 mmHg or less]. 3. Close the valve (Low side) on the charge set, turn off the vacuum pump, and confirm that the gauge needle does not move (approximately 5 minutes after turning off the vacuum pump). 4. Disconnect the charge hose from the vacuum pump. § Vacuum pump oil, if the vacuum pump oil becomes dirty or depleted, replenish as needle. www.generalclimate.com 20 Wall-Mounted Split Type 8.9 Gas charging Procedure: 1. Connect the charge hose to the charging cylinder. § Connect the charge hose which you disconnected from the vacuum pump to the valve at the bottom of the cylinder. 2. Purge the air from the charge hose. § Open the valve at the bottom of the cylinder and press the check valve on the charge set to purge the air (be careful of the liquid refrigerant). 3. Open the valves (Low side) on the charge set and charge the system with liquid refrigerant. § If the system cannot be charge with the specified amount of refrigerant, if can be charged with a little at a time (approximately 150g each time0 while operating the air conditioner in the cooling cycle; however, one time is not sufficient, wait approximately 1 minute and then repeat the procedure.(pumping down-pin). 4. Immediately disconnect the charge hose from the 3-way valve’s service port. § Stopping partway will allow the refrigerant to be discharged. § If the system has been charged with liquid refrigerant while operating the air conditioner, turn off the air conditioner before disconnecting the hose. 5. Mounted the valve stem caps and the service port § Use torque wrench to tighten the service port cap to a torque of 18N.m. § Be sure to check for gas leakage. www.generalclimate.com 21 Wall-Mounted Split Type 9. Capacity table 9.1 GC/GU-S05CR SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. 9.2 WINTER Indoor Conditions 18ºC 20ºC 22ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 1.41 1.03 0.48 1.53 1.12 0.49 1.63 1.24 0.51 1.81 1.40 0.53 1.33 0.99 0.51 1.46 1.09 0.52 1.56 1.20 0.54 1.74 1.36 0.56 1.23 0.93 0.53 1.37 1.04 0.54 1.47 1.15 0.56 1.68 1.32 0.58 1.13 0.86 0.57 1.29 0.99 0.59 1.39 1.09 0.60 1.57 1.24 0.63 1.06 0.81 0.63 1.20 0.93 0.65 1.30 1.02 0.67 1.43 1.14 0.70 0.98 0.76 0.65 1.11 0.86 0.67 1.19 0.94 0.69 1.35 1.09 0.72 GC/GU-S07HR SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. 15ºC OUTDOOR TEMPERATURE DRY Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. www.generalclimate.com OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 1.97 1.44 0.65 2.13 1.57 0.67 2.27 1.73 0.69 2.53 1.95 0.72 1.85 1.38 0.69 2.04 1.52 0.71 2.17 1.67 0.73 2.43 1.89 0.76 1.71 1.29 0.71 1.90 1.45 0.74 2.05 1.60 0.76 2.35 1.84 0.79 1.58 1.20 0.77 1.80 1.38 0.80 1.94 1.52 0.82 2.18 1.72 0.85 1.47 1.13 0.86 1.68 1.29 0.88 1.81 1.42 0.91 2.00 1.60 0.95 1.37 1.05 0.89 1.55 1.20 0.91 1.66 1.32 0.94 1.88 1.52 0.98 0ºC D -1ºC W 1.85 0.61 1.78 0.63 1.74 0.64 1.71 0.67 -4ºC D -6ºC W 1.59 0.53 1.51 0.55 1.43 0.57 1.41 0.60 -7ºC D -8ºC W 1.40 0.48 1.31 0.49 1.19 0.52 1.16 0.54 OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 2.62 2.30 2.10 0.78 0.71 0.66 2.57 2.26 2.05 0.80 0.72 0.67 2.22 2.55 2.03 0.73 0.83 0.69 2.52 2.20 2.00 0.86 0.74 0.70 22 Wall-Mounted Split Type 9.3 GC/GU-S09HR SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. 15ºC 18ºC 20ºC 22ºC 9.4 WINTER Indoor Conditions 18ºC 20ºC 22ºC 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 2.50 1.82 0.86 2.71 1.99 0.88 2.88 2.19 0.91 3.21 2.47 0.95 2.35 1.75 0.90 2.58 1.93 0.93 2.75 2.12 0.96 3.08 2.40 1.00 2.17 1.64 0.94 2.42 1.84 0.97 2.60 2.03 1.00 2.98 2.34 1.04 2.00 1.52 1.02 2.28 1.75 1.05 2.46 1.93 1.08 2.77 2.19 1.12 1.87 1.43 1.13 2.13 1.64 1.16 2.29 1.80 1.20 2.53 2.02 1.25 1.73 1.34 1.17 1.96 1.52 1.20 2.11 1.67 1.24 2.38 1.93 1.29 0ºC D -1ºC W 2,44 0,82 2,35 0,84 2,29 0,86 2,26 0,90 -4ºC D -6ºC W 2,10 0,72 1,99 0,74 1,89 0,76 1,85 0,81 -7ºC D -8ºC W 1,84 0,65 1,73 0,66 1,56 0,70 1,54 0,72 OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 3,46 3,03 2,78 1,05 0,96 0,89 3,39 2,98 2,71 1,08 0,97 0,90 2,93 2,68 3,36 0,98 1,11 0,93 3,33 2,90 2,64 1,15 0,99 0,95 GC/GU-S12HR SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. 15ºC OUTDOOR TEMPERATURE DRY Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. www.generalclimate.com OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 3.36 2.46 1.05 3.64 2.68 1.09 3.88 2.95 1.12 4.32 3.33 1.16 3.16 2.36 1.11 3.48 2.59 1.15 3.71 2.85 1.18 4.14 3.23 1.23 2.93 2.21 1.16 3.25 2.47 1.19 3.50 2.73 1.23 4.01 3.15 1.28 2.69 2.05 1.25 3.07 2.35 1.29 3.31 2.60 1.33 3.73 2.94 1.38 2.52 1.92 1.39 2.86 2.21 1.43 3.08 2.43 1.48 3.41 2.73 1.54 2.33 1.80 1.43 2.64 2.05 1.48 2.84 2.25 1.53 3.21 2.60 1.59 0ºC D -1ºC W 3.17 1.08 3.06 1.11 2.98 1.14 2.94 1.18 -4ºC D -6ºC W 2.73 0.94 2.59 0.97 2.45 1.00 2.41 1.06 -7ºC D -8ºC W 2.40 0.86 2.25 0.87 2.03 0.92 2.00 0.95 OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 4.50 3.94 3.61 1.38 1.26 1.17 4.41 3.87 3.52 1.42 1.28 1.19 3.81 4.37 3.48 1.29 1.46 1.23 4.33 3.77 3.43 1.51 1.30 1.24 23 Wall-Mounted Split Type 9.5 GC/GU-S18HR SUMMER Cooling mode Indoor Conditions 21ºC D Total capacity kW 15ºC W Sensitive capacity kW Input kW. 24ºC D Total capacity kW 17ºC W Sensitive capacity kW Input kW. 27ºC D Total capacity kW 19ºC W Sensitive capacity kW Input kW. 32ºC D Total capacity kW 23ºC W Sensitive capacity kW Input kW. WINTER Indoor Conditions 15ºC 18ºC 20ºC 22ºC Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. Capacity kW Input kW. www.generalclimate.com OUTDOOR TEMPERATURE DRY 25ºC 30ºC 35ºC 40ºC 45ºC 50ºC 5.08 3.71 1.56 5.49 4.04 1.61 5.85 4.45 1.66 6.52 5.02 1.72 4.77 3.56 1.64 5.25 3.91 1.69 5.59 4.31 1.75 6.25 4.88 1.82 4.41 3.33 1.71 4.91 3.73 1.77 5.28 4.12 1.82 6.05 4.75 1.89 4.06 3.09 1.85 4.64 3.55 1.91 4.99 3.92 1.97 5.62 4.44 2.04 3.80 2.90 2.05 4.32 3.33 2.12 4.65 3.67 2.18 5.14 4.11 2.27 3.52 2.71 2.12 3.98 3.09 2.19 4.29 3.39 2.26 4.84 3.92 2.35 0ºC D -1ºC W 4.64 1.51 4.47 1.55 4.36 1.58 4.30 1.65 -4ºC D -6ºC W 3.99 1.32 3.79 1.36 3.59 1.40 3.53 1.48 -7ºC D -8ºC W 3.51 1.19 3.28 1.21 2.97 1.28 2.92 1.33 OUTDOOR CONDITIONS 12ºC D 7ºC D 4ºC D 11ºC W 6ºC W 3ºC W 6.57 5.76 5.28 1.93 1.76 1.63 6.45 5.66 5.15 1.98 1.78 1.66 5.57 5.09 6.39 1.80 2.04 1.71 6.34 5.51 5.01 2.11 1.82 1.74 24 Wall-Mounted Split Type 10. Electronic function (Just for the 5K, 7K, 9K, 12K, 16K, 18K cooling and heating mode) 10.1 Electronic control working environment Input voltage: 175~253V Input power frequency:50HZ Ambient temperature: -7°C+43°C Indoor fan normal working amp is less than 1A Outdoor fan normal working amp is less than 1.5A Four-way valve normal working amp is less than 1A Swing motor: DC12V Compressor: single-phase power supply. Its normal working amp is less than 15A 10.2 Proper symbols and their meaning TA: Indoor ambient temperature TE: Indoor evaporator temperature TS: Setting temperature through the remote controller I3sec: Self-protection amp of compressor, continue three seconds until turns off the compressor. I5MIN: Self-protection amp of compressor, continue five minutes until turns off the compressor. IFAN: Self-protection amp of outdoor fan/indoor fans when they change from higher wind to lower wind. IRESTORE: Amp self-protection return value THDEFROST: High wind, defrosting temperature difference TM DEFROST: Middle wind, defrosting temperature difference TLDEFROST: Low wind, defrosting temperature difference TE1: Anti-cold wind, from Fan Off to Breeze temperature TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature TE4: Anti-cold wind, from Breeze to Fan Off temperature TE5: Evaporator low temperature protection entering temperature TE6: Evaporator low temperature protection restoring temperature TE7: Evaporator high temperature protection, compressor off temperature TE8: Evaporator high temperature protection, fan off temperature TE9: Evaporator high temperature protection, restoring temperature 10.3 Function Remote receiving Testing and forced running Position set for indoor unit wind vane LED displaying and alarm On or off Timer Protection for the compressor Current protection High temperature protection of indoor heat exchanger at heating mode Auto defrosting and heating recovery at heating mode Anti cold air at heating mode www.generalclimate.com 25 Wall-Mounted Split Type Anti frozen at cooling mode 10.4 Protection 10.4.1 3 minutes delay at restart for compressor. 10.4.2 Sensor protection at open circuit and breaking disconnection 10.4.3 Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High Fan+300RPM)or too low(lower than 400RPM), the unit stops and LED displays failure information and can’t returns to normal operation automatically. 10.4.4 Cross Zero signal error warning. If there is no Cross Zero signals in 4 minutes, the unit stops and LED displays failure information and can’t returns to normal operation automatically. 10.4.5 The current protection of the compressor If compressor turns off for continuously 4 times due to current protection in 5 minutes from Compressor On, the unit stops and LED displays failure information and can’t returns to normal operation automatically. 10.5 Fan-only mode Fan speed is high/mid/low/ Auto 10.6 Cooling mode The 4-way valve is closed at cooling mode. The action of the compressor and the outdoor fan:(T=indoor temperature) www.generalclimate.com 26 Wall-Mounted Split Type Auto fan at cooling mode: Anti-freezing control to indoor evaporator at cooling mode ( T: evaporator temp. ) 10.7 Dehumidifying mode 10.7.1 The 4-way valve is off in dehumidifying mode 10.7.2 Compressor and Indoor Fan actions in dehumidifying mode Block A B C Indoor Fan LOW BREEZE LOW BREEZE LOW BREEZE Compressor and Outdoor Fan ON 6minutes OFF 4minutes ON 5minutes OFF 5minutes ON 4minutes OFF 6minutes Repeat on and off cycle. 10.7.3 Low room temperature protection: When room temperature decreases to below 10℃, compressor and outdoor fan will stop(indoor fan is Breeze). Dehumidifying operation will be resumed when room temperature restores to over 13℃. www.generalclimate.com 27 Wall-Mounted Split Type 10.7.4 At dehumidifying mode, the anti-freezing function of the indoor heat exchanger is the same as that of cooling mode. 10.7.5 At dehumidifying mode, the action of fans of indoor is the same as that of air-only mode. 10.8 Heating mode 10.8.1 Generally, the 4-way valve is open in heating mode, but it is closed in defrosting mode. 4-way valve must delay 2 minutes compared with compressor if the compressor changed into non-heating mode or turned off. 4-way valve doesn't delay in dehumidifying mode 10.8.2 Generally, the outdoor fan is turned off with the on-off action of compressor in heating mode, except for the defrosting mode or the end of defrost 10.8.3 Action of compressor and outdoor fan motor at heating mode: compressor must run for 7 minutes after starting and then judge temperature. Meanwhile other protections are still valid. * This parameter can be changed from 0 to 3 10.8.4 Indoor Fan actions at heating mode Indoor Fan can be set at HIGH/MID/LOW/AUTO by using a remote controller, but Anti-cold wind function prevails. Anti-cold wind control function at heating mode (T=indoor exchanger temp.) 10.8.5 Auto wind at heating mode (T=indoor temp.) www.generalclimate.com 28 Wall-Mounted Split Type 10.8.6 Indoor evaporator high-temperature protection at heating mode (T=indoor exchanger temp.) 10.8.7 The louver opens to Standard Angle ANGLHEAT when power is on for the first time 10.9 Defrosting mode(available for heating mode) Defrosting condition: Defrosting starts when either of the following ①&②: ① A and B are satisfied: A: The compressor keeps running for 40 minutes or more. B: The temperature difference of evaporator and room temperature meets one of the following: ② Calculate from the end of latest defrost, evaporator high temp. Protection only closes outdoor fan with the compressor still running. Add up to 90 minutes. Defrosting time At condition ①, If item B is satisfied before item A, it would be regarded as severe frosting and the defrosting time is 10 minutes. If item B is satisfied after item A, the defrosting time is 6minutes. At condition ②, the defrosting time is 10 minutes. After three times continuous 6-minute defrost, the fourth defrost time should be 10 minutes. The circulation is as following: www.generalclimate.com 29 Wall-Mounted Split Type Ending condition of defrosting If one of following conditions is satisfied, end the defrost and turn into heating mode: A. The defrost time has reached to 6 or 10 minutes. B. The compressor current has reached to IDEFROST or above, IDEROST differs in different models Defrosting Actions Defrost 10 or 6 minutes Compressor 25s 5s 4-way valve 2s Outdoor fan Indoor fan 10s 10.10 Auto mode 10.10.1 The air conditioner automatically selects one of the following operation modes: cooling, heating or fan only according to the temperature difference between room temperature (TA) and set temperature (TS). 10.10.2 The indoor fan blows automatically in corresponding selected mode 10.10.3 The motion of indoor fan’s blade should accord with the selected operation mode 10.10.4 One mode should be carried out for at least 15 minutes once selected. If the compressor cannot start for 15 minutes, reselect the operation mode according to the room temp. and set temp., or reselect when the set temp. varies 10.11 Force cooling function 10.11.1 10.11.2 Select forced cooling function with the forced cooling button or the switch The compressor is unconditionally turned on, after 30 minutes cooling operation whose fan mode is set as low, the A/C operates at the DRY mode with a set temp. of 24℃ 10.11.3 All protections of remote control cooling are available at forced cooling operation www.generalclimate.com 30 Wall-Mounted Split Type 10.11.4 Forced Auto function Select forced auto function with the forced auto button or the switch. In forced auto status the A/C operates at remote control mode with a set temp. of 24℃ 10.12 Sleep mode 10.12.1 10.12.2 The sleep function is available at cooling, heating or auto mode Cooling: The set temperature rise 1℃ per hour. Two hours later, the set temperature will maintain as a constant and the fan speed is kept at low speed. 10.12.3 Heating: The set temperature decrease 1℃ per hour. Two hours later, the set temperature will maintain as a constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all). 10.12.4 Auto: After an hour running under economic mode, the set temp will rise 1℃,if it is under cooling mode; the set temp will decrease 1 ℃,if it is under heating mode; the set temp will be changeless, if it is under fan-only mode; the condition will be the same after the air conditioner running under economic mode after 2 hours, and during the next time the set temp do not change. The total time is 7 hours, after 7 hours the unit stops. 10.13 Auto restart function In case of a sudden power failure, this function automatically sets the unit to previous settings before the power failure when power returns 10.14 Anion (optional) Starts with indoor fan. www.generalclimate.com 31 Wall-Mounted Split Type www.generalclimate.com 32 Wall-Mounted Split Type 11. Model and Parameters Model I3SEC [A] I5MIN [A] IFAN [A] IRESTORE [A] IDEFROST [A] TE1 ['C] TE2 ['C] TE3 ['C] TE4 ['C] TE5 ['C] TE6 ['C] TE7 ['C] TE8 ['C] TE9 ['C] ANGLCOOL ['] ANGLHEAT ['] ANGLOFF ['] THDEFROST ['] TMDEFROST TLDEFROST GC/GU-S05CR GC/GU-S07HR GC/GU-S09HR GC/GU-S12HR GC/GU-S18HR 8,5 8,5 10 11 16 6,2 6,2 7,5 10 13 5,2 5,2 5,5 8 11 4,2 4,2 4.5A 6 9,5 3,2 3,5 5,5 6,5 28 28 28 34 32 32 32 36 30 30 30 30 26 26 20 20 2 2 2 3 3 7 7 7 8 10 60 60 60 60 53 53 53 52 50 50 50 50 200° 200° 200° 200° 50° 0° 0° 0° 105° 124° 124° 124° 124° 0° 16°C 14°C 14°C 17°C ['] 17°C 15°C 15°C 18°C ['] 18°C 16°C 16°C 19°C www.generalclimate.com 33 Wall-Mounted Split Type 12. Troubleshooting 12.1 Display board § Operation The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation. § Timer indicator: The indicator illuminates then TIMER is set ON. § PRE-DEF. indicator (For cooling & heating mode only) The air conditioner starts defrosting automatically if outdoor unit frosts in heating operating. At this time, PRE-DEF. indicator illuminates. § Auto indicator: This indicator flashes when the air conditioner is in AUTO operation. § ECON indicator This indicator illuminates while the air conditioner is in economic operation. 12.2 Troubleshooting For cooling mode: Operation lamp Failure phenomenon ☆ ☆ X On Indoor fan speed has been out of control for over 1 minute Indoor room temp. or evaporator sensor is open circuit or short circuit Over current protection of the compressor occurs 4 times EEROM error No over-zero signal r Extinguish ☆ Flash at 5Hz ☆ Timer lamp X On ☆ ☆ ☆ For heat pump mode: Operation lamp Failure phenomenon Over current protection of the compressor occurs 4 times Indoor fan speed has been out of control for over 1 minute No over-zero signal Temp. sensor on indoor evaporator is open circuit or short circuit Indoor room temp. sensor is open circuit or short circuit EEROM error r Extinguish ☆ Flash at 5Hz www.generalclimate.com 34 ☆ X ☆ X X On Timer lamp X ☆ ☆ X ☆ ☆ Defrosting lamp ☆ ☆ ☆ ☆ X X Wall-Mounted Split Type 12.3 Diagnostic chart After energizing, no indicator is lighted and the air conditioner can’t be operated. www.generalclimate.com 35 Wall-Mounted Split Type 12.4 Resetting phenomenon often occurs during operation. (That is automatically entering to the status when power is on.) The reason is that the instantaneous voltage of main chip is less than 4.5V. Check according to the following procedure: Resetting phenomenon often occurs during operation. Yes After changing indoor PCB, check if the failure realease. Yes Yes Indoor PCB is defective. After changing indoor fan motor, check if the failure realease. YES Power supply circuit has problems. 12.5 Operation lamp flashes and Timer lamp off. 12.6 Operation lamp flashes and Timer lamp on. www.generalclimate.com 36 Wall-Mounted Split Type 12.7 Operation lamp off and Timer lamp flashes 12.8 Operation lamp on and Timer lamp flashes EEROM error, indoor PCB is defective. 12.9 Operation lamp flashes, Timer lamp flashes . This is alarm signal when the main chip can’t detect over-zero signal. When such failure occurs, the main control board must have fault. www.generalclimate.com 37 Wall-Mounted Split Type 13. Characteristic of temperature sensor Temp.℃ Resistance KΩ Temp.℃ Resistance KΩ Temp.℃ Resistance KΩ -10 62.2756 17 14.6181 44 4.3874 -9 58.7079 18 13.918 45 4.2126 -8 56.3694 19 13.2631 46 4.0459 -7 52.2438 20 12.6431 47 3.8867 -6 49.3161 21 12.0561 48 3.7348 -5 46.5725 22 11.5 49 3.5896 -4 44 23 10.9731 50 3.451 -3 41.5878 24 10.4736 51 3.3185 -2 39.8239 25 10 52 3.1918 -1 37.1988 26 9.5507 53 3.0707 0 35.2024 27 9.1245 54 2.959 1 33.3269 28 8.7198 55 2.8442 2 31.5635 29 8.3357 56 2.7382 3 29.9058 30 7.9708 57 2.6368 4 28.3459 31 7.6241 58 2.5397 5 26.8778 32 7.2946 59 2.4468 6 25.4954 33 6.9814 60 2.3577 7 24.1932 34 6.6835 61 2.2725 8 22.5662 35 6.4002 62 2.1907 9 21.8094 36 6.1306 63 2.1124 10 20.7184 37 5.8736 64 2.0373 11 19.6891 38 5.6296 65 1.9653 12 18.7177 39 5.3969 66 1.8963 13 17.8005 40 5.1752 67 1.83 14 16.9341 41 4.9639 68 1.7665 15 16.1156 42 4.7625 69 1.7055 16 15.3418 43 4.5705 70 1.6469 www.generalclimate.com 38 Wall-Mounted Split Type Exploded View Parts for Model : GC-S05CR 220-240V~,50Hz :Indoor unit No. Part 1 Front 2 Name Quantity Sale code 1 10309121201 Air Filter 2 10309121202 3 Screw cap 3 10309121203 4 Panel frame 1 10309121204 5 Air cleaner 1 10109121226 6 Air cleaner holder 1 10109121225 7 Window for receiver 1 10309121207 8 Indicator for LED 1 10309121208 9 Horizontal louver 1 10309121209 10 Vertical louver 12 10309121210 11 Air out frame 1 10309121211 12 Louver holder 1 10309121212 Louver rocker 1 10309121213 Rocker gasket 1 10309121214 14 Louver motor 1 10121121218 15 Drain hose 1 10109121215 16 Indoor temp sensor 1 10109121243 17 Evaporator temp sensor 1 10109121242 Panel 13 www.generalclimate.com 39 Wall-Mounted Split Type 18 Left holder for evaporator 1 10307111202 19 Evaporator 1 10305111201 20 Bearing holder 1 10309121220 21 Cross flow fan, assy 1 10309121221 22 Chassis 1 10309121222 23 Back cover for chassis 1 10309121223 24 Installation Plate 1 10909121002 25 Connecting pipe clamp 1 10309121225 26 Fan motor 1 10309121226 27 Motor cover 1 10309121227 28 E-part box cover 1 10309121228 29 Indicator holder 1 10309121229 30 Display board,Ass'y 1 10407111002 31 Display board enclosure 1 10309121231 32 Main control board 1 10305111001 33 Transformer 1 10718121006 34 E-Parts box 1 10718121007 35 Wire clamp 1 10112121234 36 Wire joint, 5p 1 10407111004 37 Remote Controller 1 10109111203 38 Holder, Remote Controller 1 10109121208 39 Copper nut, TLM-A01 1 10909121012 40 Copper nut, TLM-B02 1 10909121013 www.generalclimate.com 40 Wall-Mounted Split Type Exploded View Parts for Model No. Part 1 GU-S05HR Name 220--240V,50Hz : Outdoor Unit Quantity Sale code Clamp for front net 6 10112121801 2 Front net 1 10109121801 3 Small Handle 1 10109121802 4 Front clapboard 1 10107121801 5 Propeller fan 1 10109121804 6 Fan 1 10109121805 7 Holder for fan motor 1 10109121806 8 Chassis 1 10105121802 9 Compressor 1 10105121801 10 Installation plate for valves 1 10309121809 11 Gas pipe valve 1 10309121810 12 Liquid pipe valve 1 10309121811 13 Fan motor capacitor 1 10109121819 14 Installation board for E-parts 1 10109121820 15 Compressor capacitor 1 10105121803 16 Capacitor 1 10109121822 17 Wire joint 1 10109111802 Motor clamp www.generalclimate.com 41 Wall-Mounted Split Type 18 Separating board 1 10109121813 19 Condenser 1 10107111803 20 Water collector 1 10109121815 21 Right clapboard 1 10109121816 22 Big Handle 1 10109121817 23 Cover 1 10109121818 24 Rear 1 10109121824 Net Exploded View Parts for Model : GC-S07HR No. Part 1 Front 2 Name 220-240V~,50Hz :Indoor Unit Quantity Sale code 1 10309121201 Air Filter 2 10309121202 3 Screw cap 3 10309121203 4 Panel frame 1 10309121204 5 Air cleaner 1 10109121226 6 Air cleaner holder 1 10109121225 7 Window for receiver 1 10309121207 8 Indicator for LED 1 10309121208 9 Horizontal louver 1 10309121209 Panel www.generalclimate.com 42 Wall-Mounted Split Type 10 Vertical louver 12 10309121210 11 Air out frame 1 10309121211 12 Louver holder 1 10309121212 Louver rocker 1 10309121213 Rocker gasket 1 10309121214 14 Louver motor 1 10121121218 15 Drain hose 1 10109121215 16 Indoor temp sensor 1 10109121243 17 Evaporator temp sensor 1 10109121242 18 Left holder for evaporator 1 13008111007 19 Evaporator 1 13008111008 20 Bearing holder 1 10309121220 21 Cross flow fan, assy 1 10309121221 22 Chassis 1 10309121222 23 Back cover for chassis 1 10309121223 24 Installation Plate 1 10909121002 25 Connecting pipe clamp 1 10309121225 26 Fan motor 1 10309121226 27 Motor cover 1 10309121227 28 E-part box cover 1 10309121228 29 Indicator holder 1 10309121229 30 Display board,Ass'y 1 10309121240 31 Display board enclosure 1 10309121231 32 Main control board 1 10307121001 33 Transformer 1 10718121006 34 E-Parts box 1 10718121007 35 Wire clamp 1 10112121234 36 Wire joint, 5p 1 10309121242 37 Remote Controller 1 10109121207 38 Holder, Remote Controller 1 10109121208 39 Copper nut, TLM-A01 1 10909121012 40 Copper nut, TLM-B02 1 10909121013 13 www.generalclimate.com 43 Wall-Mounted Split Type Exploded View Parts for Model No. Part 1 GU-S07HR 220--240V,50Hz : Outdoor Unit Name Quantity Sale code Clamp for front net 6 10112121801 2 Front net 1 10109121801 3 Small Handle 1 10109121802 4 Front clapboard 1 10107121801 5 Propeller fan 1 10109121804 6 Fan 1 10109121805 7 Holder for fan motor 1 10109121806 8 Chassis 1 10107121803 9 Compressor 1 10107121802 10 Installation plate for valves 1 10309121809 Gas pipe valve 1 10309121810 4-way valve 1 10109121812 12 Liquid pipe valve 1 10309121811 13 Fan motor capacitor 1 10109121819 14 Installation board for E-parts 1 13009111005 15 Compressor capacitor 1 10309121820 16 Capacitor 1 10109121822 Motor 11 clamp www.generalclimate.com 44 Wall-Mounted Split Type 17 Wire joint 1 10109121823 18 Separating board 1 10109121813 19 Condenser 1 10107121804 20 Water collector 1 10109121815 21 Right clapboard 1 10109121816 22 Big Handle 1 10109121817 23 Cover 1 10109121818 24 Rear 1 10109121824 Net Exploded View Parts for Model : GC-S09HR 220-240V~,50Hz :Indoor Unit No. Part Name 1 Front 2 Air Filter 3 Screw cap 4 Panel frame 1 10309121204 5 Air cleaner 1 10109121226 6 Air cleaner holder 1 10109121225 7 Window for receiver 1 10309121207 8 Indicator for LED 1 10309121208 9 Horizontal louver 1 10309121209 Panel www.generalclimate.com Quantity Sale code 1 10309121201 2 10309121202 3 45 10309121203 Wall-Mounted Split Type 10 Vertical louver 12 10309121210 11 Air out frame 1 10309121211 12 Louver holder 1 10309121212 Louver rocker 1 10309121213 Rocker gasket 1 10309121214 14 Louver motor 1 10121121218 15 Drain hose 1 10109121215 16 Indoor temp sensor 1 10109121243 17 Evaporator temp sensor 1 10109121242 18 Left holder for evaporator 1 13008111007 19 Evaporator 1 13009111002 20 Bearing holder 1 10309121220 21 Cross flow fan, assy 1 10309121221 22 Chassis 1 10309121222 23 Back cover for chassis 1 10309121223 24 Installation Plate 1 10909121002 25 Connecting pipe clamp 1 10309121225 26 Fan motor 1 10309121226 27 Motor cover 1 10309121227 28 E-part box cover 1 10309121228 29 Indicator holder 1 10309121229 30 Display board,Ass'y 1 10309121240 31 Display board enclosure 1 10309121231 32 Main control board 1 10309121241 33 Transformer 1 10718121006 34 E-Parts box 1 10718121007 35 Wire clamp 1 10112121234 36 Wire joint, 5p 1 10309121242 37 Remote Controller 1 10109121207 38 Holder, Remote Controller 1 10109121208 39 Copper nut, TLM-A01 1 10909121012 40 Copper nut, TLM-B02 1 10909121013 13 www.generalclimate.com 46 Wall-Mounted Split Type Exploded View Parts for Model No. Part 1 GU-S09HR 220-240V~,50Hz :Outdoor Unit Name Quantity SALE Code Clamp for front net 6 10112121801 2 Front net 1 10109121801 3 Front clapboard 1 10109113801 4 Propeller fan 1 10109121804 5 Fan 1 20407111802 6 Holder for fan motor 1 10109121806 7 Chassis 1 10107123802 8 Compressor 1 50309121805 9 Separating board 1 13008111803 10 Cover 1 11609121807 11 Condenser 1 11609121801 12 Installation board ,Left 1 11609121804 13 Rear Net 1 11609121808 14 Right clapboard 1 11607111801 15 Big Handle 1 10109121817 16 Installation plate for valves 1 10309121809 17 Water collector 1 10109121815 18 Capacitor 1 10109121822 19 Compressor capacitor 1 11812113811 20 Fan motor capacitor 1 10112121815 21 Wire joint 1 10109121823 Motor www.generalclimate.com Clamp 47 Wall-Mounted Split Type 22 Washer for wire joint 1 10112121817 23 Wire 1 10112121816 24 Installation board for E-parts 1 13009111005 25 Low Pressure Valve Ass'y 1 11608121806 26 4-Ways valve 1 10109121812 27 Gas pipe valve 1 10309121810 28 High Pressure Valve Ass'y 1 10309121821 29 Liquid pipe valve 1 10309121811 30 Copper nut, TLM-A01 1 10909121012 31 Copper nut, TLM-B02 1 10909121013 Clamp Exploded View Parts for Model : No. Part 1 Front 2 GC-S12HR 220-240V~,50Hz :Indoor Unit Quantity Sale code 1 10309121201 Air Filter 2 10309121202 3 Screw cap 3 10309121203 4 Panel frame 1 10309121204 5 Air cleaner 1 10109121226 6 Air cleaner holder 1 10109121225 7 Window for receiver 1 10309121207 8 Indicator for LED 1 10309121208 www.generalclimate.com Name Panel 48 Wall-Mounted Split Type 9 Horizontal louver 1 10309121209 10 Vertical louver 12 10309121210 11 Air out frame 1 10309121211 12 Louver holder 1 10309121212 Louver rocker 1 10309121213 Rocker gasket 1 10309121214 14 Louver motor 1 10121121218 15 Drain hose 1 10109121215 16 Indoor temp sensor 1 10109121243 17 Evaporator temp sensor 1 10109121242 18 Left holder for evaporator 1 13008111007 19 Evaporator 1 13012111001 20 Bearing holder 1 10309121220 21 Cross flow fan, assy 1 10309121221 22 Chassis 1 10309121222 23 Back cover for chassis 1 10309121223 24 Installation Plate 1 10909121002 25 Connecting pipe clamp 1 10309121225 26 Fan motor 1 10309121226 27 Motor cover 1 10309121227 28 E-part box cover 1 10309121228 29 Indicator holder 1 10309121229 30 Display board,Ass'y 1 10309121240 31 Display board enclosure 1 10309121231 32 Main control board 1 10312121254 33 Transformer 1 10718121006 34 E-Parts box 1 10718121007 35 Wire clamp 1 10112121234 36 Wire joint, 5p 1 10309121242 37 Remote Controller 1 10109121207 38 Holder, Remote Controller 1 10109121208 39 Copper nut, TLM-A01 1 10909121012 40 Copper nut, TLM-C03 1 10912121019 13 www.generalclimate.com 49 Wall-Mounted Split Type Exploded View Parts for Model No. Part 1 GU-S12HR Name 220--240V,50Hz : Outdoor Unit Quantity Sale code Clamp for front net 6 10112121801 2 Front net 1 10109121801 3 Front clapboard 1 13012111801 4 Propeller fan 1 10112121803 5 Fan motor 1 10112111801 6 Holder for fan motor 1 50312121801 7 Chassis 1 11612121801 8 Compressor 1 10112121821 9 Separating board 1 10116113813 10 Small Handle 1 10830121811 11 Cover 1 13012111805 12 Condenser 1 11612121803 13 Installation board,left 1 13012111803 14 Rear net 1 13012111806 15 Right clapboard 1 13012111808 16 Big handle 1 10112121808 17 Installation plate for valves 1 10118113805 18 Water collector 1 10118121832 19 Capacitor clamp 1 10112121814 20 Compressor capacitor 1 30324313020 www.generalclimate.com 50 Wall-Mounted Split Type 21 Fan motor capacitor 1 10112121815 22 Wire joint 1 10109121823 23 Washer for wire joint 1 10112121817 24 Clamp for wiring 1 10112121816 25 Installation board for E-parts 1 15009111801 26 High Pressure Valve Ass'y 1 13012121801 27 Liquid pipe valve 1 10118121830 28 Low pressure Valve Ass'y 1 13012121802 29 4-ways valve 1 10312121852 30 Low-pressure Valve 1 10312121858 31 Copper nut, TLM-A01 1 10909121012 32 Copper nut, TLM-B02 1 10912121019 Exploded View Parts for Model No. Part 1 2 GC-S18HR 220-240V~,50Hz : Indoor Unit Name Quantity Sale code Front panel 1 10318121201 Air filter 2 10318121202 Air cleaner 1 10109121226 Air cleaner holder 1 10109121225 Panel frame 1 10318121203 3 4 www.generalclimate.com 51 Wall-Mounted Split Type 5 Display panel 1 10318121204 6 Protector for temp sensor 1 10112121224 7 Clamp for temp sensor 1 10109121231 8 Horizontal louver,up 1 10318121205 9 Horizontal louver,down 1 10318121206 10 Louver motor 1 10316121202 11 Air out frame 1 10318121208 12 Left holder for evaporator 1 10318121210 13 Evaporator 1 10316121203 14 Bearing holder 1 10318121212 15 Cross flow fan, ass'y 1 10318121213 16 Left cover for chassis 1 10318121214 17 Chassis 1 10318121215 18 Installation plate 1 10318121216 19 Connecting pipe clamp 1 10318121217 20 Underlay for relay 1 10318121218 21 Right cover for chassis 1 10318121219 22 Protection box for relay 1 10318121220 23 Fan motor 1 10318121221 24 Motor cover 1 10318121222 25 Evaporator temp sensor 1 10109121242 26 Indoor temp sensor 1 10109121243 27 Drain 1 10318121223 28 Bush 2 10318121224 29 Louver 12 10318121225 30 Louver holder 2 10318121226 31 Connecting bar for louver 1 10318121227 32 E-part box cover 1 10318121228 33 Transformer 1 10109121204 34 E-parts box 1 10318121230 35 Main control board 1 10316121204 36 Display board,ass'y 1 10316121205 37 Display board enclosure 1 10318121233 38 Wire clamp for power cord 1 10318121234 39 Wire joint, 5p 1 10318121235 40 Wire clamp 1 10112121234 41 Holder, remote controller 1 10109121208 www.generalclimate.com hose 52 Wall-Mounted Split Type 42 Remote controller 1 10109121207 43 Relay 1 10118121238 44 Switch board 1 10109121205 45 Connection pipe for drainage 1 11609121003 46 Sealing ring 1 31009321021 47 Copper nut, TLM-A01 1 10909121012 48 Copper nut, TLM-C03 1 10912121019 Exploded View Parts for Model No. Part 1 GU-S18HR 220-240V~,50Hz : Outdoor Unit Name Quantity Sale code Clamp for front net 6 10112121801 2 Front net 1 10109121801 3 Front clapboard 1 13012111801 4 Propeller fan 1 10112121803 5 Fan motor 1 20412111801 6 Holder for fan motor 1 10312121002 7 Chassis 1 10116113806 8 Compressor 1 10116113807 9 Separating board 1 10116113813 10 Small Handle 1 10830121811 11 Cover 1 13012111805 12 Condenser 1 10116123801 www.generalclimate.com 53 Wall-Mounted Split Type 13 Installation board,left 1 13012111803 14 Rear net 1 13012111806 15 Right clapboard 1 13012111808 16 Big handle 1 10112121808 17 Installation plate for valves 1 10118113805 18 Water collector 1 10118121832 19 Capacitor clamp 1 10118121823 20 Compressor capacitor 1 30324313020 21 Fan motor capacitor 1 10112121815 22 Wire joint 1 10109121823 23 Washer for wire joint 1 10112121817 24 Clamp for wiring 1 10718121809 25 Installation board for E-parts 1 15009111801 26 High Pressure Valve Ass'y 1 10116123802 27 Liquid pipe valve 1 10118121830 28 Low pressure Valve Ass'y 1 10116123803 29 4-way valve 1 10312121852 30 Low-pressure Valve 1 10312121858 31 Copper nut, TLM-A01 1 10909121012 32 Copper nut, TLM-B02 1 10912121019 Climatic Control Corpоration. LLP 29-30 Margaret Street, London W1R 6HH, UK Tel./fax: +44 20 7016 9133 www.generalclimate.com 54 Wall-Mounted Split Type
Title |
File Size |
Download Links |
General Climate AC-N9KRH Instruction Manual.pdf |
777.3kb |
Download |
General Climate CU-S05CR Service Manual.pdf |
1.4Mb |
Download |
General Climate CU-S09HR, CU-S18HR, CU-S12HR, GC-S05CR, CU-S07HR, GC-S07HR, GC-S09HR, GC-S12HR Service Manual.pdf |
1.4Mb |
Download |
General Climate GC/CU-S24HR Service Manual.pdf |
1.3Mb |
Download |
General Climate GC/CU-S30HR, GC/CU-S36HR, GC-S24HR, CU-S24HR Service Manual.pdf |
1.3Mb |
Download |
General Climate GC-S05CR Service Manual.pdf |
2.1Mb |
Download |
General Climate GC-S07CR, GU-S05CR, GU-S07CR, GC-S09CR, GU-S09CR Service Manual.pdf |
2.1Mb |
Download |
General Climate GC-S12CR, GU-S12CR, GC-S18CR, GU-S18CR Service Manual.pdf |
2.1Mb |
Download |
General Climate GC-S18HR, GC/CU-S07HR, GC/CU-S09HR, GC/CU-S12HR, GC/CU-S18HR Service Manual.pdf |
1.4Mb |
Download |
General Climate GC-S30HR, CU-S30HR, GC-S36HR, CU-S36HR Service Manual.pdf |
1.3Mb |
Download |
General Climate is the brand name for HVAC equipment.
General Climate was founded in 2002 in London. This is the Russian-British Association (RBA), which is founded to produce competitive climate technology and is being developed at
the expense of Russian investors.
In the 90s, a Russian businessman Leonid Kiryakov imported General Electric brand air conditioners into Russia and promoted them in the domestic market. But before these air conditioners had time
to gain popularity in Russia, as General Electric Corporation decided to curtail the climatic direction. And in 2002, Leonid Kiryakov decided to promote a new brand — General Climate.
The production and quality control in the General Climate group is carried out by the British company Climatic Control Corporation (headquarters in London).
Today, under the brand name General Climate, a wide range of climatic equipment is produced: household air conditioners, ventilation and heating equipment, chillers and fan
coils, large refrigeration systems and household air humidifiers.
Описание
Неинверторная сплит-система General Climate GC/GU-S12HRIN1 отличается надежностью при интенсивном использовании в условиях высоких нагрузок.
В кондиционере General Climate GC/GU-S12HRIN1 установлен ионизатор, благодаря которому он имеет несколько неоспоримых преимуществ:
Ионизация воздуха оказывает антибактериальный эффект.
Анионы, перемещаясь в помещении, сталкиваются бактериями и спорами. При этом они превращаются в гидроксигруппы (ОН) и разрушают оболочки бактерий. Воздух очищается во всем помещении от бактерий, грибов, плесени. Возможно с этим и связана целебная сила ионов по защите человека от болезней.
Ионизация воздуха помогает устранить неприятные запахи и табачный дым.
Сталкиваясь с молекулами загрязнений и неприятных запахов, анионы расщепляют их на безвредные вещества. Различные стойкие запахи и табачный дым удаляются без следа за 5-6 минут работы ионизатора. Учитывая объем воздуха захватываемого кондиционером — ионизация с его помощью идеальное средство для борьбы с дымом в доме курильщика.
Ионизация удаляет из воздуха некоторые нежелательные и опасные химические соединения.
В помещении могут находиться источники нежелательных химических соединений, которые проникают в воздух: предметы, обработанные химическими средствами, вредные материалы и аэрозоли.
Отличительные особенности:
Режим «Турбо»
В режиме «Турбо» (форсированном режиме) кондиционер работает после включения некоторое время с повышенной мощностью. Это позволяет быстрее достичь желаемой температуры в помещении.
Оптимальная форма теплообменника
Во всех настенных кондиционерах General Climate установлен специальный трех> или четырехсекционный теплообменник. Конструкция теплообменника внутреннего блока позволила увеличить площадь теплообмена на 32% при сохранении компактных размеров теплообменника.
В результате производительность настенных кондиционеров возросла, а размеры внутренних блоков меньше, чем у аналогичных кондиционеров других марок.
Специальная конструкция вентиляторов
Во внутренних блоках кондиционеров General Climate установлены тангенциальные вентиляторы большого диаметра. Их конструкция позволяет снизить скорость вращения и, соответственно, уменьшить шум, без снижения мощности кондиционера и потока воздуха. Во внешних блоках кондиционеров General Climate установлены экономичные вентиляторы осевого типа с высокими аэродинамическими показателями.
Медные трубки с повышенной площадью теплообмена
На внутренних поверхностях медных трубок теплообменников кондиционеров General Climate имеются канавки и выступы с сечением в форме трапеций. При таком оребрении улучшается теплообмен между протекающим по трубкам хладагентом и пластинами теплообменника.
Легко смачиваемые теплообменники
Теплообменник внутреннего блока состоит из медных трубок с алюминиевым оребрением.
Оребрение легко смачивается водой, поэтому конденсат свободно стекает по алюминиевым пластинам, а не скапливается на поверхности теплообменника. Благодаря этому повышается эффективность теплообмена.
Автоматический перезапуск
Настенные кондиционеры General Climate автоматически возобновляют работу в прежнем режиме после перерыва в подаче электропитания (функция Auto>Restart).
Режим SLEEP
Во время сна человек меньше двигается, поэтому ему требуется менее интенсивное охлаждение. «Sleep Mode», или режим «СОН», создает идеальные условия для отдыха – оптимальную температуру и низкий уровень шума вентилятора. Продолжительность режима – 7 часов (обычная длительность ночного сна). В режиме «СОН» вентилятор внутреннего блока переключается на малые обороты, чтобы снизить шум. Температура постепенно меняется.
Оптимальное направление потока воздуха
Как говорилось выше, под действием естественной конвекции теплый воздух поднимается к потолку, а холодный – опускается вниз, к полу. Это создает «неудобную» разницу температур между потолком и полом. Жалюзи настенных кондиционеров General Climate могут изменять направление воздушного потока в зависимости от режима работы. В режиме охлаждения холодный воздух подается вверх, в режиме обогрева – теплый воздух подается вниз. Таким образом, обеспечивается правильная циркуляция и равномерное перемешивание воздуха в помещении.
Самодиагностика кондиционера и защита от поломок
Микросхема, встроенная в настенные кондиционеры General Climate, самостоятельно выполняет диагностику неполадок. Сигналы о возникших неисправностях отображаются на световых индикаторах внутреннего блока сплит>системы. При необходимости автоматически включается система защиты от поломок. Новая технология позволяет вовремя обнаружить утечку хладагента и предотвратить выход оборудования из строя.
Антикоррозионный корпус внешнего блока кондиционера
Металлические поверхности внешнего блока кондиционеров General Climate надежно защищены от коррозии. Корпус внешнего блока изготовлен из оцинкованной стали и имеет дополнительное антикоррозионное покрытие. Это защищает кондиционер даже в самых сложных погодный условиях, при высокой влажности и больших перепадах температур.
Функция «таймер»
Кондиционер позволяет осуществить программирование включения / выключения системы по таймеру в диапазоне до 24 часов.
Функция «следуй за мной»
Кондиционер создает комфортную температуру именно в том месте помещения, где находится пульт ДУ. Кондиционер реагирует на показания температурного датчика встроенного в пульт дистанционного управления, автоматически настраиваясь на комфортный режим.
Функция «самоочистки»
При нажатии кнопки «Clean» на пульте дистанционного управления, внутренний блок начинает самоочистку испарителя, борется с размножением бактерий в блоке, сохранить свежесть воздуха.
Характеристики
Общие характеристики |
|
|
настенная сплит-система |
|
27 |
|
охлаждение/обогрев |
|
нет |
|
3 года |
Мощность охлаждения/обогрева |
|
|
3500 |
|
3800 |
|
1100 |
|
1000 |
|
12000 |
Технические характеристики |
|
|
однофазный |
|
8.0 |
|
33/39 |
|
52 |
|
от +18 до +43 °C |
|
от -7 до +24 °C |
|
20 |
|
8 |
|
1/4″ (6.35мм) |
|
1/2″ (12.7мм) |
|
R 410A |
|
50/220-240 |
Управление |
|
|
беспроводной |
|
есть |
|
есть |
|
есть |
|
индикаторы режимов работы на корпусе / дисплей с режимами работы на пульте |
|
нет |
Режимы и функции |
|
|
ночной режим / турбо режим / режим вентиляции / автоматический режим / ионизация воздуха / режим осушения |
|
нет |
|
нет |
Конструкция |
|
|
есть |
Размеры, вес, цвет |
|
|
750x250x198 |
|
750х250х198 |
|
8 |
|
26 |
Цвет | белый |
Артикул |
62747 |
Подберите похожие по характеристикам товары, выбрав одно или несколько свойств
Выбрано: 0
Подобрать
Доставка (450 р.)
Бренд | General Climate |
Охлаждающая способность (BTU) | 12000 |
Минимальный уровень шума внутреннего блока (дБ) | 35 |
Максимальный уровень шума внутреннего блока (дБ) | 41 |
Тип хладагента | R 410A |
Мощность в режиме охлаждения (Вт) | 3500 |
Потребляемая мощность при охлаждении (Вт) | 1230 |
Тип конструкции | настенная сплит-система |
Основные режимы | охлаждение / обогрев |
Максимальный воздушный поток (куб. м/мин) | 9.167 |
Количество скоростей вентилятора | 3 |
Регулировка скорости вращения вентилятора | есть |
Таймер включения/выключения | есть |
Ночной режим | есть |
Функция запоминания настроек | есть |
Генератор анионов | есть |
Фильтры тонкой очистки воздуха | есть |
Пульт дистанционного управления | есть |
Самодиагностика неисправностей | есть |
Фаза | однофазный |
Высота внутреннего блока (см) | 25 |
Ширина внутреннего блока (см) | 75 |
Глубина внутреннего блока (см) | 18.8 |
Высота внешнего блока (см) | 54 |
Ширина внешнего блока (см) | 78 |
Глубина внешнего блока (см) | 25 |
Мощность в режиме обогрева (Вт) | 3800 |
Потребляемая мощность при обогреве (Вт) | 1290 |
Дезодорирующий фильтр | есть |