    2. Electric air conditioner portable type CONTENTS EN 1.Important information 3 2.Precautions 3 3.Technical characteristics 4 4.Description of portable air conditioner 6 5.Control panel air conditioner 7 6.Maintenance 9 7.Service life 10 8.Rules of disposal 10 9.Helpful advice 10 10.Troubleshooting

  • Страница 3 из 53

    Electric air conditioner portable type 3. Dear Customer! Thank you for a shrewd choice and purchase of Hyundai portable electric air conditioner. It will serve you for a long time. 1. IMPORTANT INFORMATION 1. Please read this instruction manual carefully prior to installation and operation of a

  • Страница 4 из 53

    4. Electric air conditioner portable type 13. To avoid electric shock, a damaged power cord must be replaced only by an authorized service center and qualified specialists. 14. Prior to disposal of the device, it is necessary to remove batteries from it, after that they can be safely disposed. 15.

  • Страница 5 из 53

    5. Electric air conditioner portable type 3.TECHNICAL CHARACTERISTICS Tab.1 Model H-AP2-07C-UI002 H-AP2-09C-UI003 Capacity (cooling) kW 2,05 2,71 Rated input (cooling) W 810 1030 Voltage V/Hz 220~240/50 220~240/50 Rated current (cooling) A 3.5 4.7 Air circulation m3/h 370/320 370/320 Capacity of

  • Страница 6 из 53

    6. Electric air conditioner portable type 1 3 4 2 6 9 10 7 12 5 11 8 Fig. 3 Fig. 2 4. DEVICE DESCRIPTION (Fig. 2 and 3) EN 1. Control panel 2. Horizontal louver 3. Handle 4. Remote signal receptor 5. Panel 6. Air filter 7. Air outlet grille 8. Rollers 9. Air inlet grille 10. Condensation drain hole

  • Страница 7 из 53

    7. Electric air conditioner portable type 5. CONTROL OF PORTABLE AIR CONDITIONER 5 3 4 2 6 1 8 7 Fig. 5 Control panel 1. POWER button. Press this button to switch on or off the unit. 2. MODE button. Press this button to select the mode of dehumidification or cooling. 3. TEMP up button. In the

  • Страница 8 из 53

    8. Electric air conditioner portable type Note This function is not accessible in the fan/drying modes. When power supply is turned off, the sleep mode is automatically switched off. When the unit is turned off, settings of the sleep mode are automatically turned off. Indicators for operating mode:

  • Страница 9 из 53

    9. Electric air conditioner portable type NOTE: In dehumidification mode, remove the rubber plug of the drainage hose, install the respective drainage hose (not in the set). Disconnect the air outlet hose, connect the drainage hose to the drainage hole and drain water from the unit to ensure

  • Страница 10 из 53

    10. Electric air conditioner portable type Fig. 8 Installation of the filter is performed in the reverse order. Filter cleaning At first, carefully clean the filters by means of vacuum cleaners. Then immerse the filter in warm water (about 40°C) with a soft detergent, wash it and dry it without

  • Страница 11 из 53

    11. Electric air conditioner portable type ELECTRIC POWER SUPPLY Make sure characteristics of the mains correspond to characteristics of the unit. Insert the plug in the socket securely to avoid overheating and risk of fire. Do not pull the power cord with excessive force: it may damage it.

  • Страница 12 из 53

    12. Electric air conditioner portable type 10. TROUBLESHOOTING Trouble Cause Troubleshooting method The air conditioner is not switched on when Power button is pressed The tank fill-up indicator is flashing, the condensate collection tray is filled up Drain water from the tray Loud noise or strong

  • Страница 13 из 53

    Electric air conditioner portable type 13. Such marking indicates that disposal of this product along with other domestic waste is forbidden in the EU. To prevent environmental or health damage as a result of uncontrolled waste disposal, please hand this product for recycling to enable rational use

  • Страница 14 из 53

    14. Электрический кондиционер воздуха мобильного типа Содержание RU 1. Важная информация 14 2. Меры предосторожности 15 3. Технические характеристики 17 4. Описание мобильного кондиционера 18 5. Управление мобильным кондиционером 19 6. Обслуживание 21 7. Срок эксплуатации 22 8. Правила утилизации

  • Страница 15 из 53

    Электрический кондиционер воздуха мобильного типа 15. Уважаемый покупатель! Благодарим Вас за удачный выбор и приобретение электрического мобильного кондиционера воздуха Hyundai. Он прослужит Вам долго. 1. ВАЖНАЯ ИНФОРМАЦИЯ 1. Просим внимательно ознакомиться с инструкцией по эксплуатации перед

  • Страница 16 из 53

    16. Электрический кондиционер воздуха мобильного типа 11. Для работы компрессора необходим ток силой как минимум 10А. Во избежание перегрева и риска возникновения пожара, а также повреждения внутренней электрической сети, не включайте устройство в удлинители. 12. Устройство предназначено для

  • Страница 17 из 53

    17. Электрический кондиционер воздуха мобильного типа 3.ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ Таблица 1 Модель H-AP2-07C-UI002 H-AP2-09C-UI003 Мощность (охлаждение) кВт 2,05 2,71 Потребляемая мощность (охлаждение) Вт 810 1030 Напряжение питания В/Гц 220~240/50 220~240/50 Сила тока (охлаждение) А 3.5 4.7

  • Страница 18 из 53

    18. Электрический кондиционер воздуха мобильного типа 1 3 4 2 6 9 10 7 12 5 11 8 Рис. 3 Рис. 2 13 4. ОПИСАНИЕ МОБИЛЬНОГО КОНДИЦИОНЕРА (рис.2 и 3) RU 1. Панель управления 2. Горизонтальные жалюзи 3. Ручка для переноски 4. Приемник сигнала с пульта управления 5. Панель 6. Фильтр для очистки воздуха

  • Страница 19 из 53

    19. Электрический кондиционер воздуха мобильного типа 5. УПРАВЛЕНИЕ МОБИЛЬНЫМ КОНДИЦИОНЕРОМ 5 3 4 2 6 1 8 7 Рис. 5 1. Кнопка включения-выключения (POWER). Нажать для включения или отключения устройства. 2. Кнопка выбора режима работы (MODE). Нажмите эту кнопку для выбора режима осушения, вентиляции

  • Страница 20 из 53

    20. Электрический кондиционер воздуха мобильного типа 8. Кнопка режима ночной (SLEEP): при нажатии этой кнопки установленная температура увеличивается (при охлаждении) или уменьшается (при обогреве) на 1 градус через 30 минут после включения этой функции. Температура увеличивается (при охлаждении)

  • Страница 21 из 53

    Электрический кондиционер воздуха мобильного типа 21. для инициации таймера выключения. 9. Кнопка «TIMER ON». Нажмите эту кнопку для инициации таймера включения. 10. Кнопка «FAN». С помощью данной кнопки можно выбрать скорость вращения вентилятора внутреннего блока: Автоматическая «Auto», Высокая

  • Страница 22 из 53

    22. Электрический кондиционер воздуха мобильного типа Воздушный фильтр Засорение воздушного фильтра частицами пыли снижает эффективность работы кондиционера, поэтому проводите чистку фильтра не реже одного раза в две недели. Извлечение/установка фильтра Извлеките воздушный фильтр в направлении,

  • Страница 23 из 53

    Электрический кондиционер воздуха мобильного типа 23. местах с ограниченным свободным пространством. В случае опасной утечки тока не пользуйтесь устройством при высокой влажности. Берегите устройство от воздействия прямых солнечных лучей: на нем могут поблекнуть краски. Устройство имеет функцию

  • Страница 24 из 53

    24. Электрический кондиционер воздуха мобильного типа 10. УСТРАНЕНИЕ НЕИСПРАВНОСТЕЙ Неисправность Причина Способ устранения При нажатии кнопки «Power» кондиционер не включается. Мигает индикатор заполнения Емкости, лоток для сбора конденсата заполнен Слейте воду из лотка Сильный шум или вибрация

  • Страница 25 из 53

    Электрический кондиционер воздуха мобильного типа 25. Такая маркировка означает, что на территории ЕС утилизация данного изделия совместно с другими бытовыми отходами запрещена. Во избежание ущерба окружающей среде или здоровью окружающих вследствие неконтролируемой утилизации отходов просим сдать

  • Страница 26 из 53

    26. Электрический кондиционер воздуха мобильного типа 11. СЕРТИФИКАЦИЯ При отсутствии копии нового сертификата в коробке, спрашивайте копию у продавца. RU

  • Страница 27 из 53

    Электрический кондиционер воздуха мобильного типа 27. Уважаемый покупатель! Мы всегда рады предложить Вашему вниманию удобные пользовательские сервисы и продукты, нацеленные на то, чтобы сделать использование и обслуживание техники Hyundai еще более комфортным и удобным. Именно поэтому мы

  • Страница 28 из 53

    Гарантийный талон RU Территория действия: Российская Федерация Уважаемый покупатель! Обратите особенное внимание на стр. 40 Действителен с Января 2014 года

  • Страница 29 из 53

    29. Electric air conditioner portable type Гарантийные обязательства Бытовое изделие Hyundai Гарантийное обслуживание и ремонт бытовой техники Hyundai с соблюдением требований и норм Изготовителя (Hyundai) производятся на территории РФ только в фирменных сервисных центрах Изготовителя или

  • Страница 30 из 53

    30. Electric air conditioner portable type • электрических водонагревателей проточного типа — 3 года; • электрических водонагревателей накопительного типа — 10 лет; • остальных изделий — от 3 до 5 лет. Указанные сроки службы действительны только при условии соблюдения правил эксплуатации и

  • Страница 31 из 53

    31. Electric air conditioner portable type Изготовитель оставляет за собой право: • отказать в гарантийном сервисном обслуживании изделия в случае несоблюдения изложенных ниже условий (cм. «Досрочное прекращение гарантийного обслуживания»); • самостоятельно инициировать независимую экспертизу для

  • Страница 32 из 53

    32. Electric air conditioner portable type • отсутствием товарного или кассового чека о продаже изделия или невозможностью определить продавца изделия; • наличием следов механических повреждений, возникших после передачи изделия потребителю и явившихся возможной причиной возникновения дефекта; •

  • Страница 33 из 53

    Electric air conditioner portable type 33. Изготовитель не несет гарантийных обязательств за изделие в следующих случаях: • если изделие использовалось в иных целях, не соответствующих его прямому назначению в соответствии с Руководством по эксплуатации; • если на изделии отсутствует маркировочная

  • Страница 34 из 53

    34. Electric air conditioner portable type запуск в эксплуатацию самим потребителем. Организация, производящая запуск в эксплуатацию и/или последующее сервисное обслуживание газового оборудования, должна иметь лицензии и/или разрешения на соответствующий вид деятельности (вид работ), а специалисты

  • Страница 35 из 53

    35. Electric air conditioner portable type Таблица 1 Рекомендуемые профилактические работы для увеличения срока гарантии на внутреннюю ёмкость водонагревателя и нагревательный(-е) элемент (-ы), а также для выполнения условия долговременной работы водонагревателя в рамках заявленного срока службы и

  • Страница 36 из 53

    36. Electric air conditioner portable type Первоначальная проверка состояния магниевого анода, интенсивности его разложения, определения сроков последующей проверки и замены магниевого анода, а также при необходимости его замены. Через первые 0,5 года после начала эксплуатации Через первые 0,5 года

  • Страница 37 из 53

    37. Electric air conditioner portable type Таблица 1 Рекомендуемые профилактические работы для увеличения срока гарантии на компрессор кондиционера, а также для выполнения условия долговременной работы кондиционера, в рамках заявленного срока службы и более. Наименование рекомендуемых

  • Страница 38 из 53

    38. Electric air conditioner portable type ВНИМАНИЕ! Если вы устанавливаете электрический конвектор без защиты от опрокидывания на ножки, то гарантия на прибор считается аннулированной, и потребитель осуществляет ремонт прибора полностью за свой счет. Электрические конвекторы с защитой от

  • Страница 39 из 53

    39. Electric air conditioner portable type PRODUCTION ID: SERIAL NUMBER: UNIT CODE: обслуживания. Если пользователь пропускает хотя бы одно обслуживание, то увеличенная гарантия на указанный компонент перестает действовать, и гарантия остается стандартной, как на весь прибор в целом. Перечень

  • Страница 40 из 53

    40. Electric air conditioner portable type Покупатель информирован о том, что он не вправе требовать возврата или обмена купленного изделия в порядке статьи 25 Закона «О защите прав потребителей» и статьи 502 Гражданского Кодекса РФ в соответствии с п.11 «Перечня непродовольственных товаров

  • Страница 41 из 53

    Гарантийный талон ВНИМАНИЕ! Пожалуйста, потребуйте от продавца полностю заполнить гарантийный талон и отрывные талоны. Заполняется фирмой-продавцом Изделие Модель Серийный номер Дата продажи Фирма-продавец Адрес фирмыпродавца Телефон фирмы -продавца Без подписи покупателя на странице 40 Гарантийный

  • Страница 42 из 53

    Заполняется сервисным центром «A» Дата приема Дата выдачи Особые отметки Печать сервисного центра «Б» Дата приема Дата выдачи Особые отметки Печать сервисного центра «В» Дата приема Дата выдачи Особые отметки Печать сервисного центра «Г» Дата приема Дата выдачи Особые отметки Печать сервисного

  • Страница 43 из 53

    Дата приема Дата выдачи Особые отметки Номер заказа-наряда Проявление дефекта Печать сервисного центра Мастер Код неисправности Заполняется сервисным центром Дата приема Дата выдачи Особые отметки Номер заказа-наряда Проявление дефекта Печать сервисного центра Мастер Код неисправности Заполняется

  • Страница 44 из 53

    Отрывной талон «A» Изделие Модель Серийный номер Дата продажи Печать сервисного центра Фирма-продавец Заполняется фирмой-продавцом Отрывной талон «Б» Дата приема Дата выдачи Особые отметки Номер заказа-наряда Проявление дефекта Печать сервисного центра Мастер Код неисправности Заполняется

  • Страница 45 из 53

    Профилактическое обслуживание изделия. (Заполняется специалистом авторизованного сервисного центра Hyundai) №№ Дата Перечень выполненных работ выполнения работ Наименование СЦ Ф.И.О. исполнителя, подпись, печать

  • Страница 46 из 53

    Профилактическое обслуживание изделия. (Заполняется специалистом авторизованного сервисного центра Hyundai) №№ Дата Перечень выполненных работ выполнения работ Наименование СЦ Ф.И.О. исполнителя, подпись, печать

  • Страница 47 из 53

    47. Electric air conditioner portable type Страна Наименование сервисного цетра Код Телефон города Фактический адрес, электронный адрес Примечание Россия ООО «Авангард Холго» (495) г. Москва, Ленинградское ш., д. 57, корп.12, 2 этаж Единая сервиcноинформационная служба на территории России.

  • Страница 48 из 53

    48. RU Электрический кондиционер воздуха мобильного типа KO 제품 품질 보증 쿠폰은 해당 지역 디스트리뷰터에 요청하시기 바랍니다. EN Ask distributor of your region for Warranty Coupon of a product. ES Pida la garantía al distribuidor en su país. KZ Бұйымның кепілдік талонын сатылған ел аумағындағы дистрибьютордан сұрастырыңыз.

  • Страница 49 из 53

    Гарантийный талон 49. RU

  • Страница 50 из 53

    50. RU Гарантийный талон

  • Страница 51 из 53

    Гарантийный талон 51. RU

  • Страница 52 из 53

    Licensed by Hyundai Corporation, Korea www.hyundai-hvac.com

  • Страница 53 из 53
  • Скачать

    Страница из 52

    RU

    Электрический кондиционер 

    воздуха мобильного типа

    Руководство по эксплуатации.
    Гарантийный талон.

    Electric air conditioner

    portable type

    Instruction manual.

    Warranty card.

    EN

    Модели / Models

    H-AP2-07C-UI002

    H-AP2-09C-UI003

    www.hyundai-hvac.com

    • Инструкции по эксплуатации

      1

    Preview

    HYUNDAI H-AP2-07 C-UI 002 инструкция по эксплуатации
    (52 страницы)

    • Языки:Русский
    • Тип:
      PDF
    • Размер:
      2.38 MB
    • Описание:
      Мобильный кондиционер

    Просмотр

    На NoDevice можно скачать инструкцию по эксплуатации для HYUNDAI H-AP2-07 C-UI 002. Руководство пользователя необходимо для ознакомления с правилами установки и эксплуатации HYUNDAI H-AP2-07 C-UI 002. Инструкции по использованию помогут правильно настроить HYUNDAI H-AP2-07 C-UI 002, исправить ошибки и выявить неполадки.

    Specifications:

    1078/1078949-hap207cui002.pdf file (30 Nov 2022)

    Accompanying Data:

    Hyundai H-AP2-07C-UI002 Air Conditioner PDF Instruction Manual (Updated: Wednesday 30th of November 2022 03:47:59 AM)

    Rating: 4.7 (rated by 84 users)

    Compatible devices: H-ARI17-07H/I, HACM09DB — HCCM99DB, H-ALD3-18H/I, WSH-071NBE, HYAP9BC, H-AC-07H1 I, HSH-P182NDC, H-ALMS2-07H/I.

    Recommended Documentation:

    Text Version of Instruction Manual

    (Ocr-Read Summary of Contents of some pages of the Hyundai H-AP2-07C-UI002 Document (Main Content), UPD: 30 November 2022)

    • 38, 38. EN Electric air conditioner portable type ВНИМАНИЕ! Если вы устанавливаете электрический конвектор без защиты от опрокидывания на ножки, то гарантия на прибор считается аннулир…

    • 2, 2. EN Electric air conditioner portable type CONTENTS 1.Important information 2.Precautions 3.Technical characteristics 4.Description of portable air conditioner 5.Control panel air conditioner 6.Maintenance 7.Service life 8.Rules of disposal 9.Helpful advice 10.Troubleshooting 3 3 4 6 7 9 10 10 10…

    • 22, Hyundai H-AP2-07C-UI002 22. Электрический кондиционер воздуха мобильного типа RU Рис. 8 Воздушный фильтр Засорение воздушного фильтра частицами пыли снижает эффективность работы кондици�…

    • 8, 8. EN Electric air conditioner portable type Indicators for operating mode: Cool — cooling mode indicator Dry — dry mode indicator Fan — fan mode indicator Auto — auto mode indicator Hight — hight speed fan indicator Low — low speed fan indicator REMOTE CONTROL 1. Button «ON/OFF». Using this button, you may tu…

    • Hyundai H-AP2-07C-UI002 User Manual

    • Hyundai H-AP2-07C-UI002 User Guide

    • Hyundai H-AP2-07C-UI002 PDF Manual

    • Hyundai H-AP2-07C-UI002 Owner’s Manuals

    Recommended: HE63 HE73 HE93, IG-A40UW, 1500

    • Mitsubishi Electric MFZ-KW25VG

      FLOOR-TYPE AIR CONDITIONERSINDOOR UNITMFZ-KW25VG MFZ-KW35VG MFZ-KW42VG MFZ-KW50VG MFZ-KW60VGEnglishOPERATING INSTRUCTIONS For user• To use this unit correctly and safely, be sure to read these operating in-structions before use. …

      MFZ-KW25VG 16

    • Sanyo CMH1972A

      NoticeCORRECTIONSERVICE FLASHPRODUCTION CHANGEADDED INFORMATIONREFERENCE NO. SM700855-02FILE NO.Page No.of the ManualContentsThe following unit specification has been corrected.Number of Operatable Indoor Units : 3 4Reasonfor changePlease add this notice to the TECHNICAL & SERVICE MANUAL lis …

      CMH1972A 134

    • Ingersoll-Rand YSC036G

      SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed, adjusted or altered equipment by an un …

      YSC036G 82

    • Hitachi RAC-25FXE

      ROOM AIR CONDITIONEROUTDOOR UNITSERVICE MANUALTECHNICAL INFORMATIONSPECIFICATIONSAfter installationOUTDOOR UNITJohnson Controls-Hitachi Air Conditioning Wuhu Co., Ltd.JCH-WHFOR SERVICE PERSONNEL ONLYRAC-50FXERAC-25FXE RAC-35FXE OUTDOOR UNIT OUTDOOR UNIT OUTDOOR UNITRAC-25 RAC-35 RAC-50(KW)(B.T.U./ …

      RAC-25FXE 60

    Additional Information:
    Popular Right Now:

    Operating Impressions, Questions and Answers:

    Электрический кондиционер

    RU

    воздуха мобильного типа

    Руководство по эксплуатации.

    Гарантийный талон.

    Electric air conditioner

    portable type

    EN

    Instruction manual.

    Warranty card.

    Модели / Models

    H-AP2-07C-UI002 H-AP2-09C-UI003

    www.hyundai-hvac.com

    2.

    Electric air conditioner

    portable type

    CONTENTS

    1.Important information

    3

    2.Precautions

    3

    3.Technical characteristics

    4

    4.Description of portable air conditioner

    6

    5.Control panel air conditioner

    7

    6.Maintenance

    9

    7.Service life

    10

    8.Rules of disposal

    10

    9.Helpful advice

    10

    10.Troubleshooting

    12

    EN

    Electric air conditioner

    3.

    portable type

    Dear Customer!

    Thank you for a shrewd choice and purchase of Hyundai portable electric air conditioner. It will serve you for a long time.

    1. IMPORTANT INFORMATION

    1.Please read this instruction manual carefully prior to installation and operation of a portable air conditioner.

    2.To avoid damage to the air conditioner and voiding your guarantee, before start using the air conditioner put the device in a vertical position (as shown on the cover of this instruction manual) for at least 2 hours prior to operation.

    3.There may be misprints in the text and digital symbols in this manual.

    4.If after reading the manual you would still have questions regarding functioning and operation of the device, please contact the seller or a specialized service center for clarifications.

    5.The device has a tag indicating all necessary technical data and other useful information about the device.

    6.Use the device only as designated by this manual.

    7.Prior to installation of the portable air conditioner, not connecting it to the mains, check and make sure that the mains socket for the air conditioner has a grounding pin and is properly grounded.

    8.In case there is no grounding pin in your mains, operation of the portable air conditioner is life-threatening.

    9. Do not use adapters and extension cords to connect your portable air conditioner.

    10.Improper installation and use of this air conditioner may lead to severe injuries or damage to your property.

    11.Any maintenance must be performed by a specialized company and qualified specialists.

    EN

    2. PRECAUTIONS

    1.Do not block vents!

    2.Make sure the inlet and outlet vent is not blocked.

    3.Do not insert foreign objects into the air diffuser of the air conditioner. It is very dangerous since the fan rotates at high speed.

    4.Install the device only on a horizontal surface to prevent condensed water leakage.

    5.Do not install the floor-mounted air conditioner in the following places:

    in places exposed to direct sunlight;

    in the vicinity of open fire sources;

    in the vicinity of other operating heating devices;

    in places where water or steam splashes can contact the device;

    in rooms with increased humidity;

    close to swimming pools, bathrooms and shower rooms.

    6.Do not use the device in an explosive or corrosive environment. Do not store gasoline and other volatile flammable liquids near the air conditioner – it is very dangerous!

    7.Use the device to cool down air at ambient temperature 17-32°C.

    8.Regularly clean filters to ensure efficient operation of the device.

    9.To ensure reliable operation of the compressor, do not tilt the air conditioner.

    10.If the device is disconnected, restarting must be performed not sooner than in 3.5 minutes to prevent the compressor failure.

    11.At least 10 A current is required for the compressor to operate. To avoid overheating and fire risk, as well as damage to the inner electrical circuit, do not connect the device through extension cords.

    12.The device is designed to cool and dry air only in residential conditions and cannot be used for industrial purposes.

    4.

    Electric air conditioner

    portable type

    13.To avoid electric shock, a damaged power cord must be replaced only by an authorized service center and qualified specialists.

    14.Prior to disposal of the device, it is necessary to remove batteries from it, after that they can be safely disposed.

    15.Connect the air conditioner only to 220-240 V 50 Hz mains. If necessary, ask your power suppliers to give characteristics of your mains.

    16.The appliance is not intended for use by children and persons with reduced physical, sensory or mental capabilities, or a lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by an individual responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

    IMPORTANT!

    Efficient cooling require to:

    1.Ensure at least 30 cm of free space on the filtering side of the unit

    (Fig. 1).

    2.It is forbidden to fold the hose!

    EN

    or

    Fig. 1

    Electric air conditioner

    5.

    portable type

    3.TECHNICAL CHARACTERISTICS

    Tab.1

    Model

    H-AP2-07C-UI002

    H-AP2-09C-UI003

    Capacity (cooling) kW

    2,05

    2,71

    Rated input (cooling) W

    810

    1030

    Voltage V/Hz

    220~240/50

    220~240/50

    Rated current (cooling) A

    3.5

    4.7

    Air circulation m3/h

    370/320

    370/320

    Capacity of draining (L/h)

    0.8

    1

    Noise level dB(A)

    55/52

    55/52

    Refrigerant

    R410A

    R410A

    Energy class (cooling)

    A

    A

    Electrical protection class

    I

    I

    Degree of protection against moisture

    IPX0

    IPX0

    Net weight (kg)

    22.5

    24.5

    Gross weight (kg)

    25

    28

    Net dimensions (mm)

    349x381x749

    349x381x749

    Packing dimensions (mm)

    392x542x780

    392x542x780

    EN

    NOTE:

    The manufacturer reserves the right to make changes in the design, scope of delivery, product manufacturing technology, as well as change its technical characteristics to improve its consumer and technical properties without prior notice.

    Scope of delivery

    1.Household air conditioner 1 pc.

    2.Remote control* (batteries are not supplied, 1,5V UM4 AAA CR03 batteries are required) 1pc.

    3.The adapter for air duct 1 pc.

    4.Air outlet hose 1 pc.

    5.Removable grille 1 pc.

    Hyundai H-AP2-07C-UI002, H-AP2-09C-UI003 User Manual

    6.

    1

    3

    2

    4

    10

    5

    8

    Fig. 2

    Fig. 3

    4. DEVICE DESCRIPTION (Fig. 2 and 3)

    1.

    Control panel

    2.

    Horizontal louver

    EN

    3.

    Handle

    4. Remote signal receptor

    5.

    Panel

    6. Air filter

    7.

    Air outlet grille

    8.

    Rollers

    9.

    Air inlet grille

    10. Condensation drain hole

    11. Air inlet grille

    12. Air filter

    13. Condensation drain hole

    Installation of air outlet hose (Fig. 4)

    1.Before using install the adapter on hose for air outlet (Fig. 4-2)

    2.Install hose for air outlet into the hole ( Fig. 4-3).

    Electric air conditioner portable type

    6

    9

    7

    12

    11

    13

    Fig. 4-1

    Fig. 4-2

    Fig. 4-3

    Electric air conditioner

    7.

    portable type

    5. CONTROL OF PORTABLE AIR CONDITIONER

    5

    3

    4

    2

    6

    1

    8

    7

    Fig. 5

    Control panel

    1.POWER button. Press this button to switch on or off the unit.

    2.MODE button. Press this button to select the mode of dehumidification or cooling.

    3.TEMP up button. In the cooling mode each press of this button raises, cooling and fan the set temperature by 1°C up to maximum 30°C.

    4.TEMP down button. In the cooling mode each press of this button lowers the set temperature by 1°C up to minimum 17°C.

    5.LED display. The appliance displays the set temperature and setting of the automatic timer. During operation in the drying/fan mode, the appliance displays the current indoor temperature.

    6.FAN speed button. Press this button to select low, high or automatic fan speed button. When the automatic speed is selected (in the cooling mode), high, medium or low speeds are selected automatically depending on the difference between the set temperature and the room temperature. In the automatic speed mode, all rotation speed indicators are extinguished.

    7.Programmable timer on/off button.

    ON timer. The ON timer is used to automatically switch on the unit upon expiration of the set time.

    Press the timer button when the unit is not operating to set the desired time (buttons 3 and 4).

    The unit will be automatically switched on when the set time expires.

    Press POWER button before the set time expires. Time setting will be canceled and the unit will be switched on.

    OFF timer. The OFF timer is used to automatically switch off the unit upon expiration of the set time.

    Press the timer button when the unit is operating to set the desired time (buttons 3 and 4).

    The unit will be automatically switched off when the set time expires.

    Press ON/OFF button before the set time expires. Time setting will be canceled and the unit will be switched off.

    8.SLEEP button. Press this button to increase (during cooling) or decrease (during heating) the set temperature by 1°C in 30 min after activation of this function. Temperature is increased

    (during cooling) or decreased (during heating) by 1°C in another 30 min. In 7 hours, the air conditioner will be automatically switched to the previous mode.

    EN

    8.

    Electric air conditioner

    portable type

    Note

    This function is not accessible in the fan/drying modes.

    When power supply is turned off, the sleep mode is automatically switched off.

    When the unit is turned off, settings of the sleep mode are automatically turned off.

    Indicators for operating mode:

    Cool — cooling mode indicator

    Dry — dry mode indicator

    Fan — fan mode indicator

    Auto — auto mode indicator

    Hight — hight speed fan indicator

    Low — low speed fan indicator

    REMOTE CONTROL

    1.Button «ON/OFF». Using this button, you may turn the conditioner on or off.

    2.Button «TEMP» (increase) for setting of the required air temperature from 17°С to 30°С.

    Using this button, you may set the required air temperature indoors.

    3. Button «Memory». Using this button you

    may restore the current settings or resume

    previous setting. Hold the button to save

    current settings. Press the button to load

    stored settings.

    4.

    Select-mode button «MODE». Using this but-

    ton, you may select a required mode: Auto,

    Cool, Dry, Fan.

    11 5.

    Button «SLEEP». Press this button to

    activate the sleep

    6.

    Button «SWING». Using this button, you may

    10

    regulate position of air-relief blinds and

    forward treated air to various directions.

    7. Button «DISPLAY». Using this button you 9 can may to clear the display on the indoor

    unit. Press it again to light the display of air conditioner.

    88. Button «TIMER OFF». Press this button to initiate the off-delay timer.

    9.Button «TIMER ON». Press this button to initiate the on-delay timer.

    10.Button «FAN». Using this button, you may select rotation speed of the indoor unit fan: «Auto»,

    «High», «Low».

    11.Button «TEMP» (decrease) for setting of the required air temperature from 17°С to 30°С.

    Using this

    button, you may set the required air temperature indoors.

    Fig. 6

    Electric air conditioner portable type

    Fig. 7

    9.

    NOTE:

    In dehumidification mode, remove the rubber plug of the drainage hose, install the respective drainage hose (not in the set). Disconnect the air outlet hose, connect the drainage hose to the drainage hole and drain water from the unit to ensure maximum dehumidification efficiency.

    To resume the operation, remove the rubber plug of the drainage hose to drain water at first. After water is drained, turn the unit on, the unit will resume operation

    EN

    6. MAINTENANCE

    IMPORTANT!

    Disconnect the unit from the mains prior to cleaning.

    1.When cleaning the air conditioner, do not use gasoline, solvents and other chemically active substances.

    2.To avoid electric shock and damage to electrical components, do not pour water on the air conditioner from a tap or a hose.

    3.Do not use the air conditioner if the power cord is damaged. On the subject of replacing a damaged power cord, contact an authorized service center.

    Air filter

    Air filter clogging with dust particles impairs the air conditioner operation efficiency, therefore clean the filter no less than once in two weeks.

    Filter removal/installation

    Remove the air filter in the direction, indicated by the arrow. Slightly push it and then take it out from the device for cleaning. (See Fig. 8).

    10.

    Electric air conditioner

    portable type

    Fig. 8

    Installation of the filter is performed in the reverse order.

    EN

    Filter cleaning

    At first, carefully clean the filters by means of vacuum cleaners. Then immerse the filter in warm water (about 40°C) with a soft detergent, wash it and dry it without exposure to direct sunlight.

    Air intakes (heat exchangers)

    Use a vacuum cleaner for cleaning.

    Case

    Wipe the surface by a damp cloth and dry it by a soft dry cloth.

    Automatic condensate removal

    Condensate is automatically removed from the unit. Moisture inside the unit starts to evaporate and is removed from the unit through an air duct (or an air diffuser) in the form of steam.

    7. SERVICE LIFE

    Service life of the unit is 10 years provided respective installation and operation rules are followed.

    Date of manufacture of the air conditioner is indicated on the unit in the serial number. Contact the seller for additional information.

    8. RULES OF DISPOSAL

    After service life is expired, the unit must be disposed in compliance with rules, regulations and methods effective at disposal stations.

    9. HELPFUL ADVICE

    Since the unit may heat when operated, do not install it in places with limited free space. In case of a dangerous current leakage, do not use the unit at high humidity.

    Keep the unit away from direct sunlight: its paint may fade.

    The unit has a function allowing it to be switched off automatically at a certain temperature, in this case let the unit cool down, after that it can be switched on again.

    Do not position the unit nearby objects that block air flow, for example, furniture or curtains since it has a great impact on operation of the unit.

    Keep the unit away from direct sunlight: it may cause overheating and shutdown of the unit.

    Electric air conditioner

    11.

    portable type

    ELECTRIC POWER SUPPLY

    Make sure characteristics of the mains correspond to characteristics of the unit.

    Insert the plug in the socket securely to avoid overheating and risk of fire. Do not pull the power cord with excessive force: it may damage it.

    IMPORTANT!

    At high humidity additional condensate removal will be required (P1 symbol will be shown on the display). In this case a condensate collection tank at the device’s base is used.

    In this case follow the instructions given below.

    When the condensate collection tank is filled up, water needs to be drained, otherwise the unit will not operate. Condensate should be drained by opening the lower plug at the device’s base (Fig. 9).

    But air conditioners are also designed to remove condensate continuously without a need for a regular moisture removal from the device. To do so it is necessary to use the drainage hose (not in the set) and perform the following procedure:

    1.Prepare the drainage hose for condensate removal;

    2.Remove the plug from the back side of the device;

    3.Insert the drainage hose into the condensate drainage hole;

    4.Take the hose out to the drainage system to remove condensate;

    A hole designed for continuous condensate removal in the center of the device (Fig. 9) can be used for continuous condensate removal under conditions of increased humidity inside a room.

    To do so it is also necessary to perform the abovementioned procedure.

    EN

    Fig. 9

    Electric air conditioner portable type

    Trouble

    Cause

    Troubleshooting method

    The air conditioner is not switched on when Power button is pressed

    Loud noise or strong vibration

    A noise, resembling a gurgle of water

    The tank fill-up indicator

    Drain water from the tray

    is flashing, the condensate

    collection tray is filled up

    The air conditioner is

    Install the air conditioner on a

    installed on an inclined or

    smooth horizontal surface

    unsmooth surface

    Noise emerges due to

    It is normal

    refrigerant flow in pipes

    Error codes for LED-display model

    EN

    E1

    Room temperature sensor

    Unplug the unitand plug it

    error

    back in. If error repeats, call

    for service

    E2

    Evaporator temperature

    Unplug the unitand plug it

    sensor error

    back in.

    If error repeats, call for

    service

    E3

    Display panel communica-

    Unplug the unitand plug it

    tion error

    back in.

    If error repeats, call for

    service

    Error codes for LED-display model

    P1

    Bottom tray is full

    Connect the drain hose and

    drain the collected water

    away. If error repeats, call for service

    NOTE:

    When more than one codes occur, the priority of the code display order is: E4-E2-E1-P1.

    Electric air conditioner portable type

    13.

    Such marking indicates that disposal of this product along with other domestic waste is forbidden in the EU. To prevent environmental or health damage as a result of uncontrolled waste disposal, please hand this product for recycling to enable rational use of material resources. To return the device you used, please use the collection and return system or contact the point of sale, where the device was purchased. They can take it for an environmentally safe disposal.

    EN

    14.

    Электрический кондиционер воздуха мобильного типа

    Содержание

    1.

    Важная информация

    14

    2.

    Меры предосторожности

    15

    3.

    Технические характеристики

    17

    4.

    Описание мобильного кондиционера

    18

    5.

    Управление мобильным кондиционером

    19

    6.

    Обслуживание

    21

    7.

    Срок эксплуатации

    22

    8.

    Правила утилизации

    22

    9.

    Полезные советы

    22

    10. Устранение неисправностей

    24

    11. Сертификация

    26

    RU

    Электрический кондиционер воздуха мобильного типа

    15.

    Уважаемый покупатель!

    Благодарим Вас за удачный выбор и приобретение электрического мобильного кондиционера воздуха Hyundai. Он прослужит Вам долго.

    1. ВАЖНАЯ ИНФОРМАЦИЯ

    1.Просим внимательно ознакомиться с инструкцией по эксплуатации перед установкой и использованием мобильного кондиционера воздуха.

    2.Во избежание повреждений кондиционера и аннулирования Вашей гарантии перед началом работы поставьте прибор в вертикальное положение (как изображено на обложке инструкции) минимум на 2 часа до эксплуатации.

    3.В тексте и цифровых обозначениях данной инструкции могут быть допущены опечатки.

    4.Если после прочтения инструкции у Вас останутся вопросы по работе и эксплуатации прибора, обратитесь к продавцу или в специализированный сервисный центр для получения разъяснений.

    5.На изделии присутствует этикетка, на которой указаны все необходимые технические данные и другая полезная информация о приборе.

    6.Используйте прибор только по назначению, указанному в данной инструкции.

    7.Перед установкой мобильного кондиционера, не подключая его к электросети, проверьте и убедитесь, что сетевая розетка для кондиционера имеет контакт заземления и правильно заземлена.

    8.При отсутствии заземляющего контура в вашей электросети эксплуатация мобильного

    кондиционера опасна для жизни.

    9.Не используйте переходники и удлинители для подключения вашего мобильного кондиционера.

    10.Неправильная установка и использование настоящего кондиционера может привести к серьезным травмам или ущербу для вашего имущества.

    11.Любые сервисные работы должны производиться специализированной организацией, квалифицированными специалистами.

    RU

    2. МЕРЫ ПРЕДОСТОРОЖНОСТИ

    1.Не закрывайте вентиляционные отверстия!

    2.Убедитесь, что входное и выходное вентиляционное отверстие свободно.

    3.Не засовывайте посторонние предметы в воздуховыпускные решетки кондиционера. Это очень опасно, т.к. вентилятор вращается с высокой скоростью.

    4.Устанавливайте устройство на горизонтальную поверхность во избежание утечки конденсата (воды).

    5.Не устанавливайте напольный кондиционер в следующих местах:

    в местах воздействия прямых солнечных лучей;

    вблизи источников открытого пламени;

    вблизи других работающих нагревательных приборов;

    в местах, где возможно попадание брызг воды или пара на прибор;

    в помещениях с повышенной влажностью;

    вблизи бассейнов, ванных и душевых комнат.

    6.Не используйте устройство во взрывоопасной или коррозионной среде. Не храните рядом с кондиционером бензин и другие летучие легковоспламеняющиеся жидкости – это очень опасно!

    7.Используйте устройство в режиме охлаждения для поддержания температуры в помещении 17-32°С.

    8.Периодически очищайте фильтры для обеспечения эффективной работы устройства.

    9.Для обеспечения надежной работы компрессора не наклоняйте кондиционер.

    10.Если устройство отключено, повторное включение должно осуществляться не ранее чем через 3,5 минуты во избежание выхода из строя компрессора.

    16.

    Электрический кондиционер воздуха мобильного типа

    11.Для работы компрессора необходим ток силой как минимум 10А. Во избежание перегрева и риска возникновения пожара, а также повреждения внутренней электрической сети, не включайте устройство в удлинители.

    12.Устройство предназначено для охлаждения и осушения воздуха только в домашних условиях и не может применяться в промышленных целях.

    13.Во избежание опасности поражения электрическим током, поврежденный силовой шнур должен заменяться только авторизованным сервисным центром изготовителя, квалифицированными специалистами.

    14.Перед утилизацией устройства необходимо извлечь батареи из пульта управления, после чего они подлежат безопасной утилизации.

    15.Подключайте кондиционер только к сети 220-240 В 50 Гц. При необходимости выясните характеристики своей сети у поставщиков электроэнергии.

    16.Устройство не предназначено для использования лицами (включая детей) с ограниченными физическими, сенсорными или умственными возможностями, обладающими недостаточным опытом и знаниями, если они не находятся под наблюдением и не получили инструкций по использованию устройства от лица, ответственного за их безопасность. Необходимо следить, чтобы дети не играли с устройством.

    ВНИМАНИЕ!

    RU

    Для эффективного охлаждения необходимо:

    1.Обеспечить свободное пространство не менее 30 см с фильтрующей стороны устройства. (рис.1).

    2.Запрещается перегибать шланг!

    Воздуховод может быть собран или удлинен согласно требованию по установке, но рекомендуется, чтобы воздуховод был собран до минимальной длины.

    или

    Рис. 1

    Loading…

    Понравилась статья? Поделить с друзьями:
  • Hyundai h 1505 инструкция к часам
  • Hyundai creta инструкция по эксплуатации купить
  • Hyundai creta инструкция по эксплуатации pdf
  • Hyundai allegro кондиционер инструкция по применению
  • Hytera рация инструкция по использованию