ICAD 600
Fig. 1
Fig. 3
Fig. 5a, ICM + ICAD 600
© Danfoss A/S (AC-SMC/MWA), 08-2011
Instruction
Actuator
ICAD 600 / ICAD 900 / ICAD 1200
ICAD 900
ICAD 1200
Note: When mounting the
ICAD make sure to push ICAD
down to mechanical stop.
2.5 mm
Nm
LB-feet
3
2.5
Fig. 5b, ICM + ICAD 900
DKRCI.PI.HV0.E6.02 / 520H3832
ICAD 600
ICAD 900
ICAD 1200
Fig. 2
Fig. 4
mm
in.
H
45
1.77
L
25
1
3
Fig. 5c, ICM + ICAD 1200
1
Related Manuals for Danfoss ICAD 600
Summary of Contents for Danfoss ICAD 600
- Manuals
- Brands
- Danfoss Manuals
- Control Unit
- Old ICAD 900 series
Manuals and User Guides for Danfoss Old ICAD 900 series. We have 5 Danfoss Old ICAD 900 series manuals available for free PDF download: Instruction, Installation, Programming, And Troubleshooting Manual, Quick Start Manual
Danfoss ICAD Series Installation Manual (2 pages) Document Information:
|
|
Pages Preview: |
-
Mitsubishi Electric
Central Controller G-50A
G-50AON/OFFCENTRAL CONTROLLERMitsubishi Electric Air-conditioner Network SystemCentral ControllerModel: G-50AInstallation ManualBefore using the controller, please read this Installation Manual carefully to ensure properoperation. Keep this manual for future reference.Contents1. Safety precautions to be observed wit …
Central Controller G-50A Controller, 12
-
Kelly
KBS48181E
Kelly KBS-E Brushless Motor Controller User’s Manual V 1.2Kelly KBS-E Brushless MotorController User’s ManualDevices Supported:Rev.1.2Dec.2016KBS48151EKBS72151EKBS48181EKBS72181EKBS48221EKBS72221E …
KBS48181E Controller, 26
-
CD Automation
Revo C 3PH
USER’S MANUAL Rev. 04/20193PHfrom 30A to 40A006M-RC3-30-40CD Automation S.r.l. Via Picasso, 34/36 — 20025 Legnano (MI)- Italy Tel. +39 0331 577479 — Fax +39 0331 579479E-mail: [email protected] — Web: www.cdautomation.com …
Revo C 3PH Controller, 64
-
Vitlab
maneus
VITLAB GmbHLinus-Pauling-Str.163762 GrossostheimGermanytel: +49 6026 97799-0fax: +49 6026 [email protected] de pipeteado / Pipette Controller maneus®Instrucciones de manejoOperating Manual …
maneus Laboratory Equipment, 36
-
ProMinent
DULCOMETER D1C
STARTSTOPDULCOMETERauto.: 33.2 °C0.95ppmFluorideOperating InstructionsDULCOMETER® D1CPart 2: Adjustment and Operation,Measured Variable FluoridePart No. 987306 ProMinent Dosiertechnik GmbH · 69123 Heidelberg · Germany BA DM 150 05/07 GBProMinent®D1C2-001 DPlease completely read through operating instructions! · …
DULCOMETER D1C Controller, 28
-
ModelCraft
550
Für die Montage der Adapterplatte wird zuerst der vorhandene Seilzugstarter vom Motor abgebaut.Anschließend ist die Adapterplatte mit den beiliegenden 4 Schrauben am Motor zu befestigen. Vorher istggf. der kleine beiliegende Kunststoff-Abstandshalter (abhängig vom Motor) in die Sechskant-Aufnahmeder Adapterplatte ei …
550 Controller, 4
Recommended Documentation:
Quick Start Guide Before you start using ICAD: Quick Start Guide ICAD 600A / ICAD 1200A 24 Volt d.c. ONLY 1 Oil 2 Terminal box not supplied by Danfoss Tighten CW Ref. 3 Colour Description A Black – Common Alarm B Brown – ICM fully open C Red – ICM fully closed D Orange – GND ground E Yellow + 0/4 - 20 mA Input F Green + 0/2-10V input or digital input for on/off control G Blue + 0/4 - 20 mA Output I Black + Fail safe supply Battery / UPS* 19 V d.c. II White + III Brown – Digital Ouput Supply voltage 24 V d.c. * Uninterruptable Power Supply 24 Volt d.c. ONLY Prefabricated ICAD cable length Code number Voltage ICAD terminal (600A/1200A) [V d.c.] Please observe cable voltage drop Distance between the applied d.c. transformer and the ICAD terminal box may cause a voltage drop. Cross section of cables and size of d.c. transformer must be calculated so that the voltage at all time at the ICAD terminal box*, both during standstill and during operation of ICAD, is within this range: Min. Max. 1.5 m 027H0426 21 3m 10 m 027H0438 027H0427 22 23 26.4 15 m 027H0435 24 * Do not measure inside the ICAD itself. © Danfoss | DCS (MWA) | 2016.09 DKRCI.PI.HV0.J4.02 / 520H4887 / 027R9801 1 Decrease value Edit / Enter Note: If the keypad is not operated within 20 seconds; time out will automatically exit programming mode. Programming the ICAD 4 Valve size setup (mandatory) When powering up the ICAD, A1 will flash in the display ; 01 Hold down for 2 seconds to enter programming mode. 0 ; 10 11 Press and go to parameter 10. Press Press until you reach 11 (password). Press 1: ICM 20 with ICAD 600A 2: ICM 25 with ICAD 600A 3: ICM 32 with ICAD 600A 4: ICM 40 with ICAD 1200A 5: ICM 50 with ICAD 1200A Valve label ID: ICM 20 ICM 25-65 ; 26 Press until you reach parameter 26 Press 6: ICM 65 with ICAD 1200A 7: ICM 100 with ICAD 1200A 8: ICM 125 with ICAD 1200A 9: ICM 150 with ICAD 1200A 10: CVE pilot with ICAD 1200A ; 26 CA ICM/CVE & ICAD is now calibrating. Hold down for 2 seconds to exit programming mode. ICM 100-150 Press or to select ICM size or CVE. Press 5 Changing analogue input signal (optional) ; 01 Increase value ; 03 2 Press until you reach parameter 03. Press Press or to select analogue input signal. ; 03 1: 0-20 mA 2: 4-20 mA* 3: 0-10 V 4: 2-10 V * default factory setting Hold down for 2 seconds to enter programming mode. ; 03 A3 Press Factory reset of ICAD Disconnect power Hold down for 2 seconds to exit programming mode. 24 Volt d.c. ONLY 2 If A3 alarm occurs the analogue input signal is out of range. For further functions, programming possibilities and factory settings; please see ICAD instruction. Press down and simultaneously while reconnecting power Release and Note: If factory reset has been performed the ICAD will start flashing A1 in the display. DKRCI.PI.HV0.J4.02 / 520H4887 / 027R9801 © Danfoss | DCS (MWA) | 2016.09
Was this manual useful for you?
Yes
No
Thank you for your participation!
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project