Kone monospace инструкция по эксплуатации

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

KONE MonoSpace®

Maintenance Instruction

DIAGNOSTIC GUIDE FOR STANDARD NOCABINET

(-) 2006-11-10

All rights reserved.

© 2006 KONE Corporation

AS-10.22.027

KONE MonoSpace®

MONOSPACE ELECTRIFICATION

This document is intended to be used by people who are familiar with elevator maintenance and

installation and have received appropriate training on methods and safety as specified by KONE

CONTENTS

1

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1

1.2

2

ENVIRONMENTAL ISSUES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3

SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1

3.2

3.3

4

TROUBLESHOOTING PROCESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

4.1

4.2

4.3

4.4

5

TOP-LEVEL CHECKLIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

A.1

A.2

A.3

A.4

A.5

A.6

A.7

© 2006 KONE Corporation

All rights reserved.

Disclosure prohibited

DISTRIBUTION ONLY FOR AUTHORISED PERSONS

How to use this instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Related documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

General safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Personal safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Maintenance method safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Safety measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Main Switch 220 is OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

LOP230/F3 OK Led is OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

LOPCB/+24V Led is OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

1 (54)

AS-10.22.027

(-) 2006-11-10

loading

Summary of Contents for Kone MonoSpace 2.1 Series

Меню сайта
  • Главная страница

  • Информация о сайте

  • Тех. библиотека

  • Серии тех.литературы

  • Схемы,мануалы (разн.)

  • Справочная лит-ра

  • Книги(компьютер)

  • Эл.программы

  • Статьи электротехника

  • Плакаты электротехника

  • Статьи электроника

  • Статьи Компьютер

  • Любимый софт

  • Тех.книги (лифты)

  • Документация (лифты)

  • Статьи (лифты)

  • Журналы

  • Журналы (ин.яз.)

  • Автолюбителям

  • Гостевая книга

  • Обмен ссылками

  • Доска объявлений

  • Написать Админу

Реклама

Все категории
Тех.книги
[908]

Тех.документация
[45]

Схемы,мануалы (разн.)
[12]

Справочная лит-ра
[134]

Программы
[60]

Тех.книги (лифты)
[58]

Журналы
[1266]

Любимый софт
[28]

Авто
[78]

Книги(компьютер)
[48]

Серии тех.лит-ры
[47]

Журналы (ин.яз.)
[1684]

Видео
  • Видео уроки эл.тех.
  • Видео уроки комп
  • Видео лифты
  • Фильмы,сериалы,мульты
  • Плакаты
  • Плакаты электротехника
  • Плакаты сварка
  • Плакаты лифты
  • Лифты,подъёмники
  • Фотоприколы
  • Визиты

    Твиттер

    Читать @elektromeh

    Facebook
    Читать канал

    Телеграм
    Читать канал

    В контакте
    Читать канал

    Главная » Тех.документация

    KONE MONOSPACE

    [
    · Скачать (28,3Mb)]
    [ · Скриншот]

    [ · Сообщить о нерабочей ссылке]
    02.05.2010, 19:18
    • 1
    • 2
    • 3
    • 4
    • 5

    Категория: Тех.документация
    | Теги: лифты

    Просмотров: 11608 | Загрузок: 3398

    | Рейтинг: 0.0/0



    Всего комментариев: 0

    Добавлять комментарии могут только зарегистрированные пользователи.

    [

    Регистрация

    |

    Вход

    ]

    Поиск

    Форма входа

    Онлайн
  • Карта Кыргызстана
  • Online Соловьёв LIVE
  • Online Russia Today
  • Онлайн Радио
  • Онлайн Игры
  • Видео
  • Облако тегов

    лифты справочник Эл.программы электроника электротехника трансформатор двигатель Графика УЗО Аудио электросварка пускатели Авто компьютер техника радио серия Ремонт Софт Электро плакаты Журналы газосварка электрик Микроконтроллеры 500 схем Светотехника Серия МРБ Серия БЭМ тех.книги электромеханика Журналы ин.яз. Мануалы

    Статистика


    Top.Mail.Ru





    Онлайн всего: 1

    Гостей: 1

    Пользователей: 0

    KONE MonoSpace®

    Maintenance Instruction

    B.1

    B.2

    C.1

    C.2

    C.3

    C.4

    D.1

    D.2

    D.3

    D.4

    D.5

    E.1

    E.2

    F.1

    F.2

    F.3

    F.4

    F.5

    G.1

    G.2

    APPENDIX H. DRIVE FAULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    H.1

    H.2

    H.3

    H.4

    H.5

    H.6

    APPROVALS AND VERSION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

    © 2006 KONE Corporation

    All rights reserved.

    Disclosure prohibited

    LCECPUnc/CPU running Led is not blinking or LCECPUnc/Change board Led is ON23

    Hoistway Comm OK Led is OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Car Comm OK Led is OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    V3F OK Led is OFF (F0026) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    Drive Fault F0105. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

    Drive Runs Badly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

    Drive Fault F0108. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

    Drive Fault F0102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

    Abnormal Drive Behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

    Drive LEDs behavior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

    2 (54)

    AS-10.22.027

    (-) 2006-11-10

    Table of Contents for Kone MonoSpace 2.1 Series:

    • AS-10.22.027 28 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited C.3 Hoistway Comm OK Led is OFF *After changing the FCB, the software upload is needed (menu 5 7 2) and then the power cut to enable roll call. Step Check Possible cause Action 1 Does fault code “14 xx” or “24 xx” appear (xx indicates the floor number). Is the FCB/Fail Led (red) ON at a floor indicated by fault log? LCEFCB soft

    • AS-10.22.027 30 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited NOTE! Side B does not cause the Car Comm. LED to go off. 3 LOPCB/Inspection Led is ON and F1101 appears (and elevator is not in inspection mode)? Proceed to Step 3a. a Move XM13 terminal plug to LCECPUnc XM13 and unplug XB18 from LCECCB: Is LOPCB/Inspection Led still O

    • AS-10.22.027 24 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX C. LON COMMUNICATION IS NOT WORKING C.1 +24V Car and Shaft OK Led is OFF Step Check Possible cause Action 1 Access the SEP and check if LCEREC/Car 24V Led (D14) is OFF? Probably a short circuit or overload in the car side. Proceed to Step 1a. a Turn the power OFF for a minute and then turn it back ON: The system does no

    • AS-10.22.027 22 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX B. LOPCB/CPU RUNNING LED IS NOT BLINKING AND “——“ IS ON DISPLAY B.1 LOPCB/RS232 switch is at right hand position Step Check Possible cause Action 1 LOPCB/RS232 switch is at right hand position? RS232 mode is set for computer. Turn the switch to left hand position.

    • AS-10.22.027 4 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 1.2 Related documents The following documents are related with maintenance of KONE Monospace ® 2.1 elevators: • AM-01.03.002 Take 5 — Electrical safety when working on elevators, escalators and autowalks • AS-01.01.004 Take Care, End user safety focal points in

    • AS-10.22.027 35 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 2 MCEN Led in V3F16L goes ON when the elevator is put to inspection mode and run button is pushed? Flat cable between LCECUPnc and LCE230 / LCEADO or flat cable between LCECPUnc and drive or LCEADO is defective. Replace the defective component. 3 LOPCB Main Contactor Led is OFF all the time? Defective flat cable between LCECUPnc and LCE230 /

    • AS-10.22.027 40 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited F.2 Open Door Command Led is ON all the time Step Check Possible cause Action 1 Open Door Command Led is ON all the time? Closing force limiter adjustment is not OK. LCECCB or AMD drive could be defective. Check the closing force limiter and photocell. Replace the defective component(s).

    • AS-10.22.027 50 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited *) NOTE! For other motor types and special versions apply field support. 3 If F0102 is still active, measure the voltage between LOPCB motor current test pins TP1 and TP2: Is the voltage over 0.5V when the elevator is not running? Defective V3F16L. NOTE! When elevator is not running th

    • AS-10.22.027 33 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited D.3 Shaft Door Contact Led is OFF (F0051) Step Check Possible cause Action 1 No 230VAC voltage at LOP230/XLH8 pin 3? Defective switch or contactor. At each floor: Check the cables and the landing door contacts. 2 230VAC voltage at XH2 pin 3 on LCE230 / LCEADO board when the elevator is in RDF mode and Inspection drive is not activated? Defective LCE230 / LCEADO, LCECPUnc

    • AS-10.22.027 3 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 1 INTRODUCTION This instruction describes troubleshooting guidelines for KONE Monospace ® 2.1 elevators which have been set-up according to the relevant AM-instructions. The instruction was made using software versions LCE™: 6.5.9 and drive: 0.75 to analyse the fault beh

    • AS-10.22.027 54 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited

    • AS-10.22.027 42 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited F.5 Close Force Limiter Led is ON all the time, Open Button and Photocell Leds are OFF and F0048 and F0077 fault codes are displayed Step Check Possible cause Action 1 Close Force Limiter Led is ON all the time, Open Button LED and Photocell LEDs OFF and F0048 and F0077 fault

    • AS-10.22.027 53 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPROVALS AND VERSION HISTORY Compiled by: Technical Editor Seppo Starck Checked by: SEB Maintenance Specialist Jukka Lindberg Product Change Manager Ari Jokivalli Approved by: SEB Maintainability Manager Seppo Valliovuo Translation approved by: Issue

    • AS-10.22.027 17 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 3 No 230VAC voltage at LCEREC/X3 pins 1-2? Defective transformer. Replace the transformer. Step Check / Symptom Possible cause Action P15000017.wmf

    Questions, Opinions and Exploitation Impressions:

    You can ask a question, express your opinion or share our experience of Kone MonoSpace 2.1 Series device using right now.

    [Page 1] Kone MonoSpace 2.1 Series

    AS-10.22.027 1 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited KONE MonoSpace®AS-10.22.027© 2006 KONE CorporationAll rights reserved.(-) 2006-11-10 DIAGNOSTIC GUIDE FO…

    [Page 2] Kone MonoSpace 2.1 Series

    AS-10.22.027 2 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX B. LOPCB/CPU RUNNING LED IS NOT BLINKING AND “——“ IS ON DISPLAY. . . . 22 B.1 LOPCB/RS232…

    [Page 3] Kone MonoSpace 2.1 Series

    AS-10.22.027 3 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 1 INTRODUCTION This instruction describes troubleshooting guidelines for KONE Monospace ® 2.1 elevators …

    [Page 4] Kone MonoSpace 2.1 Series

    AS-10.22.027 4 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 1.2 Related documents The following documents are related with maintenance of KONE Monospace ® 2.1 eleva…

    [Page 5] Kone MonoSpace 2.1 Series

    AS-10.22.027 5 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 3SAFETY 3.1 General safety precautions Safety precautions Note Follow your national lift codes and other s…

    [Page 6] Kone MonoSpace 2.1 Series

    AS-10.22.027 6 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 3.2 Personal safety Gloves, safety shoes, helmets, goggles, dust masks, ear defenders and harnesses are pr…

    [Page 7] Kone MonoSpace 2.1 Series

    AS-10.22.027 7 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited WARNING Inverter drives usually remain energised for about 5 minutes after the power has been disconnecte…

    [Page 8] Kone MonoSpace 2.1 Series

    AS-10.22.027 8 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 4 TROUBLESHOOTING PROCESS 4.1 Introduction to troubleshooting Generally, in a troubleshooting process it i…

    [Page 9] Kone MonoSpace 2.1 Series

    AS-10.22.027 9 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited The following safety measures must be carried out when the work is completed: 4.3 Basic rules preventing E…

    [Page 10] Kone MonoSpace 2.1 Series

    AS-10.22.027 10 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 5 TOP-LEVEL CHECKLIST NOTE! Use the fault code list together with this checklist (Global LCE Fault Codes:…

    [Page 11] Kone MonoSpace 2.1 Series

    AS-10.22.027 11 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited FDOORSDoor related Leds Not OK F.1 Close Door Command Led is OFF all the time? 39 F.2 Open Door Command…

    [Page 12] Kone MonoSpace 2.1 Series

    AS-10.22.027 12 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX A. MAIN SWITCH OR POWER LEDS ON LOP230 OR LOPCB ARE NOT OK A.1 Main Switch 220 is ON but main po…

    [Page 13] Kone MonoSpace 2.1 Series

    AS-10.22.027 13 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited A.2 Main Switch 220 is OFF Step Check Possible cause Action 1 After turning the main switch 220 ON, it s…

    [Page 14] Kone MonoSpace 2.1 Series

    AS-10.22.027 14 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited A.3 LOP230/F2 OK Led is OFF and F2 fuse is blown Step Check / Symptom Possible cause Action 1 Replace the…

    [Page 15] Kone MonoSpace 2.1 Series

    AS-10.22.027 15 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 2 F2 fuse seems to be OK but blows when the elevator tries to run? Proceed to Step 2a. a Check the brak…

    [Page 16] Kone MonoSpace 2.1 Series

    AS-10.22.027 16 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited A.4 LOP230/F2 OK Led is OFF but F2 fuse is OK Step Check / Symptom Possible cause Action 1 No 230VAC vol…

    [Page 17] Kone MonoSpace 2.1 Series

    AS-10.22.027 17 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 3 No 230VAC voltage at LCEREC/X3 pins 1-2? Defective transformer. Replace the transformer. Step Check …

    [Page 18] Kone MonoSpace 2.1 Series

    AS-10.22.027 18 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited A.5 LOP230/F3 OK Led is OFF Step Check Possible cause Action 1 F3 fuse is blown? 230VAC short circuit so…

    [Page 19] Kone MonoSpace 2.1 Series

    AS-10.22.027 19 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 3 No 230VAC voltage at LOP230/XLH1 pins 4-5 and no 230VAC voltage at LCEREC/X3 pins 3- 4 in the SEP p…

    [Page 20] Kone MonoSpace 2.1 Series

    AS-10.22.027 20 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited A.6 LOPCB/+24V Led is OFF Step Check Possible cause Action 1 Voltage at LOPCB/XL1 pins 1-2 is 18VDC-30VD…

    [Page 21] Kone MonoSpace 2.1 Series

    AS-10.22.027 21 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited A.7 LOPCB/+5V, LOPCB/+12V or LOPCB/-12V Led is OFF b Plug in XM16 and unplug XL1 connector: No 24VDC v…

    [Page 22] Kone MonoSpace 2.1 Series

    AS-10.22.027 22 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX B. LOPCB/CPU RUNNING LED IS NOT BLINKING AND “——“ IS ON DISPLAY B.1 LOPCB/RS232 switch i…

    [Page 23] Kone MonoSpace 2.1 Series

    AS-10.22.027 23 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited B.2 LCECPUnc/CPU running Led is not blinking or LCECPUnc/Change board Led is ON Step Check Possible cause…

    [Page 24] Kone MonoSpace 2.1 Series

    AS-10.22.027 24 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX C. LON COMMUNICATION IS NOT WORKING C.1 +24V Car and Shaft OK Led is OFF Step Check Possible cau…

    [Page 25] Kone MonoSpace 2.1 Series

    AS-10.22.027 25 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 2 LCEREC/Shaft 24V Led (D13) is OFF? Probably a short circuit or overload in the shaft side. Proceed to…

    [Page 26] Kone MonoSpace 2.1 Series

    AS-10.22.027 26 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited d Disconnect LCEFCB and LCEFOB one at the time. Does the fault disappear? NOTE! Multifuse on LCEREC n…

    [Page 27] Kone MonoSpace 2.1 Series

    AS-10.22.027 27 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited C.2 Both Hoistway Comm OK and Car Comm OK Leds are OFF Step Check Possible cause Action 1 Both Hoistway C…

    [Page 28] Kone MonoSpace 2.1 Series

    AS-10.22.027 28 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited C.3 Hoistway Comm OK Led is OFF *After changing the FCB, the software upload is needed (menu 5 7 2) and t…

    [Page 29] Kone MonoSpace 2.1 Series

    AS-10.22.027 29 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited C.4 Car Comm OK Led is OFF Step Check Possible cause Action 1 Check the fault codes: Does only one of the…

    [Page 30] Kone MonoSpace 2.1 Series

    AS-10.22.027 30 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited NOTE! Side B does not cause the Car Comm. LED to go off. 3 LOPCB/Inspection Led is ON and F1101 appears …

    [Page 31] Kone MonoSpace 2.1 Series

    AS-10.22.027 31 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX D. SAFETY CHAIN FAULTS WHEN ELEVATOR IS ABOUT TO START D.1 Safety Input Led is OFF when the elev…

    [Page 32] Kone MonoSpace 2.1 Series

    AS-10.22.027 32 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited D.2 Car Door Contact Led is OFF (F0044, F0023) Step Check Possible cause Action 1 Shaft Door Contact Led …

    [Page 33] Kone MonoSpace 2.1 Series

    AS-10.22.027 33 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited D.3 Shaft Door Contact Led is OFF (F0051) Step Check Possible cause Action 1 No 230VAC voltage at LOP230…

    [Page 34] Kone MonoSpace 2.1 Series

    AS-10.22.027 34 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited D.4 Main Contactor Led is OFF or blinking Step Check Possible cause Action 1 LOPCB Main Contactor Led is…

    [Page 35] Kone MonoSpace 2.1 Series

    AS-10.22.027 35 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 2 MCEN Led in V3F16L goes ON when the elevator is put to inspection mode and run button is pushed? Fla…

    [Page 36] Kone MonoSpace 2.1 Series

    AS-10.22.027 36 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited D.5 Start Permit Led is not OK (F0025) NOTE! When the elevator runs, the voltage is normally 0V and Start…

    [Page 37] Kone MonoSpace 2.1 Series

    AS-10.22.027 37 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX E. DRIVE RELATED LEDS NOT OK E.1 V3F OK Led is OFF (F0026) Hint: V3F OK Led OFF means that commu…

    [Page 38] Kone MonoSpace 2.1 Series

    AS-10.22.027 38 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited E.2 SPEED > 0,1m/s Led is not working or fault codes F0082, F0015 appear Step Check Possible cause Act…

    [Page 39] Kone MonoSpace 2.1 Series

    AS-10.22.027 39 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX F. DOOR RELATED LEDS NOT OK F.1 Close Door Command Led is OFF all the time Step Check Possible c…

    [Page 40] Kone MonoSpace 2.1 Series

    AS-10.22.027 40 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited F.2 Open Door Command Led is ON all the time Step Check Possible cause Action 1 Open Door Command Led is …

    [Page 41] Kone MonoSpace 2.1 Series

    AS-10.22.027 41 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited F.3 Photocell Led is ON or OFF all the time F.4 Door Open Button does not work? Step Check Possible cause…

    [Page 42] Kone MonoSpace 2.1 Series

    AS-10.22.027 42 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited F.5 Close Force Limiter Led is ON all the time, Open Button and Photocell Leds are OFF and F0048 and F007…

    [Page 43] Kone MonoSpace 2.1 Series

    AS-10.22.027 43 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX G. CAR POSITION RELATED LEDS NOT OK G.1 77:U, 77:N or 77:S not working (F0083, F0109, F0052, pos…

    [Page 44] Kone MonoSpace 2.1 Series

    AS-10.22.027 44 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited 5 The led/leds in LCECCB stays ON when XB27 is unplugged? Defective LCECCB. Replace the defective LCECC…

    [Page 45] Kone MonoSpace 2.1 Series

    AS-10.22.027 45 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited G.2 61:U, 61:N, 30 and B30 not working correctly (Fxxxx, position lost) Step Check Possible cause Action…

    [Page 46] Kone MonoSpace 2.1 Series

    AS-10.22.027 46 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPENDIX H. DRIVE FAULTS H.1 Drive Fault F0105 Step Check Possible cause Action 1 F0105 is continuously a…

    [Page 47] Kone MonoSpace 2.1 Series

    AS-10.22.027 47 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited H.2 Drive Runs Badly Step Check Possible cause Action 1 Use menu 4 11 to check the V3F software version …

    [Page 48] Kone MonoSpace 2.1 Series

    AS-10.22.027 48 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited H.3 Drive Fault F0108 Hint: 0108 means: Maximum difference between speed reference and measured speed exc…

    [Page 49] Kone MonoSpace 2.1 Series

    AS-10.22.027 49 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited H.4 Drive Fault F0102 Step Check Possible cause Action 1 F0102 (over current) during start? Go to Step 1…

    [Page 50] Kone MonoSpace 2.1 Series

    AS-10.22.027 50 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited *) NOTE! For other motor types and special versions apply field support. 3 If F0102 is still active, mea…

    [Page 51] Kone MonoSpace 2.1 Series

    AS-10.22.027 51 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited H.5 Abnormal Drive Behavior Step Check Possible cause Action 1 Drive internal relay K1 is heard switchin…

    [Page 52] Kone MonoSpace 2.1 Series

    AS-10.22.027 52 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited H.6 Drive LEDs behavior Step Check Possible cause Action 1 Led status on V3F16L: — MCEN Main contactor en…

    [Page 53] Kone MonoSpace 2.1 Series

    AS-10.22.027 53 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited APPROVALS AND VERSION HISTORY Compiled by: Technical Editor Seppo Starck Checked by: SEB Maintenance Spec…

    [Page 54] Kone MonoSpace 2.1 Series

    AS-10.22.027 54 (54) (-) 2006-11-10 KONE MonoSpace® Maintenance Instruction © 2006 KONE Corporation All rights reserved. Disclosure prohibited