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

Спасибо. Мы свяжемся с вами как можно скорее.

Language independent

Simple configuration via the backlit display

Input for external setpoint device

Optigo OP10 is a pre-programmed controller that can

be used for control of temperature in air handling and

heating applications. It is a stand-alone controller for

simpler applications. Optigo is extremely easy to install,

commission and control.

Optigo uses a display with an encoder knob, making

its built-in menu system very easy to use. Settings

are entered by turning the encoder knob to a desired

parameter/value. A value is then approved by pressing the

knob.

Models

The Optigo series comprises two different models, OP5U

and OP10.

OP5U has 5 in-/outputs and OP10 has 10 in-/outputs.

OP10 is available in two models:

• OP10 with 24 V AC supply voltage

• OP10-230 with 230 V AC supply voltage

Applications for OP10 and OP10-230

Optigo OP10 is pre-programmed with a choice of five

different control modes:

1. Supply air control

2. Supply air control with outdoor compensation

3. Cascaded room / extract air temperature control

4. Radiator circuit control

5. Domestic hot water control

Optigo OP10

OP10

Pre-programmed, configurable controller for

simple applications

The Optigo OP10 range of controllers controls

temperature. They are intended for DIN-rail mounting.

Pre-loaded with several application modes

24 V or 230 V AC supply voltage

Week-based clock / calendar function

Inputs and outputs

Optigo OP10 has:

• 2 analogue inputs, PT1000

• 1 SPI input for an external setpoint device

• 1 universal input, PT1000 or digital

• 2 digital inputs

• 3 digital outputs

• 2 analogue outputs, 0…10 V DC

Internal clock

Optigo OP10 has a built-in week-based real time clock

with a number of different scheduler alternatives.

Easy to install

Optigo is suitable for DIN-rail or cabinet mounting. Since

the terminals are detachable, all connections can be made

before Optigo is installed.

Optigo has been developed in accordance to our Ready-

Steady-Go concept, simplifying every step from installation to

management.

revision

06 2017

Display and encoder knob

All setting and configuration is performed using the

display and encoder knob on the front of the controller.

The menu information shown on the display is organised

in a tree fashion. By using the knob you can move in

between menus, set values etc.

In any of the configuration menus, pressing the encoder

knob will activate change mode. You can then turn the

knob to move between choices or set values. A second

press of the knob will accept the choice.

The menu system is divided into three levels:

• Base level: view mode

• The 3 second level: clock and scheduler program

• The 10 second level: configuration menus

Display information

The display can show the following information

Outdoor compensation

configured

Cascade control

Temperature control

Radiator circuit control

Domestic hot water control

Fan run indicator

2

Turn: move up/down in

the menus

Press: enter new menu

or accept new setting

Press for 3 seconds

for time menu,

or 10 seconds for

configuration menu.

Alarm indicator

Menu holds

Active 0…10V

changable values

input signal

or 3-position output

indicator

Optigo OP10

Display — Base level

This is an example of the display when in Base level view

mode. It is normally shown when there is no operator

activity.

The Base display shows current time and actual value.

There are bar-graphs showing the current output levels

together with symbols showing how the outputs have

been configured (Heating, Cooling or Damper etc).

There is also a symbol showing which of the five control

modes is configured, as well as an alarm symbol that is

displayed in the event of an alarm condition. The fan

symbol (control modes 1, 2 and 3 only) is lit as long as

the fan indication input is activated.

To see the values and status of all in- and outputs, simply

turn the knob counter-clockwise until the text I/O is

displayed and then press it. To return to the Base display,

click on the knob and then turn it clockwise.

Configuration level

Menu number

AO1 Graphic output signal

Control mode 1 only

Bargraph AO1 output level

Bargraph AO2 output level

AO2 Graphic output signal

Control mode 1 only