    No. IP8S-OM00009-B SMART POSITIONER (LEVER TYPE) PRODUCT NAME IP8001 Series MODEL/ Series…
  • Page 2: Table Of Contents

    Table of Contents Table of Contents Safety Instructions Introduction Specifications Parameter Settings List Workflow of IP8001 Positioner Setup Operating Principle Mounting Example of Mounting on Actuator Connection of Feedback Lever Feedback Lever Unit Body Cover Unit Piping Selecting OUT1/OUT2 Port Piping Piping of Double Acting Actuator Piping Layout…

  • Page 3
    Parameter Mode Functioning in Manual Mode Reflection of Changed Content in Parameter Mode Auto Mode Operation Auto Mode Display Switching Method at Auto Mode Manual Mode Operation Setting Parameters Parameter Code Parameter Code Detail How to Change Values Parameter Setting Procedure Parameter Setting Default Value List Operation Procedure Panel on PCB Cover Improved Controllability…
  • Page 4: Safety Instructions

    Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.

  • Page 5
    Safety Instructions Caution 1.The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
  • Page 6: Introduction

    Introduction IP8001 smart positioner is mounted on a pneumatic actuator to receive a 2-wire 4 to 20mADC input current from an adjusting meter (controller), to operate a pneumatic pilot valve and to control motion of the pneumatic actuator by electronic control feedback. Also, it has setting parameters which can optionally change the relation between the input current and actuator opening.

  • Page 7
    Table 2. Specifications of options Model Item IP8001-0*2 52-IP8001-0*4 Alarm output1, 2 Wiring method 2 wire system Corresponding standard DIN19234/NAMUR Standard Power supply voltage 10~28VDC 5~28VDC Load current 10~40mADC (Constant Current) ≧2.1mADC Signal status High (Not Active) R=350Ω±10% ≦1.2mADC Signal status Low (Active) 0.5mADC or less Response time 50msec or less…
  • Page 8: Parameter Settings List

    Parameter Settings List The IP8001 smart positioner operates at settings suitable for various applications by changing the setting parameters . Table 3 shows the main positioner functions which can be changed. For details of the setting parameters, refer to “■Parameter Code Detail”. Table 3 Mode Parameter…

  • Page 9: Workflow Of Ip8001 Positioner Setup

    Workflow of IP8001 Positioner Setup The workflow of IP8001 smart positioner from setup to initial adjustment is shown below. Follow this flow when performing setups and adjustments of the positioner. Start setup Check Check the specification and ensure the positioner is specifications suitable for the connected actuator and application.

  • Page 10: Operating Principle

    Operating Principle When the input current (4 to 20mADC) increases, the current which is applied to the coil of the torque motor (12) through the input, operation and output processing circuits (8) changes, causing the armature (13) to start rotating with the fulcrum of the leaf spring (11). Along with this, a gap is created between nozzle (6) and flapper (5), and nozzle back pressure decreases.

  • Page 11: Mounting

    Mounting Warning 1. Confirm the positioner is securely and firmly mounted onto the actuator. 2. Be careful not to get a finger caught when matching mounting positions. Caution 1. Be sure to keep the necessary space available for maintenance work (piping, wiring, adjustment, etc.) in your setup location.

  • Page 12: Connection Of Feedback Lever

    ■Connection of Feedback Lever Fig. 7 (1) Attach to the positioner that the valve stem and feedback lever form the right angle when the input current is 50% (distribute evenly with 50% input current set as the reference). (2) Attach to the positioner that the operation angle of feedback lever is within the range of 10 2: Do not impact on the feedback shaft of the positioner when the feedback lever connected with the valve stem or installed in the positioner.

  • Page 13: Piping

    Piping Warning Do not touch near the actuator axis when supplying air after piping. Caution 1. Perform sufficient pipe flushing and remove cutting chips, oil and dust from the piping to prevent foreign matter from entering the positioner. 2. When connecting an SMC fitting to an air connection port (SUP, OUT1, OUT2), apply a tightening torque of 12 to 14Nm.

  • Page 14: Piping Layout

    ■Piping Layout Table 7 No.IP8S-OM00009…

  • Page 15: Electrical Wiring

    Electrical Wiring Warning 1. Be sure to perform electrical wiring with the input current turned off. 2. Be sure to use a ground terminal and perform electrical construction following relevant local regulations. 3. Do not touch around the actuator axis when applying an input current after electrical wiring. 4.

  • Page 16: Electrical Wiring

    ■Electrical Wiring HART Input current communication terminal Terminal No. Power supply Load voltage A Power supply voltage Load Power supply voltage Load Fig. 10 Table 8 Terminal no. Description Electric wire diameter Remarks 2 4 to 20mA DC It corresponds to the 0.14~1.5mm Minimum input current of 3.85mA input current stranded wire and AWG26-14.

  • Page 17: Atex Intrinsic Safety Type Of Explosion Protected Construction

    ATEX Intrinsic Safety Type of Explosion Protected Construction Warning 1. A positioner must be energized only after wiring via a barrier. 2. Use a linear resistance type barrier based on intrinsically safe parameter for the input circuit. 3. If a positioner is used as intrinsic safety type of explosion protected construction for ATEX, connect it only to the intrinsically safety electric circuit with the following maximum value.

  • Page 18: Barrier

    Hazardous area Non-hazardous area Controller Positioner Input current Barrier Actuator Option output power supply Fig. 11 Cable gland M20×1.5 Input current Analog output Alarm output Grounding M4 screw for internal grounding terminal connection Terminal lug (uses twisted wire of 2.63~6.64mm Fig.

  • Page 19: Description Of Components

    Description of Components Fig. 13 shows a description of each component. Board cover HART terminal LCD display Input current terminal (Hold down together) Analog output Set button terminal Alarm output UP button terminal Ground terminal Torque motor DOWN button terminal Potentiometer terminal Mode button Fig.

  • Page 20: Initial Adjustment

    Initial Adjustment Warning 1. Pay attention to your surroundings when performing the initial adjustment because it causes the positioner to automatically move the actuator. 2. The positioner stroke reaches both ends during initial adjustment, so it cannot be used with an actuator that can be damaged by strokes to both ends.

  • Page 21: Check Angle Of Feedback Lever

    Procedure LCD display Select the parameter used in section 2 to 5 by pressing the UP or DOWN button ( ) and holding down the set button ( ) for + 1sec or longer. The angle of the feedback lever unit connected to the valve stem 2.

  • Page 22
    4: The positioner standard stroke is a rotational angle of 10 to 30 . An Installations condition with a rotating angle of less than 10 or over is not available. 5: A Description of pressure gauges mounted on the positioner are as shown in Fig.
  • Page 23: Simple Balance Current Adjustment

    3. Simple balance Adjust the torque motor balance current simply. current adjustment Procedure LCD display Press the UP or DOWN button ) in calibration mode to select zero adjust (0AdJ), and then hold down the set button ( + for 1sec. or longer. The LCD displays go (Go) for confirmation.

  • Page 24: Calibration

    4. Calibration Automatically perform zero point / span adjustment and PID constant. Procedure LCD display Press the UP or DOWN button ) in calibration mode to select calibration (CAL), and press and hold down the set button + ) for 1 sec. or longer. The LCD displays go (Go) for confirmation.

  • Page 25
    If good (Good) is not displayed during or after adjustment and the adjustment has not been completed successfully, perform readjustment in the following manner. <LCD displays high (HI) or low (Lo) > Procedure LCD display When the LCD displays high (HI) or (Lo), rotate balance…
  • Page 26
    If hunting occurs during step 3 (StP3) through step 5 (Stp5) and a check code (CHE0001 or CHE0003) is displayed, perform readjustment in the following manner. <When a check code 1 (CHE0001) is displayed> Procedure LCD display hunching occurs during adjustment, the PID constant is adjusted to automatically eliminate After hunting has been eliminated,…
  • Page 27: Input Current Calibration

    5. Input current calibration Normally, input current dose not need to be calibrated. If input values (S value) have a displacement in auto mode after the above adjustment, input current of 4 to 20mADC can be calibrated. Procedure LCD display Press the UP or DOWN button ) in calibration mode to select signal-zero (S-0).

  • Page 28: Mode Change On Lcd

    Mode Change on LCD ■Mode Change According to Fig. 19, press the mode button ( ), UP button ( ), DOWN button ( ) and set )to change operation mode. + button( ■Parameter Functioning in Manual Mode For the position indication (P value), zero / span setting (parameter code: 400) functions as it is. ■Reflection of Changed Content in Parameter Mode The changed content is reflected at the time when the mode moves from parameter to manual, and then moves to auto mode…

  • Page 29: Auto Mode Operation

    Auto Mode Operation ■Auto Mode Use an auto mode if controlling an actuator by an input current as a smart positioner. ■Display Switching Method at Auto Mode LCD display can be switched as follows according to Fig. 20 with the auto mode △…

  • Page 30: Setting Parameters

    Setting Parameters ■Parameter Code (1) When an input current is entered for the first time, only the parameter mode can be selected. According to “■Initial Adjustment”, calibrate the positioner. (2) After (1), the auto mode is displayed first when an input current is entered. (3) The parameter code is shown in Fig.

  • Page 31: Parameter Code Detail

    ■Parameter Code Detail (000) Actuator type Displays “linear (Lin)”. This parameter is fixed when shipped, and cannot be modified. “Direct (dir)” or “Reverse (rvS)” can be selected. The default (200) Operation direction when shipped is “direct (dir)”. setting 100% 200=dir 200=rvS 100% 100%…

  • Page 32
    The split range can be selected by setting ON or OFF. The default (300) Split range setting when shipped is OFF. If ON is selected, the lower limit (310) (input current range between 0.0 and 80.0%) and the upper limit (320) (input current range between 40.0 to 125.0%) can be set.
  • Page 33
    (400) Zero point / span setting Value setting (vALU), Ratio setting (rAtE)、 Operation setting (ACt), or No setting (oFF) of zero point / span can be set. The default when shipped is OFF. Value setting: The lower limit (411) (stroke range between -20.0 and 60.0%) and the upper limit (412) (stroke range between 40.0 to 120.0%) can be set.
  • Page 34
    Operation setting: Set lower and upper limit based on actuator operation position. Operate the same as manual mode, and P value becomes set value when it returned to upper directly by mode button. Ex-factory default values are (431) = 0.0 %, and (432) = 100.0 %. Lower limit (431) and upper limit (432) can be set only by conditions below.
  • Page 35
    (on) and (oFF) of forced fully-close / fully-open setting can be set (500) Forced fully-close/ independently for fully-close side and fully-open side. (on) is set fully-open setting for fully-close setting and fully-open setting for the default value at ex-factory. If ON is selected, the fully-closed setting (510) (input current range between 0.0 and 10.0%) and the fully-open setting (520) (input current range between 90.0 to 100.0%) can be set.
  • Page 36
    Valve opening characteristic can be selected from the following. (700) Valve opening (700) = Lin Linear characteristics setting (710) = EP25 Equal percentage 1:25 (R=25) Y=(R -0.04)×1/0.96 (720) = EP50 Equal percentage 1:50 (R=50) Y=(R -0.02)×1/0.98 (730) = qo25 Quick opening 25:1 (R=25) Y=(1-R )×1/0.96 (740) = qo50…
  • Page 37
    PID constant setting is available . Moreover, PID constant can (800) PID constant setting have simple adjustment with 21 steps. The simply adjusted PID constant will change against the detail setting in the rate shown on Table 12 . If more detail adjustment is necessary, calculate a PID constant for simple adjustment based on the ratio on Table 12 With the results, change a value of the detail setting.
  • Page 38
    Alarm 1 can be selected by setting ON or OFF. The default at (900) Alarm 1 setting shipping is OFF. In addition, an alarm can be selected from the following with ON selected. Lower limit alarm (Lo) (910) = Upper limit alarm (UP) The default value at shipping is the lower limit alarm (Lo).
  • Page 39
    Alarm output operation Alarm mode 0.5% fixed Upper alarm (UP) Position value Set value for alarm 100% 0.5% fixed Lower alarm (Lo) Position value Set value for alarm Fig. 31 “Proportional output (inC)” or “Reversed output (dEC)” can be (b00) Analog output setting selected.
  • Page 40
    The following can be performed: angle check for a feedback lever (C00) Calibration (AnGL), balance current adjustment (0AdJ), automatic calibration (CAL), input current adjustment (S-0) & (S-F), confirmation of balance current (bAL), span adjustment (SPn), and initialize of parameter (dFLt). (C10) Angle check Confirm rotation angle of the feedback lever.
  • Page 41
    (C70) Span adjustment Zero point / span for a positioner can be adjusted. PID constant will not be set unlike automatic calibration (parameter code: C30). This adjustment is useful when zero point / span needs to be adjusted again with the PID constant set before. (C80) Initialize Initialize (parameter code: C80) is used for mounting the positioner, which is mounted to the actuator and calibrated, to…
  • Page 42: How To Change Values

    ■How to Change Values Flashing Flashing The flashing digit can be changed. One-press on the mode button ( ) can △ button: to increase a value move the flashing digit to the next on the ▽ button: to decrease a value left.

  • Page 43: Parameter Setting Procedure

    ■Parameter Setting Procedure This parameter is fixed when shipped out of the factory. User can (000) Actuator type not change it. (200) Operation direction Customer can select direct (dir) or reverse (rvs). setting Procedure LCD display Hold down the set button ( +…

  • Page 44
    Procedure LCD display <Hereafter, only when (on) is set> For lower limit setting with (310), + hold down the set button ( for 1sec. or longer. After value starts flashing, change value within the range of 0.0 to 80.0%. After changing, hold down the mode button ( ) for 1sec.
  • Page 45
    Value setting (vALU), Ratio setting (rAtE), Operation setting (ACt), (400) Zero point / span setting or No setting (oFF) of zero point / span setting can be set. When selection setting is abled, (on) and (oFF) of zero point / span adjustment can be changed.
  • Page 46
    <(420) Ratio setting> Input all valve stroke which is used (incl. over travel), and select over travel setting side. Procedure LCD display + Hold down the set button ( for 1sec. or longer to move on to parameter change mode. Select Ratio setting (rAtE) or non zero point / span mode (oFF) by UP or DOWN button (…
  • Page 47
    <(430) Operation setting > Set stroke for 0% and 100% of input signal by operating the actuator. Procedure LCD display Hold down the set button ( + for 1sec. or longer to move on to parameter change mode. Select Operation setting (Act) or non zero point / span mode (oFF) by UP or DOWN button ( To select Operation setting (Act) ,…
  • Page 48
    Mode button Set button ) ≧1s ) ≧1s + ( ( Mode button Set button ≧1s ≧1s ( ) ( ) + Fig. 37-1 Mode button Set button ) ≧1s ) ≧1s + ( ( Mode button Set button Mode button Set button ≧1s )…
  • Page 49
    Mode button Set button ≧1s ) ≧1s + ( ( ) Mode button Mode button Set button Set button ≧1s ≧1s ≧1s ≧1s ( ) ( ) ( ) ( ) + + Set button ≧1s ( ) + Set button Set button ≧1s ≧1s…
  • Page 50
    Procedure LCD display Press UP or DOWN button ( to set upper value within 90.0 to 100.0% by (520) as lower value setting of clause 4. Hold down the mode button ( ) for 1sec. or longer for 2 times with some interval. Hold down the mode button ( again for 1sec.
  • Page 51
    (600) Dead band setting Set dead band (d-b). Procedure LCD display + Hold down the set button ( 1sec. longer start parameter change mode. + Hold down the set button ( for 1sec. or longer. After values start flashing, change the value within the range of 0.0 to 10.0%.
  • Page 52
    <(750) User value setting> Set line of 11 points curves defined by user by inputting values. Procedure LCD display + Hold down the set button ( 1sec. longer start parameter change mode. Select user (USEr) with the DOWN or UP button ( ), and hold +…
  • Page 53
    <(760) User operation setting> Line of 11 points curves defined by customer is set by operating actuator position. Procedure LCD display + Hold down the set button ( 1sec. longer start parameter change mode. Select (USEr) with the UP or DOWN button ( ) and hold down the set button (…
  • Page 54
    Set button ) ≧1s + ( Select linearity Mode button ) ≧1s ( Select equal percentage 1:25 Select equal percentage 1:50 Select quick opening 1:25 Select quick opening 1:50 User Mode button Set button ) ≧1s ) ≧1s + ( (…
  • Page 55
    Set button Set button ) ≧1s ) ≧1s + ( + ( 0% position setting (%) Mode button Mode button ) ≧1s ) ≧1s ( ( 10% position setting (%) 20% position setting (%) 30% position setting (%) 40% position setting (%) 50% position setting (%)
  • Page 56
    Mode button Set button ≧1s ≧1s ( ) ( ) + Set button ≧1s ( ) + Mode button ≧1s 0% position 0% input value (%) ( ) setting (%) 10% position 10% input value (%) setting (%) 20% position 20% input value (%) setting (%) 30% input value (%)
  • Page 57
    (800) PID constant setting PID constant setting is possible. Direct direction (Dir) and reverse direction (ruS) are settable individually. Easy adjusting is also possible. For adjustment, see “■Improved Controllability”. <(810/820) PID constant of Although PID constant is automatically adjusted during span adjustment, direct direction (Dir) and reverse direction (ruS) are detail setting>…
  • Page 58
    <(830) Easy adjustment Possible to change PID constant. Setting has to be zero if adjustment of PID constant> is not necessary. Procedure LCD display Hold down the set button ( + 1sec. longer start parameter change mode. Select easy (EASy) by UP or DOWN button.
  • Page 59
    F Mode button Set button ≧1s ≧1s ( ) ( ) + Mode button Set button ≧1s ≧1s ( ) ( ) + P constant I constant D constant Fig. 41-2 G Mode button Set button ≧1s ≧1s ( ) (…
  • Page 60
    Possible to select set alarm 1 mode (on), non-alarm mode (oFF), and (900) Alarm 1 setting change the set value if alarm 1 mode is selected. Procedure LCD display Hold down the set button ( + 1sec. longer start parameter change mode. Select alarm mode…
  • Page 61
    Mode button Set button ≧1s ≧1s ( ) ( ) + Mode button Set button ≧1s ≧1s ( ) ( ) + Mode button Mode button Set button Set button ≧1s ≧1s ≧1s ≧1s ( ) ( ) ( ) (…
  • Page 62
    Possible to select set alarm 2 mode(on), non-alarm mode(oFF), and (A00) Alarm 2 setting change the set value if alarm 2 mode is selected. Procedure LCD display Hold down the set button ( + 1sec. longer start parameter change mode. Select alarm mode…
  • Page 63
    Mode button Set button ≧1s ≧1s ( ) ( ) + Mode button Set button ≧1s ≧1s ( ) ( ) + Mode button Mode button Set button Set button ≧1s ≧1s ≧1s ≧1s ( ) ( ) ( ) (…
  • Page 64
    Possible to select analog output proportional output (inC) and (b00) Analog output setting reversed output (dEC). Procedure LCD display Hold down the set button ( + 1sec. longer start parameter change mode. Select proportional output (inC) or reversed output (dEC) by UP or ).
  • Page 65
    4mADC and 20mADC of input current can be calibrated. This is not <(C40/C50) Input current necessary usually. calibration > 25: For adjustment procedure, see “5. Input current calibration” of “■Initial Adjustment”. <(C60) Balance current Check the torque motor balance current adjustment condition. adjustment is good (Good), balance current is correctly adjusted.
  • Page 66
    < (C70) Span adjustment > Adjust zero point / span. Unlike automatic calibration of (C30), PID constant automatic setting is not performed. PID set once remains valid. This function is used when only zero-span adjustment is necessary. Procedure LCD display Press the UP or DOWN button ) in calibration mode to select span adjustment (SPn), and…
  • Page 67
    <(C80) Initialize > All parameters returns to ex-factory status. After initialization, (not CAL) is effective. Perform “■Initial Adjustment” before using positioner. Procedure LCD display Press the UP or DOWN button ) in calibration mode to select Initialize (dFLt), and hold +…
  • Page 68
    Set button ≧1s ( ) + Set button Check angel of ≧1s ( ) + feedback lever Mode button ≧1s ( ) Mode button ≧1s ( ) Simple balance current adjustment Span adjustment + PID adjustment Input current Calibration (4mADC) Input current Calibration (20mADC)
  • Page 69
    Mode button Set button ≧1s ≧1s ( ) ( ) + Set button ≧1s ( ) + After balance Current adjustment Set button ≧1s ( ) + Button operation See fig. 43-5 Being adjusted for details Balance current Hunching Hunching Operation failed readjustment occurred…
  • Page 70
    Balance current readjustment 2sec. later Button operation Set button Set button ≧1s ≧1s ( ) ( ) + + Return step3 Forced escape to re-adjust (Adjustment not completed) Fig. 45-5 Automatic PID constant reduction Same STEP is executed again Hunting not Hunting converged converged…
  • Page 71
    Automatic PID constant reduction Hunting not Hunting converged converged Set button ≧1s ( ) Balance current Button + readjustment operation 2sec. later Forced escape Set button Set button Set button (Adjustment ≧1s ≧1s ≧1s ( ) ( ) ( ) +…
  • Page 72
    Mode button Set button ≧1s ≧1s ( ) ( ) + Readjustment necessary Set button Normal end ≧1s ( ) + Set button ≧1s ( ) + Error Fig. 45-9 Mode button Set button ≧1s ≧1s ( ) ( ) +…
  • Page 73
    Mode button Set button ≧1s ≧1s ( ) ( ) + Mode button Set button ≧1s ≧1s ( ) ( ) + Set button ≧1s ( ) + Initialize completed Fig. 45-12 No.IP8S-OM00009…
  • Page 74: Parameter Setting Default Value List

    ■Parameter Setting Default Value List Table 14 shows parameter default value at ex-factory. See table below to return some parameters to default value after repeating setting and change. All parameters can be returned to default value by performing Initialize (C80). After initialize (C80), initial adjustment is necessary. Table14 Parameter Set items…

  • Page 75: Operation Procedure Panel On Pcb Cover

    ■Operation Procedure Panel on PCB Cover As Fig. 46 shows, on PCB cover, the operation flow from “000 Actuator type” to “C00 Calibration” is described in simplified form for customer’s reference. For details of each parameter setting, see “■Parameter Code Detail” in this operation manual.

  • Page 76: Maintenance And Check

    Maintenance and Check Warning ① After installation, repair and disassembling, connect compressed air and perform a proper function test and leak test. If bleed noise is louder than the initial state or operation is abnormal, stop operation and check if installation is proper or not. Modification of electrical construction is prohibited due to maintaining Explosion-Protected construction function.

  • Page 77: Caution On Handling

    Caution on Handling ■Operation Warning ① If the system is supposed to be in danger because of failure of the positioner, prepare the system with a safety circuit to avoid danger. ② Do not place electrical wiring in hazardous places while energized. Caution ①…

  • Page 78: Handling

    ■Handling Caution ① Avoid giving impact to the body and torque motor of positioner, and giving excessive force to armature because it leads to failure. Handle with care during transport and operation. ② When the positioner is used in places subject to vibrations, it is recommended that a tie wrap be used to prevent the lead wires from breaking.

  • Page 79: Troubleshooting, Error Code And Check Code

    Troubleshooting, Error Code and Check Code ■Troubleshooting If the positioner malfunctions, take countermeasures in accordance with the troubleshooting measures listed in Table 16. Table 16 Reference Error Possible cause Countermeasure page — Input current is disconnected. -Check that wires are connected to No LCD display 14,15 the positioner.

  • Page 80
    Error Possible cause Countermeasure Reference page — Input current resolution is faulty. — Check the input current system. Low sensing -Actuator’s sliding resistance is -Reduce the sliding resistance to as large. little as possible. -Operate only the actuator and check the stick-slip movement.
  • Page 81: Error Code List

    ■Error Code List Table 17 shows errors detected while the positioner is being adjusted. When errors are detected during adjustment, adjust the settings again in accordance with the countermeasure. Once an error has been detected, it is possible to reset it to the mode before the detection with the +…

  • Page 82
    Error No. Error Possible cause Countermeasure Failed adjustment of The balance current has not been -Adjust the balance adjusting screw balance current adjusted to be good (Good), but to correct the balance current (See 0003 the positioner has been set after Fig.
  • Page 83: Check Code List

    ■Check Code List Check code could be detected during calibration or parameter setting of the positioner. Table 18 shows check code which is indicated. When check code is detected, see adjustment method. Press set button ( + ) to return from check code. Table 18 Check Check point…

  • Page 84: How To Order

    How to Order For ATEX (preparing) Construction ATEX Temp. class Intrinsically safe explosion-protected ATEX Category1 (ATEX)+output function +HART communication function T5/T6 52-IP8001-0 * 4- * -*- * For CE marking IP8001-0 * *- * -*- * For CE marking Connection Type Smart positioner Electric…

  • Page 85: Drawing

    Drawing No.IP8S-OM00009…

  • Page 86
    No.IP8S-OM00009…
  • Page 87
    No.IP8S-OM00009…
  • Page 88
    No.IP8S-OM00009…
  • Page 89
    Revision history A 10/07/2020 “Compressed Air Cleaning Equipment” was deleted + Add the “Electric wire diameter” Change of ”Approval No.” B 25/12/2020 Change of Page21. 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.






Необходимо выбрать хотя бы один продукт
Barcode Scanner

  1. Главная
  2. Продукция
  3. Руководства и стандарты
  4. Руководства по эксплуатации

Руководства по эксплуатации

Пришло время применить на практике наши решения для вас

Здесь вы найдете подробные руководства, содержащие всю информацию, которая вам потребуется: сборка, инструкции по установке и техническому обслуживанию, условия эксплуатации, номинальные параметры, запасные части, меры предосторожности и пр.

Скачайте нужное вам руководство.

Обратите внимание! Некоторые браузеры (например, Chrome) могут блокировать скачивание. В таком случае можно сделать следующее: кликните правой кнопкой мыши на нужную ссылку и выберите «Сохранить ссылку как…», выберите папку на вашем компьютере, куда вы хотите сохранить файл и нажмите «Сохранить». В появившемся предупреждении нужно выбрать «Сохранить». Или воспользуйтесь другим браузером.

Серия Модель Описание Документ
AC-A AC-A Устройство подготовки сжатого воздуха модульного монтажа Скачать файл
AD AD402 Устройство автоматического отвода конденсата Скачать файл
AD AD600 Устройство автоматического отвода конденсата Скачать файл
AD EAD202-600 Устройство автоматического отвода конденсата Скачать файл
AF AF10-60 Фильтр Скачать файл
AF-A AF10-A / AF20-A / AF30-A / AF40-A / AF50-A / AF60-A Фильтр Скачать файл
AF AF800 — 900 Фильтр с высокой пропускной способностью Скачать файл
AF AF**-X425 Фильтр Скачать файл
AF AF-X430, AF-X440 Фильтр Скачать файл
AF EAF Фильтр Скачать файл
AFD AFD20-40 Субмикрофильтр Скачать файл
AFF, AM, AMD AFF70D, AFF80D, AFF90D, AM70D, AM80D, AM90D, AMD70D, AMD80D, AMD90D Магистральный фильтр, Микрофильтр, Субмикрофильтр Скачать файл
AFF AFF2C, 4C, 8C, 11C, 22C, 37B, 75B Магистральный фильтр Скачать файл
AFF AFF450 Магистральный фильтр с высокой пропускной способностью Скачать файл
AFF AFF4B Фильтр Скачать файл
AFF AFF75A — AFF450 Магистральный фильтр Скачать файл
AFF8B AFF8B Фильтр Скачать файл
AFM AFM20-40 Микрофильтр Скачать файл
AL-A AL-A Маслораспылитель Скачать файл
AL800/900 AL800/900 Маслораспылитель с высокой пропускной способностью Скачать файл
ALF800 – 900. ALF800-900 Маслораспылитель с автоматическим подводом масла Скачать файл
AL430 EAL430 Маслораспылитель Скачать файл
ALB ALB900 Центральный маслораспылитель Скачать файл
ALD EALD(U)600/900 Система для смазки масляным туманом Скачать файл
ALIP ALIP/ALIM Импульсный дозатор смазки Скачать файл
AM AM Микрофильтр Скачать файл
AFF, AM, AMD AFF70D, AFF80D, AFF90D, AM70D, AM80D, AM90D, AMD70D, AMD80D, AMD90D Магистральный фильтр, Микрофильтр, Субмикрофильтр Скачать файл
AMD AMD Субмикрофильтр Скачать файл
AME AME Фильтр сверхтонкой очистки Скачать файл
AMF AMF Фильтр-запахопоглотитель Скачать файл
AMG AMG Водоотделитель Скачать файл
AMH AMH Субмикрофильтр с предфильтром Скачать файл
AMJ AMJ Фильтр-влагоотделитель для вакуума Скачать файл
AMR AMR Микрофильтр-регулятор Скачать файл
AN AN, ANA1, ANB1, 25 Пневмоглушитель Скачать файл
AR AR Регулятор давления Скачать файл
AR EAR425-935 Регулятор давления с высокой пропускной способностью Скачать файл
AR-B AR-B-X2023 Регулятор давления Скачать файл
AR-B AR-B-X425 Регулятор давления Скачать файл
AR-B AR-B-X430, AR-B-X440 Регулятор давления Скачать файл
AR AR20/25/30/40/50/60-X2400 Обезжиренный регулятор давления Скачать файл
AR AR25, 30, 40, 40-06, 50, 60-X430, AR25, 30, 40, 40-06, 50, 60-X440 Регулятор давления Скачать файл
ARG ARG, AWG, ACG Регулятор давления, Фильтр-регулятор-маслораспылитель со встроенным манометром Скачать файл
AS AS1000 / AS2000 / AS3000 / AS4000 / AS5000 Пневмодроссель с обратным клапаном Скачать файл
AS AS1200-4200 Пневмодроссель с обратным клапаном Скачать файл
AS AS3000 — X422 Пневмодроссель с обратным клапаном Скачать файл
AVL AVL2000~5000 Устройство плавной подачи воздуха (аварийная деаэрация) Скачать файл
AW AW10~60 Фильтр-регулятор Скачать файл
AW AW20-F02-2-X2257 Фильтр/регулятор Скачать файл
AW AW20-N02-2-X2257 Фильтр/регулятор Скачать файл
AW AW20-Z00673-N02-2-X2257 Фильтр/регулятор Скачать файл
AW AW20-X2282 Фильтр/регулятор Скачать файл
AW AW30-*-X2622(*), AW40-*-X2622(*) Фильтр/регулятор Скачать файл
AW AW30-X2220 Фильтр/регулятор Скачать файл
AW AW30-Z00673-X2220 Фильтр/регулятор Скачать файл
AW AW40-X2515 Фильтр/регулятор Скачать файл
AW AW-X430, AW-X440 Фильтр/регулятор Скачать файл
AW-B AW-B Фильтр-регулятор Скачать файл
AW-B AW20-B-X2257 Фильтр-регулятор Скачать файл
AW-B AW30-B-X2330 Фильтр-регулятор Скачать файл
AW-B AW-B-X430, AW-B-X440 Фильтр-регулятор Скачать файл
C96 С96S*32, C96S*125 Пневматический цилиндр по ISO Скачать файл
C96 C96 Пневматический цилиндр Скачать файл
CA2 СА2*H Пневмогидравлический цилиндр Скачать файл
CKZ3 CKZ3T Пневмоцилиндр зажимной Скачать файл
CKZT CKZT40-135-DCJ2144J, CKZT80-135-DCJ2147J Зажимной пневмоцилиндр с регулировкой угла раскрытия Скачать файл
CKZT CKZT40-*-DCK9412K,9423K … CKZT60-*-DCK9416K,9417K Зажимной пневмоцилиндр
с ручным зажимом
Скачать файл
CLS CLS Пневмоцилиндр с блокировкой Скачать файл
CP96 CP96*-*C Пневматический цилиндр по ISO Скачать файл
CQ2 С(D)Q2*12 ~ С(D)Q2*100-Z Компактный пневмоцилиндр Скачать файл
CRA1-Z С(D)RA1*-Z Поворотный привод Скачать файл
CRB-Z CRB-Z Поворотный привод Скачать файл
CS1 CS1 Пневматический цилиндр Скачать файл
CS1 CS1 Пневматический цилиндр Скачать файл
CS2 CS2 Пневматический цилиндр Скачать файл
CY1 CY1S Бесштоковый магнитный цилиндр Скачать файл
D-MP□ D-MP□ Датчик положения Скачать файл
E-MY2 E-MY2 Линейный электрический привод Скачать файл
E-MY2 E-MY2 Линейный электрический привод Скачать файл
EX260 Ethernet/IPTM EX260 Компактный интерфейсный модуль Скачать файл
EX260 Ethernet/IPTM EX260 Компактный интерфейсный модуль Скачать файл
EX600 EX600-SEN1-X14 Промышленная сеть Fieldbus, Интерфейсный модуль Modbus/TCP Скачать файл
EX600 EX600-SDN1 EX600-SDN2 Интерфейсный модуль DeviceNet Скачать файл
EX600 EX600-SEN1-X3 Интерфейсный модуль EtherNet/IP Скачать файл
FGA FGA Промышленный фильтр Скачать файл
FGE FGE(S), FGE(L) Промышленный фильтр для средних расходов Скачать файл
FGD FGD Промышленный фильтр для малых расходов Скачать файл
FGF FGFC, FGFS, FGFR, FGFL Промышленный рукавный фильтр Скачать файл
FGF FGFS1A-20-E***, FGFS1B-20-E***, FGFL1A-20-E***, FGFL1B-20-E*** Промышленный рукавный фильтр Скачать файл
FN4 FN4102N 20-S0**(G), FN4102V 20-S0**(G) Промышленный фильтр Скачать файл
FQ1 FQ1 Промышленный фильтр Скачать файл
FH FH100 Фильтр возвратной магистрали Скачать файл
G43 G43 Манометр общего назначения Скачать файл
G36, G46 G36, G46 Манометр общего назначения Скачать файл
G46 G46 Манометр со встроенным реле давления Скачать файл
GS40 GS40 Миниатюрный датчик давления Скачать файл
HAW HAW Охладитель водяного типа Скачать файл
HEB-C HEBC002-C Прецизионный термостабилизированный резервуар Скачать файл
HEC HEC006 Термоэлектрический регулятор Скачать файл
HECR HECR-A Термостабилизатор с воздушным охлаждением для монтажа в стойку Скачать файл
HECR HECR002/004/006/008/010-A Встраиваемый термоэлектрический стабилизатор температуры Скачать файл
HECR-W HECR008-W / HECR012-W Термостабилизатор с водяным охлаждением для монтажа в стойку Скачать файл
H, DL, L, LL H, DL, L, LL Самоцентрирующиеся соединения с накидной гайкой Скачать файл
HRGC HRGC Стабилизатор температуры рефрижераторного типа Скачать файл
HRL HRL100-А* -40
HRL200-А* -40
HRL300-А* -40
Двухканальный термостабилизатор рефрижераторного типа Скачать файл
HRS HRS0**-AF-20-(BGJMT), HRS0**-WF-20-(BJM) Стабилизатор температуры рефрижераторного типа Скачать файл
HRS HRS060 Термостабилизатор рефрижераторного типа Скачать файл
HRS HRS090 Стабилизатор температуры рефрижераторного типа Скачать файл
HRS HRS100-A∗-20-∗, HRS100-W∗-20-∗, HRS150-A∗-40-∗, HRS150-A∗-40-∗ Стабилизатор температуры рефрижераторного типа Скачать файл
HRS HRS-DI003 Комплект для поддержания и контроля сопротивления деионизированной воды Скачать файл
HRS HRS-DI007 Комплект для поддержания и контроля сопротивления деионизированной воды Скачать файл
HRSH HRSH100-A∗-20-∗, HRSH250-W∗-20-∗S∗ Стабилизатор температуры рефрижераторного типа Скачать файл
HRSH HRSH090-A∗-20-∗, HRSH090-W∗-40-∗ Стабилизатор температуры рефрижераторного типа Скачать файл
HRZ HRZ001-L, HRZ010-W2S Термостабилизатор рефрижераторного типа Скачать файл
ID ID Осушитель адсорбционного типа Скачать файл
  IDF120D-3, IDF150D-3, IDF190D-3 Осушитель рефрижераторного типа Скачать файл
IDF IDF*С Осушитель рефрижераторного типа Скачать файл
IDF IDF240D-3 Осушитель рефрижераторного типа Скачать файл
IDF IDF370D-9* Осушитель рефрижераторного типа Скачать файл
IDFA IDFA60-23-A,C,L,R,T,V … IDFA90-23- A,C,L,R,T,V Осушитель рефрижераторного типа Скачать файл
IDFA IDFA3E-23, IDFA15E1-23-(K) Осушитель рефрижераторного типа Скачать файл
IDFA IDFA100F-38-C, K, R, V … IDFA150F-40-C, K, R, V Осушитель рефрижераторного типа Скачать файл
IDFA IDFA22E-23-C,K,L,R,T,V … IDFA75E-23-C,L,R,T,V Осушитель рефрижераторного типа Скачать файл
IDG IDG1 Мембранный осушитель воздуха Скачать файл
IDG IDG10 / IDG10H, IDG20M / IDG20HM Мембранный осушитель воздуха Скачать файл
IDG IDG30 / IDG30H / IDG30L, IDG50V / IDG50HV / IDG50LV Мембранный осушитель воздуха Скачать файл
IDG IDG3 / IDG3H, IDG5V / IDG5HV Мембранный осушитель воздуха Скачать файл
IDG IDG60-100 Мембранный осушитель воздуха Скачать файл
IDG IDG60 / IDG60H, IDG100V / IDG100HV Мембранный осушитель воздуха Скачать файл
IFW5 IFW5 Реле расхода диафрагменного типа Скачать файл
IL100 EIL100 Усилитель пневматического сигнала Скачать файл
IL100 IL100-F02-L-DIT00380 Низкотемпературный усилитель пневматического сигнала Скачать файл
IL100 IL100-(F, N)02-L-DIO00047, IL100-(F, N)03-L-DIO00047 Низкотемпературный усилитель пневматического сигнала Скачать файл
IL200 IL220-02-L Трехлинейный клапан блокировки Скачать файл
IL200 IL201, IL211 Клапан блокировки Скачать файл
INA-13-1014 INA-13-1014 Предохранительный клапан Скачать файл
IN-777 XT777F160-H005-200(J)-A, XT777F200-H006-200(J)-A Пневматический сервоцилиндр Скачать файл
IP200 IP200 Периодическое обслуживание позиционеров Скачать файл
IP200 IP200 Пневматический позиционер Скачать файл
IP300 IP300 / IP310 Пневматический позиционер Скачать файл
IP5000 IP5000 / IP5100 Пневматический позиционер Скачать файл
IP6000 IP6000 / IP6100 Электропневматический позиционер Скачать файл
IP6000 IP6000 / IP6100 Электропневматический позиционер Скачать файл
IP8000/8100 IP8000*-X308 / IP8100*-X308 Электропневматический позиционер Скачать файл
IP8000/8100 IP8000 / IP8100 Электропневматический позиционер Скачать файл
IP8100 IP8100-0*1-J
IP8100-0*1-JR
Электропневматический позиционер с датчиком обратной связи Скачать файл
IP8001 / IP8101 IP8101 Электропневматический позиционер с HART-интерфейсом Скачать файл
IP8001 / IP8101 IP8001 / IP8101 Интеллектуальный электропневматический позиционер Скачать файл
IP8001 / IP8101 IP8001 Электропневматический позиционер с HART-интерфейсом Скачать файл
IP8001 / IP8101 IP8101-002-X401 Интеллектуальный электропневматический позиционер Скачать файл
IR IR2000 Прецизионный регулятор давления Скачать файл
IR IR1000 Прецизионный регулятор давления Скачать файл
IR3000 IR3000 Прецизионный регулятор давления Скачать файл
IRV10/20 IRV10 IRV20
IRV10A IRV20A
Вакуумный регулятор Скачать файл
IS10 IS10 / IS10E / IS10M Реле давления Скачать файл
ISA2 ISA2 Датчик противодавления бесконтактного типа Скачать файл
ISE1 ZSE1/ISE1(L) Реле давления/вакуума Скачать файл
ISE10 ZSE10(F) / ISE10 Компактный датчик вакуума / давления с цифровой индикацией Скачать файл
ISE30 ZSE30 / ISE30 Прецизионный датчик давления Скачать файл
ISE35 ISE35 Реле давления с цифровой индикацией Скачать файл
ISE40 ZSE40 / ISE40 Прецизионный датчик давления Скачать файл
ISE70 ISE70/75/75H Реле давления с цифровой индикацией Скачать файл
ISE70/71 ISE70-L2, ISE71-L2 Прецизионное реле давления Скачать файл
ISE70/75/75H ISE70/ISE71/ISE70G/ISE75G/ISE76G/ISE77G Прецизионное реле давления Скачать файл
ISG 030 ISG110~130-030, ISG111~131-030, ISG210~230-030, ISG211~231-030 Реле давления общего назначения (без шкалы гистерезиса) Скачать файл
ISG 031 ISG110~130-031, ISG111~131-031, ISG210~230-031, ISG211~231-031 Реле давления общего назначения (со шкалой гистерезиса) Скачать файл
IT600 IT-600/601 Электропневматический взрывозащищенный преобразователь Скачать файл
ISE80 ZSE80/ISE80 Датчик давления / вакуума с двухцветной цифровой индикацией для различных сред Скачать файл
ISG ISG110~130-030, ISG111~131-030, ISG210~230-030, ISG211~231-030 Реле давления общего назначения (без шкалы гистерезиса) Скачать файл
ISG ISG110~130-031, ISG111~131-031, ISG210~230-031, ISG211~231-031 Реле давления общего назначения (со шкалой гистерезиса) Скачать файл
ITV ITV0000 Компактный электропневматический преобразователь Скачать файл
ITV ITV Преобразователи электропневматические Скачать файл
ITV ITV2000-3000 Электро- пневматический преобразователь Скачать файл
ITV2090, ITV2091 ITV2090 ITV2091 Преобразователи электропневматические Скачать файл
ITVH ITVH Электропневматический преобразователь высокого давления Скачать файл
ITVX ITVX Электропневматический преобразователь высокого давления Скачать файл
IW IW212, IW213, IW215 Фильтр/регулятор Скачать файл
IZF10 IZF10 Нейтрализатор статического электричества вентиляторного типа Скачать файл
IZH10 IZH10 Переносной измеритель электростатического заряда Скачать файл
IZN10 IZN10 Нейтрализатор статического электричества соплового типа Скачать файл
IZS IZS40, IZS41, IZS42 Нейтрализатор статического электричества Скачать файл
IZS31 IZS31 Высоковольтный нейтрализатор статического электричества Скачать файл
IZT IZT40/41/42 Нейтрализатор статического электричества Скачать файл
LEC LEC-GPR1 Шлюз для подключения драйвера LEC к сети PROFIBUS DP Скачать файл
LEC LECSA Драйвер серводвигателя переменного тока (импульсное управление/ управление по точкам) Скачать файл
LEC LECSB Драйвер серводвигателя переменного тока (импульсное управление) Скачать файл
LEC LECP1 Контроллер непрограммируемый для приводов с шаговым двигателем 24VDC Скачать файл
LEF LEFS / LEFB Бесштоковый электропривод Скачать файл
LEY LEY/LEYG Электропривод штокового типа (драйвер LEC) Скачать файл
LEY LEY/LEYG Электропривод штокового типа (драйверы LECS, LECSA, LECSB, LECSC, LECSS) Скачать файл
LFE LFE Электромагнитный цифровой датчик расхода жидкости Скачать файл
LMU, LMV LMU, LMV Станция смазки и обдува, Клапан-смеситель Скачать файл
LVA LVA / LVC Клапан для химически активных и особо чистых сред Скачать файл
MB MB-Z Пневматический цилиндр Скачать файл
MHS MHS2 MHS3 MHS4 Пневматический захват параллельного типа Скачать файл
MY1 MY1B Бесштоковый ленточный пневмоцилиндр Скачать файл
PA PA3000/5000 Пневматическая помпа с автоматическим управлением Скачать файл
PA PA3313 Пневматическая помпа с автоматическим управлением Скачать файл
PA PA5000 Пневматическая помпа с автоматическим управлением Скачать файл
PAF PAF3410, PAF3413
PAF5410, PAF5413
Помпа Скачать файл
PB PB Малая пневматическая помпа Скачать файл
PF2 PF2A20□ / PF2W20□ / PF2D20□ Четырехканальный выносной монитор Скачать файл
PF2#3# PF2A300/301, PF2A310/311, PF2D300/301, PF2W300/301, PF2W330/331 Модуль индикации для датчика расхода воздуха Скачать файл
PF2A PF2A7□H Датчик расхода воздуха c цифровой индикацией Скачать файл
PF2A PF2A5 Датчик расхода воздуха Скачать файл
PF2A PF2A7 Датчик расхода воздуха с цифровой индикацией Скачать файл
PF2D PF2D5 Датчик расхода для различных сред Скачать файл
PF2W PF2W Датчик расхода воды с цифровой индикацией Скачать файл
PF3A PF3A703H PF3A706H PF3A712H Датчик расхода воздуха с цифровой индикацией для пневматических магистралей Скачать файл
PF3W PF3W5 Датчик расхода жидкости с выносным дисплеем Скачать файл
PF3W PF3W7 Датчик расхода жидкости с трехцветной цифровой индикацией Скачать файл
PFA PFA Датчик расхода воздуха Скачать файл
PFA PFA7*H Расходомер Скачать файл
PFG3  PFG3#0 Выносной дисплей Скачать файл
PFM PFM5□□ Датчик расхода газа с выносным контроллером Скачать файл
PFM PFM7 Датчик расхода воздуха c цифровой индикацией Скачать файл
PFMB PFMB7501 PFMB7102
PFMB7202
Датчик расхода воздуха с цифровой индикацией Скачать файл
PFMC PFMC7501 PFMC7102 PFMC7202 Датчик расхода воздуха с цифровой индикацией Скачать файл
PFMV PFMV3 Контроллер для датчиков расхода Скачать файл
РРА РРА Переносной цифровой манометр Скачать файл
PSE200 PSE200 4-канальный контроллер для датчиков давления Скачать файл
PSE300 PSE300 Контроллер для датчиков давления Скачать файл
PSE530 PSE530 Датчик давления Скачать файл
PSE550 PSE550 Датчик перепада давлений Скачать файл
PSE560 PSE560 Датчик давления Скачать файл
PSE570 PSE575 / PSE576 / PSE577 Датчики давления для различных сред Скачать файл
REC REC Пневмоцилиндр с плавным разгоном и торможением в конце хода Скачать файл
SFB SFB100-02, SFB200-02, SFB101-02, SFB201-02, SFB102-02, SFB202-02, SFB103-02, SFB203-02, SFB104-M5 Фильтр сверхтонкой очистки Скачать файл
SRH SRH Регулятор давления для разных сред Скачать файл
SY New SY3000/5000 5/2, 5/3, 2×3/2 пневмораспределитель с электропневматическим управлением Скачать файл
SY SY100 3-линейный пневмораспределитель Скачать файл
VBA VBA10A/20A/40A Усилитель давления Скачать файл
VBA40A VBA40A Усилитель давления Скачать файл
VBAT VBAT20A1(-(R)V) / 38A1(-(R)V) / 40A1(-(R)V) Ресивер для сжатого воздуха Скачать файл
VCHR VCHR Регулятор с прямым управлением Скачать файл
VEX1#3 VEX1_33 Прецизионный регулятор давления Скачать файл
VEX1* VEX1*-X3 Прецизионный регулятор давления Скачать файл
VEX VEX5 Многофункциональный клапан Скачать файл
VF VF1000/3000/5000 5/2, 5/3 пневмораспределители с электропневматическим управлением Скачать файл
VF 50-VF3 Взрывозащищенная электромагнитная катушка пневмораспределителя Скачать файл
VF 50-VFE3*20-X81, 50-VFE3*20-X81R1 Клапан пневматический регулирующий с маркировкой взрывозащиты II Gb T5 X, с электромагнитным исполнительным механизмом с маркировкой взрывозащиты 1ExdIICT5X Скачать файл
VFN200N, VFN2000N VFN200N, VFN2000N 3/2, 5/2 пневмораспределитель с присоединительной поверхностью по стандарту NAMUR Скачать файл
VFS VFS2000 5/2, 5/3 пневмораспределитель с электропневматическим управлением Скачать файл
VG VG342 3/2 пневмораспределитель с электропневматическим управлением Скачать файл
VG VG342-5DZ-06F-X87 Сдвоенный пневмораспределитель Скачать файл
VGA VGA342R 3/2 пневмораспределитель с пневматическим управлением Скачать файл
VH VH200 / VH300 / VH400 / VH600 4/2, 4/3 пневмораспределитель с ручным управлением Скачать файл
VHS VHS20-(F,N)01~02(-B,R,Z)
VHS30-(F,N)02~03(-B,R,Z)
VHS40-(F,N)02~04(-B,R,Z)
VHS40-(F,N)06(-B,R,Z)
VHS50-(F,N)06~10(-B,R,Z)
3-линейный клапан со сбросом остаточного давления Скачать файл
VK VK300 / VK3000 3/2, 5/2 пневмораспределитель с прямым электромагнитным управлением Скачать файл
VNA EVNA 2/2 клапан для пневматических и пневмогидравлических систем Скачать файл
VNB VNB 2/2 клапан для управления потоками различных сред Скачать файл
VNC VNH VNC VNH 2/2 клапан для СОЖ  2/2 клапан для СОЖ высокого давления Скачать файл
VP VP(A)300/500/700 3/2 Пневмораспределитель с электропневматическим управлением Скачать файл
VP VP3000 3/2 пневмораспределитель c электропневматическим управлением для больших расходов Скачать файл
VP VP4000 Пневмораспределитель с электромагнитным управлением Скачать файл
VP VPA3145/3165/3185 3/2 пневмораспределитель с пневматическим управлением для больших расходов Скачать файл
VS VS4130/4140 5/2 пневмораспределитель прямого управления Скачать файл
VS VS31*5, VS41*0, VS42*0, VS43*0, VS44*0 Распределители с прямым электромагнитным управлением Скачать файл
VS VS3115-025-*-X59 Низкотемпературный пневмораспределитель с прямым электромагнитным управлением Скачать файл
VS VS3115-X59 Низкотемпературный пневмораспределитель с прямым электромагнитным управлением Скачать файл
VS VS3145-044TP-X59 Низкотемпературный пневмораспределитель с прямым электромагнитным управлением Скачать файл
VS EVS7 5/2, 5/3 пневмораспределители по стандарту ISO/CNOMO Скачать файл
VSA VSA31□5
VSA4□□0
3/2, 5/2, 5/3 пневмораспределители с пневмоуправлением Скачать файл
VSA EVSA7-6
EVSA7-8
5/2, 5/3 пневмораспределители с пневмоуправлением Скачать файл
VSH VSH4#10 5/2, 5/3 пневмораспределитель с ручным управлением Скачать файл
VT VT317 3-линейный пневмораспределитель с прямым электроуправлением Скачать файл
VX21/22/23 VX21, VX22, VX23 2/2 клапан с прямым управлением для различных сред Скачать файл
VX21/22/23 VX21/22/23 2/2 клапан с прямым управлением для различных сред Скачать файл
VX31/32/33 VX31/32/33 3/2 Клапан с электромагнитным управлением Скачать файл
VXD VXD21 / VXD22 / VXD23 2/2 клапан диафрагменного типа для различных сред Скачать файл
VXF2 VXF(A)2 2/2 клапан для встряхивания рукавных фильтров Скачать файл
VXFC VXFC06A / VXFC10A Контроллер на 6 / 10 выходов (клапанный регулятор) Скачать файл
VXFC VXFC06D / VXFC10D
VXFC06D-6 / VXFC10D-6
Контроллер на 6 / 10 выходов (клапанный регулятор) Скачать файл
VXH VXH 2/2 клапан на высокое давление Скачать файл
VXP EVXP21/22/23 2/2 клапан тарельчатого типа для различных сред Скачать файл
VXZ VXZ22/23 2/2 клапан для работы при нулевом перепаде давления Скачать файл
XL ХLA Угловой высоковакуумный клапан Скачать файл
XL XLCV Угловой высоковакуумный клапан Скачать файл
XL XLF Угловой высоковакуумный клапан Скачать файл
XL XLH Высоковакуумный угловой клапан с ручным управлением Скачать файл
XL XLS Угловой высоковакуумный клапан Скачать файл
ХMA ХMA Угловой высоковакуумный клапан Скачать файл
XMH XMH Клапан на высокий вакуум Скачать файл
XMC / XYC XMC / XYC Высоковакуумные угловые / прямые клапаны с корпусом из нержавеющей стали Скачать файл
XSA XSA Клапан для напуска чистых газов Скачать файл
ZH ZH Вакуумный эжектор Скачать файл
ZL ZL212 Мультиступенчатый вакуумный эжектор Скачать файл
ZM ZM Двухступенчатый вакуумный эжектор Скачать файл
ZQ ZQ Вакуумный эжектор Скачать файл
ZSE20A/ISE20A ZSE20A(F) / ISE20A Датчики давления Скачать файл
ZSE20B/ISE20B ZSE20B(F) / ISE20B Датчики давления Скачать файл
ZSE20C/ISE20C ZSE20C(F) / ISE20C(H) Датчики давления Скачать файл
ZSE30A/ISE30A ZSE30A(F)/ISE30A Прецизионный датчик давления/вакуума с двухцветной цифровой индикацией Скачать файл
ZSE80/ISE80 ZSE80/ISE80 Датчик давления/вакуума с двухцветной цифровой индикацией для различных сред Скачать файл

  • Позиционер пневматический для МИМ SMC IP5000
  • Позиционер электро-пневматический для МИМ SMC IP8000 (аналоговый)
  • Позиционер электро-пневматический для МИМ SMC IP8001 (цифровой «SMART»)
  • Фильтр-регулятор давления воздуха для МИМ SMC серии AW
  • Усилитель пневматического сигнала для МИМ SMC EIL100-F02-L
  • Клапаны SMC функции открыт/закрыт (пневмораспределители)
  • Бесконтактные индуктивные датчики положении (общепромышленные и взрывозащищенные)
  • Термочехол для мембранного исполнительного механизма (МИМ)

Позиционер электро-пневматический для МИМ SMC IP8001 (цифровой "SMART")

«SMART» электропневматический позиционер линейного типа. Предназначен для PID-регулирования перемещения исполнительных механизмов. Данные устройства имеют обратную связь со штоком клапана, поэтому превосходят по точности своей работы токовые задатчики и прямое управление пневматическим сигналом.

Укажите необходимую характеристику системы. Цена по запросу!

  • Характеристики
  • Доставка и оплата
  • Характеристики

    Характеристики Дополнительное оборудование к МИМ

    • Высокая точность позиционирования
    • Управление посредством входного сигнала (4 ~ 20 мА DC)
    • Простые (в сравнении с электромеханическим аналогом) настройки
    • Возможность использования двух настраиваемых дискретных выходов
    • Возможность использования аналогового выхода (4 ~ 20 мА DC) для мониторинга степени открытия исполнительного механизма
    • Взрывозащищенное и низкотемпературное взрывозащищенное исполнения
    • Исполнение с HART интерфейсом
    • Контролируемые параметры выводятся на LCD дисплей
    • Присоединительные размеры аналогичны электропневматическим позиционерам серий IP6100 и IP8100

    Модель IP8001
    Тип Линейный
    Входной сигнал (мА DC) 4 ∼ 20 (минимальный входной ток 3,85)
    Напряжение между терминалами (V DC) 12 (входное сопротивление эквивалентно 600 Ом при 20мА DC)
    Макс. потребляемая мощность (Вт) 1 (100 мА, 28 V DC)
    Диапазон рабочих давлений (МПа) 0.14 ∼ 0.7
    Рабочий ход 10 ∼ 85 мм (угол поворота) рычага обратной связи 10°C ∼ 30°C)
    Чувствительность (% от полного диапазона) ≤±0.2
    Линейность (% от полного диапазона) ≤±1
    Гистерезис (% от полного диапазона) ≤0.5
    Воспроизводимость ≤±0.5% (от полного диапазона)
    Влияние температуры ≤0.05% (от полного диапазона)/℃
    Влияние давления питания ≤0.3% (от полного диапазона) / 0.01 МПа
    Расход на выходе (норм.л/мин) ≥80 (при давлении питания 0.14 МПа)
    Потребление сжатого воздуха (норм.л/мин) ≤2 (при давлении питания 0.14 МПа), 
    ≤4 (при давлении питания 0.4 МПа)
    Температура рабочей и окружающей среды (℃) -20 ∼ 80 (стандартное и взрывозащищенное исполнение),
    -40 ∼ 60 (низкотемпературное взрывозащищенное исполнение)
    Кабельный ввод G 1/2, M20x1.5 (взрывозащищенное исполнение)
    Степень защиты JIS F8007 IP65
    Присоединение Rc 1/4, G 1/4
    Режим передачи данных HART-протокол
    Маркировка взрывозащиты ExiallCT4X
    Материал корпус и крышка — алюминиевый сплав (покрытие — эпоксидная смола),
    вал и винт-нержавеющая сталь  
    Вес (кг) 2.6
  • Доставка и оплата

    Способы
    доставки

    Доставка продукции осуществляется транспортными компаниями Деловые Линии, ПЭК, Желдорэкспедиция, Байкал-Сервис или
    собственными автомобилями*:

    • I.   МАН (до 20 тонн)

    • II.  Мерседес (до 20 тонн)

    • III. Хёндай (до 6,5 тонн)

    • IV. Газель (до 1,5 тонн)

    * — цену доставки продукции уточняйте при оформлении.

    Оплата
    заказа

    Если продукция в наличии или срок изготовления 3-5 рабочих дней: предлагаем 100% предоплаты. Если срок изготовления
    существенный: предлагаем 50% предоплаты, остальное – по факту готовности продукции к отгрузке. Возможны и иные способы
    оплаты.

наверх

Понравилась статья? Поделить с друзьями:
  • Смарт часы huawei tia b09 инструкция
  • Смарт паста для ногтей инструкция по применению
  • Смарт часы honor magic watch 2 инструкция
  • Смарт омега для детей инструкция
  • Смарт часы honor band 6 инструкция на русском