Supermicro aoc s3108l h8ir 16dd инструкция

Supermicro AOC-S3108L-H8iR User Manual

  1. Manuals
  2. Brands
  3. Supermicro Manuals
  4. PCI Card
  5. AOC-S3108L-H8iR
  6. User manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

AOC-S3108L-H8iR

User’s Guide

Revision 1.0a

loading

Related Manuals for Supermicro AOC-S3108L-H8iR

Summary of Contents for Supermicro AOC-S3108L-H8iR

  • Page 1
    AOC-S3108L-H8iR User’s Guide Revision 1.0a…
  • Page 2
    Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro’s total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3: An Important Note To The User

    This user’s guide is written for system integrators, IT professionals, and knowledgeable end users. It provides information for the installation and use of the AOC-S3108L-H8iR add-on card. An Important Note to the User All images and layouts shown in this user’s guide are based upon the latest PCB revision available at the time of publishing of this user guide.

  • Page 4: Important Links

    Product safety info: http://www.supermicro.com/about/policies/safety_informa- tion.cfm • If you have any questions, please contact our support team at: support@ supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level.

  • Page 5: Contacting Supermicro

    Preface Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V.

  • Page 6: Table Of Contents

    Chapter 1 Introduction Overview ………………….1-1 About this Add-on Card ………………. 1-1 Key Features ………………..1-1 Supermicro Motherboard Support …………..1-2 Chapter 2 Hardware Components Add-On Card Image and Layout …………..2-1 Major Onboard Components …………….2-1 SAS 3.0 Ports and CPLD JTAG Header …………2-2 SAS Ports ………………..

  • Page 7
    Table of Contents Properties ………………….4-9 Foreign View ………………..4-10 Chapter 5 MegaRAID Controller Firmware Update Procedures Flashing Firmware Using MegaCLI under DOS ……….5-1 Flashing Firmware Using MegaRAID Storage Manager …….. 5-3 Chapter 6 MegaRAID CacheCade Configuration Enabling MegaRAID CacheCade Support …………6-1 Minimum System Configuration Requirements ……….
  • Page 8
    AOC-S3108L-H8iR User’s Guide Notes…
  • Page 9: Chapter 1 Introduction

    Introduction Overview Congratulations on purchasing your add-on card from an acknowledged leader in the industry. Supermicro products are designed with the utmost attention to detail to provide you with the highest standards in quality and performance. About this Add-on Card The Supermicro AOC-S3108L-H8iR is the most technological-advanced, cost- effective, and reliable SAS MegaRAID adapter in today’s market.

  • Page 10: Supermicro Motherboard Support

    AOC-S3108L-H8iR User’s Guide • 2GB DDR3 ECC Unbuffered on-card cache with a speed of up to 1866MHz for cached data protection • Advanced array configuration and management utilities • Automatically-negotiated PCI-E link widths • Port-independent auto-negotiation • Supports SSP, SMP, STP and SATA protocols •…

  • Page 11
    Chapter 1: Overview • X10SRH-CF • X10SRH-CLN4F • X10SRi-F • X10SRL-F • X10SRW-F • X10DAi • X10DAC • X10DAX • X10DAL-i • X10DRC-T4+ • X10DRC-LN4+ • X10DRi-T4+ • X10DRi-LN4+ • X10DRD-iNTP • X10DRD-LTP • X10DRFF-C • X10DRFR-T • X10DRT-P • X10DRG-Q •…
  • Page 12
    AOC-S3108L-H8iR User’s Guide • X10DRL-CT • X10DRL-i • X10DRT-L • X10DRT-LIBQ • X10DRT-LIBF • X10DRU-i+ • X10DRW-E • X10DRW-N • X10DRX…
  • Page 13: Chapter 2 Hardware Components

    4 5 6 BUZZER1 AOC-S3108L-H8iR PCI-E 3.0 x8 Rev. 1.02 The AOC-S3108L-H8iR Image Major Onboard Components The following major components are installed on the AOC-S3108L-H8iR: Major Components Component Name Component Name Component Name 3108 SAS CTRL SAS ports 0~3 LED1: Activity LED…

  • Page 14: Sas 3.0 Ports And Cpld Jtag Header

    AOC-S3108L-H8iR User’s Guide SAS 3.0 Ports and CPLD JTAG Header SAS Ports Eight SAS ports, supported by the Avago 3108 SAS controller, are located on the add-on card. SAS 0-3 and SAS 4-7 support SAS 3.0 connections. See the table below for pin definitions.

  • Page 15: Led Indicators

    Definition Green: Blinking System: Normal Off or Red System: Dis- abled or Failed 1. SAS Activity LED BAR CODE 2. SAS Fault LED SAS Controller SAS CODE 3. System Heartbeat 1 2 3 BUZZER1 AOC-S3108L-H8iR PCI-E 3.0 x8 Rev. 1.02…

  • Page 16
    AOC-S3108L-H8iR User’s Guide Notes…
  • Page 17: Chapter 3 Installation

    Chapter 3: Installation Chapter 3 Installation Note: Your system came with the AOC-S3108L-H8iR adapter pre-in- stalled as a part of an integrated solution. We do not recommend that any part of your system components be removed and re-installed. However, if you do need to remove or re-install a system component, including this add-on card, please follow the instructions below to ensure proper system setup.

  • Page 18: Before Installation

    AOC-S3108L-H8iR User’s Guide Before Installation To install the add-on card properly, be sure to follow the instructions below. 1. Power down the system. 2. Remove the power cord from the wall socket. 3. Use industry-standard anti-static equipment (such as gloves or wrist strap) and follow the instructions listed on Page 3-1 to avoid damage caused by ESD.

  • Page 19: Chapter 4 Configuring The Avago Megaraid Setting

    OS installation. RAID Minimum Drive Requirements The AOC-S3108L-H8iR add-on card supports up to 240 HDD with RAID 0, 1, 5, 6, 10, 50, and 60. Use the table below to determine the minimum number of hard drives needed to set up a RAID environment.

  • Page 20: Using The Avagp Megaraid Configuration Utility

    AOC-S3108L-H8iR User’s Guide Using the Avagp MegaRAID Configuration Utility Follow the steps below to start the Avago MegaRAID Configuration Utility. 1. Power on the system. 2. Press <Ctrl><R> to enter the Avago MegaRAID Configuration Utility when the following screen displays.

  • Page 21: The Avago Megaraid Main Screen

    Chapter 4: Configuring the Avago MegaRAID Setting The Avago MegaRAID Main Screen On the top of the Avago MegaRAID main screen is a list of configurable menus. Press <Ctrl><N> or <Ctrl><P> to select the menu. The main screen includes the following menus: •…

  • Page 22: Vd Mgmt (Virtual Drive Management)

    AOC-S3108L-H8iR User’s Guide VD Mgmt (Virtual Drive Management) When you enter the MegaRAID Configuration Utility, the VD Mgmt is the first menu screen that displays, as shown below. This screen provides information about the configuration of controllers, drive groups, and virtual drives. The right panel of the screen displays the information about the selected device.

  • Page 23
    Chapter 4: Configuring the Avago MegaRAID Setting Move the cursor to select the controller and press <F2>, as shown below. Press <Enter> to create new virtual drives when the following screen displays. Note You can use the up arrow and down Arrow keys here to select enabled com- mands, which are highlighted in white, such as “Create Virtual Drive”…
  • Page 24
    AOC-S3108L-H8iR User’s Guide Use the up arrow and down arrow keys to select the RAID level, as shown below, and press <Enter>. Note The corresponding RAID level(s) will display based on the number of hard drives connected to the selected controller.
  • Page 25: Pd Mgmt (Physical Drive Management)

    Chapter 4: Configuring the Avago MegaRAID Setting PD Mgmt (Physical Drive Management) Press <Ctrl><N> or <Ctrl><P> to select the PD Mgmt menu, as shown below. This screen provides information about hard drives connected to the selected controller. The right panel of the screen shows the information about the selected device. PD Mgmt (Physical Management) Menu Screen To select a device, use the up arrow, down arrow or <Tab>…

  • Page 26: Ctrl Mgmt (Control Management)

    AOC-S3108L-H8iR User’s Guide Ctrl Mgmt (Control Management) Press <Ctrl><N> or <Ctrl><P> to select the Ctrl Mgmt menu, as shown below. This menu provides information about the settings of the selected controller. On this screen, use the up arrow, down arrow or <Tab> keys to move the cursor. To apply changes, navigate to APPLY and press <Enter>.

  • Page 27: Properties

    Chapter 4: Configuring the Avago MegaRAID Setting Properties Press <Ctrl><N> or <Ctrl><P> to select the Properties menu, as shown below. This menu provides read-only information about the properties of the selected controller. Navigate to Next and press <Enter> to open the second screen to view more prop- erties, as shown below.

  • Page 28: Foreign View

    AOC-S3108L-H8iR User’s Guide Foreign View Press <Ctrl><N> or <Ctrl><P> to select the Foreign View menu, as shown below. This menu provides information about the foreign configurations, such as drive groups, virtual drives, physical drives, and hot spare drives. Also, this menu al- lows you to import or clear the foreign configurations.

  • Page 29: Flashing Firmware Using Megacli Under Dos

    Chapter 5 MegaRAID Controller Firmware Update Procedures This chapter provides instructions on how to flash MegaRAID controller firmware. Please visit our website at www.supermicro.com for more information about firm- ware/utilities downloads. Flashing Firmware Using MegaCLI under DOS 1. You need the MegaCLI utility and ROM file (smc3108.rom) to flash the Mega- RAID firmware.

  • Page 30
    AOC-S3108L-H8iR User’s Guide 3. The screen below shows an example of flashing the MegaRAID firmware using the batch file (smc3108.bat). 4. Reboot the system and check the firmware version in the controller banner during boot up as shown below.
  • Page 31: Flashing Firmware Using Megaraid Storage Manager

    Chapter 5: MegaRAID Controller Firmware Update Procedures Flashing Firmware Using MegaRAID Storage Manager You need the MegaRAID Storage Manager software and ROM file (smc3108.rom) to flash the MegaRAID firmware. Follow the steps below to use the MegaRAID Storage Manager software on the following platforms: Micorsoft Windows operating system and Linux operating system.

  • Page 32
    AOC-S3108L-H8iR User’s Guide MegaRAID Storage Manager Screen on a Linux Operating System…
  • Page 33
    Chapter 5: MegaRAID Controller Firmware Update Procedures 3. Press the Browse button to search for new firmware. 4. Select the new MegaRAID controller firmware as shown below. 5. Click OK to continue. MegaRAID Storage Manager Screen on a Microsoft Windows Operating System MegaRAID Storage Manager Screen on a Linux Operating System…
  • Page 34
    AOC-S3108L-H8iR User’s Guide 6. Check Confirm in the dialog box and click Yes to continue, as shown below. MegaRAID Storage Manager Screen on a Microsoft Windows Operating System MegaRAID Storage Manager Screen on a Linux Operating System…
  • Page 35
    Chapter 5: MegaRAID Controller Firmware Update Procedures 7. Do not reboot the system until the following screen displays. 8. Click OK once the firmware update is completed as shown below. MegaRAID Storage Manager Screen on a Microsoft Windows Operating System MegaRAID Storage Manager Screen on a Linux Operating System…
  • Page 36
    AOC-S3108L-H8iR User’s Guide 9. Reboot the system and check the firmware version using the MegaRAID Storage Manager application as shown below. MegaRAID Storage Manager Screen on a Microsoft Windows Operating System MegaRAID Storage Manager Screen on a Linux Operating System…
  • Page 37: Enabling Megaraid Cachecade Support

    Chapter 6 MegaRAID CacheCade Configuration This chapter provides instructions on how to configure MegaRAID CacheCade set- tings in the Windows environment. Please refer to our website at www.supermicro. com for information on firmware/utilities downloads. Enabling MegaRAID CacheCade Support Minimum System Configuration Requirements You will need to have the following items pre-installed in your system before con- figuring MegaRAID CacheCade settings.

  • Page 38: Cachecade Key Activation

    AOC-S3108L-H8iR User’s Guide CacheCade Key Activation The following section provides instructions on how to activate your CacheCade key for proper MegaRAID CacheCade support. 1. From the MegaRAID Storage Manager menu, select Dashboard by clicking on it. 2. Double-click on Manage MegaRAID Adanced Software Options as shown below.

  • Page 39
    Chapter 6: CacheCade Configuration 4. When the following screen displays, click on the radio button «Enter an Activation Key» and then enter your Activation Key in the field provided as shown below.
  • Page 40: Configuring The Cachecade Raid Settings And Creating A Drive Group

    AOC-S3108L-H8iR User’s Guide Configuring the CacheCade RAID Settings and Creating a Drive Group To configure MegaCacheCade settings, please follow the instructions below. 1. From the MegaRAID Storage Manager menu, select Physical by clicking on 2. From the pull-down menu, select AVAGO 3108 MegaRAID by clicking on it.

  • Page 41
    Chapter 6: CacheCade Configuration 5. When the following screen displays, click on Select to select the RAID setting to configure for your HDDs. 6. Select your desired RAID setting to the hard drive you want to configure. 7. Click on Drive to invoke the pull-down submenu. From the pull-down sub- menu, select the hard drives you want to configure the RAID setting.
  • Page 42
    AOC-S3108L-H8iR User’s Guide 11. After adding all HDDs you want to use to create a drive group to the list, click on Create Drive Group to create a CacheCade drive group as shown below. 12. From the pull-down submenu, select the RAID setting you want to configure and click Next to assign the selected RAID setting to all HDDs included in the drive group list.
  • Page 43: Creating A Cachecade — Ssd Caching Virtual Drive

    Chapter 6: CacheCade Configuration Creating a CacheCade — SSD Caching Virtual Drive To create a SSD caching virtual drive, please follow the instructions below. 1. From the MegaRAID Storage Manager menu, select Physical by clicking on 2. From the pull-down menu, select AVAGO 3108 MegaRAID by clicking on it. 3.

  • Page 44
    AOC-S3108L-H8iR User’s Guide 10. To remove a virtual drive from a virtual drive group, select the drive to remove and click on Remove Virtual Drive. 11. To cancel the deletion, click on Cancel. 12. To proceed to the next step to configure the virtual drive settings, click Next.
  • Page 45: Configuring Virtual Drive Settings

    Chapter 6: CacheCade Configuration Configuring Virtual Drive Settings To configure the settings for a virtual drive, please follow the instructions below. 1. From the MegaRAID Storage Manager menu, select Logical by clicking on it. 2. From the Virtual Drive(s) pull-down menu, select the Virtual Drive you want to configure by clicking on it.

  • Page 46: Enabling Ssd Caching Support On A Virtual Drive

    AOC-S3108L-H8iR User’s Guide Enabling SSD Caching Support on a Virtual Drive To enable SSD Caching support for a virtual drive, please follow the instructions below. 1. From the MegaRAID Storage Manager menu, select Logical by clicking on it. 2. From the Virtual Drive(s) pull-down menu, select the Virtual Drive for SSD Caching support by clicking on it.

  • Page 47
    (Disclaimer Continued) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

Посмотреть инструкция для Supermicro AOC-S3108L-H8IR бесплатно. Руководство относится к категории контроллеры, 1 человек(а) дали ему среднюю оценку 6.7. Руководство доступно на следующих языках: английский. У вас есть вопрос о Supermicro AOC-S3108L-H8IR или вам нужна помощь? Задайте свой вопрос здесь

Главная
Supermicro
AOC-S3108L-H8IR | AOC-S3108L-H8IR
контроллер
0672042143450, 672042143450, 6720421434508, 0746290120324
английский
Руководство пользователя (PDF)
Порты и интерфейсы
Поддерживаемые интерфейсы носителя SAS-3
Внутренние SAS порты 8
Основной интерфейс PCI Express
Производительность
Скорость передачи данных 12 Gbit/s
Оперативная память 2048 MB
Тип внутренней памяти DDR3
Тактовая частота памяти 1866 MHz
Уровни RAID 0, 1,5, 6,10, 50, 60

показать больше

Не можете найти ответ на свой вопрос в руководстве? Вы можете найти ответ на свой вопрос ниже, в разделе часто задаваемых вопросов о Supermicro AOC-S3108L-H8IR.

Аккумулятор в моем устройстве контроллер начал ржаветь. Безопасно ли пользоваться устройством?

Инструкция Supermicro AOC-S3108L-H8IR доступно в русский?

Не нашли свой вопрос? Задайте свой вопрос здесь

Посмотреть все Supermicro руководства Посмотреть все Supermicro контроллер руководства

The information in this User’s Guide has been carefully reviewed and is believed to be accurate.

The vendor assumes no responsibility for any inaccuracies that may be contained in this document,

and makes no commitment to update or to keep current the information in this user’s guide, or to

notify any person or organization of the updates. Please Note: For the most up-to-date version

of this user’s guide, please see our Website at www.supermicro.com.

Super Micro Computer, Inc. («Supermicro») reserves the right to make changes to the product

described in this user’s guide at any time and without notice. This product, including software and

documentation, is the property of Supermicro and/or its licensors, and is supplied only under a

license. Any use or reproduction of this product is not allowed, except as expressly permitted by

the terms of said license.

IN NO EVENT WILL SUPER MICRO COMPUTER, INC. BE LIABLE FOR DIRECT, INDIRECT,

SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE

USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF

THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC.

SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED

WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING,

INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.

Any disputes arising between the manufacturer and the customer shall be governed by the laws of

Santa Clara County in the State of California, USA. The State of California, County of Santa Clara

shall be the exclusive venue for the resolution of any such disputes. Supermicro’s total liability for

all claims will not exceed the price paid for the hardware product.

FCC Statement: This equipment has been tested and found to comply with the limits for a Class A

digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable

protection against harmful interference when the equipment is operated in industrial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and

used in accordance with the manufacturer’s instruction manual, may cause harmful interference with

radio communications. Operation of this equipment in a residential area is likely to cause harmful

interference, in which case you will be required to correct the interference at your own expense.

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate

warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. «Perchlorate

Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate».

WARNING: This product can expose you to chemicals including

!

lead, known to the State of California to cause cancer and birth

defects or other reproductive harm. For more information, go

to www.P65Warnings.ca.gov.

User’s Guide Revision 1.0a

Release Date: July 02, 2020

Unless you request and receive written permission from Super Micro Computer, Inc., you may not

copy any part of this document.

Information in this document is subject to change without notice. Other products and companies

referred to herein are trademarks or registered trademarks of their respective companies or mark

holders.

Copyright © 2020 by Super Micro Computer, Inc.

All rights reserved.

Printed in the United States of America

Table of Contents for Supermicro AOC-S3108L-H8iR:

  • iv AOC-S3108L-H8iR User’s Guide Important Links For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server. • Supermicro product manuals: http://www.supermicro.com/support/manuals/ • Product drivers and utilities: https://www.supermicro.com/wftp/driver • Product safety info: http://www.supermicro.com/about/policies/safety_informa- tion.cfm �

  • 1-4 AOC-S3108L-H8iR User’s Guide • X10DRL-CT • X10DRL-i • X10DRT-L • X10DRT-LIBQ • X10DRT-LIBF • X10DRU-i+ • X10DRW-E • X10DRW-N • X10DRX

  • 5-8 AOC-S3108L-H8iR User’s Guide 9. Reboot the system and check the rmware version using the MegaRAID Storage Manager application as shown below. MegaRAID Storage Manager Screen on a Microsoft Windows Operating System MegaRAID Storage Manager Screen on a Linux Operating System

  • 6-5 Chapter 6: CacheCade Conguration 5. When the following screen displays, click on Select to select the RAID setting to congure for your HDDs. 6. Select your desired RAID setting to the hard drive you want to congure. 7. Click on Drive to invoke the pull-down submenu. From the pull-down sub- menu, select the hard drives you want to congure the RAID setting. 8. With the desired hard drive selected, click on the Add button to add the selected hard drive to your drive group list. 9. With all hard drives selected, click

  • vi AOC-S3108L-H8iR User’s Guide Notes

  • 1-2 AOC-S3108L-H8iR User’s Guide • 2GB DDR3 ECC Unbuffered on-card cache with a speed of up to 1866MHz for cached data protection • Advanced array conguration and management utilities • Automatically-negotiated PCI-E link widths • Port-independent auto-negotiation • Supports SSP, SMP, STP and SATA protocols • Optional Supercap/CacheVault BTR-TFM8G-LSICVM02 (Installation kit PN=MCP-240-001270N) • Supports MegaRAID Storage Manager software • Enlarged venting hole mounting bracket for

  • Chapter 1: Overview 1-1 Chapter 1 Introduction 1-1 Overview Congratulations on purchasing your add-on card from an acknowledged leader in the industry. Supermicro products are designed with the utmost attention to detail to provide you with the highest standards in quality and performance. 1-2 About this Add-on Card The Supermicro AOC-S3108L-H8iR is the most technological-advanced, cost- effective, and reliable SAS MegaRAID adapter in today’s market. With the Avago 3108 SAS controller, eight 12Gb/s SAS connec

  • 5-6 AOC-S3108L-H8iR User’s Guide 6. Check Conrm in the dialog box and click Yes to continue, as shown below. MegaRAID Storage Manager Screen on a Microsoft Windows Operating System MegaRAID Storage Manager Screen on a Linux Operating System

  • 6-3 Chapter 6: CacheCade Conguration 4. When the following screen displays, click on the radio button «Enter an Activation Key» and then enter your Activation Key in the eld provided as shown below.

  • 4-4 AOC-S3108L-H8iR User’s Guide 4-4 VD Mgmt (Virtual Drive Management) When you enter the MegaRAID Conguration Utility, the VD Mgmt is the rst menu screen that displays, as shown below. This screen provides information about the conguration of controllers, drive groups, and virtual drives. The right panel of the screen displays the information about the selected device. To select a submenu item, use the up arrow and down arrow keys. Use the right arrow to open a submenu, and the left arrow to cl

  • Chapter 2: Hardware Components 2-3 2-4 LED Indicators SAS Activity LED The SAS Activity LED is located at LED1 on the add-on card. When LED1 is blinking, the SAS connections supported by the Avago 3108 controller are active. See the table below for more information. SAS Activity LED Status Color/State Denition Green: Blinking SAS: Active SAS Fault LED LED6 is used to indicate if a SAS failure has occurred. When LED6 is on, an error has occurred to on-card SA

  • 5-4 AOC-S3108L-H8iR User’s Guide MegaRAID Storage Manager Screen on a Linux Operating System

  • 5-1 Chapter 5: MegaRAID Controller Firmware Update Procedures Chapter 5 MegaRAID Controller Firmware Update Procedures This chapter provides instructions on how to ash MegaRAID controller rmware. Please visit our website at www.supermicro.com for more information about rm- ware/utilities downloads. 5-1 Flashing Firmware Using MegaCLI under DOS 1. You need the MegaCLI utility and ROM le (smc3108.rom) to ash the Mega- RAID rmware. 2. Boot from the USB key and use the following command syntax as shown bel

  • 4-7 Chapter 4: Conguring the Avago MegaRAID Setting 4-5 PD Mgmt (Physical Drive Management) Press <Ctrl><N> or <Ctrl><P> to select the PD Mgmt menu, as shown below. This screen provides information about hard drives connected to the selected controller. The right panel of the screen shows the information about the selected device. PD Mgmt (Physical Management) Menu Screen To select a device, use the up arrow, down arrow or <Tab> keys and press

  • 3-2 AOC-S3108L-H8iR User’s Guide 3-2 Before Installation To install the add-on card properly, be sure to follow the instructions below. 1. Power down the system. 2. Remove the power cord from the wall socket. 3. Use industry-standard anti-static equipment (such as gloves or wrist strap) and follow the instructions listed on Page 3-1 to avoid damage caused by ESD. 4. Familiarize yourself with the server, motherboard, and/or chassis documenta- tion. 5. Make sure that your operating

  • Preface About this User’s Guide This user’s guide is written for system integrators, IT professionals, and knowledgeable end users. It provides information for the installation and use of the AOC-S3108L-H8iR add-on card. An Important Note to the User All images and layouts shown in this user’s guide are based upon the latest PCB revision available at the time of publishing of this user guide. The add-on card you

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Supermicro AOC-S3108L-H8iR device using right now.

View a manual of the Supermicro AOC-S3108L-H8IR below. All manuals on ManualsCat.com can be viewed completely free of charge. By using the ‘Select a language’ button, you can choose the language of the manual you want to view.

Page: 1

User’s Guide
Revision 1.0
AOC-S3108L-H8iR

Page: 2

User’s Guide Revision 1.0
Release Date: Oct. 28, 2015
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2015 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
The information in this User’s Guide has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
and makes no commitment to update or to keep current the information in this user’s guide, or to
notify any person or organization of the updates. Please Note: For the most up-to-date version
of this user’s guide, please see our Website at www.supermicro.com.
Super Micro Computer, Inc. («Supermicro») reserves the right to make changes to the product
described in this user’s guide at any time and without notice. This product, including software and
documentation, is the property of Supermicro and/or its licensors, and is supplied only under a
license. Any use or reproduction of this product is not allowed, except as expressly permitted by
the terms of said license.
IN NO EVENT WILL SUPER MICRO COMPUTER, INC. BE LIABLE FOR DIRECT, INDIRECT,
SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE
USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF
THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC.
SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED
WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING,
INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between the manufacturer and the customer shall be governed by the laws of
Santa Clara County in the State of California, USA. The State of California, County of Santa Clara
shall be the exclusive venue for the resolution of any such disputes. Supermicro’s total liability for
all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”.

WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.

Page: 3

Preface
About this User’s Guide
This user’s guide is written for system integrators, IT professionals, and
knowledgeable end users. It provides information for the installation and use of the
AOC-S3108L-H8iR add-on card.
An Important Note to the User
All images and layouts shown in this user’s guide are based upon the latest PCB
revision available at the time of publishing of this user guide. The add-on card you
have received may or may not look exactly the same as the graphics shown in
this user’s guide.
Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required be-
fore any warranty service will be rendered. You can obtain service by calling your
vendor for a Returned Merchandise Authorization (RMA) number. When returning to
the manufacturer, the RMA number should be prominently displayed on the outside
of the shipping carton and mailed prepaid or hand-carried. Shipping and handling
charges will be applied for all orders that must be mailed when service is complete.
For faster service, RMA authorizations may be requested online (http://www.super-
micro.com/support/rma/).
This warranty only covers normal consumer use and does not cover damages in-
curred in shipping or from failure due to the alteration, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor first for any product problems.
During the warranty period, contact your distributor first for any product problems.
Conventions Used in the User’s Guide
Pay special attention to the following symbols for proper system installation:
Warning: Important information given to ensure proper system installation and to avoid
causing damage to the components or causing injury to yourself.
Note: Additional information given for proper system setup.
Preface
iii

Page: 4

iv
AOC-S3108L-H8iR Add-on Card User’s Guide
Important Links
For your system to work properly, please follow the links below to download all
necessary drivers/utilities and the user’s manual for your server.
• Supermicro product manuals: http://www.supermicro.com/support/manuals/
• Product drivers and utilities: ftp://ftp.supermicro.com
• Product safety info: http://www.supermicro.com/about/policies/safety_informa-
tion.cfm
• If you have any questions, please contact our support team at: support@
supermicro.com
This manual may be periodically updated without notice. Please check the
Supermicro website for possible updates to the manual revision level.

Page: 5

v
Preface
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
‘s-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Web Site: www.supermicro.nl
Asia-Pacific
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3992
Email: support@supermicro.com.tw
Web Site: www.supermicro.com.tw

Page: 6

Table of Contents
Preface
About this User’s Guide……………………………………………………………………………………. 3
An Important Note to the User…………………………………………………………………………… 3
Returning Merchandise for Service…………………………………………………………………….. 3
Conventions Used in the User’s Guide……………………………………………………………….. 3
Important Links………………………………………………………………………………………………… 4
Contacting Supermicro……………………………………………………………………………………… 5
Chapter 1 Introduction
1-1 Overview……………………………………………………………………………………………. 1-1
1-2 About this Add-on Card………………………………………………………………………… 1-1
1-3 Key Features………………………………………………………………………………………. 1-1
1-4 Supermicro Motherboard Support………………………………………………………….. 1-2
Chapter 2 Hardware Components
2-1 Add-On Card Image and Layout……………………………………………………………. 2-1
2-2 Major Onboard Components…………………………………………………………………. 2-1
2-3 SAS 3.0 Ports and CPLD JTAG Header………………………………………………… 2-2
SAS Ports………………………………………………………………………………………. 2-2
CPLD JTAG Header………………………………………………………………………… 2-2
2-4 LED Indicators…………………………………………………………………………………….. 2-3
SAS Activity LED…………………………………………………………………………….. 2-3
SAS Fault LED……………………………………………………………………………….. 2-3
System Heartbeat LED……………………………………………………………………. 2-3
Chapter 3 Installation
3-1 Static-Sensitive Devices……………………………………………………………………….. 3-1
Precautions………………………………………………………………………………………… 3-1
3-2 Before Installation……………………………………………………………………………….. 3-2
3-3 Installing the Add-on Card……………………………………………………………………. 3-2
Chapter 4 Configuring the Avago MegaRAID Setting
4-1 RAID Minimum Drive Requirements………………………………………………………. 4-1
4-2 Using the Avagp MegaRAID Configuration Utility…………………………………….. 4-2
4-3 The Avago MegaRAID Main Screen………………………………………………………. 4-3
4-4 VD Mgmt (Virtual Drive Management)……………………………………………………. 4-4
4-5 PD Mgmt (Physical Drive Management)…………………………………………………. 4-7
4-6 Ctrl Mgmt (Control Management)………………………………………………………….. 4-8
AOC-S3108L-H8iR Add-on Card User’s Guide
vi

Page: 7

Table of Contents
4-7 Properties…………………………………………………………………………………………… 4-9
4-8 Foreign View…………………………………………………………………………………….. 4-10
Chapter 5 MegaRAID Controller Firmware Update Procedures
5-1 Flashing Firmware Using MegaCLI under DOS………………………………………5-11
5-2 Flashing Firmware Using MegaRAID Storage Manager…………………………. 5-13
Chapter 6 MegaRAID CacheCade Configuration
6-1 Enabling MegaRAID CacheCade Support………………………………………………. 6-1
Minimum System Configuration Requirements………………………………………… 6-1
CacheCade Key Activation…………………………………………………………………… 6-2
6-2 Configuring the CacheCade RAID Settings and Creating a Drive Group……. 6-4
6-3 Creating a CacheCade — SSD Caching Virtual Drive……………………………….. 6-7
6-4 Configuring Virtual Drive Settings………………………………………………………….. 6-9
6-5 Enabling SSD Caching Support on a Virtual Drive………………………………… 6-10
vi

Page: 8

vi
AOC-S3108L-H8iR Add-on Card User’s Guide
Notes

Page: 9

Chapter 1: Overview
1-1
Chapter 1
Introduction
1-1 Overview
Congratulations on purchasing your add-on card from an acknowledged leader in
the industry. Supermicro products are designed with the utmost attention to detail
to provide you with the highest standards in quality and performance.
1-2 About this Add-on Card
The Supermicro AOC-S3108L-H8iR is the most technological-advanced, cost-
effective, and reliable SAS MegaRAID adapter in today’s market. With the Avago
3108 SAS controller, eight 12Gb/s SAS connectors, and a low-profile PCI-E Gen.3
x8 slot built in, this add-on card offers high-performance connectivity with enormous
storage capacity to meet the growing needs of enterprise server platforms.
With the optional Supercap/TFM unit built-in, the AOC-S3108L-H8iR supports 2GB
DDR3 on-card cache at a speed of 1866 MHz (maximum), providing cached data
protection during catastrophic system failures.
In addition, the embedded Avago SAS 3108 I/O processor offers optimal RAID
performance and a PCI-Express host interface for increased I/O bandwidth. The
AOC-S3108L-H8iR adapter delivers an intelligent and robust RAID solution to the
market. For more information regarding product support or updates, please refer to
our website at http://www.supermicro.com/products/accessories/addon/aoc-s3108l-
h8ir.cfm.
1-3 Key Features
The key features of this add-on card include the following:
• Avago SAS 3108 8-port PCI-E SAS-3.0 controller
• Eight internal SAS3 ports w/two mini SAS HD connectors
• Hardware RAID 0, 1, 5, 6,10, 50, and 60 supported
• Onboard hardware I/O processor
• Supports up to 240 physical devices

Page: 10

1-2
AOC-S3108L-H8iR User’s Guide
• 2GB DDR3 ECC Unbuffered on-card cache with a speed of up to 1866MHz for
cached data protection
• Advanced array configuration and management utilities
• Automatically-negotiated PCI-E link widths
• Port-independent auto-negotiation
• Supports SSP, SMP, STP and SATA protocols
• Optional Supercap/CacheVault BTR-TFM8G-LSICVM02 (Installation kit
PN=MCP-240-001270N)
• Supports MegaRAID Storage Manager software
• Enlarged venting hole mounting bracket for improved airflow
• Supports 1.5, 3.0, 6.0 and 12.0 Gb/s SAS and 3.0 & 6.0 Gb SATA data transfer
rates
• OS support: Windows 2012, 2k8 64/32-bit, RedHat Enterprise, and SUSE Linux
• Support Fastpath(Free) and Cachecade (AOC-CHCD-PRO2-ESW)
• Power consumption: 23 watts
• Operation temperatures: 0°C to 55°C (32°F to 131°F)
• Dimensions 2.71″ (H) x 6.6″ (L) (68.83cm (H) x 167.64cm (L))
1-4 Supermicro Motherboard Support
This add-on card supports the following motherboards:
• X10SDV-TLN4F
• X10SRA-F
• X10SRD-F
• X10SRG-F

Page: 11

Chapter 2: Hardware Components
2-1
SAS CODE
BAR CODE
J1
J5
JP8
J2
J12
J4
U25
U26
U23
U24
U27
JP6
JP1
JP2
LED6
LED1
D13
DRIVE0-3
DRIVE4-7
BUZZER1
SAS
Connectors
AOC-S3108L-H8iR
Rev. 1.02
SAS Controller
PCI-E 3.0 x8
U12
U4
U435
Chapter 2
Hardware Components
2-1 Add-On Card Image and Layout
The AOC-S3108L-H8iR Image
C
A
B
1
2
2
3
4
2-2 Major Onboard Components
The following major components are installed on the AOC-S3108L-H8iR:
1
5 6
A
B
C
Major Components
No Component Name No Component Name No Component Name
A 3108 SAS CTRL 1 SAS ports 0~3 4 LED1: Activity LED
B Onboard Buzzer 2 SAS ports 4~7 5 LED6: Fault LED
C PCI-E 3.0 x8 slot 3 CPLD JTAG (header) 6
D13: System
Heartbeat LED
5 6
The AOC-S3108L-H8iR Image
3
4

Page: 12

2-2
AOC-S3108L-H8iR Add-on Card User’s Guide
2-3 SAS 3.0 Ports and CPLD JTAG Header
SAS 3.0
Pin Definitions
Pin# Signal
1 Ground
2 SATA_TXP
3 SATA_TXN
4 Ground
5 SATA_RXN
6 SATA_RXP
7 Ground
SAS Ports
Eight SAS ports, supported by the Avago 3108 SAS controller, are located on the
add-on card. SAS 0-3 and SAS 4-7 support SAS 3.0 connections. See the table
below for pin definitions.
SAS CODE
BAR CODE
J1
J5
JP8
J2
J12
J4
U25
U26
U23
U24
U27
JP6
JP1
JP2
LED6
LED1
D13
DRIVE0-3
DRIVE4-7
BUZZER1
SAS
Connectors
AOC-S3108L-H8iR
Rev. 1.02
SAS Controller
PCI-E 3.0 x8
U12
U4
U435
1
2
3
1. SAS Ports 0~3
2. SAS Ports 4~7
3. CPLD JTAG Scan
CPLD JTAG Header
A 6-pin CPLD JTAG header, located at JP8, is used to scan complex-programma-
ble logic devices. Connect a cable to JP8 for CPLD JTAG scan to enhance system
security and data integrity. See the layout below for the location.

Page: 13

Chapter 2: Hardware Components
2-3
2-4 LED Indicators
SAS CODE
BAR CODE
J1
J5
JP8
J2
J12
J4
U25
U26
U23
U24
U27
JP6
JP1
JP2
LED6
LED1
D13
DRIVE0-3
DRIVE4-7
BUZZER1
SAS
Connectors
AOC-S3108L-H8iR
Rev. 1.02
SAS Controller
PCI-E 3.0 x8
U12
U4
U435
1 2 3
1. SAS Activity LED
2. SAS Fault LED
3. System Heartbeat
LED
SAS Fault LED
Status
Color/State Definition
Red: On SAS Error(s)
detected
SAS Fault LED
LED6 is used to indicate if a SAS failure has occurred. When LED6 is on, an
error has occurred to on-card SAS connections. See the table below for more
information.
SAS Activity LED
Status
Color/State Definition
Green:
Blinking
SAS: Active
SAS Activity LED
The SAS Activity LED is located at LED1 on the add-on card. When LED1 is
blinking, the SAS connections supported by the Avago 3108 controller are active.
See the table below for more information.
System Heartbeat LED
The System Heartbeat LED is located at D13 on the add-on card. When D13 is
blinking, the system is functioning normally. See the table below for more infor-
mation.
System Heartbeat LED
Status
Color/State Definition
Green: Blinking System: Normal
Off or Red System: Dis-
abled or Failed

Page: 14

2-4
AOC-S3108L-H8iR Add-on Card User’s Guide
Notes

Page: 15

3-1
Chapter 3: Installation
Chapter 3
Installation
Note: Your system came with the AOC—S3108L-H8iR adapter pre-
installed as a part of an integrated solution. We do not recommend that
any part of your system components be removed and re-installed. How-
ever, if you do need to remove or re-install a system component, including
this add-on card, please follow the instructions below to ensure proper
system setup. Also, be sure to remove the power cord first before adding,
removing or changing any hardware components to avoid damaging the
system or components.
3-1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com­
ponents. To avoid dam-
aging your add-on card, it is important to handle it very carefully. The following
measures are generally sufficient to protect your equipment from ESD.
Precautions
• Use a grounded wrist strap designed to prevent static discharge.
• Touch a grounded metal object before removing the add-on card from the
antistatic bag.
• Handle the add-on card by its edges only; do not touch its components, or
peripheral chips.
• Put the add-on card back into the antistatic bags when not in use.
• For grounding purposes, make sure that your system chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the add-on card.

Page: 16

3-2
AOC-S3108L-H8iR Add-on Card User’s Guide
3-2 Before Installation
To install the add-on card properly, be sure to follow the instructions below.
1. Power down the system.
2. Remove the power cord from the wall socket.
3. Use industry-standard anti-static equipment (such as gloves or wrist strap)
and follow the instructions listed on Page 3-1 to avoid damage caused by
ESD.
4. Familiarize yourself with the server, motherboard, and/or chassis documenta-
tion.
5. Make sure that your operating system includes the latest updates and hot-
fixes.
3-3 Installing the Add-on Card
Follow the steps below to install the add-on card into your system.
1. Remove the server cover and, if necessary, set aside any screws for later
use.
2. Remove the add-on card slot cover. If the case requires a screw, place the
screw aside for later use.
3. Position the add-on card in the slot directly over the connector, and gently
push down on both sides of the card until it slides into the PCI connector.
4. Secure the add-on card to the chassis. If required, use the screw that you
previously removed.
5. Attach any necessary external cables to the add-on card.
6. Replace the chassis cover.
7. Plug the power cord into the wall socket, and power up the system.

Page: 17

4-1
Chapter 4: Configuring the Avago MegaRAID Setting
RAID Minimum Hard Drives
RAID 0 2
RAID 1 2
RAID 5 3
RAID 6 3
RAID 10 4 (Two RAID 1 arrays)
RAID 50 6 (Two RAID 5 arrays)
RAID 60 6 (Two RAID 6 arrays)
Chapter 4
Configuring the Avago MegaRAID Setting
This chapter provides instructions on how to configure MegaRAID settings for the
Avago 3108 SAS controller. If you do not wish to configure MegaRAID settings,
skip this section and go directly to OS installation.
4-1 RAID Minimum Drive Requirements
The AOC-S3108L-H8iR add-on card supports up to 240 HDD with RAID 0, 1, 5,
6, 10, 50 and 60. Use the table below to determine the minimum number of hard
drives needed to set up a RAID environment.

Page: 18

4-2
AOC-S3108L-H8iR Add-on Card User’s Manual
4-2 Using the Avagp MegaRAID Configuration Utility
Follow the steps below to start the Avago MegaRAID Configuration Utility.
1. Power on the system.
2. Press <Ctrl><R> to enter the Avago MegaRAID Configuration Utility when the
following screen displays.

Page: 19

4-3
Chapter 4: Configuring the Avago MegaRAID Setting
4-3 The Avago MegaRAID Main Screen
On the top of the Avago MegaRAID main screen is a list of configurable menus.
Press <Ctrl><N> or <Ctrl><P> to select the menu. The main screen includes the
following menus:
• VD Mgmt (Virtual Drive Management)
• PD Mgmt (Physical Management)
• Ctrl Mgmt (Controller Management)
• Properties
• Foreign View
Avago MegaRAID Configuration Utility Main Screen

Page: 20

4-4
AOC-S3108L-H8iR Add-on Card User’s Manual
4-4 VD Mgmt (Virtual Drive Management)
When you enter the MegaRAID Configuration Utility, the VD Mgmt is the first menu
screen that displays, as shown below. This screen provides information about the
configuration of controllers, drive groups, and virtual drives. The right panel of the
screen displays the information about the selected device. To select a submenu item,
use the up arrow and down arrow keys. Use the right arrow to open a submenu,
and the left arrow to close a submenu.
VD Mgmt (Virtual Management) Menu Screen

Page: 21

4-5
Chapter 4: Configuring the Avago MegaRAID Setting
Move the cursor to select the controller and press <F2>, as shown below. Press
<Enter> to create new virtual drives when the following screen displays.
Note You can use the up arrow and down Arrow keys here to select enabled com-
mands, which are highlighted in white, such as “Create Virtual Drive” or “Clear
Configuration”.
Press <Enter> for the RAID level selection when the screen below shows. This
screen also allows you to select parameters of the new virtual drive using the up
arrow, down arrow, or <Tab> keys.

Page: 22

4-6
AOC-S3108L-H8iR Add-on Card User’s Manual
Use the up arrow and down arrow keys to select the RAID level, as shown below,
and press <Enter>.
Note The corresponding RAID level(s) will display based on the number of hard
drives connected to the selected controller.

Page: 23

4-7
Chapter 4: Configuring the Avago MegaRAID Setting
4-5 PD Mgmt (Physical Drive Management)
Press <Ctrl><N> or <Ctrl><P> to select the PD Mgmt menu, as shown below. This
screen provides information about hard drives connected to the selected controller.
The right panel of the screen shows the information about the selected device.
PD Mgmt (Physical Management) Menu Screen
To select a device, use the up arrow, down arrow or <Tab> keys and press <F2>.
Press <Enter> to perform a command, such as rebuilding a failed drive, locating a
drive, or making a drive offline, as shown below.

Page: 24

4-8
AOC-S3108L-H8iR Add-on Card User’s Manual
4-6 Ctrl Mgmt (Control Management)
Press <Ctrl><N> or <Ctrl><P> to select the Ctrl Mgmt menu, as shown below. This
menu provides information about the settings of the selected controller. On this
screen, use the up arrow, down arrow or <Tab> keys to move the cursor. To apply
changes, navigate to APPLY and press <Enter>.
Navigate to Next and press <Enter> to open the second screen, as shown below.
The following screen allows you to view and changes settings, such as the link
speed or the power save.

Page: 25

4-9
Chapter 4: Configuring the Avago MegaRAID Setting
4-7 Properties
Press <Ctrl><N> or <Ctrl><P> to select the Properties menu, as shown below. This
menu provides read-only information about the properties of the selected controller.
Navigate to Next and press <Enter> to open the second screen to view more prop-
erties, as shown below. To go back to the first screen, navigate to Prev (Previous)
and press <Enter>.

Page: 26

4-10
AOC-S3108L-H8iR Add-on Card User’s Manual
4-8 Foreign View
Press <Ctrl><N> or <Ctrl><P> to select the Foreign View menu, as shown below.
This menu provides information about the foreign configurations, such as drive
groups, virtual drives, physical drives, and hot spare drives. Also, this menu al-
lows you to import or clear the foreign configurations. Please note that the Foreign
View menu displays only when a foreign configuration has been connected to the
controller.
Foreign View Menu Screen

Page: 27

5-11
Chapter 5: MegaRAID Controller Firmware Update Procedures
Chapter 5
MegaRAID Controller Firmware Update Procedures
This chapter provides instructions on how to flash MegaRAID controller firmware.
Please visit our website at www.supermicro.com for more information about firm-
ware/utilities downloads.
5-1 Flashing Firmware Using MegaCLI under DOS
1. You need the MegaCLI utility and ROM file (smc3108.rom) to flash the Mega-
RAID firmware.
2. Boot from the USB key and use the following command syntax as shown below,
or run the batch file.
megacli –adpfwflash –f <filename.rom> -a0

Page: 28

5-12
AOC-S3108L-H8iR Add-on Card User’s Manual
3. The screen below shows an example of flashing the MegaRAID firmware using
the batch file (smc3108.bat).
4. Reboot the system and check the firmware version in the controller banner during
boot up as shown below.

Page: 29

5-13
Chapter 5: MegaRAID Controller Firmware Update Procedures
5-2 Flashing Firmware Using MegaRAID Storage
Manager
You need the MegaRAID Storage Manager software and ROM file (smc3108.rom)
to flash the MegaRAID firmware. Follow the steps below to use the MegaRAID
Storage Manager software on the following platforms: Micorsoft Windows operating
system and Linux operating system.
1. Open the MegaRAID Storage Manager application.
2. Right-click on the Avago 3108 controller to be updated, and select the Update
Controller Firmware menu option as shown below.
MegaRAID Storage Manager Screen on a Microsoft Windows Operating System

Page: 30

5-14
AOC-S3108L-H8iR Add-on Card User’s Manual
MegaRAID Storage Manager Screen on a Linux Operating System

Page: 31

5-15
Chapter 5: MegaRAID Controller Firmware Update Procedures
3. Press the Browse button to search for new firmware.
4. Select the new MegaRAID controller firmware as shown below.
5. Click OK to continue.
MegaRAID Storage Manager Screen on a Linux Operating System
MegaRAID Storage Manager Screen on a Microsoft Windows Operating System

Page: 32

5-16
AOC-S3108L-H8iR Add-on Card User’s Manual
6. Check Confirm in the dialog box and click Yes to continue, as shown below.
MegaRAID Storage Manager Screen on a Linux Operating System
MegaRAID Storage Manager Screen on a Microsoft Windows Operating System

Page: 33

5-17
Chapter 5: MegaRAID Controller Firmware Update Procedures
7. Do not reboot the system until the following screen displays.
8. Click OK once the firmware update is completed as shown below.
MegaRAID Storage Manager Screen on a Microsoft Windows Operating System
MegaRAID Storage Manager Screen on a Linux Operating System

Page: 34

5-18
AOC-S3108L-H8iR Add-on Card User’s Manual
9. Reboot the system and check the firmware version using the MegaRAID Storage
Manager application as shown below.
MegaRAID Storage Manager Screen on a Linux Operating System
MegaRAID Storage Manager Screen on a Microsoft Windows Operating System

Page: 35

6-1
Chapter 6: CacheCade Configuration
Chapter 6
MegaRAID CacheCade Configuration
This chapter provides instructions on how to configure MegaRAID CacheCade set-
tings in the Windows environment. Please refer to our website at www.supermicro.
com for information on firmware/utilities downloads.
6-1 Enabling MegaRAID CacheCade Support
Minimum System Configuration Requirements
You will need to have the following items pre-installed in your system before con-
figuring MegaRAID CacheCade settings.
1. Minimum of two hard drives
2. AOC-S3108L-H8iR add-on card
3. A PCI-E add-on card
4. Avago S3108 MegaRAID utility
5. A license key for MegaRAID CacheCade (to be purchased from Supermicro)

Page: 36

6-2
AOC-S3108L-H8iR Add-on Card User’s Guide
CacheCade Key Activation
The following section provides instructions on how to activate your CacheCade key
for proper MegaRAID CacheCade support.
1. From the MegaRAID Storage Manager menu, select Dashboard by clicking
on it.
2. Double-click on Manage MegaRAID Adanced Software Options as shown
below.
3. When the following screen displays, click MegaRAID CacheCAD Pro 2.0 to
select it, and click on Activate to enable CacheCAD support as shown below.
4.
5. When

Page: 37

6-3
Chapter 6: CacheCade Configuration
4. When the following screen displays, click on the radio button «Enter an
Activation Key» and then enter your Activation Key in the field provided as
shown below.

Page: 38

6-4
AOC-S3108L-H8iR Add-on Card User’s Guide
6-2 Configuring the CacheCade RAID Settings and
Creating a Drive Group
To configure MegaCacheCade settings, please follow the instructions below.
1. From the MegaRAID Storage Manager menu, select Physical by clicking on
it.
2. From the pull-down menu, select AVAGO 3108 MegaRAID by clicking on it.
3. Click on Properties to invoke the pull-down submenu.
1
2
3
4

Page: 39

6-5
Chapter 6: CacheCade Configuration
4. From the Properties pull-down submenu, select Create CacheCade™ — SSD
Caching by clicking on it.
5. When the following screen displays, click on Select to select the RAID setting
to configure for your HDDs.
6. Select your desired RAID setting to the hard drive you want to configure.
7. Click on Drive to invoke the pull-down submenu. From the pull-down sub-
menu, select the hard drives you want to configure the RAID setting.
8. With the desired hard drive selected, click on the Add button to add the
selected hard drive to your drive group list.
9. With all hard drives selected, click Next to create a CacheCade drive group.
10. To remove a hard drive from the selected drive group, select the drive you
want to remove and click on Remove to remove it from the list as shown
below.
9
10
8
5
6
7
9

Page: 40

6-6
AOC-S3108L-H8iR Add-on Card User’s Guide
11. After adding all HDDs you want to use to create a drive group to the list, click
on Create Drive Group to create a CacheCade drive group as shown below.
11
12
12. From the pull-down submenu, select the RAID setting you want to configure
and click Next to assign the selected RAID setting to all HDDs included in the
drive group list.
12

Page: 41

6-7
Chapter 6: CacheCade Configuration
6-3 Creating a CacheCade — SSD Caching Virtual Drive
To create a SSD caching virtual drive, please follow the instructions below.
1. From the MegaRAID Storage Manager menu, select Physical by clicking on
it.
2. From the pull-down menu, select AVAGO 3108 MegaRAID by clicking on it.
3. From the available drive list on the left, select the drive to create a virtual
drive by double-clicking on it.
4. Double-click on Create CacheCade™ — SSD Caching Drive Group.
5. Enter an SSD Caching VD (Virtual Drive) name in the field.
6. Select the desired Write Policy from the pop-up menu.
7. Click Create Virtual Drive to create a virtual drive.
8. Repeat the steps 4-6 and click Update Virtual Drive to create multiple virtual
drives to form a drive group.
9. Once you have created desired virtual drives, click Next.
1
2
3
9
8
4
5
6
7

Page: 42

6-8
AOC-S3108L-H8iR Add-on Card User’s Guide
10
11 12
10. To remove a virtual drive from a virtual drive group, select the drive to remove
and click on Remove Virtual Drive.
11. To cancel the deletion, click on Cancel.
12. To proceed to the next step to configure the virtual drive settings, click Next.
10
13. The following screen will display to indicate the status of the virtual drive that
you’ve just created. Review the status of the virtual drive.
14. After reviewing the status of the virtual drive as shown above, click Back to
make changes as needed, and click Finish to complete virtual drive creation.
14
13

Page: 43

6-9
Chapter 6: CacheCade Configuration
1
2
3
4 5
6-4 Configuring Virtual Drive Settings
To configure the settings for a virtual drive, please follow the instructions below.
1. From the MegaRAID Storage Manager menu, select Logical by clicking on it.
2. From the Virtual Drive(s) pull-down menu, select the Virtual Drive you want
to configure by clicking on it.
3. From the pop-up menu, select the setting you want to use by clicking on it.
4. A dialogue box will display to warn you that a setting of the selected virtual
drive will be changed. Click Confirm and Yes for the virtual drive to use the
new setting(s).
5. Click No to use the old setting.
4

Page: 44

6-10
AOC-S3108L-H8iR Add-on Card User’s Guide
6-5 Enabling SSD Caching Support on a Virtual Drive
To enable SSD Caching support for a virtual drive, please follow the instructions
below.
1. From the MegaRAID Storage Manager menu, select Logical by clicking on it.
2. From the Virtual Drive(s) pull-down menu, select the Virtual Drive for SSD
Caching support by clicking on it.
3. From the pop-up menu, click Enable SSD Caching to enable SSD Cach-
ing support. After SSD Caching support is enabled, you can use advanced
CacheCade settings on a selected virtual drive.
1
2
3

Page: 45

(Disclaimer Continued)
The products sold by Supermicro are not intended for and will not be used in life support systems,
medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com-
munication devices or other critical systems whose failure to perform be reasonably expected to result
in significant injury or loss of life or catastrophic property damage. Accordingly, Supermicro disclaims
any and all liability, and should buyer use or sell such products for use in such ultra-hazardous ap-
plications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend
and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.