Tsunami 8000 mp 8160 инструкция

  1. Manuals
  2. Brands
  3. Proxim Manuals
  4. Wireless Access Point
  5. Tsunami Multipoint MP-8160-SUA

Manuals and User Guides for Proxim Tsunami Multipoint MP-8160-SUA. We have 2 Proxim Tsunami Multipoint MP-8160-SUA manuals available for free PDF download: Hardware Installation Manual, Installation Manual

Proxim Tsunami Multipoint MP-8160-SUA Hardware Installation Manual

Proxim Tsunami Multipoint MP-8160-SUA Hardware Installation Manual (91 pages)

Point-to-point and Point-to-multipoint Product

Brand: Proxim
|
Category: Wireless Access Point
|
Size: 3.4 MB

Table of Contents
  • About this Guide

    6

  • Products Covered

    6

  • Related Documents

    7

  • Documentation Conventions

    8

  • Hardware Overview

    14

  • Product Package

    17

  • Installation Procedure

    19

  • Step 1: Plan for Installation

    19

  • Step 2: Choose a Location

    19

  • Step 3: Gather Required Tools

    20

  • Step 6: Assemble Mounting Hardware

    21

  • Step 7: Mount the Device

    22

  • Step 8: Plug in the Cables

    23

  • Step 9: Connect the Antenna

    24

  • Step 11: Ground the Unit

    25

  • Step 12: Power on the Device

    26

  • Step 13: View Leds

    26

  • Step 14: Align the Antenna

    27

  • Hardware Overview

    28

  • Step 9: Ground the Device

    33

  • Step 6: Assemble Mounting Hardware

    51

  • Step 7: Mount the Device

    52

  • Step 8: Plug in the Cables

    52

  • Step 9: Connect the Antenna

    53

  • Step 11: Ground the Unit

    54

  • Step 12: Power on the Device

    55

  • Hardware Overview

    58

  • Product Package

    61

  • Installation Procedure

    62

  • Step 1: Plan for Installation

    63

  • Step 2: Choose a Location

    63

  • Step 3: Gather Required Tools

    63

  • Step 7: Mount the Device

    66

  • Step 8: Plug in the Cables

    66

  • Step 12: Power on the Device

    69

  • Step 13: View Leds

    69

  • Hardware Overview

    72

  • Product Package

    74

  • Installation Procedure

    75

  • Step 5: Assemble the Cable

    76

  • Step 9: Ground the Device

    79

Advertisement

Proxim Tsunami Multipoint MP-8160-SUA Installation Manual

Proxim Tsunami Multipoint MP-8160-SUA Installation Manual (81 pages)

Tsunami 800 and 8000 Series (Point-to-point and Point-to-multipoint Products)

Brand: Proxim
|
Category: Wireless Access Point
|
Size: 2.95 MB

Table of Contents
  • About this Guide

    6

  • Products Covered

    6

  • Related Documents

    7

  • Documentation Conventions

    8

  • Hardware Overview

    14

  • Product Package

    17

  • Installation Procedure

    19

  • Step 1: Plan for Installation

    19

  • Step 2: Choose a Location

    19

  • Step 3: Gather Required Tools

    20

  • Step 6: Assemble Mounting Hardware

    21

  • Step 7: Mount the Device

    22

  • Step 8: Plug in the Cables

    23

  • Step 9: Connect the Antenna

    24

  • Step 11: Ground the Unit

    25

  • Step 12: Power on the Device

    26

  • Step 13: View Leds

    26

  • Step 14: Align the Antenna

    27

  • Hardware Overview

    28

  • Step 9: Ground the Device

    33

  • Step 6: Assemble Mounting Hardware

    51

  • Step 7: Mount the Device

    52

  • Step 8: Plug in the Cables

    52

  • Step 9: Connect the Antenna

    53

  • Step 11: Ground the Unit

    54

  • Step 12: Power on the Device

    55

  • Hardware Overview

    58

  • Product Package

    61

  • Installation Procedure

    62

  • Step 1: Plan for Installation

    63

  • Step 2: Choose a Location

    63

  • Step 3: Gather Required Tools

    63

  • Step 7: Mount the Device

    66

  • Step 8: Plug in the Cables

    66

  • Step 12: Power on the Device

    69

  • Step 13: View Leds

    69

  • Step 5: Assemble the Cable

    76

Advertisement

Related Products

  • Proxim Tsunami Multipoint MP-8100-BSU

  • Proxim Tsunami Multipoint MP-8100-SUA

  • Proxim Tsunami Multipoint MP-8150-SUR

  • Proxim Tsunami Multipoint MP-8150-SUR-100

  • Proxim Tsunami Multipoint MP-8150-CPE

  • Proxim Tsunami Multipoint MP-8160-BSU

  • Proxim Tsunami Multipoint MP-8160-BS9

  • proxim Tsunami MP-8100 Series

  • Proxim Tsunami Multipoint MP-825-CPE-50

  • Proxim Tsunami Multipoint MP-8250-SUR

Proxim Categories

Wireless Access Point

Network Router
Network Router

Network Hardware

Adapter

Antenna

More Proxim Manuals

  1. Manuals
  2. Brands
  3. Proxim Manuals
  4. Wireless Access Point
  5. Tsunami Multipoint MP-8160-BSU

Manuals and User Guides for Proxim Tsunami Multipoint MP-8160-BSU. We have 2 Proxim Tsunami Multipoint MP-8160-BSU manuals available for free PDF download: Hardware Installation Manual, Installation Manual

Proxim Tsunami Multipoint MP-8160-BSU Hardware Installation Manual

Proxim Tsunami Multipoint MP-8160-BSU Hardware Installation Manual (91 pages)

Point-to-point and Point-to-multipoint Product

Brand: Proxim
|
Category: Wireless Access Point
|
Size: 3.4 MB

Table of Contents
  • About this Guide

    6

  • Products Covered

    6

  • Related Documents

    7

  • Documentation Conventions

    8

  • Hardware Overview

    14

  • Product Package

    17

  • Installation Procedure

    19

  • Step 1: Plan for Installation

    19

  • Step 2: Choose a Location

    19

  • Step 3: Gather Required Tools

    20

  • Step 6: Assemble Mounting Hardware

    21

  • Step 7: Mount the Device

    22

  • Step 8: Plug in the Cables

    23

  • Step 9: Connect the Antenna

    24

  • Step 11: Ground the Unit

    25

  • Step 12: Power on the Device

    26

  • Step 13: View Leds

    26

  • Step 14: Align the Antenna

    27

  • Hardware Overview

    28

  • Step 9: Ground the Device

    33

  • Step 6: Assemble Mounting Hardware

    51

  • Step 7: Mount the Device

    52

  • Step 8: Plug in the Cables

    52

  • Step 9: Connect the Antenna

    53

  • Step 11: Ground the Unit

    54

  • Step 12: Power on the Device

    55

  • Hardware Overview

    58

  • Product Package

    61

  • Installation Procedure

    62

  • Step 1: Plan for Installation

    63

  • Step 2: Choose a Location

    63

  • Step 3: Gather Required Tools

    63

  • Step 7: Mount the Device

    66

  • Step 8: Plug in the Cables

    66

  • Step 12: Power on the Device

    69

  • Step 13: View Leds

    69

  • Hardware Overview

    72

  • Product Package

    74

  • Installation Procedure

    75

  • Step 5: Assemble the Cable

    76

  • Step 9: Ground the Device

    79

Advertisement

Proxim Tsunami Multipoint MP-8160-BSU Installation Manual

Proxim Tsunami Multipoint MP-8160-BSU Installation Manual (81 pages)

Tsunami 800 and 8000 Series (Point-to-point and Point-to-multipoint Products)

Brand: Proxim
|
Category: Wireless Access Point
|
Size: 2.95 MB

Table of Contents
  • About this Guide

    6

  • Products Covered

    6

  • Related Documents

    7

  • Documentation Conventions

    8

  • Hardware Overview

    14

  • Product Package

    17

  • Installation Procedure

    19

  • Step 1: Plan for Installation

    19

  • Step 2: Choose a Location

    19

  • Step 3: Gather Required Tools

    20

  • Step 6: Assemble Mounting Hardware

    21

  • Step 7: Mount the Device

    22

  • Step 8: Plug in the Cables

    23

  • Step 9: Connect the Antenna

    24

  • Step 11: Ground the Unit

    25

  • Step 12: Power on the Device

    26

  • Step 13: View Leds

    26

  • Step 14: Align the Antenna

    27

  • Hardware Overview

    28

  • Step 9: Ground the Device

    33

  • Step 6: Assemble Mounting Hardware

    51

  • Step 7: Mount the Device

    52

  • Step 8: Plug in the Cables

    52

  • Step 9: Connect the Antenna

    53

  • Step 11: Ground the Unit

    54

  • Step 12: Power on the Device

    55

  • Hardware Overview

    58

  • Product Package

    61

  • Installation Procedure

    62

  • Step 1: Plan for Installation

    63

  • Step 2: Choose a Location

    63

  • Step 3: Gather Required Tools

    63

  • Step 7: Mount the Device

    66

  • Step 8: Plug in the Cables

    66

  • Step 12: Power on the Device

    69

  • Step 13: View Leds

    69

  • Step 5: Assemble the Cable

    76

Advertisement

Related Products

  • Proxim Tsunami Multipoint MP-8100-BSU

  • Proxim Tsunami Multipoint MP-8100-SUA

  • Proxim Tsunami Multipoint MP-8150-SUR

  • Proxim Tsunami Multipoint MP-8150-SUR-100

  • Proxim Tsunami Multipoint MP-8150-CPE

  • Proxim Tsunami Multipoint MP-8160-BS9

  • Proxim Tsunami Multipoint MP-8160-SUA

  • proxim Tsunami MP-8100 Series

  • Proxim Tsunami Multipoint MP-826-CPE-50

  • Proxim Tsunami Multipoint MP-825-CPE-100

Proxim Categories

Wireless Access Point

Network Router
Network Router

Network Hardware

Adapter

Antenna

More Proxim Manuals

Гейзер-Телеком

ООО «Гейзер-Телеком»+7 (495) 784 — 63 — 77
info@geyser-telecom.ru
105118, Москва,ул. Вольная, д.13

 
  • РАСПРОДАЖА
  • Оборудование радиорелейной связи
  • Оборудование беспроводного широкополосного доступа (БШД)
  • Оборудование LTE
  • Оборудование профессиональной радиосвязи
 

Оборудование Tsunami MP-81XXTsunami MP-8100/81600 — новейшее решение «точка — много точек» для сетей различного масштаба. Используя преимущества инновационных технологий OFDM, MIMO и частный протокол WORP от Proxim, система Tsunami MP-8100/8160 превосходит требования, предъявляемые союзом ITU к сетям 4G, наряду с возможностью работы в условиях непрямой видимости и поддержкой широкого частотного диапазона. Вместе с повышенной производительностью, универсальностью частотного диапазона и с поддержкой качества обслуживания (QoS) при предоставлении услуг голосовой связи, передачи видео и данных, MP-8100/8160 удовлетворяет требования сервис-провайдеров, госорганизаций и корпоративного сектора по созданию беспроводных сетей.

Поддержка канальной скорости 300 Мбит/с делает Tsunami MP-8100/8160 идеальным решением последней мили для широкополосных беспроводных сетей передачи данных (ШБПД) и видеонаблюдения. Наличие двух портов гигабит Ethernet с возможностью подачи питания РоЕ, делают Tsunami MP-8100/8160 первым в индустрии решениями, позволяющим достаточно просто подключать видеокамеры или другие устройства, с питанием по РоЕ без применения дополнительных устройств

Высокая производительность

  • Решение для фиксированных сетей «точка — много точек» с канальной скоростью 300 Мбит/с и реальной производительностью для TCP/UDP трафика более чем в 100 Мбит/с
  • Оборудование с двумя интерфейсами гигабит Ethernet обеспечивает большую производительность по сравнению с аналогами, имеющими только 10/100 Ethernet порты
  • Использование частного протокола WORP обеспечивает надежную высокую производительность оборудования при больших нагрузках трафиком

Оборудование Tsunami MP-8100Расширенные возможности

  • Использование технологии OFDM и режима MIMO 3×3 (MP-8100) и MIMO 2×2 (MP-8160) позволяет оборудованию работать в условиях отсутствия прямой видимости, поддерживая надежное качество соединения
  • Компактный форм-фактор и необходимый набор аксессуаров в комплекте поставки позволяет максимально облегчить процесс инсталляции оборудования
  • Наличие двух интерфейсов гигабит Ethernet с поддержкой питания РоЕ позволяют запитывать локально подключаемые камеры видеонаблюдения или Wi-Fi точки доступа
  • Возможность создания многоуровневых классов обслуживания (QoS)

Оборудование Tsunami MP-8160Широкий диапазон частот

  • Поддерживаются диапазон частот, регламентированный решениями ГКРЧ
  • Возможность работы в диапазоне 2.3 — 2.5 ГГц и
    4.9 — 6.0 ГГц (MP-8100); 5.9 — 6.425 ГГц (MP-8160)

Безопасность уровня операторского класса

  • Возможность формирования многоуровневой безопасности для наибольшей защиты беспроводных соединений
  • Использование частного протокола (WORP), исключает возможность перехвата в радио, и наличие безопасных интерфейсов SSL, SSH и SNMPv3
  • Поддержка шифрования AES, списков доступа по MAC или IP адресам, а также фильтрация трафика значительно повышают безопасность сети

Технические характеристики

  Tsunami MP-8100 Tsunami MP-8160
ИНТЕРФЕЙСЫ  
Ethernet Два порта auto MDI-X RJ45 Gigabit Ethernet
Порт #1 для передачи данных с получением питания по PoE
Порт #2 для передачи данных с поддержкой питания по PoE на выходе (802.3af)
Два порта auto MDI-X RJ45 10/100/1000Mbps Ethernet
Порт #1 для передачи данных с получением питания по PoE
Порт #2 для передачи данных с поддержкой питания по PoE на выходе (802.3af)
Радиоинтерфейс Протокол WORP (Wireless Outdoor Router Protocol)
ПАРАМЕТРЫ РАДИО  
MIMO MIMO 3×3 (Multiple Input Multiple Output) MIMO 2×2
Модуляция OFDM с поддержкой BPSK, QPSK, QAM16, QAM64
Диапазон частот 2.3 – 2.5 ГГц
4.9 – 6.0 ГГц (в зависимости от локальных требований)
5.9-6.4 ГГц
Ширина канала 40 МГц, 20 МГц , 10 МГц , 5 МГц
Скорость передачи данных MCS 0 to 15 для режима High Throughput (6.5 – 300 Мбит/с)
BPSK, QPSK, 16-QAM и 64-QAM для режима Legacy (6 — 54 Мбит/с)
MCS 0 to 15 для режима High Throughput (6.5 – 300 Мбит/с)
ТХ мощность до 18 дБм на порту антенны до 26 дБм
Контроль мощности 0 – 18 дБ с шагом 1 дБ с шагом 0,5 дБ
Чувствительность приемника (BER=10-6)
Ширина Канала 40 МГц 20 МГц
MCS 0 / MCS 8 -87 дБм -93 дБм
MCS 7 -71 дБм -75 дБм
MCS 15 -69 дБм -71 дБм
АНТЕННЫ два разъёма N-типа с встроенной молниезащитой для подключения антенн
MP-8150-SUR имеет интегрированную кросс-поляризационную (+/-45) антенну MIMO 2×2 с усилением 21 дБи
два разъёма N-типа с встроенной молниезащитой для подключения антенн
УПРАВЛЕНИЕ  
Локальное Серийный интерфейс RS-232
Дистанционное Telnet и SSH, Web-интерфейс и SSL, TFTP, SNMPv3
SNMP SNMP v1-v2c-v3, RFC-1213, RFC-1215, RFC-2790, RFC-2571, RFC-3412, RFC-3414, Private MIB
СЕТЬ  
Основные функции DHCP Server & relay, NAT with Std ALGs, Bridging, Routing, Syslog, SNTP
VLAN Поддержка 802.1Q: VLAN управления.
Режимы — Transparent, Access и Trunk
QOS
Контроль ассиметричности полосы Контроль Uplink и Downlink CIR «committed information rate» на сервисный поток Контроль Uplink и Downlink MIR «maximum information rate» на сервисный поток
Классификация пакетов 802.1D/802.1Q/802.1p priority, IPTOS, VLAN ID, IP source/destination address, source/destination port, Ethernet source/destination address, IP protocol, and Ethertype
Типы очередей Best Effort, Real Time Polling Services
ВНЕШНЯЯ СРЕДА  
Рабочая температура от -40° до +60°C
Влажность Максимальная относительная влажность 100%
ФИЗИЧЕСКИЕ ПАРАМЕТРЫ  
Размеры 267 x 267 x 83 мм
Вес 3,3 кг
  • Доступ «Последней мили» Альтернатива проводным решениям DSL для частного сектора или выделенных каналов Е1 или Ethernet для бизнес сектора
  • Безопасность и видеонаблюдение Подключение камер с высоким разрешением для наблюдения за городскими улицами, в аэропортах, на автомагистралях, железной дороге, в морских портах, производственных и складских помещениях
  • Городские сети Безопасные и надежные соединения между зданиями
  • Службы быстрого реагирования Быстрая организация сетей передачи данных для экстренных служб
  • Корпоративные сети Расширение существующей сети предприятия за счет подключения удаленных офисов, складов и других объектов по беспроводным каналам
Контактная информация:
Группа разработки технических решений
Телефон: +7 (495) 784-63-77
E-mail: wireless@g-tl.ru
 
  • Вся активность

Tsunami MP-8160 поделитесь опытом использования.

Join the conversation

You can post now and register later.

If you have an account, sign in now to post with your account.

[Page 1] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series (Point-to-point and Point-to-multipoint Products) Software Management Guide Products Covered —> Tsunami ® Multipoint — MP-820-BSU-100 — MP-8100-BSU — MP-82…

[Page 2] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 2 Copyright © 2013 Proxim Wireless Corporation, Milpitas, CA. All rights reserved. Covered by one or more of the following U.S. patents: 5,231,634; 5,875,179; 6,00…

[Page 3] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 3

[Page 4] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 4

[Page 5] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 5

[Page 6] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 6

[Page 7] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 7

[Page 8] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 8

[Page 9] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 9

[Page 10] Proxim Tsunami 8000 series

Preface Tsunami ® 800 & 8000 Series — Software Management Guide 10 Preface This chapter contains information on the following: About this Guide This guide gives a jump-start working knowledge of the Tsunami ® 800 and 8000 produ…

[Page 11] Proxim Tsunami 8000 series

Preface Tsunami ® 800 & 8000 Series — Software Management Guide 11 Audience The intended audience for this guide is the network administrators who install and/or manage the device. Prerequisites The reader of this document should have working…

[Page 12] Proxim Tsunami 8000 series

Preface Tsunami ® 800 & 8000 Series — Software Management Guide 12 Documentation Conventions ScreenShots This guide uses screenshots to explain the method to configure, manage and monitor the device by using Web Interface. Based on your d…

[Page 13] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 13 Overview This chapter contains information on the following: 1.1 About Tsunami ® 800 and 8000 Products Proxim’s Tsunami ® 800 and 8000 product series, consists of point-to-point …

[Page 14] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 14 MP-8250-BS9 The MP-8250 Base Station unit comes with a high power 2×2 MIMO radio and 16 dBi integrated 90° sector antenna that operates in 4.900 – 5.925 GHz freq…

[Page 15] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 15 MP-825-CPE-50 The MP-825 Customer Premises Equipment comes with a 2×2 MIMO radio and 15 dBi integrated dual-polarized panel antenna that operates in 5.15 — 5.925 …

[Page 16] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 16 QB-8151-LNK A pair of QB-8151-EPR devices form a link. The QB-8151-EPR device comes with a 2×2 MIMO radio, 21 dBi integrated dual-polarized panel antenna that …

[Page 17] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 17 QB-825-LNK-50 + A pair of QB-825-EPR-50 + devices form a link.

[Page 18] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 18 1.2 Wireless Network Topology 1.2.1 Point-to-Multipoint (PTMP) Point-to-multipoint is a wireless network that has a central communication device such as a Base Station Unit (…

[Page 19] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 19 Last Mile Access: Competitive broadband service access alternative to Digital Subscriber Line (DSL) or cable for residences and T1 or Ethernet for businesses. …

[Page 20] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 20 Metropolitan Area Network: Secure and reliable connectivity between city buildings. Enterprise Campus Connectivity: Extend the main network to remote offices, wareh…

[Page 21] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 21 Wireless Intelligent Transport System (ITS): Increases the traffic efficiency and reduces the commuting time in cities and metropolitan areas. Roaming: A mobile devi…

[Page 22] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 22 Offshore Communications: Establishes connectivity between seashore and the ships that are nearing the port locations, or connectivity between off-shore oil rigs …

[Page 23] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 23 Given below are the deployment scenarios, where Proxim’s point-to-point devices are recommended. The proxim devices used in the deployment images are commonly…

[Page 24] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 24 Repeater: Extends distance or overcomes path blockage by adding point-to-point hops. High-bandwidth Last Mile Access: Delivers Transparent LAN Services (TLS) to corporate par…

[Page 25] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 25 Leased Line Redundancy: Eliminates recurring DS-3 leased line charges with one time installation charge of a QuickBridge link. Inter-POP Redundancy: Avoids dow…

[Page 26] Proxim Tsunami 8000 series

Overview Tsunami ® 800 & 8000 Series — Software Management Guide 26 Quality of Service: WORP ensures that the most important data arrives with priority by differentiating between priorities of traffic as defined in the profiles…

[Page 27] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 27 Management and Monitoring Capabilities A Network administrator can use the following interfaces to configure, manage and monitor the device. 2.1 Web (HTTP/HTTPS) Interface The Web …

[Page 28] Proxim Tsunami 8000 series

Management and Monitoring Capabilities Tsunami ® 800 & 8000 Series — Software Management Guide 28 If using RS-232 cable, verify the following information in the HyperTerminal serial port setup: : When using Windows 7, use a Terminal Emulator …

[Page 29] Proxim Tsunami 8000 series

Management and Monitoring Capabilities Tsunami ® 800 & 8000 Series — Software Management Guide 29 The PXM MIB files are available on the Proxim support site at . The enterprise MIB (PXM-SNMP.mib) defines the Read and Read/Write objects …

[Page 30] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 30 Device Initialization This chapter contains information on the following: 3.1 Initialization Once the device installation completes, access the device either through Web Int…

[Page 31] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 31 Switch between the network adapters, if there are multiple network adapters in the Personal Computer : IPv6 is supported only by ScanTool v3.0.1 and higher vers…

[Page 32] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 32 This screen contains the following device information: MAC Address System Name IP Address Uptime System Description: The system description comprises the followi…

[Page 33] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 33 Figure 3-4 Modifying Device’s IP Address (IPv6) 1. Select the IP Address Type as static/dynamic for IPv4 and as static/dynamic/auto for IPv6 Static: When set t…

[Page 34] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 34 Figure 3-5 Login Screen Based on the access credentials, two types of users can access the device. They are, 1. Administrator User: The Administrator user admini…

[Page 35] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 35 In the Internet Explorer, to get best results, click on Tools > Internet Options > General. Click Settings in the Browsing History and select “Every visi…

[Page 36] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 36 3.2.2 COMMIT COMMIT operation is used to apply the configuration changes onto the device. When changes are made to the configuration parameters…

[Page 37] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 37 3.2.3 REBOOT Reboot operation is required for any change in the key parameters to take effect. For example, settings such as configuring the Radio Mode, IP Addre…

[Page 38] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 38 Maximum Number of SUs (per BSU) MP-8100-BSU (rev 1 to rev 6) —> 100 MP-8100-BSU (rev 7 and above) —> 250 MP-8160-BSU —> 250 MP-8160-BS9 —> 250 MP…

[Page 39] Proxim Tsunami 8000 series

Device Initialization Tsunami ® 800 & 8000 Series — Software Management Guide 39 IGMP Snooping Disabled Disabled RIP Disabled Disabled NAT Disabled Disabled PPPoE Client Not Applicable Disabled in SU Mode Not Applicable in End Point B HTTP M…

[Page 40] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 40 Basic Configuration The BASIC CONFIGURATION tab provides a one-place access to a minimum set of configuration parameters to quickly set up a Point-to-point or Point-to-multipoint netwo…

[Page 41] Proxim Tsunami 8000 series

Basic Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 41 Figure 4-2 Basic Configuration (SU)

[Page 42] Proxim Tsunami 8000 series

Basic Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 42 Figure 4-3 Basic Configuration (End Point A)

[Page 43] Proxim Tsunami 8000 series

Basic Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 43 Figure 4-4 Basic Configuration (End Point B) Below is the table which explains basic parameters and the method to configure the configurable parameter(s): Paramete…

[Page 44] Proxim Tsunami 8000 series

Basic Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 44 Frequency Domain This parameter specifies the country of operation, permitted frequency bands and regulatory rules for a particular country or domain. When the fr…

[Page 45] Proxim Tsunami 8000 series

Basic Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 45 Auto Channel Selection (ACS) Enables a device to select the best channel for data transmission on the wireless medium, with less interference. By default, ACS is…

[Page 46] Proxim Tsunami 8000 series

Basic Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 46 After configuring the required parameters, click OK and then COMMIT. : Reboot the device, if any of the parameters with an asterisk symbol are configured. Legacy M…

[Page 47] Proxim Tsunami 8000 series

Tsunami ® 800 & 8000 Series — Software Management Guide 47 Advanced Configuration The ADVANCED CONFIGURATION tab provides a means to configure the following advanced features of the device: : Recommended characters for the name field are A-Z …

[Page 48] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 48 5.1 System The System tab enables to configure system specific information. To configure system specific parameters, navigate to ADVANCED CONFIGURATION > Sy…

[Page 49] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 49 Active Network Mode A change in the network mode (either Bridge or Routing mode) is applied on the device only when the device is rebooted. So, when the netwo…

[Page 50] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 50 Maximum MTU (Maximum Transmission Unit) Given below are the devices and their corresponding MTU configurable range: Maximum Frame Size = Configured MTU + Ethe…

[Page 51] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 51 After configuring the required parameters, click OK, COMMIT and then REBOOT. : For more details regarding LED display and RSSI LED behavior, refer . 5.2 Networ…

[Page 52] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 52 : IPv6 address is supported only in bridge mode. 5.2.1.1 Bridge Mode 5.2.1.1.1 IP Configuration (IPv4 Only) To configure the IP parameters of the device when op…

[Page 53] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 53 After configuring the required parameters, click OK, COMMIT and then REBOOT. 5.2.1.1.2 IP Configuration (IPv4 and IPv6) To configure the IP parameters of the d…

[Page 54] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 54 Figure 5-5 IPv6 Configuration (Bridge Mode) Given below is the table which explains the method to configure IP parameters in Bridge mode: Parameter Description …

[Page 55] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 55 5.2.1.1.3 DNS DNS server is used to resolve/translate a domain name into an IP address. To configure Primary and Secondary DNS IP parameters of the d…

[Page 56] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 56 Figure 5-6 DNS Configuration (Bridge Mode) 5.2.1.2 Routing Mode : A device (BSU/SU) will act as a DHCP Client only when configured in Bridge Mode. In Routing …

[Page 57] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 57 Figure 5-7 IP Configuration (Routing Mode) Given below is the table which explains the method to configure IP parameters in Routing mode: Parameter Description …

[Page 58] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 58 5.2.1.2.1 DNS To configure the IP parameters of the device when operating in Routing mode, navigate to ADVANCED CONFIGURATION > Network > IP Configuration…

[Page 59] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 59 : In routing mode, the Primary and Secondary IP Address cannot be configured as IPv6 addresses. After configuring the required parameters, click OK, COMMIT and…

[Page 60] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 60 Figure 5-9 IP Configuration (Routing Mode with PPPoE Client Enabled) Given below is the table which explains the method to configure IP parameters in Routing mo…

[Page 61] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 61 Wireless (PPPoE) Address Type This parameter specifies whether the wireless interface parameters are to be configured through PPPoE server or to be assigned st…

[Page 62] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 62 5.2.1.3.1 DNS To configure the IP parameters of the device when operating in Routing mode, navigate to ADVANCED CONFIGURATION > Network > IP Configuration…

[Page 63] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 63 After configuring the required parameters, click OK, COMMIT and then REBOOT. 5.2.2 Static Route Table : Applicable only in routing mode. The Static Route Table…

[Page 64] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 64 5.2.2.1 Adding Static Route Entries Click Add in the Static Route Table screen.The following Static Route Table Add Row screen appears: Figure 5-12 Static Route…

[Page 65] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 65 : When NAT is enabled, the network on the wireless side of the device is considered public and the network on the Ethernet side is considered private. When NA…

[Page 66] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 66 : To enable Dynamic NAT, set the NAT Status to Enable. To enable Static NAT, set the NAT Status to Enable and the Port Forwarding Status to Enable. NAT uses th…

[Page 67] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 67 5.2.3.1 Supported Session Protocols Certain applications require an Application Level Gateway (ALG) to provide the required transparency for an a…

[Page 68] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 68 Figure 5-15 RIP By default, RIP is not enabled on the device. To enabled, select Enable and click OK. The RIP screen is updated with the following tabulate…

[Page 69] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 69 5.2.5 PPPoE End Point (SU Only) Proxim’s SU devices support Point-to-Point Protocol over Ethernet (PPPoE) which is a network protocol for transmitting PPP fra…

[Page 70] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 70 Echo Interval and Echo Failure to detect server unavailability MPPE with stateful and stateless mode aligned with 40/56/128 bit encryption To configure PPPoE fe…

[Page 71] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 71 5. Given below is the table which explains PPPoE client parameters and the method to configure the configurable parameter(s): Parameter Descript…

[Page 72] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 72 LCP Echo Failure This parameter indicates the maximum number of consecutive failures to receive the LCP echo-reply to consider the connection to be down. To co…

[Page 73] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 73 MPPE Status : MPPE Status parameter is applicable only when the Authentication Protocol is configured as “MSCHAP v2”. Microsoft Point-to-Point Encryption (…

[Page 74] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 74 6. After configuring the required parameters, click OK and then COMMIT. Reboot the device, if you have changed the PPPoE Status configuration. 5.2.6 IP over IP …

[Page 75] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 75 The following figure shows an IP tunnel configuration using two end points. Figure 5-19 An Example: Tunnel Configuration Lets say that the Computer with an IP…

[Page 76] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 76 By following the steps below, the tunnel is automatically established. 1. Create a tunnel (Refer to ) To create a tunnel as given in , do the following: SU1 …

[Page 77] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 77 5. Click Add, to create a new tunnel interface. The following Tunneling Table Add Row screen appears: Figure 5-22 Adding a new Tunnel Interface 6. Given below i…

[Page 78] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 78 : You can create a maximum of 16 tunnels. The Maximum Transmission Unit (MTU) of the tunnel interface depends on the underlying interface. It is advised that bo…

[Page 79] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 79 Given below is the table which explains Basic Ethernet parameters and the method to configure the configurable parameter(s): Parameter Descripti…

[Page 80] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 80 After configuring the required parameters, click OK and then COMMIT. Reboot the device, if you have changed the Admin Status configuration. 5.3.2 Advanced Confi…

[Page 81] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 81 Figure 5-25 Advanced Ethernet Configuration Given below is the table which explains Advanced Ethernet parameters and the method to configure the …

[Page 82] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 82 5.4.1 Link Profiles The Link Profiles feature enables you to create wireless profiles on a per link basis. These link profiles help to determine the wireless t…

[Page 83] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 83 The default profile can be modified to suit the network requirements. However, it is possible that one profile may not be able to satisfy the requirements of al…

[Page 84] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 84 Figure 5-28 Edit a Link Profile (Basic) 5.4.1.2.1 Basic Under Basic screen, you can configure and view the following parameters. Parameter Description Profile …

[Page 85] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 85 Data Streams Select the data stream as either Auto, Single or Dual. Dual Stream: Select Dual, for higher throughput. Single Stream: Select Single, for reliabil…

[Page 86] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 86 After configuring the required parameters, click OK and then COMMIT. 5.4.1.2.2 Advanced Under Advanced screen, you can configure and view the following paramet…

[Page 87] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 87 Figure 5-29 Edit a Link Profile (Advanced) Parameter Description DDRS Min Data Rate and DDRS Max Data Rate Represents the minimum and maximum data rate for DDR…

[Page 88] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 88 DDRS Rate Incr RTX Threshold Represents a threshold for the percentage of retransmissions, below which the rate can be increased. By default, it is set to 25%…

[Page 89] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 89 Click Local SNR-Table, to view the optimal SNR values that are exchanged with the peer for optimal throughput. Figure 5-30 An Example — SNR Information ATPC Upp…

[Page 90] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 90 After configuring the required parameters, click OK and then COMMIT. 5.4.2 Wireless Outdoor Router Protocol (WORP) WORP is protocol, designed by Proxim that pro…

[Page 91] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 91 Figure 5-32 WORP Configuration (SU) Given below is the table which explains WORP parameters and the method to configure the configurable parameter(s): Parameter…

[Page 92] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 92 Secondary BSU Name This parameter serves as a Secondary / Redundant BSU for the SU and helps in reducing the network outage in the case of Primary BSU failure….

[Page 93] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 93 Max SUs Represents the maximum number of SUs that can register with a BSU. Given below are the base stations and the maximum number of subscribers supported by…

[Page 94] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 94 Multi Frame Bursting To achieve higher throughput, WORP protocol allows the transmitter or receiver to send multiple data frames in sequence without waiting fo…

[Page 95] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 95 After configuring the required parameters, click OK and then COMMIT. Security Profile Name The Security Profile Name represents the encryption method used to en…

[Page 96] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 96 : Modifying any of the WORP parameters result in temporary loss of connectivity between the transmitter and receiver. MAC ACL Status and RADIUS MAC ACL Status …

[Page 97] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 97 Figure 5-34 Wireless Interface Properties (SU) The Wireless Interface Properties screen is classified under two categories: Properties and MIMO. 5.4.3.0.1 Prope…

[Page 98] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 98 Channel Offset : Applicable only to MP-8160-BSU; MP-8160-BS9; MP-8160-SUA; MP-8150-CPE; MP-8160-CPE-A100; MP-825-CPE-50; MP-820-BSU-100; MP-820-SUA-50 + ; MP-…

[Page 99] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 99 Satellite Density Satellite Density setting helps to achieve maximum bandwidth in a wireless network. It influences the receive sensitivity of the radio interf…

[Page 100] Proxim Tsunami 8000 series

Advanced Configuration Tsunami ® 800 & 8000 Series — Software Management Guide 100 Max EIRP The maximum effective power that a radio antenna is allowed to radiate as per the regulatory standard. By default, the maximum EIRP is set as per the…

Понравилась статья? Поделить с друзьями:
  • Tsd navigator инструкция на русском
  • Tsc tdp 225 инструкция на русском
  • Tsa lock инструкция к чемодану
  • Tsa 325 nt инструкция geze
  • Ts78 детектор скрытой проводки инструкция