Contents
-
Table of Contents
-
Bookmarks
Quick Links
CL5000J Series
User’s Manual
Rev 2007.09.06
1
Related Manuals for CAS CL5000J Series
Summary of Contents for CAS CL5000J Series
-
Page 1
CL5000J Series User’s Manual Rev 2007.09.06… -
Page 2: Table Of Contents
Table of Contents 1. GENERAL ………………………….. 5 1.1 PRECAUTIONS ……………………….5 1.2 INTRODUCTIONS ……………………… 7 1.3 SPECIFICATIONS ……………………… 8 1.4 NAME AND FUNCTIONS ……………………10 1.5 Basic set-up ……………………….12 1.6 SYMBOLS ………………………… 13 1.7 KEY FUNCTIONS ……………………..13 1.8 Installation of the Label Roll …………………… 16 2.
-
Page 3
2.7.5 Sensor Calibration (Menu code 1733) ………………50 2.7.6 Sensor & Motor (Menu code 1734) ………………50 2.7.7 Print Intensity (Menu code 1735) ………………… 51 2.7.8 Adjust Feed Length (Menu code 1736) ………………51 2.7.9 Label Preprint (Menu code 1737) ………………… 51 2.7.10 Printer Initialize (Menu code 1738) ……………… -
Page 4
3.3 Tare …………………………. 61 3.3.1 Manual Tare Entry ……………………62 3.3.2 Weighed Tare Entry ……………………62 3.3.3 How to Clear Tare ……………………63 3.3.4 Preset Tare ……………………..63 3.3.5 Successive Tare ……………………. 63 3.3.6 Tare Override ……………………..64 3.4 Calling Up a PLU ……………………..65 3.4.1 Using Numeric Key …………………… -
Page 5: General
1. GENERAL 1.1 PRECAUTIONS…
-
Page 6
※ This equipment is indoor use and all the communication wirings are limited to inside of the building. -
Page 7: Introductions
We have designed this equipment with many advanced features, high quality construction, and user-friendly menu driven programming. We are confident that you will find the CAS CL5000J scale will meet all of your most demanding needs. Remember, for proper installation and maintenance please have your…
-
Page 8: Specifications
1.3 SPECIFICATIONS Max. Capacity 3/6 kg 6/15 kg 15/30 kg Interval 1/2 g 2/5 g 5/10 g Max. Tare — 2.999 kg — 5.998 kg — 9.995 kg A/D Conversion Rate Approx. 8 times/sec. Measurement Type Load Cell Platter Size 380 x 244 mm 48 PLU key, 72 PLU key,…
-
Page 9
Number Range 6000 1-999999 direct ingredients 300 chracter 1000 Indirect Ingredient 400 character 1~100 User Defined Barcode Format 1~20 Department 1~99 Origin 1~500 Group 1~99 Programmable Data Bitmap Image Quantity Symbol Report Tare Table 1~99 1~30 Label Format 51~60 Sales Period user selectable reporting period. -
Page 10: Name And Functions
1.4 NAME AND FUNCTIONS ■ Standard Type ■ Pole Type P ■ Pole Type R…
-
Page 11
DISPLAY TO DO : Insert Picture KEYBOARD B-Type (Standard) P Type, R-Type (pole type) -
Page 12: Basic Set-Up
1.5 Basic set-up How to install tray B,P,R type…
-
Page 13: Symbols
1.6 SYMBOLS SYMBOLS DESCRIPTION ST ( ) Stable indicator Zero weight indicator ▶0◀ NET ( ) Net weight indicator AUTO Auto Print Mode indicator SAVE Auto clearing status indicator PREPACK Prepack Mode indicator DC ( ) Discount status indicator SHIFT ( ) Speed key shift status indicator Data transmission status indicator 1.7 KEY FUNCTIONS…
-
Page 14
AUTO key. Auto-print mode AUTO Pre-Pack key. Used to enter Pre-Packaging mode in which the scale Auto-prints for every transaction and PACK ◀ prevents the auto clearing of data. Save key. Save mode prevents the auto clearing of SAVE any called-up data like tare weight, PLU pricing, etc. Void key. -
Page 15
Negative Discount DISC- DELETE key. CL5000 only Alpha keys. Used to type text data. Used to type $ Currenc For future Backspace key. Used to backspace and delete text ← data. Space bar. SPACE Used to go to next line to enter text Ü… -
Page 16: Installation Of The Label Roll
1.8 Installation of the Label Roll ■ Label Specifications Outer diameter of roll : 100mm Inner diameter of roll : 40mm Width of receipt roll : 40, 50, 60mm Width of label roll : 60mm(MAX) ■ Print Area Width of label : 60mm(MAX) Length of label : 80mm(MAX)
-
Page 17
To install the label roll at ANY time you must follow the directions in this section: 1) Press the ON/OFF key and make sure that the display is completely off. Open the printer’s side-access panel. (See fig.1) 2) Lift up TPH lever as fig 2. 3) Remove cartridge as fig. -
Page 18
5) Place the label in the scale as fig. 5 6) Press the FEED key. *If label position is not correct, you have to check follows : a, Label size.(Label setting menu) b. Feed Adjustment .(Feed adjustment menu) c. Sensor calibration(Sensor Calibration menu) -
Page 19: Programming
2. PROGRAMMING Program Mode Menu Tree (Menu code : 1000) CODE Menu CODE Sub Menu CODE Sub Menu 1120 New/Edit 1150 LIST 1100 1144 Expand 1160 Speed Key 1240 Sales Message 1250 Origin 1200 PLU Table1 1260 Barcode 1270 Tare 1280 Unit Symbol 1300…
-
Page 20
1912 DHCP Network 1900 Communication 1910 1913 Setting 1915 RS232C Baudrate How to access PROGRAM MODE You can see the Program Menu screen by pressing the MENU key. 1100 PGm You can use both keys, DATE-TIME/▲ and PLU/▼ to move other menu. Once you choose a suitable menu, press PRINT key to execute program. -
Page 21: Plu Programming
2.1 PLU Programming You can set 20 items for a PLU as below table and if you want to use expanded items(21~28), you can enable those items in menu code:1144. < PLU ITEM> Item Description Department No (1~99) Department No. PLU No (1~999999) PLU No.
-
Page 22: Create By-Weight Plu (Menu Code 1120)
※ Unit Weight Unit weight of Price (default 0 : unit price for 1kg) Tare No You can enter No. of tare data. ☆ Pieces (0-99) Set the number for By-PCS PLU Origin No. (0~500) 0=Do not use origin. Aux. Label No. (0~99) (0=Do not use Label No.), This function prints aux.
-
Page 23
3. Enter PLU 2 First Name 1120 PLU 2 L1-005 bEEF EX) “BEEF” PRINT 4. Enter PLU 3 2nd Name SirLoin 1120 PLU 3 L2-007 EX) “Sirloin” Shift PRINT 5. Enter PLU 4 3rd Name 1120 PLU 4 L3-003 STEAK EX) “STEAK”… -
Page 24
10. Tare * You can use Tare Table, 1120 PLU 9 tArE 0.100 EX) Tare Value = 100 g PRINT 11. Packed Date 1120 PLU10 P-dAtE * This value can be from 0 to 999. EX) 0 : Today 1 : Tomorrow 2: Tomorrow +1 PRINT 12. -
Page 25
17. Select Label Format 1120 PLU16 LAbEL * If you enter “0”, standard label format (menu code 1510) is used. * For details about label format, refer to 8. Setting Global option EX) 1. IS6030-0000(60×30) PRINT 18. Barcode No. * You can use barcode ID depending 1120 PLU17 on the setting of Menu code 1520… -
Page 26
24. Pieces 1120 PLU23 * If you do not want to use, enter “0” This field does not work to By-Weight PLU PRINT 25. Origin No 1120 PLU24 oriGin * If you do not want to use origin, enter “0” EX) 49. -
Page 27: Create By-Count Plu (Menu Code 1120)
2.1.2 Create By-Count PLU (Menu code 1120) (MENU -> PLU -> New/Edit) * You can press the SAVE key at anytime to save the current PLU data and if you want to exit without saving, press the ESC key. 1. Enter Department No. and PLU No. * Department should be set previously 1120 dEPtno…
-
Page 28
7. Item Code 1120 PLU 6 iCodE EX) Item Code = 273 PRINT 8. Use Fixed Price Type 1120 PLU 7 FiXEdP The Price of an item is fixed. * If you do not want to use, enter 0. EX) Fixed Price Type PRINT 9. -
Page 29
14. Sell By Time 1120 PLU13 S-timE * This value can be from 0 to 99. EX) 0 : Do not print 1 : Packed date+ 1hour PRINT 15. Ingredient No 1120 PLU14 mSG no * If you do not want to use, enter “0” EX) Do not use indirect ingredient (use direct ingredient) PRINT 16. -
Page 30
22. Unit Weight 1120 PLU21 Unitw * If you do not want to use, enter “0” This field does not work to By-Count PLU. PRINT 23. Tare No. 1120 PLU22 tArEno PRINT 24. Pieces 1120 PLU23 * If you do not want to use, enter “0” This field work to By-PCS PLU. -
Page 31
29. Fixed Weight 1120 PLU28 FiXEdw 0.000 * If you do not want to use, enter “0” This field does not work to By-Count PLU. PRINT 13. SAVE PLU 1120 SAvE * It’s same function as pressing “SAVE”. PRINT 14. ERASE PLU 1120 ErASE * Delate selected PLU. -
Page 32: Create By-Pcs Plu (Menu Code 1120)
2.1.3 Create By-PCS PLU (Menu code 1120) (MENU -> PLU -> New/Edit) By-PCS PLU is used depending on the Para 593. * You can press the SAVE key at anytime to save the current PLU data and if you want to exit without saving, press the ESC key.
-
Page 33
7. Item Code 1120 PLU 6 iCodE EX) Item Code = 273 PRINT 8. Use Fixed Price Type 1120 PLU 7 FiXEdP The Price of an item is fixed. * If you do not want to use, enter 0. EX) Fixed Price Type PRINT 9. -
Page 34
14. Sell By Time 1120 PLU13 S-timE * This value can be from 0 to 99. EX) 0 : Do not print 1 : Packed date+ 1hour PRINT 15. Ingredient No 1120 PLU14 mSG no * If you do not want to use, enter “0” EX) Do not use ingredient (use direct ingredient) PRINT 16. -
Page 35: Unit Weight
21. Qty Unit No. 1120 PLU20 SymboL EX) Qty Unit No. 6 PRINT 22. Unit Weight 1120 PLU21 Unitw * If you do not want to use, enter “0” This field does not work to By-PCS PLU. PRINT 23. Tare No. 1120 PLU22 tArEno…
-
Page 36
28. Special Price (For future use) 1120 PLU27 SPriCE 0.00 PRINT 29. Fixed Weight 1120 PLU28 FiXEdw 0.000 * If you do not want to use, enter “0” This field does not work to By-PCS PLU. PRINT 13. SAVE PLU 1120 SAvE * It’s same function as pressing “SAVE”. -
Page 37: Editing Plu (Menu Code 1120)
2.1.4 Editing PLU (Menu code 1120) (MENU -> PLU -> New/Edit) * You can edit PLU as PLU creating and you can press the SAVE key at anytime to save the current PLU data and if you want to exit without saving, press the ESC key. 2.1.5 Expand PLU (Menu code 1144) (MENU ->…
-
Page 38: Programming Plu Data Table I
2.2. Programming PLU Data Table I 2.2.1 New/Edit Sales Message (Menu code 1240) (MENU -> PLU Data Table I -> Sales Message) ※ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 39: Origin (Menu Code 1250)
2.2.2 Origin (Menu code 1250) (MENU -> PLU Data Table I -> Origin) You can use origin number when you create PLU. ※ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 40: Barcode (Menu Code 1260)
2.2.3 Barcode (Menu code 1260) (MENU -> PLU Data Table I -> Barcode) You can use barcode when you create PLU. Barcode can be changed depending on the Global setting of barcode ※ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 41
PRINT 1260 CH-007 G G i Barcode format symbol Symbol Description item code PLU number price price check digit (It is created automatically) unit price weight quantity department group total barcode check sum (It is created automatically) transaction counter (serial number) 4. -
Page 42: Tare (Menu Code 1270)
2.2.4 Tare (Menu code 1270) (MENU -> PLU Data Table I -> Tare) ※ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key. 1. Enter Tare No. This value can be from 1 to 99.
-
Page 43: List Unit Symbol (Menu Code 1280)
2.2.5 List Unit Symbol (Menu code 1280) (MENU -> PLU Data Table I -> Unit Symbol ) ※ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key. 1.
-
Page 44: Programming Plu Data Table Ii
2.3 Programming PLU Data Table II 2.3.1 Ingredient (Menu code 1310) (MENU -> PLU Data Table II -> Message) ※ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key. 1.
-
Page 45: Speed Key Setting
2.4 Speed Key Setting This menu is to set “speed keys”, one-touch keys, for most frequently used PLUs to simply call up them. You can program up to 5 speed key set. Remember that there is a SHIFT key that allows you to double-use the Speed Keys. The Speed keys are numbered left-to-right and top-to-bottom.
-
Page 46: Programming Store Data
2.5 Programming Store Data This chapter explains how to access, program STORE data table (Price Look Up) in CL5000J series. 2.5.1 Store Data (Menu code 1410) (MENU -> Store Data Table ->Store) This section shows how to create, edit, list and delete store, customer, and advertisement message data.
-
Page 47: Programming Global Setting
2.6 Programming Global Setting 2.6.1 Global Label Format (Menu code 1510) (MENU -> Global Setting -> Label Format) Label format #51~#60 are free formats that users may modify at their needs. Users may download one into the scale and set a specific free label format. ※…
-
Page 48: Barcode Format (Menu Code 1520)
2.6.2 Barcode Format (Menu code 1520) (MENU -> Global Setting -> Barcode) Global Barcode Setting provides all-in-one barcode setting by selecting nine different barcode options so that user does not need to save data for individual PLUs one by one. All related barcode data are selected and saved from PLU barcode data table user may already register.
-
Page 49: Printing Programming
2.7 Printing Programming This chapter explains how to set printing-related environments. 2.7.1 Printing (Menu code 1700) (MENU -> Print) PRINT Submenu Submenus Description Select Label Item Select item(s) which is(are) not printed on label. Print Hardware Set the label type and sensor of printer 2.7.2 Inhibit(Select) Printing Items(Menu code 1710) (MENU ->…
-
Page 50: Printer Hardware (Menu Code 1730)
2.7.3 Printer Hardware (Menu code 1730) (MENU -> Print -> Printer Hardware) This section is to explain how to set printing H/W environments in the following table. ▶ Printer Hardware Sub-Menu Sub-menus Description Lable mode “Height(40) Label Size * ( ) are default value. Sensor You can mearsure “Gap”…
-
Page 51: Print Intensity (Menu Code 1735)
2.7.7 Print Intensity (Menu code 1735) (MENU -> Print -> Printer Hardware -> Print Intensity) You can enter any value from “0” to “4” set the tension of label. The 2 is default value. 2.7.8 Adjust Feed Length (Menu code 1736) (MENU ->…
-
Page 52: Programming Scale Configuration
2.8 Programming Scale Configuration 2.8.1 Department (Menu code 1830) (MENU -> Scale Config -> Department ) This section shows how to select current department where scale is being used. User can use (call up) PLUs only for current department selected in sales mode. For example, if current department selected is 2(GROCERY) user can call up items registered only in 2(GROCERY) department.
-
Page 53: Change Password (Menu Code 1852)
2.8.3 Change Password (Menu code 1852) (MENU-> Scale Config ->Change Password) 2.8.4 Display Test (Menu code 1861) (MENU -> SCALE CONFIG -> Test -> Display ) To test the display, press “PRINT” on Test menu screen. It automatically tests it. User may exit from testing, using “X/ESC”…
-
Page 54: Scale Parameter (Menu Code 1870)
2.8.8 Scale Parameter (Menu code 1870) (MENU -> Scale Config ->.Scale Parameter) You can set scale’s environment by changing Parameter Values. But you must be careful how you deal it. The Parameters are concerned with Factory Settimg. So your missing might raise some problems. 2.8.9 Clear Memory (Menu code 1890) (MENU ->…
-
Page 55: Report
2.9 Report 2.9.1 Report Menu (Menu code 1600) (MENU -> Report) 1600 ProG rEPort Submenus Description Report Print Print and display sales data Clear All Clear all reports of period 1 and 2 2.9.2 Print Report (Menu code 1610) (MENU -> Report -> Print Report ) There are 3 detailed reports.
-
Page 56: Miscellaneous Plu Report (Menu Code 1613)
PRINT This menu print out information of each PLU data. 2.9.5 Miscellaneous PLU Report (Menu code 1613) (MENU -> Report -> Print Report -> MISC. PLU ) Menu code 1613 print out rest information of sales. It maybe includes some price that didn’t saved in PLU.
-
Page 57: Hourly Report (Menu Code 1616)
2.9.8 Hourly Report (Menu code 1616) (MENU -> Report -> Print Report -> Department) Press “Print” key PLU report menu screen. 1616 Print HoUrLy PRINT Enter the number of Hours and 1616 Print HoUrLy Press “Print” key. PRINT This menu print out information of each data within a day periode of time. 2.9.9 Clear All Report (Menu code 1650) (MENU ->…
-
Page 58: Communicaation
2.10 Communicaation 2.10.1 Communication (Menu code 1900) Communication (MENU -> 1. Feature You can control scale with PC or any computing environment such as, data table up/down loading, deleting. 2. Pre-caution Set each Scale ID different (for individual scale management) Especially for report feature in CL-Works needs individual scale ID to locate report data.
-
Page 59: Network Setting (Menu Code 1910)
4. Before setting the network ■ Each scale needs fixed IP address. ■ Do not use DHCP without prior notice to CAS. If so CL-Works will not able to retract the right scale because access IP address will change constantly.
-
Page 60: Ip (Menu Code 1913)
2.10.4 IP (Menu code 1913) Communication (MENU -> ->Network Setting->IP) Setting IP and Port 1913 iP-SEt 1. 2. Set IP address and Port Scale need to have own TCP/IP NOTE: Recommend to get this information from authorized network personals If scale does not connected to internet or any other POS system, you can set initial IP address (192.168.1.1) and Gateway (192.168.1.1), Subnet Mask (255.255.255.0)
-
Page 61: Sales Operation
3.1 Basic Operation This chapter explains basic operation of scale, such as how to set zero, tare, call up a PLU and override unit price in CL5000J series. In order to make sales transaction user should access REGISTRATION mode. ■ How to access REGISTRATION MODE: Turn ON the scale.
-
Page 62: Manual Tare Entry
you need to temporarily override a PLU’s tare weight, you must enter the tare weight first and then call-up that PLU. There are two ways to enter a tare weight and both ways will only work if there is no PLU or MISC PLU called-up. 3.3.1 Manual Tare Entry ①…
-
Page 63: How To Clear Tare
3.3.3 How to Clear Tare ① Remove the item from the platter 0.000 -0.150 0.00 0.00 ② Press “TARE” key again. 0.000 0.000 1.50 0.00 3.3.4 Preset Tare ① Call up a PLU including tare(weight of container). EX) PLU #3’s tare =150 g 0.010 -0.150 5.00…
-
Page 64: Tare Override
3.3.6 Tare Override ① Call up a PLU including tare (weight of container). EX) PLU #4’s tare = 100 g 0.100 -0.100 0.00 5.00 ② Place the container (Weight of container must be greater than weight data input) for TARE OVERRIDE. 0.100 0.062 5.00…
-
Page 65: Calling Up A Plu
3.4 Calling Up a PLU There are two ways to call up a PLU by using numeric key and preset key. 3.4.1 Using Numeric Key ① Enter PLU number by using numeric keys and press “PLU” key. EX) PLU No. 15 0.000 0.000 0.150…
-
Page 66: Override (For Key)
3.5 Override (FOR key) The OVERRIDE key is used to temporarily change the pricing of priced PLUs. ☞ If you set program menu 1873(Save unit price change), changed priced is saved after printing a label. ☞ If Para 534 : Default UnitWeight is different from unit weight of PLU, “Multiple Unit PLU”…
-
Page 67: By-Count Plu
3.5.2 By-Count PLU — PLU# 2.APPLE ( PLU Type: By count, Unit Price : 1.00$). ① Press OVERRIDE key. OVER RIDE 0.000 1.00 1.00 ② Enter QUANTITY and press FOR key. 0.000 1.00 3.00 ③ Enter new unit price. 0.000 1.50 4.50 ④…
-
Page 68: By-Pcs Plu
3.5.3 By-PCS PLU — PLU# 3.Eggs ( PLU Type: By PCS, Pieces : 3, Unit Price : 30.00$). ① Press OVERRIDE key. OVER RIDE 0.000 3- 3 30.00 30.00 ② Enter QUANTITY and press FOR key. 0.000 5- 3 30.00 50.00 ③…
-
Page 69: Sales Operation
3.6 Sales Operation 3.6.1 Weighed Item Operation EXAMPLE: — PLU No: 29, PLU Name: ONION, PLU type: by weight, Unit Price: 1.50$, — Sales Weight=1.0kg ① Press Speed key to call up a PLU. ONION 0.000 0.000 1.50 0.00 User may call up a PLU by pressing speed key or numeric key. Please refer to chapter 3.4 for details.
-
Page 70: By Count Item
* Total Price= Sales weight X Unit price Note: ☞ — In “SAVE” & “Prepack” mode the PLU is not automatically cleared when you remove the item from the platter. — If you set “PLU clr Aft sale(WT.OnTray)” to “Y” in Menu 1873, PLU is cleared even though you do not remove the item from the platter.
-
Page 71: By Pcs Item
3.6.3 By PCS Item EXAMPLE: — PLU No: 30, PLU Name: ORANGE, PLU type= By PCS, PIECES: 5, Unit Price: 1.99$ Sales=20 pieces. [QUANTITY item] ① Press numeric key(s) to call up a PLU. 0.000 5 — 5 39.80 1.99 …
-
Page 72: Add-Up Transaction
3.7 Add-Up Transaction If you press the ADD key instead of the PRINT key, you will initiate the ADD-UP process. You can ADD-UP 100 items maximum. EXAMPLE: PLU# 32=SIRLOIN, PLU Type = By-Weight, Unit Price=20.00, PLU# 35=T-bone Steak, PLU Type = By-PCS, Pieces=3, Unit Price=6.00 ①…
-
Page 73
④ Press ADD key. PLU is cleared automatically. You will see the display as below. 0.000 10.98 Sub 2 ⑥ To complete the sale, press the PRINT key. (To repeat the ADD-UP process, press the ESC key.) PRINT 0.000 0.200 0.00 0.00 Note:… -
Page 74: Void
3.8 Void You can press the VOID key to undo just one lastest transaction in add-up process operation.. Assumption) You sold several items If there is some PLU and some price to void ② Press ST/TTL key 0.000 33.84 Sub 4 ②…
-
Page 75: Return
3.9 Return The RETURN key is used to delete erroneous sale transactions. You can use the RETURN key to undo erroneous sales transactions like pressing the PRINT key inadvertently, selecting and printing the wrong PLU, an inadvertent Auto-Print in Pre-Pack mode, or perhaps adjusting the sales totals for a damaged or ruined package.
-
Page 76: Prepack Key
3.10 Prepack Key When the scale is in Pre-Pack mode, it prints labels automatically. When it is in MANUAL mode, you must press the PRINT key (or ADD key) to get a label. In Pre-Pack mode, you cannot select AUTO mode. Pre-Pack works like AUTO and SAVE mode except that the weight does not need to return to zero for every auto-print.
-
Page 77: Direct Discount
3.11 Direct Discount If there is no discount information in PLU, you can use this function. 3.11.1 % Discount Price Key ① Place item on the platter and Call up a PLU(#1.APPLE) DISC% and press “%Discount” key 0.000 1.000 5.00 0.00 ②…
-
Page 78: Appendix
4. Appendix 4.1 Label Format There are fixed label format and user label format Fixed Label Format User Label Format 1~50 51~60 Quantity Method Built in CL5000J Download from PC Features You cannot edit format. Using the PC program, you can program format numbers 51 to 60.
-
Page 81
*Total Label… -
Page 82: Label Format Sample
4.2 Label Format Sample (1) Label Sample 1 PLU Name1 PLU Name2 Packed On Date Barcode Sell By Date Weight PLU Number Store Name Total Price Store Tel Unit Price Store Text Label Serial No (2) Label Sample 2 PLU Name2 PLU Name1 Packed On Date Sell By Date…
-
Page 83: Label Field
4.3 Label Field Label Format has several fields and each field has own ID. Item label print the information of each PLU sale and Total label print the information of grand total of PLUs. 4.3.1 Item Label Field Item Field Description Department Name Print department name.
-
Page 84: Ascii Code Table
4.4 ASCII Code Table Microsoft Window Codepage 1252 Note : To enter “A”, first you have to read 40 in a row and 01 in a column and type 41.
-
Page 85: Window Character Set Information
PRINT 0.00 4.5 Window Character Set Information Code Short Name Description Country 1250 Central Europe Windows Latin 2 Albania, Croatia, Czech, Faeroese, Hungarian, Polish, Romanian, Serbian(Latin), Slovak, Slovenian 1251 Cyrillic Windows Cyrillic (Slavic) Byelorussian, Bulgarian, Russian, Ukrainian 1252 Latin 1 Windows Latin 1 (ANSI) Afrikaans, Catalan, Danish, Dutch, English, USA, Canada, New Zealand,…
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
Related Manuals for CAS CL5000J series
Summary of Contents for CAS CL5000J series
-
Page 1
앞표지 CL5000J… -
Page 2: Table Of Contents
Table of Contents 1.GENERAL ………………………………..6 1.1 PRECAUTIONS………………………6 1.2 INTRODUCTIONS……………………..8 1.3 SPECIFICATIONS……………………..9 1.4 NAME AND FUNCTIONS………………….11 1.5 Basic set — up……………………….15 1.6 SYMBOLS……………………….16 1.7 KEY FUNCTIONS……………………..17 1.8 Installation of the Label Roll…………………..20 2. PROGRAMMING …………………………..22 2.1 PLU Programming……………………..26 2.1.1 Create By-Weight PLU (Menu code 1120)………………….27 2.1.2 Create By-Count PLU (Menu code 1120)………………….33 2.1.3 Create By-PCS PLU (Menu code 1120)……………………34 2.1.4 Editing PLU (Menu code 1120)……………………..36…
-
Page 3
2.7.6 Peel Sensor (Menu code 1734)………………………49 2.7.7 Print Intensity (Menu code 1735)……………………..50 2.7.8 Adjust Feed Length (Menu code 1736)……………………50 2.7.9 Label Preprint (Menu code 1737)……………………..50 2.7.10 Printer Initialize (Menu code 1738)…………………….50 2.8 Programming Scale Configuration………………..51 2.8.1 Department (Menu code 1830)……………………..51 2.8.2 Date &… -
Page 4
3.3.4 Preset Tare…………………………….65 3.3.5 Successive Tare…………………………..66 3.3.6 Tare Override……………………………..66 3.4 Calling Up a PLU……………………..67 3.4.1 Using Numeric Key…………………………67 3.4.2 Using Speed Key…………………………..67 3.5 Override (FOR key)……………………..68 3.5.1 By-Weight PLU…………………………..68 3.5.2 By-Count PLU…………………………..69 3.5.3 By-PCS PLU…………………………….70 3.6 Sales Operation……………………….72 3.6.1 Weighed Item Operation…………………………72 3.6.2 By Count Item…………………………..73 3.6.3 By PCS Item……………………………..74 3.7 Add-Up Transaction……………………..76… -
Page 5: General
1.GENERAL PRECAUTIONS…
-
Page 6
※ This equipment is indoor use and all the communication wirings are limited to inside of the building. -
Page 7: Introductions
Authorized CAS dealers are trained to help you with every aspect of the CL5000J and should you need servicing, they are expertly trained by CAS to assist you with virtually any…
-
Page 8: Specifications
SPECIFICATIONS Max. Capacity 3/6kg 6/15kg 15/30kg Interval 1/2g 2/5g 5/10g Max. Tare -2.999kg -5.998kg -9.995kg A/D Conversion Rate Approx. 8 times/sec. Measurement Type Load Cell Platter Size 380 x 244 mm 48 PLU key, 72 PLU key, 36 function 36 function Standard Type (B) Pole Type (P, R) Speed Key…
-
Page 9
Operating Temp. -10°C ~ 40°C (14°F ~ 104°F) Power AC 100~240V 50/60Hz 1.5A Number Range 6000 1-999999 direct ingredients 300 chracter 1000 Indirect Ingredient 400 character 1~100 User Defined Barcode Format 1~20 Department 1~99 Origin 1~500 Programmable Data Group 1~99 Bitmap Image Quantity Symbol Report… -
Page 10: Name And Functions
NAME AND FUNCTIONS OVERALL VIEW ■ Standard Type ■ Pole Type P…
-
Page 11
■ Pole Type R ■ Hanging Type… -
Page 12
DISPLAY ■ Standard Type (B,P) ■ Pole Type R Max 6 / 15 kg Min 40 g e = d = 2 / 5 g KEYBOARD Standard… -
Page 13
Pole type Hanging type… -
Page 14: Basic Set — Up
Basic set — up How to install tray H-type mounting method(3 suggested)
-
Page 15: Symbols
SYMBOLS SYMBOLS DESCRIPTION ST (▼) Stable weight indicator Zero weight indicator ▶ ◀ NET (▼) Net weight indicator AUTO Print Mode indicator SAVE Auto clearing status indicator PREPACK Auto clearing status indicator DC (▼) Discount status indicator SHIFT (▼) Speed key shift status indicator Data transmission status indicator…
-
Page 16: Key Functions
KEY FUNCTIONS DESCRIPTION Numeric keys. Used to enter pricing, qty, count, tare, etc. Double zero key. Clear key. Used to clear erroneous entries and error conditions. Re-Zero key. Use to remove small variations in the scale’s zero. Tare key. Use to manually enter and remove tare weights. Override key.
-
Page 17
DESCRIPTION ADD-Up key. This key when used in conjunction with ST/TTL key allows you print a customer-total label as well as individual transaction labels. Page Down key. only CL5000 Multi-Label key. Use this key to print multiple sales of the same transaction. -
Page 18
DESCRIPTION Alpha keys. Used to type text data. Used to type $ Backspace key. Used to backspace and delete text data. Space bar. Used to go to next line to enter text Special symbol keys. Used to type special symbol. (See ASCII code table on page 192) For future Note: X key is only used in sale mode and ESC key is only used in program mode. -
Page 19: Installation Of The Label Roll
Installation of the Label Roll • Label Specifications Outer diameter of roll : 100mm Inner diameter of roll : 40mm Width of receipt roll : 40, 50, 60mm Width of label roll : 60mm(MAX) • Print Area Width of label : 60mm(MAX) Length of label : 80mm(MAX)
-
Page 20
To install the label roll at ANY time you must follow the directions in this section: ⑨ Press the FEED key. two or times forauto Label adjustment *If label position is not correct, you have to check follows : a, Label size.(Label setting menu) b. -
Page 21: Programming
2. PROGRAMMING Program Mode Menu Tree (Menu code : 1000) CODE Menu CODE Sub Menu CODE Sub Menu 1120 New/Edit 1144 Expand 1100 1150 LIST 1160 Speed Key 1240 Sales Message 1250 Origin PLU Data 1200 1260 Barcode Table 1 1270 Tare 1280…
-
Page 22
CODE Menu CODE Sub Menu CODE Sub Menu 1830 Department/Store/speed key number 1840 Date/Time 1852 Change Password 1861 Display 1862 1860 Test 1863 Keypad Scale 1800 1864 Chess Printer Config 1865 Printer Sensor 1870 Scale Parameter 1891 1892 Table1 1890 Clear Memory 1893 Table2… -
Page 23
How to access PROGRAM MODE You can see the Program Menu screen by pressing the MENU key. You can use both keys, DATE-TIME/▲ and PLU/▼ to move other menu. Once you choose a proper menu, press PRINT key to execute program or transfer to sub menu. NOTE: Refer to the function keys avaiable program and calibration menu. -
Page 24
The sales transaction mode will work after scale’s turning on. First to execute program menu, that menu code should have entered. And then you press the PRINT Key to execute program menu. If you want to execute 1864 test chess print menu, just input choosen menu code. You can see this screen for a while, after pressing PRINT key. -
Page 25: Plu Programming
PLU Programming You can set 20 items for a PLU as below table and if you want to use expanded items(21~28), you can enable those items in menu code:1144. Item Description Department No (1~99) Department No. PLU No (1~999999) PLU No. PLU Type Select PLU type among By Weight(1), By Count(2) or By-PCS(3) Name 1…
-
Page 26: Create By-Weight Plu (Menu Code 1120)
※ Unit Weight Unit weight of Price (default 0 : unit price for 1kg) Item Description Tare No You can enter No. of tare data. ☆ Pieces (0-99) Set the number for By-PCS PLU Origin No. (0~500) 0=Do not use origin. (0~99) (0=Do not use Label No.), Aux.
-
Page 27
3. Enter PLU 2 First Name EX) “BEEF” 4. Enter PLU 3 2nd Name EX) “SiRLOIN” 5. Enter PLU 4 3rd Name EX) “001” 6. Select Group • If there is no group for this PLU, enter “0”. EX) 1. Meat 7. -
Page 28
9. Price EX) Price = $10.00 10. Tare • You can use Tare Table, EX) Tare Value = 100 g 11. Packed Date • This value can be from 0 to 999. EX) 0 : Today 1 : Tomorrow 2: Tomorrow +1 12. -
Page 29
15. Ingredient(Message) No • Refer to 1310 : MESSAGE. • If you do not want to use, enter “0” • Even if this indirect Ingredient number is setted, it doesn’t work while direct Ingredient is active. 16. Ingredient Text •If you want to use direct Ingredient meseage, type character. -
Page 30
21. Qty Unit No. • If you do not want to use, enter “0” This field does not work to By-Weight PLU. Please refer to menu code 1144: PLU EXPAND, to set the remaining plu data 21~28. 22. Unit Weight It set the Unit Weight of Price. -
Page 31
27. Barcode2 No. 28. Special Price (For future use) 29. Fixed Weight The weight of an item is fixed. • If you do not want to use, enter 0. EX) Do not use Fixed Weight 30. SAVE PLU • It’s same function as pressing “SAVE”. 31. -
Page 32: Create By-Count Plu (Menu Code 1120)
2.1.2 Create By-Count PLU (Menu code 1120) ( MENU → 1. PLU → 2. New/Edit ) (1120 + “MENU” key) ◆ You can press the SAVE key at anytime to save the current PLU data and if you want to exit without saving, press the ESC key. ◆…
-
Page 33: Create By-Pcs Plu (Menu Code 1120)
2.1.3 Create By-PCS PLU (Menu code 1120) ( MENU → 1. PLU → 2. New/Edit ) (1120 + “MENU” key) ◆ You can press the SAVE key at anytime to save the current PLU data and if you want to exit without saving, press the ESC key. * Please refer to 2.1.1 for PLU DATA setting which was not mentioned in this chapter 2.1.3.
-
Page 34
5. Qty Unit No. • This field work to By-PCS PLU or By-Count PLU. EX) Qty Unit No. 6 6. Pieces • If you do not want to use, enter “0” This field work to By-PCS PLU. -
Page 35: Editing Plu (Menu Code 1120)
2.1.4 Editing PLU (Menu code 1120) ( MENU → 1. PLU → 2. New/Edit ) ◆ You can edit PLU as PLU creating and you can press the SAVE key at anytime to save the current PLU data and if you want to exit without saving, press the ESC key. 2.1.5 Expand PLU (Menu code 1144) ( MENU →…
-
Page 36: Programming Plu Data Table I
Programming PLU Data Table I 2.2.1 New/Edit Sales Message (Menu code 1240) ( MENU → 2. PLU Data Table I → Sales Message ) You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 37: Origin (Menu Code 1250)
2.2.2 Origin (Menu code 1250) ( MENU → 2. PLU Data Table I → Origin ) You can use origin number when you create PLU. ◆ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 38: Barcode (Menu Code 1260)
2.2.3 Barcode (Menu code 1260) ( MENU → 2. PLU Data Table I → Barcode ) You can use barcode when you create PLU. Barcode can be changed depending on the Global setting of barcode. ◆ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 39
Display that Press Backspace key. • Barcode format symbol Symbol Description item code PLU number price price check digit (It is created automatically) unit price weight quantity department group total barcode check sum (It is created automatically) transaction counter (serial number) -
Page 40: Tare (Menu Code 1270)
4. Save Menu • If you want to save, press “PRINT” key. 2.2.4 Tare (Menu code 1270) ( MENU → 2. PLU Data Table I → Tare ) ◆ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key.
-
Page 41: List Unit Symbol (Menu Code 1280)
2.2.5 List Unit Symbol (Menu code 1280) ( MENU → 2. PLU Data Table I → Unit Symbol ) ◆ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key. 1.
-
Page 42: Programming Plu Data Table Ii
Programming PLU Data Table II 2.3.1 Ingredient (Menu code 1310) ( MENU → 3. PLU Data Table II → Message ) ◆ You can press the SAVE key at anytime to save the current data and if you want to exit without saving, press the ESC key. ◆…
-
Page 43: Speed Key Setting
Speed Key Setting This menu is to set “speed keys”, one-touch keys, for most frequently used PLUs to simply call up them. You can program up to 5 speed key set. Remember that there is a SHIFT key that allows you to double-use the Speed Keys. The Speed keys are numbered left-to-right and top-to-bottom.
-
Page 44: Programming Store Data
Programming Store Data This chapter explains how to access, program STORE data table (Price Look Up) in CL5000J series. 2.5.1 Store Data (Menu code 1410) ( MENU → Store Data Table → Store ) This section shows how to create, edit, list and delete store, customer, and advertisement message data.
-
Page 45: Programming Global Setting
Programming Global Setting 2.6.1 Global Label Format (Menu code 1510) ( MENU → Global Setting → Label Format ) Label format #51~#60 are free formats that users may modify at their needs. Users may download one into the scale and set a specific free label format. ◆…
-
Page 46: Barcode Format (Menu Code 1520)
2.6.2 Barcode Format (Menu code 1520) ( MENU → Global Setting → Barcode ) Global Barcode Setting provides all-in-one barcode setting by selecting nine different barcode options so that user does not need to save data for individual PLUs one by one. All related barcode data are selected and saved from PLU barcode data table user may already register.
-
Page 47: Printing Programming
Printing Programming This chapter explains how to set printing-related environments. 2.7.1 Printing (Menu code 1700) ( MENU → Print ) ▶ PRINT Submenu Sub-menus Description Select Label Item Select item(s) which is(are) not printed on label. Print Hardware Set the label type and sensor of printer 2.7.2 Inhibit(Select) Printing Items(Menu code 1710) ( MENU →…
-
Page 48: Printer Hardware (Menu Code 1730)
2.7.3 Printer Hardware (Menu code 1730) ( MENU → Print → Printer Hardware ) This section is to explain how to set printing H/W environments in the following table. ▶ Printer Hardware Sub-Menu Sub-menus Description Lable mode “Height(40) Label Size * ( ) are default value.
-
Page 49: Print Intensity (Menu Code 1735)
( MENU → Print → Printer Hardware → Peel ) You can select [Y], [N] for “ACTIVE PEEL-OFF”. Selecting [Y], printer didn’t work until you take off former printed label. But [N], when you press print key, label was print out by compulsion. 2.7.7 Print Intensity (Menu code 1735) ( MENU →…
-
Page 50: Programming Scale Configuration
Programming Scale Configuration 2.8.1 Department (Menu code 1830) ( MENU → Scale Config → Department ) This section shows how to select current department where scale is being used. User can use (call up) PLUs only for current department selected in sales mode. For example, if current department selected is 2(GROCERY) user can call up items registered only in 2(GROCERY) department.
-
Page 51: Date & Time (Menu Code 1840)
2.8.2 Date & Time (Menu code 1840) ( MENU → Scale Config → Date/Time ) This section is to set scale’s DATE & TIME appropriately. You can use and number pad. Year 2.8.3 Change Password (Menu code 1852) ( MENU → Scale Config → Change Password ) 2.8.4 Display Test (Menu code 1861) ( MENU →Scale Config →…
-
Page 52: Printer Sensor Test (Menu Code 1865)
2.8.8 Printer Sensor Test (Menu code 1865) ( MENU → Scale Config → Test → Printer Sensor ) User may exit from this menu, using “X/ESC” key. 2.8.9 Scale Parameter (Menu code 1870) ( MENU → Scale Config → Printer Hardware → Scale Parameter ) You can set scale’s environment by changing Parameter Values.
-
Page 53: Clear Table1 (Menu Code 1892)
2.8.10.2 Clear Table1 (Menu code 1892) ( MENU → Scale Config → Clear Memory → Table1 ) Clear all Table1 date(Except PLU/discount data). 2.8.10.3 Clear Table2 (Menu code 1893) ( MENU → Scale Config → Clear Memory → Table2 ) Clear all Table2 date(Except PLU/discount data).
-
Page 54: Report
Report 2.9.1 Report Menu (Menu code 1600) ( MENU → Report ) Sub-menus Description Report Print Print and display sales data Clear All Clear all reports of period 1 and 2 2.9.2 Print Report (Menu code 1610) ( MENU → Report → Print Report ) There are 3 detailed reports.
-
Page 55: Plu Report (Menu Code 1612)
2.9.4 PLU Report (Menu code 1612) ( MENU → Report → Print Report → PLU Report ) Press “Print” key PLU report menu screen. Enter the number of Deprment and Press “Print” key. Enter the number of PLU and Press “Print” key. This menu print out information of each PLU data.
-
Page 56: Deptment Report (Menu Code 1615)
Enter the number of Group and Press “Print” key. This menu print out information of each PLU Group data. 2.9.7 Deptment Report (Menu code 1615) ( MENU → Report → Print Report → Department ) Press “Print” key PLU report menu screen. Enter the number of Department and Press “Print”…
-
Page 57: Clear All Report (Menu Code 1650)
2.9.9 Clear All Report (Menu code 1650) ( MENU → Report → Clear All ) You can delete all of report. If you delete all, then scale will create new report data. When you print out report later, updated report will be printed…
-
Page 58: Communicaation
Communicaation 2.10.1 Communication (Menu code 1900) ( MENU → Communication ) 1. Feature You can control scale with PC or any computing environment,to do work such as data table up/down loading, deleting. 2. Pre-caution Set each Scale ID different (for individual scale management) Especially for report f eature in CL-Works needs individual scale ID to locate report data.
-
Page 59: Network Setting (Menu Code 1910)
4. Before setting the network ■ Each scale needs fixed IP address. ■ Do not use DHCP without prior notice to CAS. If so CL-Works will not able to retract the right scale because access IP address will change constantly.
-
Page 60: Ip (Menu Code 1913)
Change setting with keys. 2.10.4 IP (Menu code 1913) ( MENU → Communication → Network Setting → IP ) Setting IP and Port Set IP address and Port Scale need to have own TCP/IP NOTE: Recommend to get this information from authorized network management person.
-
Page 61: Sales Operation
Basic Operation This chapter explains basic operation of scale, such as how to set zero, tare, call up a PLU and override unit price in CL5000J series. In order to make sales transaction user should access REGISTRATION mode. ■ How to access REGISTRATION MODE: Turn ON the scale.
-
Page 63: Tare
Tare You can enter tare weights as long as there are no PLUs or MISC PLUs called-up. If you need to temporarily override a PLU’s tare weight, you must enter the tare weight first and then call-up that PLU. There are two ways to enter a tare weight and both ways will only work if there is no PLU or MISC PLU called-up.
-
Page 64: How To Clear Tare
② Press “TARE” key. 3.3.3 How to Clear Tare ① Remove the item from the platter ② Press “TARE” key again. 3.3.4 Preset Tare ① Call up a PLU including tare (weight of container). EX) PLU #3 s tare =150 g…
-
Page 65: Successive Tare
② Clear PLU#3, then tare is also automatically cleared. 3.3.5 Successive Tare ① Enter tare (weight of container) using numeric keys. EX) 150 g ② Enter the weight of container using numeric keys. EX) 200 g ③ Press “TARE key after removing item and container from the platter. 3.3.6 Tare Override ①…
-
Page 66: Calling Up A Plu
② Place the container (Weight of container must be greater than weight data input) for TARE OVERRIDE. ③ Pressing “TARE” key overrides current PLU tare (weight of container) and the weightbecomes “O”. Calling Up a PLU There are two ways to call up a PLU by using numeric key and preset key. 3.4.1 Using Numeric Key ①…
-
Page 67: Override (For Key)
Override (FOR key) The OVERRIDE key is used to temporarily change the pricing of priced PLUs. ☞ If you set program menu 1873(Save unit price change), changed priced is saved after printing a label. ☞ If Para 534 : Default UnitWeight is different from unit weight of PLU, “Multiple Unit PLU”…
-
Page 68: By-Count Plu
3.5.2 By-Count PLU — PLU# 2.APPLE ( PLU Type : By count, Unit Price : 1.00$). ① Press OVERRIDE key. ② Enter QUANTITY and press FOR key. ③ Enter new unit price. ④ Enter QUANTITY and press FOR key.
-
Page 69: By-Pcs Plu
3.5.3 By-PCS PLU — PLU# 3.Eggs ( PLU Type : By PCS, Pieces : 3, Unit Price : 30.00$). ① Press OVERRIDE key. ② Enter QUANTITY and press FOR key. ③ Enter PIECES and press FOR key…
-
Page 70
④ Enter new unit price. ⑤ Press PRINT key to print label. -
Page 71: Sales Operation
Sales Operation 3.6.1 Weighed Item Operation EXAMPLE: — PLU No : 29, PLU Name: ONION, PLU type : by weight, Unit Price : 1.50$, — Sales Weight =1.0kg ① Press Speed key to call up a PLU. • User may call up a PLU by pressing speed key or numeric key. Please refer to chapter 3.4 for details.
-
Page 72: By Count Item
④ Remove the item(s) from the platter. * Total Price= Sales weight X Unit price Note: — In “SAVE” & “Prepack” mode the PLU is not automatically cleared when you remove the item from the platter. — If you set “PLU clr Aft sale(WT.OnTray)” to “Y” in Menu 1873, PLU is cleared even though you do not remove the item from the platter.
-
Page 73: By Pcs Item
③ Press “PRINT” key to print a label and complete current transaction. This transaction(s) is saved in the sales record. * Total Price= Piece(s) X Unit price Note: — In “SAVE” & “Prepack” mode, the PLU called up is not automatically cleared when you remove the item from the platter.
-
Page 74
③ Press “PRINT” key to print a label and complete current transaction. This transaction(s) is saved in the sales record. * Total Price= QUANTITY X [Unit price / PIECES] Note: — In “SAVE” & “Prepack” mode the PLU is not automatically cleared when you remove the item from the platter. -
Page 75: Add-Up Transaction
Add-Up Transaction If you press the ADD key instead of the PRINT key, you will initiate the ADD-UP process. You can ADD-UP 399 items maximum. EXAMPLE 2: — PLU# 32=SIRLOIN, PLU Type = By-Weight, Unit Price=20.00, — PLU# 35=T-bone Steak, PLU Type = By-PCS, Pieces=3, Unit Price=6.00 ①…
-
Page 76
④ Press ADD key. PLU is cleared automatically. You will see the display as below. ⑤ To complete the sale, press the PRINT key. (To repeat the ADD-UP process, press the ESC key.) Note: — You can press the VOID key to undo the transaction. (See chapter 3.10). — If you set “Print Item Label”… -
Page 77: Void
Void TYou can press the VOID key to undo transaction in add-up process or floating clerk operation. Assumption) You sold several items ◆ If there is some PLU and some price to void ① Press ST/TTL key ② Press VOID key then last sale is cleared.
-
Page 78: Return
Return The RETURN key is used to delete erroneous sale transactions. You can use the RETURN key to undo erroneous sales transactions like pressing the PRINT key inadvertently, selecting and printing the wrong PLU, an inadvertent Auto-Print in Pre- Pack mode, or perhaps adjusting the sales totals for a damaged or ruined package. Whatever the reason, the RETURN function will decrement returned PLU’s transaction counter and sales totals by the specified amount.
-
Page 79: Prepack Key
Prepack Key When the scale is in Pre-Pack mode, it prints labels automatically. When it is in MANUAL mode, you must press the PRINT key (or ADD key) to get a label. In Pre- Pack mode, you cannot select AUTO mode. Pre-Pack works like AUTO and SAVE mode except that the weight does not need to return to zero for every auto-print.
-
Page 80
③ Label is issued automatically. Note: If the scale is in Prepack mode then it will always auto-print if the Total price is greater than 0.00 and:… -
Page 81: Direct Discount
Direct Discount If there is no discount information in PLU, you can use this function. 3.11.1 % Discount Price Key ① Place item on the platter and Call up a PLU(#1.APPLE) and press “%Discount” key ② ② Enter % amount to discount and press PRINT key Ex) 20% ③…
-
Page 82: Appendix
4. Appendix Label Format There are fixed label format and user label format Fixed Label Format User Label Format 1~30 51~60 Quantity Method Built in CL5000J Download from PC You cannot edit format. Using the PC program, you can program format numbers Features 51 to 60.
-
Page 85
*Total Label… -
Page 86: Fixed Label Format Sample
Fixed Label Format Sample (1) Label sample 1 ▶ (2) Label sample 2 ▶…
-
Page 87: Label Field
Label Field Label Format has several fields and each field has own ID. Item label print the information of each PLU sale and Total label print the information of grand total of PLUs. 4.3.1 Item Label Field Item Field ID Description Department Name Print department name.
-
Page 88
Unit Price Print unit price when it is not applied Markdown Print total price when it is not applied Total Price Markdown Label Serial Print label serial number Store Name Print store name Store Tel Print Telephone numer of store Store Text Print information of store. -
Page 89: Ascii Code Table
ASCII Code Table Microsoft Window Codepage 1252 Note: To enter “A”, first you have to read 40 in a row and 01 in a column and type 41.
-
Page 90: Window Character Set Information
Window Character Set Information…
-
Page 91
MEMO… -
Page 92
MEMO… -
Page 93
MEMO… -
Page 95
뒷표지…
ВЕСЫ ТОРГОВЫЕ С ЧЕКОПЕЧАТЬЮ МОДЕЛИ CL5000 РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ Версия от 01.02.2012 г.
СОДЕРЖАНИЕ: 1 ОБЩИЕ СВЕДЕНИЯ……………………………………………………… 5 1.1МЕРЫ БЕЗОПАСНОСТИ ………………………………………………………………… 5 1.2ТЕХНИЧЕСКИЕ ДАННЫЕ………………………………………………………………… 8
2.7.4УСТАНОВКА ДАТЫ, ВРЕМЕНИ И ФОРМАТА ИХ ПРЕДСТАВЛЕНИЯ …………….. 69 2.7.5ПАРОЛИ И ДОСТУП, ПРОДАВЦЫ…………………………………………………………… 70 2.7.6ДИАГНОСТИКА УСТРОЙСТВ…………………………………………………………………… 74
3.10.1 3.10.2 3.10.3 РЕЖИМ «БЕЗ АВТОРИЗАЦИИ» ……………………………………………………… 103 РЕЖИМ «ПРИКРЕПЛЕННЫЙ» ………………………………………………………… 103 РЕЖИМ «ПЕРЕХОДЯЩИЙ» …………………………………………………………… 103
1 ОБЩИЕ СВЕДЕНИЯ 1.1 МЕРЫ БЕЗОПАСНОСТИ Внимание! Будте осторожны при установке и эксплуатации весов. Безукоснительно соблюдайте приведенные ниже требования мер безопасности! Не разбирайте весы. При появлении любых повреждений или неисправностей немедленно свяжитесь с официальным дилером CAS для
Убедитесь в подключении весов к розетке с нужным напряжением. Не менее чем за 30 минут до начала работы весы необходимо включить для прогрева. Для получения наилучших характиристик при Избегайте случайных ударов по весам. Это эксплуатации выполняйте техническое обслу- может повредить внутренний
Благодарим Вас за покупку весов CL5000 производства фирмы CAS Corporation (Южная Корея) — весов с возможностью печати самоклеющихся этикеток. Эти весы обладают самыми современными возможностями, имеют конструкцию высокого качества и удобный пользовательский интерфейс. Перед началом эксплуатации
1.2 ТЕХНИЧЕСКИЕ ДАННЫЕ Основные технические данные приведены в таблице 1.1. Таблица 1.1 – Технические данные Наибольший предел взвешивания, кг 6 15 30 Цена поверочного деления и дискретность отсчета, г 1/2 2/5 5/10 Максимальная масса тары, кг 5.998 9.998 9.998 Частота 8 АЦ-преобразования, Гц Размер
1.3 КОМПЛЕКТ ПОСТАВКИ Перечень поставляемых компонентов приведен в таблице 1.2. Таблица 1.2 – Комплект поставки Наименование Количество (шт.) Весы CL5000X* 1 Платформа 1 Сетевой шнур 1 Винт крепления стойки (только 4 для модификаций CL5000P и CL5000R) Руководство по эскплуатации 1 * X – один из 4-х
1.4 ОБЩИЙ ВИД Весы CL5000 выпускаются в 4-х модификациях по форме корпуса и расположению отсчетного устройства (дисплеев): базовая модификация — без стойки, с расположением дисплея непосредственно на весах, модификация с горизонтальным расположением дисплеев на стойке, модификация с вертикальным
На рисунках 1.5-1.8 приведены виды дисплея и клавиатуры для некоторых модификаций. Рисунок 1.5 – Вид дисплеев при их горизонтальном расположении на стойке весов (CL5000P) Рисунок 1.6 – Вид клавиатуры весов модификации CL5000B Рисунок 1.7 – Вид клавиатуры весов со стойкой (модификации CL5000P и
Рисунок 1.8 – Вид клавиатуры весов модификации CL5000H 1.5 УКАЗАТЕЛИ Указатели предназначены для индикации определенного состояния или режима работы весов. Условия, при которых каждый указатель включен, приведены в таблице 1.3. Таблица 1.3 – Условия включения указателей Указатель Когда включен
1.6 КЛАВИАТУРА Клавиатура предназначена для управления работой весов. Основное назначение каждой клавиши приведено в таблице 1.4. Таблица 1.4 – Основное назначение клавиш Клавиша Основное назначение Числовые клавиши. Используются для ввода цены, количества, итога, тары, числовых данных в режиме
В режиме взвешивания: добавление текущего товара в список суммируемых товаров. В режиме программирования: переход на одну страницу вниз. + СТР. В режиме взвешивания: печать нескольких этикеток для одного товара. В режиме программирования: переход на предыдущий уровень меню, а при нахождении в
1.7 ПРОГРАММНОЕ ОБЕСПЕЧЕНИЕ ВЕСОВ Программное обеспечение (далее – ПО) весов является встроенным. Идентификационным признаком ПО служит номер версии, который отображается на дисплее весов при их включении (см. п. 1.8). Уровень защиты ПО от непреднамеренных и преднамеренных воздействии в
Установите переключатель, расположенный в нижней части весов, в положение «ON» (вклю- чено). Если самодиагностика весов пройдет успешно, они перейдут в режим взвешивания. При этом на всех дисплеях (кроме графического) должны высветитьтся нули. Если возникли сложности на этом этапе, рекомендуется
Для того чтобы установить рулон этикеток выполните следующие действия: 1. Отключите питание весов тумблером ON/OFF, расположенным на днище весов. Откройте крышку отсека принтера (см. рисунок 1.13). Рисунок 1.13 – Открытие крышки 2. Поднимите рычаг (см. рисунок 1.14). Рисунок 1.14 – Подъем рычага 3.
4. Снимите с картриджа фиксатор и приемную катушку (см. рисунок 1.16). Рисунок 1.16 – Снятие фиксатора и приемной катушки 5. Установите новый рулон (см. рисунок 1.17). Рисунок 1.17 – Установка нового рулона 6. Рулон должен быть установлен, как показано на рисунке 1.18. Наклейка Зазор Термоголовка
2 ПРОГРАММИРОВАНИЕ 2.1 ОБЩИЙ ПОРЯДОК РАБОТЫ В РЕЖИМЕ ПРОГРАММИРОВАНИЯ Вход в режим программирования осуществляется нажатием клавиши МЕНЮ (при условии нахождения весов в режиме взвешивания). После входа в режим программирования на графическом дисплее появится главное меню программирования, на
Таблица 2.1 – Перечень возможных кодов и соответствующих им меню (подменю) Код Меню Код Подменю Код Подменю 1100 Товары 1110 Переоценка 1120 Добавить/изменить 1130 Скидки 1131 Добавить/изменить скидку 1132 Просмотр скидок 1133 Удалить 11331 Удалить по товару № скидку 11332 Удалить по отделу № 11333
1600 Итоги 1610 X1 отчет 1620 Z1 отчет 1630 X2 отчет 1532 1533 1534 1611 1612 1613 1614 1615 1616 1617 Скидка по массе Скидка по штукам Скидка по количеству Итог по весам Итог по запрограммированным товарам по незапрограммирован. товарам Итог Итог по группам Итог по отделам Почасовой итог Итог по
1870 Параметры весов 1900 Интерфейсы 1880 1910 1920 1930 1940 1950 1871 1872 1873 1874 Настройка функций клавиш Сетевые настройки 1911 1912 1913 1914 1915 1916 1917 Приложение ВКЛ/ВЫКЛ. блокировку Проверка весов Копировать все Параметры дисплея Параметры печати Общие параметры Отмена авторизации
10 Кол-во товаров в наборе: ** Количество единиц товара в наборе. 11 Наименование единицы № *** Номер наименования единицы измерения штучных и счетных товаров. 12 Фиксиров. Стоимость Фиксированная стоимость. Вводится значение фиксированной стоимости, которое будет использоваться при вызове товара
* Доступно при вводе весового товара, ** Доступно при вводе счетного товара, *** Доступно при вводе штучного и счетного товара, **** Если введены оба состава продукта (по номеру и прямой), приоритетным будет прямой состав. Примечание. В случае установки в меню с кодом 1510 в строке «Использ. общ.
2.2.1 СОЗДАНИЕ ЗАПИСИ ТОВАРА (МЕНЮ -> 1. Товары -> 2. Добавить/Изменить) В этом разделе описывается последовательность действий, которые необходимо выполнить для ввода в память весов нового товара или для изменения параметров ранее введенного. Ниже по действиям описана процедура ввода нового товара
Введите время, определяющее срок годности. Срок годности вводится как количество часов с момента упаковки, в течение которых товар должен быть продан. Если время срока годности использовать не требуется, введите «0». Нажмите клавишу ПЕЧ. Введите номер состава продукта. Если состав
2.2.3.2 УДАЛЕНИЕ ТОВАРА (МЕНЮ -> 1. Товары -> 4. Управление -> 2. Удалить) Предусмотрено 3 варианта удаления товара: удаление товара определенного номера, удаление всех товаров определенного отдела и удаление всех товаров, хранящихся в памяти весов. Для примера ограничимся рассмотрением удаления
Допустим, номер отдела – 1, а номер товара – 2. Тогда последовательно нажмите клавиши 1, ПЕЧ., 2, ПЕЧ. На дисплее высветится количество продаж этого товара. Для обнуления количества продаж данного товара нажмите клавишу ТЕСТ, для обнуления количества продаж всех товаров – клавишу НУЛЬ. 28
2.3 ДОПОЛНИТЕЛЬНЫЙ СПИСОК I (Меню -> 2. Доп. список I -> 1.Отделы) В весах предусмотрены списки отделов, групп, дополнительных текстов, штрих-кодов, нумерации тары и единиц счета. Список представляет из себя совокупность записей. Каждая запись содержит порядковый номер и значение. Например, запись
2.3.1.2 ПРОСМОТР СПИСКА ОТДЕЛОВ (Меню->2.Доп. список I->1.Отделы ->2.Просмотр отделов) 1. Ввод диапазона Для просмотра списка установленных отделов необходимо ввести диапазон номеров (начальный и конечный номера) отделов, например, с 1-го по 10-ый. 1 ПЕЧ. 1 ПРОСМОТР ОТДЕЛОВ (1/1) — Начальный номер:
2.3.2.1 СОЗДАНИЕ НОВОЙ ГРУППЫ (МЕНЮ -> 2. Доп. список I -> 2.Группы -> 1. Добавить/Изменить группу) 1. Создание новой группы Каждой группе должен быть присвоен номер, который может быть в диапазоне от 1 до 99. Например, нужно ввести группу № 1. 1 Каждая группа должна, кроме номера, содержать
2.3.3 ДОПОЛНИТЕЛЬНЫЕ ТЕКСТЫ (МЕНЮ -> 2. Доп. список I -> 4. Дополнительные тексты) Дополнительные тексты могут вводиться для последующей ссылки на них в записи товаров и, соответственно, для печати на этикетке. Всего может быть введено в память до 99-ти дополнительных текстов. На каждый из
2.3.3.3 УДАЛЕНИЕ ДОПОЛНИТЕЛЬНОГО ТЕКСТА (МЕНЮ ->2. Доп. список I -> 4. Дополнительные тексты -> 3. Удалить дополнительный текст) УДАЛИТЬ ДОП. ТЕКСТ Доп. текст №:[ :[ 1] 1. Ввод номера (1/1) Для удаления дополнительного текста необходимо ввести его номер, например, 1. 1 ПЕЧ. 2.3.4 ШТРИХ-КОД (МЕНЮ ->
Таблица 2.3 – Соответствие цифры типу кодировки штрих-кода № Тип кодировки Максимальное количество разрядов, описание 1 EAN-13 13, печать только цифр 2 3 4 5 6 7 8 9 10 13+5, печать только цифр 8, печать только цифр 24, печать только цифр 12, печать только цифр 13, печать только цифр CODE39: 13,
Таблица 2.4 — Соответствие числового значения формату штрих-кода и описание назначение составляющих разрядов штрих-кода Значение Формат Описание составляющих штрих-кода 0 Пользовательский I: Код товара N: Номер ячейки штрих-код P: Стоимость 1 DDIIIIIPPPPPC V: Проверочный разряд стоимости
2.3.4.2 ПРОСМОТР ШТРИХ-КОДОВ (МЕНЮ -> 2. Доп. список I -> 6. Форматы штрих-кодов -> 2. Просмотр штрих-кодов) 1. Установка диапазона номеров штрих-кодов Для просмотра списка установленных штрих-кодов нужно задать диапазон номеров штрих-кодов, которые необходимо просмотреть, например, с 1-го по
2.3.5 СПИСОК МАСС ТАРЫ (МЕНЮ -> 2. Доп. список I -> 7. Список масс тары) Список масс тары используется для последующего вызова определенной массы тары при вызове товара. При этом, после ввода записи массы тары в список, устанавливается ссылка на номер тары при редактировании товара (см п. 2.2).
X 5. Выход в меню Для выхода в меню нажмите клавишу ВЫХ. ВЫХ * Если Вы ввели тару с номером «1», равную 10 кг (как описано в примере), то при вводе нового товара в память весов при указании номера тары «1» для вводимого товара в дальнейшем (при взвешивании) будет учитываться масса тары, равная 10
2.3.5.4 КЛАВИШИ БЫСТРОГО ВЫЗОВА МАССЫ ТАРЫ (МЕНЮ -> 2. Доп. список I -> 7. Список масс тар -> 4. Клавиши вызова тары ) Для быстрого вызова из памяти весов массы тары можно назначить до 9-ти клавиш из числа клавиш быстрого вызова товара. Для этого предварительно необходимо определить клавиши
5. Выход из меню Для перехода на предыдущий уровень меню нажмите клавишу ВЫХ. Для выхода в режим взвешивания нажимайте клавишу ВЫХ. до тех пор, пока весы не перейдут в режим взвешивания. X ВЫХ. 2.3.6.2 ПРОСМОТР ЕДИНИЦ СЧЕТА (МЕНЮ -> 2. Доп. список I -> 8. Список единиц счета -> 2. Просмотр единиц
2.4 ДОПОЛНИТЕЛЬНЫЙ СПИСОК II 2.4.1 СОСТАВЫ ПРОДУКТОВ (МЕНЮ -> 3. Дополнительный список II -> 1. Составы продуктов) Составы продуктов, как правило, используются для последующей печати на этикетке у соответствующих товаров. В зависимости от управляющей программы весов предусмотрено 1000 прямых
2.4.1.2 ПРОСМОТР СОСТАВОВ ПРОДУКТОВ (МЕНЮ -> 3. Дополнительный список II -> 1. Составы продуктов -> 2. Просмотр составов прод.) 1. Ввод диапазона номеров Для просмотра определенных составов продуктов необходимо ввести диапазон соответствующих им номеров, которые требуется просмотреть, например, с
2.4.2 СКИДКИ НА ОПРЕДЕЛЕННЫЕ ТОВАРЫ (МЕНЮ -> 1. Товары -> 3. Скидки) Скидка может устанавливаться отдельно для каждого товара. Всего существует 11 видов скидок. Кроме этого допускается определить дни недели, в которые будет предоставляться скидка, период дат и период времени. Далее описаны
стоимости 11 Скидка на дополнительное количество по стоимости уменьшается цена за килограмм (за штуку) после достижения заданного порога стоимости. Устанавливается абсолютное значение скидки, на которое уменьшается масса (количество) после достижения заданного порога стоимости. 3. Ввод порогов и
4. Определение дней недели, в которые будет предоставляться скидка СКИДКА ПО МАССЕ Введите 1 или 0: [ВПВСЧПС] Дни недели : [0000111] (5/7) 1-> Скидка есть 0-> Скидки нет Дни считаются слева направо с воскресенья по субботу. Например, требуется установить скидку для четверга, пятницы и субботы. 0 0
Для вывода списка скидок на печать нажмите клавишу ТЕСТ. 2.4.2.3 УДАЛЕНИЕ СКИДОК (МЕНЮ -> 1. Товары -> 3.Скидки -> 3.Удалить скидку) Существует 3 варианта удаления скидок: по номеру товара определенного отдела, по определенному отделу и удаление всех скидок. 2.4.2.3.1 УДАЛЕНИЕ СКИДКИ ПО НОМЕРУ
2.4.3 ОБЩИЕ СКИДКИ (МЕНЮ -> 5. Общие параметры -> 3. Скидка) Кроме установки скидки для каждого товара, есть возможность установить общую скидку, которая может применяться ко всем товарам. 2.4.3.1 ОПРЕДЕЛЕНИЕ ПРИОРИТЕТА СКИДОК (МЕНЮ -> 5. Общие параметры -> 3. Скидка -> 1. Приоритет скидок)
2.4.4 НАСТРОЙКА КЛАВИШ БЫСТРОГО ДОСТУПА (МЕНЮ -> 1.Товары -> 6. «Горячие» клавиши) Всего предусмотрено 5 наборов клавиш быстрого доступа – каждый набор соответствует определенному отделу, номер набора вводится при образовании нового отдела (см. раздел 2.2.2). Любая из клавиш быстрого доступа может
2.4.5 МАГАЗИНЫ (МЕНЮ -> 4. Параметры магазина -> 1. Магазины) Магазины вводятся в память весов с целью печати их названия, номера телефона и текста на этикетках. Для случая использования весов в нескольких магазинах предусмотрен ввод информации о 10 магазинах. Далее описан порядок ввода указанных
2.4.5.2 ПРОСМОТР МАГАЗИНОВ (МЕНЮ -> 4. Параметры магазина -> 1. Магазины -> 2. Просмотр назв. магазинов) Предусмотрена возможность просмотра списка введенных магазинов. 1. Ввод диапазона порядковых номеров Допустим, необходимо просмотреть магазины, которым соответствуют номера в диапазоне от 1 до
2.4.6 БЕГУЩАЯ СТРОКА (МЕНЮ -> 4. Магазин -> 3. Реклама на дисплее) В весах предусмотрено отображение бегущей строки во время пауз при продажах. Бегущая строка может содержать любые символы кодировки ASCII. Максимальная длина бегущей строки – 80 символов. Данный пункт меню описывает порядок работы с
4. Определение активности бегущей строки ВВОД РЕКЛАМНЫХ СТРОК (3/7) Показ строки реклымы (Д/Н) : [Д] Для установки активности бегущей строки (бегущая строка будет высвечиваться) в поле ввода значения необходимо установить «Д», для этого используется клавиша 1. Для отмены активности бегущей строки в
7. Установка диапазона дат, в которые будет высвечиваться сообщение ВВОД РЕКЛАМНЫХ СТРОК (6/7) Дата начала :[11-01-06]ДД-ММ-ГГ Дата окончания:[13-01-06]ДД-ММ-ГГ Сообщение будет высвечиваться только в том диапазоне дат, который установлен в данном пункте меню. Даты вводятся в формате день-месяц-год.
2.4.7 БЫСТРАЯ СМЕНА ФОРМАТА ЭТИКЕТКИ (МЕНЮ -> 4. Магазин -> 7. Клавиши форматов этикеток) В весах предусмотрена функция быстрой смены формата этикетки (по нажатию одной клавиши). Для использования этой функции в память весов предварительно необходимо ввести номер клавиши формата этикетки (в
2.5 ОСНОВНЫЕ НАСТРОЙКИ 2.5.1 ФОРМАТ ЭТИКЕТКИ (МЕНЮ -> 5. Общие параметры -> 1. Формат этикетки) В данном разделе описывается изменение номера используемого формата этикетки. Более подробное описание форматов этикеток смотрите в пункте 4.1 настоящего руководства. 1. Определение формата На данном
5. Определение направления итоговой этикетки при печати При выводе на печать итоговой этикетки ее допускается перевернуть. Для установки переворота необходимо установить значение «Д» (устанавливается нажатием клавиши 1), для отказа от переворота – значение «Н» (устанавливается нажатием клавиши 0).
2. Установка номера формата штрих-кода для запрограммированного весового товара ФОРМАТ ШТРИХ-КОДА Вкл. общ. штрих-код (1=Д/0=Н): [ Д ] № ш.-кода весов. тов. :[2] № щ.-кода штучн. тов. :[0] (1/4) ФОРМАТ ШТРИХ-КОДА Вкл. общ. штрих-код (1=Д/0=Н): [ Д ] № ш.-кода весов. тов. :[2] № щ.-кода штучн. тов.
2.6 ПАРАМЕТРЫ ПЕЧАТИ Данный раздел описывает процедуры настройки наличия или отсутствия вывода на печать (этикетку) определенных данных при продажах, а также настройку некоторых параметров печати. ПАРАМЕТРЫ ПЕЧАТИ 1. Список печати этикетки 2. Показывать скидку 3. Настройки принтера (1/2) ПАРАМЕТРЫ
Таблица 2.10 — Информация, допустимая для вывода на печать (этикетку) № страОписание ницы меню 1 Название отдела Номер отдела Номер группы 2 Номер товара Наименование № 1 Наименование № 2 3 Наименование № 3 Код товара Единица массы 4 Масса тары Количество Единица счета 5 Продать до (дата) Продать
2.6.2 ПОКАЗ СКИДКИ (МЕНЮ -> 7. Параметры печати -> 2. Показывать скидку) В данном пункте описывается процедура установки наличия (отсутствия), а также настройки вывода на печать стоимости с учетом скидки и без учета скидки. Для краткости ввод каждого параметра описываться не будет, а будет лишь
Таблица 2.12 – Параметры печати № Название разОписание раздела дела 1 Режим печати Выбор режима печати: режим печати чеков, этикеток или сплошная лента. Установка размера этикетки (чека) в миллиметрах: “Ширина 2 Размеры чека/этикетки (60)”, “Длина (40)” и “Зазор(2)”; стандартный размер чека:
2.6.3.3 НАСТРОЙКА ДАТЧИКОВ (МЕНЮ -> 7. Параметры печати -> 3. Настройка принтера 3. Настройка датчиков) В этом пункте допускается определить значения протяжки и отрыва ленты. Как правило, калибровка датчиков проводится после замена ленты этикеток. В любом случае рекомендуется автоматическая
2.6.3.6 СДВИГ ПЕЧАТИ (МЕНЮ -> 7. Параметры печати -> 3. Настройка принтера 6. Сдвиг печати) Настройка сдвига печати позволяет корректировать положение области печати по вертикали. Точная настройка сдвига печати упростит снятие напечатанной этикетки. Сдвиг печати определяется установленным значением
Таблица 2.13 – Назначение символов, составляющих номер этикетки Обозначение Назначение Пример простого номера этикетки I Код товара N Номер продукта P Стоимость U Цена за килограмм #0001 W Масса Q Количество Пример простого номера чека D Отдел G Группа A Счетчик этикеток B Счетчик транзакций
2.6.6.1 ВАРИАНТЫ ПЕЧАТИ ЧЕКА (МЕНЮ -> 7. Параметры печати -> 6. Печать чеков ->1. Варианты печати чека) В данном пункте меню допускается определить использование списка печати, наличие печати штрих-кода, итога покупки, копии чека и списка печати копии чека. Для примера предположим, что требуется
2.7 КОНФИГУРАЦИЯ (МЕНЮ -> 8. Конфигурация) В этом разделе описаны процедуры настроек всевозможных параметров работы весов. Ниже показаны все страницы основного раздела режима «Конфигурация». КОНФИГУРАЦИЯ 1.РЕЖИМ ПРОДАЖ 2.РЕЖИМ РАБОТЫ 3.НОМЕР ВЕСОВ (1/3) КОНФИГУРАЦИЯ 7. ПАРАМЕТРЫ ВЕСОВ 8. ФУНКЦИИ
Таблица 2.15 — Дополнительное описание режимов продаж Выполняемые Режим Продавец операции 1.Переходящий прода- Переходящий вец, «чеки» продавец Продажа 2. «Этикетки» (без проПродажа давца) Без продавца 3. Фасовка (без продавца) Без продавца Продажа 4. Переходящий прода- Переходящий Продажа вец,
2.7.2 РЕЖИМЫ РАБОТЫ (МЕНЮ -> 8. Конфигурация -> 2. Режимы работы) Данный раздел описывает изменение режима работы продавца и режима работы весов. Допустимые режимы работы весов: «регистрация», «без отчета» и «администратор». Допустимые режимы работы продавца: «без авторизации», «прикрепленный
2.7.3 УСТАНОВКА ТЕКУЩЕГО ОТДЕЛА И МАГАЗИНА (МЕНЮ -> 8. Конфигурация -> 3. Номер весов) На весах можно менять номер текущего отдела и номер магазина (например, если одни весы используются для работы в разных отделах или разных магазинах). При работе весов в основном режиме можно делать вызов из
2. Установка формата представления года, времени и разделителя даты Формат года определяет формат представления года: четырехзначное (значение 0) или двузначное (значение 1). Формат времени определяет формат представления времени: 24-х часовой (значение 0) или 12-ти часовой (значение 1). В качестве
5 Уровень доступа Уровень доступа продавца может принимать значения в диапазоне от 0 до 3. Уровень доступа определяет полномочия продавца (какими функциями и настройками продавец может пользоваться). 1. Ввод номера, ФИО и псевдонима продавца Например, номер продавца – 2, ФИО – Иванов, псевдоним –
1. Ввод номера продавца УДАЛИТЬ ПРОДАВЦА Продавец №:[ 2] Петров (1/1) Для удаления продавца введите его уникальный номер, например, 2. 2 ПЕЧ. 2.7.5.5 УРОВНИ ДОСТУПА ПРОДАВЦОВ (МЕНЮ -> 8. Конфигурация -> 5. Пароли и доступ -> 5. Уровни доступа ) Раздел «Уровни доступа» описывает установку разрешения
14 Изменение стоимости 15 Открыть денежный ящик 16 Доступ к меню 17 Изменение данных о товаре 18 Изменение цены товара 19 Доступ к общим параметрам 20 Доступ к X-отчету 21 Доступ к Z-отчету 22 Изменение параметров магазина 23 Изменение скидки 25 Изменение массы тары 26 Конфигурация весов 29 30
2.7.5.6 КЛАВИШИ ПРОДАВЦОВ (МЕНЮ -> 8. Конфигурация -> 5. Пароли и доступ 6. Клавиши продавцов) В этом разделе описывается присвоение определенному продавцу определенной клавиши продавца. Каждому продавцу может быть назначена своя клавиша. Всего продавцам может быть назначено до 31-й клавиши (см.
2.7.6.1 ТЕСТИРОВАНИЕ ДИСПЛЕЯ (МЕНЮ -> 8. Конфигурация -> 6. Тест -> 1. Дисплей ) Для тестирования дисплея нажмите клавишу 1 в меню «ТЕСТ». Выход из режима тестирования – клавиша ВЫХ. 2.7.6.2 ТЕСТИРОВАНИЕ АЦП (МЕНЮ -> 8. Конфигурация -> 6. Тест -> 2. АЦП ) Для тестирования АЦП нажмите клавишу 2 в
2.7.6.5 ТЕСТИРОВАНИЕ ДАТЧИКОВ ПРИНТЕРА (МЕНЮ -> 8. Конфигурация -> 6. Тест -> 5. Датчики принтера) Для тестирования датчиков принтера нажмите клавишу 5 в меню «ТЕСТ». Для тестовой печати нажмите клавишу ТЕСТ. Выход из режима тестирования – клавиша ВЫХ. ДАТЧИКИ ПРИНТЕРА Отрыв бумаги:[ЗАНЯТО ] Печ.
2.7.7 ПАРАМЕТРЫ ВЕСОВ (МЕНЮ -> 8. Конфигурация -> 7. Параметры весов) Этот раздел описывает некоторые параметры работы весов, доступные для изменения: параметры работы дисплея, печати и др. (см. таблицу 2.21). Для краткости перечень конкретных действий описываться не будет, а в таблице 2.21 сведены
Штучн. тов. без клавиши Д/Н Д/Н Весовой тов. без клавиши Налог вкл. в стоимость «Регистр» вместо «Возвр.» Д/Н Д/Н Д/Н Двойное кол-во клав. Тов. Д/Н 4. Отмена авторизации (Код меню:1874) Сброс авториз. после опер. Сброс авториз. через(0.1с) 1~99 Определяет наличие работы клавиш быстрого доступа для
2. Установка назначения клавиши Введите номер функции, которую будет исполнять назначаемая клавиша (см. таблицу 2.22). Например, требуется установить значение «12». 1 2 ФУНКЦИИ КЛАВИШ Код клавиши: [ 4] Клавиша функции: [12] (1/1) ПЕЧ. Таблица 2.22 – Соответствие числового значения номеру функции №
25~28 [ВАЛЮТА 1~4] Вызов таблицы валют* 31~39 [ТАРА 1~9] Вызов тары из списка масс тар 51~83 ПРОДАВЕЦ(V1~V32) Регистрация продавца 83~90 [УСТАНОВКА ФОРМАТА ЭТИКЕТКИ] Изменение формата этикетки * В версии весов для стран СНГ данная функция заблокирована. ** На части весов данная функция доступна
2.8.2 ОТЧЕТЫ ВИДА X1/X2 (МЕНЮ -> 6. Итоги -> 1. X1 Отчет / 3. X2 Отчет) Далее, для получения отчета необходимо нажать клавишу, соответствующую его варианту (см. таблицу 2.24). X1 ОТЧЕТ 1. ИТОГ ПО ВЕСАМ 2. ИТОГ ПО ЗАПР. ТОВАРАМ 3. ИТОГ ПО НЕЗАПР. ТОВАРАМ (1/3) Таблица 2.24 – Соответствие клавиши
2.8.2.2 ОТЧЕТЫ ВИДА X1/X2 ПО ЗАПРОГРАММИРОВАННЫМ ТОВАРАМ (МЕНЮ -> 6. Итоги -> 1.X1 Отчет / 3. X2 Отчет -> 2. Итог по запр. Това рам) Данный пункт меню отчетов описывает порядок получения отчетов вида X1 (X2) для всех операций продаж, совершенных с определенными запрограммированными товарами
2.8.2.3 ОТЧЕТЫ ВИДА X1/X2 ПО НЕЗАПРОГРАММИРОВАННЫМ ТОВАРАМ (МЕНЮ -> 6. Итоги -> 1.X1 Отчет / 3. X2 Отчет -> 3. Итог по незапр. товарам) На первой странице данного пункта меню необходимо определить тип незапрограммированных товаров, по операциям с которыми требуется получить отчет: 0 — весовой
2.8.2.4 ОТЧЕТЫ ВИДА X1/X2 ПО ГРУППАМ (МЕНЮ -> 6. Итоги -> 1. X1/X2 Отчет -> 4. Итог по группам) Введите диапазон номеров групп, по которым требуется получить отчет, например, с 1-ой по 5-ю. 1 84 ПЕЧ. 5 X1 ИТОГ ПО ГРУППАМ С №[ 0]по №[ 5] (1/1) ПЕЧ. На дисплее высветится отчет по заданной группе
2.8.2.5 ОТЧЕТЫ ВИДА X1/X2 ПО ОТДЕЛАМ (МЕНЮ -> 6. Итоги -> 1/4. X1/X2 Отчет -> 5. Итог по отделам) Введите диапазон номеров отделов, по которым требуется получить отчет, например, с 1-го по 3-ий. 1 ПЕЧ. 3 X1 ИТОГ ПО ОТДЕЛАМ С №[ 0]по №[ 3] (1/1) ПЕЧ. На дисплее высветится отчет по заданным отделам.
2.8.2.7 ОТЧЕТЫ ПО ПРОДАВЦАМ ВИДА X1/X2 (МЕНЮ -> 6. Итоги -> 1/4. X1/X2 Отчет -> 7. Итог по продавцам) На данном этапе требуется ввести диапазон номеров продавцов, по операциям которых требуется получить отчет. Например, с 1-го по 2-ого. 1 86 ПЕЧ. 2 X1 ИТОГ ПО ПРОДАВЦАМ С №[ 1]по №[2] (1/1) ПЕЧ. На
2.8.3 ОТЧЕТЫ ПО ВЕСАМ ВИДА Z1/Z2 (МЕНЮ -> 6. Итоги -> 2/4. Z1/Z2 Итог по весам) Для вывода подробного отчета на печать и удаления отчетных данных нажмите клавишу ТЕСТ. На дисплее весов высветится запрос подтверждения. Для подтверждения вывода на печать и удаления данных нажмите клавишу 1. Z1 ИТОГ
2.9 ИНТЕРФЕЙСЫ ОБМЕНА ДАННЫМИ В весах реализована возможность обмена данными по интерфейсу «RS-232», а также и по «TCP/IP» (технология Ethernet), если весы не поставлялись без данной возможности. При подключении весов к компьютеру реализуются следующие функции: • Загрузка списка товаров в память
Для входа в режим настроек параметров связи выполните следующие действия: При нахождении весов в режиме взвешивания, нажмите последовательно клавиши МЕНЮ, 9. В случае запроса пароля введите пароль и нажмите клавишу ПЕЧ. ИНТЕРФЕЙСЫ 1. СЕТЕВЫЕ НАСТРОЙКИ 2. ПРИЛОЖЕНИЕ 3. ВКЛ./ВЫКЛ. БЛОКИРОВКУ (1/1)
3 РАБОТА В ОСНОВНОМ РЕЖИМЕ В этом разделе рассматриваются основные операции по работе с весами в режиме продаж. При включении питания весов, если самодиагностика прошла успешно, весы переходят в режим продаж. При этом на всех дисплеях должны высвечиваться нули. Следует отметить, что в данном
3.2 РАБОТА С ТАРОЙ Режим работы с тарой удобен для получения массы груза нетто при взвешивании груза в таре. В режиме взвешивания массу тары допускается ввести двумя способами: с клавиатуры весов или путем измерения массы тары на платформе. 3.2.1 ВВОД МАССЫ ТАРЫ С КЛАВИАТУРЫ Для ввода массы тары с
3.3 ВЫЗОВ ИЗ ПАМЯТИ ЗАПРОГРАММИРОВАННОГО ТОВАРА И ПЕЧАТЬ ЭТИКЕТКИ Данные по предварительно запрограммированному товару можно вызвать из памяти двумя способами: с помощью клавиши быстрого доступа или посредством ввода номера ячейки памяти, которая содержит данные о товаре (с помощью числовых
Если требуется напечатать больше одной этикетки, нажмите клавишу X и введите соответст- вующее число.* Нажмите клавишу ПЕЧ. * В некоторых версиях прошивок весов данная функция заблокирована. В этом случае, для ее использования, обратитесь к поставщику для проведения соответствующих настроек.
* В некоторых версиях весов данная функция заблокирована. В этом случае, для ее использования, обратитесь в техническую службу для проведения соответствующих настроек. 3.4 ВЗВЕШИВАНИЕ И ПЕЧАТЬ ЭТИКЕТКИ ДЛЯ НЕЗАПРОГРАММИРОВАННЫХ ТОВАРОВ 3.4.1 ВЕСОВОЙ ТОВАР Далее рассмотрены действия, которые
3.4.2 ШТУЧНЫЙ ТОВАР Далее рассмотрены действия, которые продавец должен выполнить при продаже незапрограммированного штучного товара. Нажмите клавишу ШТУЧН. ТОВАР. Используя числовые клавиши, введите количество единиц товара. 0.000 СТАБ. 2 ►0◄ НЕТТО 5.00 АВТО СОХР. ФАСОВКА 10.00 СКИДКА
3.5 ИЗМЕНЕНИЕ ЦЕНЫ ЗА ЕДИНИЦУ ЗАПРОГРАММИРОВАННОГО ТОВАРА После вызова запрограммированного товара из памяти можно изменить цену за единицу. В случае с весовым товаром для изменения цены используется клавиша КОРР. ЦЕНЫ. Рассмотрим примеры. 3.5.1 ВЕСОВОЙ ТОВАР Сделайте вызов товара из памяти в
3.6 ВВОД МАССЫ ТОВАРА С КЛАВИАТУРЫ ВЕСОВ После вызова запрограммированного товара из памяти можно ввести его массу с клавиатуры весов. При этом товар на платформу весов класть не нужно. Внимание! Для возможности использования данной функции необходимо назначить ей одну из клавиш быстрого доступа
3.7 РЕЖИМ СУММИРОВАНИЯ Режим суммирования удобно использовать, когда покупка состоит из нескольких товаров или когда происходит упаковка товаров в общую тару, на которую впоследствии нужно наклеить этикетку с суммарной массой (количеством) или стоимостью. При суммировании для каждого товара
0.000 1.500 25.01 СТАБ. ►0◄ НЕТТО АВТО СОХР. ФАСОВКА 37.52 СКИДКА строчн. ДАННЫЕ Нажмите клавишу +. 0.000 SUb СТАБ. ►0◄ НЕТТО tot АВТО 2 СОХР. ФАСОВКА 57.52 СКИДКА строчн. ДАННЫЕ Снимите товар с платформы. Для продолжения суммирования продолжайте выполнять описанные действия для каждого
ется взвесить товар, который не нужно включать в число суммируемых, а потом продолжить работу в режиме суммирования. Для завершения суммирования и получения итоговой этикетки нажмите клавишу ЧАСТ. ИТОГ/ИТОГ. При этом не имеет значения, включен ли режим суммирования. После этого нажмите клавишу
3.9 ФАСОВКА Режим фасовки удобно использовать при фасовке, т.е. взвешивании товаров с последующим наклеиванием этикетки и размещением в торговом зале. В режиме фасовки (в случае с весовым товаром) этикетки печатаются автоматически, т.е. после взвешивания не нужно нажимать клавишу ПЕЧ. Кроме этого,
3.9.4 ПРИМЕНЕНИЕ СКИДКИ В ПРОЦЕНТАХ При взвешивании товара можно ввести скидку в процентах от стоимости, которая будет учтена в стоимости при операции и на этикетке. Для ввода скидки в процентах используется клавиша СКИД (%). Пример ввода скидки описан ниже. Сделайте вызов товара из памяти в
3.10 РЕЖИМЫ РАБОТЫ ПРОДАВЦА В весах предусмотрено 3 режима работы продавца (оператора): без авторизации, прикрепленный и переходящий. Перед использованием режимов «прикрепленный» и «переходящий» необходимо провести соответствующие настройки в меню с кодами 1820, 1850 и 1880 (соответственно пункты
3.11 АВТОМАТИЧЕСКАЯ ПЕЧАТЬ ЭТИКЕТОК В весах предусмотрен режим автоматической печати этикеток для запрограммированных весовых товаров, при нахождении весов в котором после взвешивания товара (если он уже вызван из памяти) и после вызова товара из памяти (если товар уже на платформе) этикетка
3.13 ИСПОЛЬЗОВАНИЕ ДОПОЛНИТЕЛЬНЫХ НАСТРАИВАЕМЫХ ФУНКЦИЙ Кроме вышеописанных функций в весах предусмотрены дополнительные функции, которые можно использовать только после проведения специальных настроек. Все дополнительные фукнции выполняются по нажатию одной клавиши, поэтому основная настройка —
3.13.6 СБРОС ПОКАЗАНИЙ ВСЕХ ДИСПЛЕЕВ В весах предусмотрена функция сброса показаний всех дисплеев. Для использования этой функции необходимо предварительно назначить для выполнения этой функции одну из клавиш быстрого доступа (см. п. 2.7.8). После проведения соответствующих настроек для сброса
4 ПРИЛОЖЕНИЯ 4.1 ФОРМАТЫ ЭТИКЕТОК Каждому формату этикетки присвоен свой уникальный номер. Существуют стандартные (встроенные заводом-изготовителем) форматы этикеток и форматы пользовательских этикеток, которые возможно загрузить с персонального компьютера, используя программное обеспечение
Наименование 1 Наименование 2 Время упаковки Штрих-код Дата упаковки Цена за килограмм Цена килограмм Срок за годности Масса Масса Стоимость Стоимость 4040мм мм Название магазина Дополнительный текст 60 мм Рисунок 4.3 – Формат этикетки № 12 Наименование 1 Цена за килограмм Стоимость Масса Время
Таблица 4.2 – Вид форматов этикеток Номер 1 Вид этикетки Номер 13 2 14 3 15 4 16 11 17 12 18 Вид этикетки 109
Номер 19 Вид этикетки Номер 31 20 32 21 33 22 34 25 35 26 36 110 Вид этикетки
Номер 37 Вид этикетки Номер 40 38 41 39 42 Вид этикетки Примечание. Форматы этикеток в таблице 4.2 представлены без учета фактического масштаба и без соблюдения пропорций размеров. 111
4.2 КОДЫ СИМВОЛОВ Часто при вводе данных требуется ввести символы, отсутствующие на клавиатуре в явном виде. В этом случае следует ввести код символа, выполнив следующие действия: — Нажать клавишу КОД СИМВ. — Ввести код нужного символа в соответствии с таблицей 4.2. — Нажать клавишу ПЕЧ. Таблица
5 ЛИСТ ПОВЕРКИ ВЕСОВ Поверку весов необходимо проводить в том случае, если весы используются в сфере, на которую распространяется Государственный метрологический контроль. Периодичность поверки – 1 раз в год. Заводской (серийный) № весов: ________ . Таблица 5.1 – Учет поверок N п/п Дата Фамилия